Summary
PRRES20241766
Building Permit - Residential
Notice of Violation
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK - ROOF TRUSSES STOP WORK ORDER generated on 05/22/2024 12:00 AM by username 'Robb Popp'. STOP WORK ORDER removed on 06/11/2024 12:00 AM by username 'Robb Popp'. STOP WORK ORDER generated on 06/24/2024 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 06/26/2024 12:00 AM by username 'Shawn Hoffman'.
04/10/2024
04/11/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 04/11/2024
Right of Way Permit Fee $85.00 $85.00 Paid 04/11/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 04/11/2024
Water Tap Fee $3,760.00 $3,760.00 Paid 04/11/2024
Water Meter Fee $680.46 $680.46 Paid 04/11/2024
Valuation Fee New Single Family $2,255.08 $2,255.08 Paid 04/11/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 01/03/2025
Not Ready Inspection Fee $75.00 $75.00 Paid 01/03/2025
Not Ready Inspection Fee $75.00 $75.00 Paid 01/03/2025
3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 01/03/2025
Not Ready Inspection Fee $75.00 $75.00 Paid 01/03/2025
Not Ready Inspection Fee $75.00 $75.00 Paid 01/03/2025
Not Ready Inspection Fee $75.00 $75.00 Paid 01/03/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 01/03/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 01/28/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 02/18/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 03/11/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Pending
Misc
Corrective Action Required
12/30/2024
- Erosion control in place at time of inspection
Occupancy Inspection - Codes Residential Pending
Misc
Corrective Action Required
04/11/2025
- land sewer trace wire - final grading and sod - Provide gutters - Provide down spouts and splash blocks - Address center deck post cut flush **4/11/25 Notice of violation sent. TCO expired
Footing Inspection - Residential Failed - Stop Work 5/22/2024 05/22/2024
Misc
Corrective Action Required
05/22/2024
5/22/24 -Footing poured without inspection. No 3rd party report on record
Footing Inspection - Residential Passed 6/11/2024 6/11/2024 06/11/2024
Misc
Informational
06/11/2024
Footing and piers approved by Derek Perez of Everstead Engineering and Design on 6/3/24
Piers/Caissons Inspection - Residential Passed 06/11/2024
Misc
Informational
06/11/2024
Piers approved by Everstead on 6/3/24
Erosion Control Inspection Residential Failed 06/11/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/11/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Provide site address and maintain silt fence at perimeter
Sewer Service Inspection - R Passed 6/14/2024 6/14/2024 06/14/2024
Erosion Control Inspection Residential Failed 06/14/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/11/2024
6/14/24 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Re establish erosion control at perimeter
Water Service Inspection - R Passed 6/17/2024 6/17/2024 06/17/2024
Erosion Control Inspection Residential Failed 06/19/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
06/19/2024
6/14/24 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Re establish erosion control at perimeter
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/19/2024
6/19/24 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Re establish erosion control at perimeter -Clean silt from street
Erosion Control Inspection Residential Failed - Stop Work 6/24/2024 6/24/2024 06/24/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/19/2024
6/19/24 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Clean silt from street 06/24/24- silt fence has been established, street still needs to be cleaned
Underslab Plumbing Inspection - Residential Passed 6/26/2024 6/26/2024 06/26/2024
Erosion Control Inspection Residential Partial 6/26/2024 06/26/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
06/26/2024
6/19/24 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Clean silt from street 06/24/24- silt fence has been established, street still needs to be cleaned
Misc
Corrective Action Required
06/26/2024
- OK AT TIME OF INSPECTION.
All Rough Inspection - Residential Not Ready 7/19/2024 7/19/2024 07/19/2024
Misc
Corrective Action Required
07/19/2024
Not ready -Install sheathing, nailing pattern, portal hold down straps etc.
Erosion Control Inspection Residential Failed 7/19/2024 7/19/2024 07/19/2024
Misc
Resolved
07/19/2024
- OK AT TIME OF INSPECTION.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/19/2024
7/19/24 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Restore silt fence
All Rough Inspection - Residential Not Ready 7/24/2024 7/24/2024 07/24/2024
Misc
Corrective Action Required
07/19/2024
Not ready -Install hold down straps -Block and nail horizontal seams -Horizontal seams must be in middle 24" of portal leg
Erosion Control Inspection Residential Partial 7/24/2024 7/24/2024 07/24/2024
DCM2 ESC DEFICIENT INSTALLATION
Informational
07/24/2024
7/24/24 In compliance at time of inspection
Erosion Control Inspection Residential Partial 8/1/2024 8/1/2024 08/01/2024
DCM2 ESC DEFICIENT INSTALLATION
Informational
07/24/2024
8/1/24 In compliance at time of inspection
All Rough Inspection - Residential Failed 8/1/2024 8/1/2024 08/01/2024
Misc
Informational
08/01/2024
PFH Exterior only ok to cover
Erosion Control Inspection Residential Failed 08/13/2024
DCM2 ESC DEFICIENT INSTALLATION
Informational
08/01/2024
8/13/24 -Restore silt fence at front of lot
Gas Service Inspection - Residential Passed 9/17/2024 9/17/2024 09/17/2024
Electrical Service Inspection Passed 9/17/2024 9/17/2024 09/17/2024
All Rough Inspection - Residential Failed 9/17/2024 9/17/2024 09/17/2024
Misc
Resolved
09/17/2024
PFH Exterior only ok to cover
Misc
Corrective Action Required
09/17/2024
NO FURTHER INSPECTIONS UNTIL EROSION CONTROL AND OVERGROWN VEGETATION ARE TAKEN CARE OF. -lib’s to be installed to plans (see sizing and placement -complete plumbing above garage -provide hold downs at girder truss above garage per plan -missing wall stud at SW garage -seal top plate penetrations at panel in garage -address holes drilled for electrical closer than 2” to the bottom of floor joist above garage -provide attic access for ceiling space above garage -fire block wall space to ceiling space at owners entry/ garage hvac chase and fire down, kitchen dead spaces into furr down in garage -missing roof boots -address studs overboard for bath 4 dwv -double every other floor joist above first floor where noted in plans, missing in some areas -uncover covered patio for inspection -fire block hvac chase at great room windows -missing multiple floor joists above dining room -solid block floor joist above dining room window at cantilevered area -uncover sheather at front entry to inspection nailing -strap top plates at front entry/dining room wall to adjoining. -smoke/CO to be in the immediate vicinity of bed room and not closer than 3’ to bathroom. (See 2nd floor) -missing multiple truss hangers and multiple hangers incorrect size -missing lateral bracing throughout -missing hold down device at SE corner of home -fire block stairwell wall every 10’ -anchor bolts in basement to be in the middle 1/3 of sill plate -
Erosion Control Inspection Residential Failed 9/17/2024 9/17/2024 09/17/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
09/17/2024
8/13/24 -Restore silt fence at front of lot
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
09/17/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/17/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Erosion Control Inspection Residential Failed 9/27/2024 9/27/2024 09/27/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
09/17/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Clean debris from street and storm inlet
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
09/27/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Not Ready 9/27/2024 9/27/2024 09/27/2024
Misc
Corrective Action Required
09/17/2024
NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IS IN COMPLIANCE-SEE REPORT -lib’s to be installed to plans (see sizing and placement-NOT DONE -complete plumbing above garage-NOT DONE -provide attic access for ceiling space above garage-PROTECT ELECTRICAL WITHIN 6’ OF ACCESS -fire block wall space to ceiling space at owners entry/ garage-hvac chase and fire down, kitchen dead spaces into furr down in garage-SEAL GSPS AT DWV IN GARAGE, BLOCK OFF CORNERS OF KITCHEN FUR DOWN CEILING LINE TO WALL SPACE -missing roof boots-NOT DONE -address studs overboard for bath 4 dwv-NOT DONE -uncover covered patio for inspection-NOT DONE -missing multiple floor joists above dining room-MISSING TRIPLE AND (5) 2x4 stud pack -uncover sheathing at front entry to inspection nailing-PROVIDE JOIST HANGERS THROUGHOUT -strap top plates at front entry/dining room wall to adjoining-STRAP UPSTAIRS CONNECTION AS WELL -Missing hold down device SE corner per plan-NOT DONE -missing multiple truss hangers and multiple hangers incorrect size-MASTER CLOSET, MASTER BATHROOM, -missing lateral bracing throughout m-C7, -anchor bolts in basement to be in the middle 1/3 of sill plate-NOT DONE NOT READY
All Rough Inspection - Residential Failed 10/8/2024 10/8/2024 10/08/2024
Misc
Corrective Action Required
09/27/2024
-lib’s to be installed to plans - Requires 8' at garage side wall -provide attic access for ceiling space above garage-PROTECT ELECTRICAL WITHIN 6’ OF ACCESS -uncover covered patio for inspection-INSTALL TRUSS HOLD DOWNS -missing multiple floor joists above dining room-MISSING (5) 2x4 stud pack -uncover sheathing at front entry to inspection nailing-PROVIDE JOIST HANGERS THROUGHOUT -strap top plates at front entry/dining room wall to adjoining-STRAP UPSTAIRS CONNECTION AS WELL -missing lateral bracing throughout m-C7
Erosion Control Inspection Residential Partial 10/8/2024 10/8/2024 10/08/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
09/27/2024
In compliance at time of inspection
Erosion Control Inspection Residential Partial 10/09/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/08/2024
In compliance at time of inspection
All Rough Inspection - Residential Failed 10/9/2024 10/9/2024 10/09/2024
Misc
Corrective Action Required
10/08/2024
-Use listed conduit at covered deck (PEX is not approved conduit) **OK to insulate
Erosion Control Inspection Residential Failed 10/14/2024 10/14/2024 10/14/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
10/14/2024
In compliance at time of inspection
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/14/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -Maintain damaged silt fence
All Rough Inspection - Residential Not Ready 10/14/2024 10/14/2024 10/14/2024
Misc
Corrective Action Required
10/09/2024
-Use listed conduit at covered deck (PEX IS NOT APPROVED CONDUIT) **OK TO INSULATE. DO NOT COVER INSPECTION ITEMS 10/14/24 -INSPECTION ITEM ALREADY COVERED
Driveway Inspection Passed 10/29/2024 10/29/2024 10/29/2024
Misc
Informational
10/24/2024
10-24-24 BR Driveway is formed up and aggregate is place and compacted ready for concrete. 10-29-24 BR Driveway is constructed to LS specifications.
Sidewalk Inspection Passed 10/29/2024 10/29/2024 10/29/2024
Misc
Informational
10/24/2024
10-24-24 BR Sidewalk is formed up and aggregate is place and compacted ready for concrete. 10-29-24 BR Sidewalk is constructed to LS specifications.
Driveway Inspection Passed 10/31/2024 10/31/2024 10/31/2024
Misc
Informational
10/24/2024
10-24-24 BR Driveway is formed up and aggregate is place and compacted ready for concrete. 10-31-24 JMJ Driveway passed final inspection.
Sidewalk Inspection Passed 10/31/2024 10/31/2024 10/31/2024
Misc
Informational
10/24/2024
10-24-24 BR Sidewalk is formed up and aggregate is place and compacted ready for concrete. 10-31-24 JMJ Sidewalk passed final inspection.
Erosion Control Inspection Residential Failed 11/01/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/14/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Erosion Control Inspection Residential Failed 11/05/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
11/01/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
11/05/2024
11/5/24 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Provide erosion control at perimeter, clean debris from street and remove loose trash from site
Erosion Control Inspection Residential Failed 11/8/2024 11/8/2024 11/08/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
11/05/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Resolved
11/08/2024
11/5/24 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Provide erosion control at perimeter, clean debris from street and remove loose trash from site
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
11/08/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Clean loose gravel from the street
Erosion Control Inspection Residential Partial 11/13/2024 11/13/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
11/13/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Resolved
11/13/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Clean loose gravel from the street
Occupancy Inspection - Codes Residential Not Ready 12/19/2024 12/19/2024 12/19/2024
Misc
Corrective Action Required
12/19/2024
12/19/24 -Not ready -No address, garage lighting not installed, All Rough inspection still outstanding
Occupancy Inspection - Codes Residential Not Ready 12/27/2024 12/27/2024 12/27/2024
Misc
Corrective Action Required
12/19/2024
12/27/24 -Not ready garage lighting not installed, All Rough inspection still outstanding
All Rough Inspection - Residential Passed 12/30/2024 12/30/2024 12/30/2024
Misc
Resolved
12/30/2024
-Use listed conduit at covered deck (PEX IS NOT APPROVED CONDUIT) **OK TO INSULATE. DO NOT COVER INSPECTION ITEMS 10/14/24 -INSPECTION ITEM ALREADY COVERED
Occupancy Inspection - Codes Residential Failed 12/30/2024 12/30/2024 12/30/2024
Misc
Resolved
12/30/2024
12/27/24 -Not ready garage lighting not installed, All Rough inspection still outstanding
Misc
Corrective Action Required
12/30/2024
- guard at front pouch has gaps greater than 4” - Provide landing at deck stairs - Provide gutters - Provide down spouts and splash blocks - Provide spark extender on double switch’s at kitchen counter - Spindles required at garage stairs over 30” rise - Provide (2) 1/2” through bolts at post to beam connections - Address center deck post cut flush - Provide set screw in anti siphon device at main water spigot - Top of basement stairs to landing has a rise over 7 3/4” at door
Erosion Control Inspection Residential Partial 12/30/2024 12/30/2024
Misc
Corrective Action Required
12/30/2024
- Erosion control in place at time of inspection
Occupancy Inspection - Codes Residential Failed 1/2/2025 1/2/2025 01/02/2025
Misc
Corrective Action Required
12/30/2024
- land sewer trace wire - final grading and sod - Provide gutters - Provide down spouts and splash blocks - Spindles required at garage stairs over 30” rise - Address center deck post cut flush - Top of basement stairs to landing has a rise over 7 3/4” at door
Occupancy Inspection - Codes Residential Ready for Temp CO 1/3/2025 1/3/2025 01/03/2025
Misc
Corrective Action Required
01/02/2025
- land sewer trace wire - final grading and sod - Provide gutters - Provide down spouts and splash blocks - Address center deck post cut flush
Occupancy Inspection - Codes Residential Ready for Temp CO 01/28/2025
Misc
Corrective Action Required
01/03/2025
- land sewer trace wire - final grading and sod - Provide gutters - Provide down spouts and splash blocks - Address center deck post cut flush
Occupancy Inspection - Codes Residential Ready for Temp CO 02/18/2025
Misc
Corrective Action Required
01/28/2025
- land sewer trace wire - final grading and sod - Provide gutters - Provide down spouts and splash blocks - Address center deck post cut flush
Occupancy Inspection - Codes Residential Ready for Temp CO 03/11/2025
Misc
Corrective Action Required
02/18/2025
- land sewer trace wire - final grading and sod - Provide gutters - Provide down spouts and splash blocks - Address center deck post cut flush
Occupancy Inspection - Codes Residential Failed 4/11/2025 04/11/2025
Misc
Corrective Action Required
03/11/2025
- land sewer trace wire - final grading and sod - Provide gutters - Provide down spouts and splash blocks - Address center deck post cut flush **4/11/25 Notice of violation sent. TCO expired
Plot Plan Inspection Passed 4/11/2025 04/11/2025
Documents & Images
Date Uploaded File Type Document Name
04/10/2024 W0 #146 - ENGINEERED PLANS
04/10/2024 Application Form WO #146 - PERMIT APP
04/10/2024 WO #146 - PLOT PLAN
04/10/2024 WO #146 - TRUSS DETAILS
04/10/2024 WO #146 - TRUSS LAYOUT
04/11/2024 Approved Plans APPROVED PLANS
04/11/2024 Plot Plan APPROVED PLOT PLAN
04/11/2024 Approved Plans APPROVED TRUSS LAYOUT
04/11/2024 Approved Plans APPROVED TRUSS PACKAGE
04/11/2024 Permit Codes Residential Plan Review
04/11/2024 Permit DS Building Permit
04/11/2024 Receipt Receipt for transaction:2024-002322
05/21/2024 Approved Plans APPROVED PIER PLAN
05/22/2024 Letter Stop Work Order
06/10/2024 3RD Party Insp Report 146 Woodside Ridge - FND-signed
06/11/2024 Letter INSPECTION SUMMARY
06/11/2024 Letter INSPECTION SUMMARY
06/11/2024 Letter INSPECTION SUMMARY
06/14/2024 Letter INSPECTION SUMMARY
06/14/2024 Letter INSPECTION SUMMARY
06/17/2024 Letter INSPECTION SUMMARY
06/19/2024 Letter INSPECTION SUMMARY
06/26/2024 Letter INSPECTION SUMMARY
06/26/2024 Letter INSPECTION SUMMARY
07/19/2024 Letter INSPECTION SUMMARY
07/19/2024 Letter INSPECTION SUMMARY
08/13/2024 Letter INSPECTION SUMMARY
09/17/2024 Letter INSPECTION SUMMARY
09/17/2024 Letter INSPECTION SUMMARY
09/17/2024 Letter INSPECTION SUMMARY
09/17/2024 Letter INSPECTION SUMMARY
09/26/2024 ENGINEERING FIELD REPAIR REPORT
09/27/2024 Letter INSPECTION SUMMARY
09/27/2024 Letter INSPECTION SUMMARY
10/02/2024 Engineer Report/Study ENGINEER FIELD FRAMING REPORT
10/08/2024 Letter INSPECTION SUMMARY
10/09/2024 Letter INSPECTION SUMMARY
10/09/2024 Letter INSPECTION SUMMARY
10/09/2024 Letter INSPECTION SUMMARY
10/14/2024 Letter INSPECTION SUMMARY
10/14/2024 Letter INSPECTION SUMMARY
10/24/2024 Letter INSPECTION SUMMARY
10/24/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
10/31/2024 Letter INSPECTION SUMMARY
10/31/2024 Letter INSPECTION SUMMARY
10/31/2024 Letter INSPECTION SUMMARY
10/31/2024 Letter INSPECTION SUMMARY
10/31/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/05/2024 Letter INSPECTION SUMMARY
11/08/2024 Letter INSPECTION SUMMARY
11/13/2024 Letter INSPECTION SUMMARY
12/19/2024 Letter INSPECTION SUMMARY
12/27/2024 Letter INSPECTION SUMMARY
12/30/2024 Letter INSPECTION SUMMARY
12/30/2024 Letter INSPECTION SUMMARY
01/02/2025 Letter INSPECTION SUMMARY
01/03/2025 Receipt Receipt for transaction:2025-000032
01/03/2025 Certificate/License Codes Temporary Certificate of Occupancy
01/03/2025 Receipt Receipt for transaction:2025-000033
01/28/2025 Letter INSPECTION SUMMARY
01/28/2025 Certificate/License Codes Temporary Certificate of Occupancy
01/28/2025 Receipt Receipt for transaction:2025-000518
02/17/2025 Application Form TCO EXTENSION FORM
02/18/2025 Receipt Receipt for transaction:2025-000958
03/11/2025 WO #146 - TCO Extension 3_11_25
03/11/2025 Letter INSPECTION SUMMARY
03/11/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/11/2025 Receipt Receipt for transaction:2025-001419
04/10/2025 LOT 146 ASBUILT
04/10/2025 Plot Plan APPROVED AS GRADED PLOT PLAN
04/11/2025 Letter Codes 10 Day Letter
04/11/2025 Letter INSPECTION SUMMARY
04/11/2025 Letter INSPECTION SUMMARY
04/11/2025 Letter INSPECTION SUMMARY
04/11/2025 Letter INSPECTION SUMMARY
10/08/2024 Letter INSPECTION SUMMARY
08/01/2024 Letter INSPECTION SUMMARY
08/01/2024 Letter INSPECTION SUMMARY
07/24/2024 Letter INSPECTION SUMMARY
07/24/2024 Letter INSPECTION SUMMARY
06/24/2024 Letter Stop Work Order
02/18/2025 Certificate/License Codes Temporary Certificate of Occupancy
02/18/2025 Letter INSPECTION SUMMARY
01/27/2025 WO #146 - TCO Extension 1_27_25
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.