Summary
PRRES20235728
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW 3 OR 4 FAMILY
NEW FOURPLEX. UNFINISHED BASEMENTS. ROOF TRUSSES.
11/01/2023
11/10/2023
05/06/2024
08/30/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
JASONH@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New 3 or 4 Family $4,933.68 $4,933.68 Paid 11/10/2023
8331401-Water Tap Fee $15,040.00 $15,040.00 Paid 11/10/2023
8350015-Water Meter Fee $2,721.84 $2,721.84 Paid 11/10/2023
8331507-Sanitary Sewer Development Fee $8,636.00 $8,636.00 Paid 11/10/2023
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 11/10/2023
7232302-Residential Excise Tax Fee $2,480.64 $2,480.64 Paid 11/10/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 04/29/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 04/30/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 05/21/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 06/24/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 08/22/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 08/22/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Partial 11/30/2023 11/30/2023
Miscellaneous Correction
Informational
11/30/2023
3728 sewer passed. This is a partial pass only. Other units will be called in later
Sewer Service Inspection - R Failed 12/4/2023 12/4/2023 12/04/2023
Miscellaneous Correction
Informational
11/30/2023
3728 sewer passed. This is a partial pass only. Other units will be called in later
Miscellaneous Correction
Corrective Action Required
12/04/2023
3730 sewer passed but I can not enter it in the system until full erosion control is completed, address numbers are posted and the street swept up. Do not call in for inspections until these items are completed 12/04/23 KBEARD
Erosion Control Inspection Residential Failed 12/4/2023 12/04/2023
Miscellaneous Correction
Corrective Action Required
12/04/2023
Miscellaneous Correction
Corrective Action Required
12/04/2023
Full erosion control is not completed and mud is in the street. Clean mud in street and provide for full erosion control. Address numbers movers are not on site and are required before scheduling inspections No inspections will be completed until streets are cleaned, full erosion control is in place and address numbers are posted 12/04/23 KBEARD
Sewer Service Inspection - R Partial 12/6/2023 12/6/2023 12/06/2023
Miscellaneous Correction
Informational
12/04/2023
3728 sewer passed. This is a partial pass only. Other units will be called in later
Miscellaneous Correction
Resolved
12/06/2023
3732 sewer passed but I can not enter it in the system until full erosion control is completed, address numbers are posted and the street swept up. Do not call in for inspections until these items are completed 12/04/23 KBEARD
Miscellaneous Correction
Informational
12/06/2023
Sewer has passed on units 3730, 3728 and 3722 only. This is a partial pass only Unit 3726 will be scheduled for another day.
Water Service Inspection - R Partial 12/6/2023 12/06/2023
Miscellaneous Correction
Corrective Action Required
12/06/2023
Water for units 3730 and 3728 passed. This is a partial pass only. Other units will be scheduled at a later date
Sewer Service Inspection - R Passed 12/7/2023 12/7/2023 12/07/2023
Miscellaneous Correction
Informational
12/06/2023
3728 sewer passed. This is a partial pass only. Other units will be called in later
Miscellaneous Correction
Informational
12/06/2023
Sewer has passed on units 3730, 3728 and 3722 only. This is a partial pass only Unit 3726 will be scheduled for another day.
Water Service Inspection - R Passed 12/8/2023 12/8/2023 12/08/2023
Miscellaneous Correction
Resolved
12/08/2023
Water for units 3730 and 3728 passed. This is a partial pass only. Other units will be scheduled at a later date
Footing Inspection - Residential Passed 12/13/2023 12/13/2023
Miscellaneous Correction
Informational
12/13/2023
Footing passed by a third party. Piers were not mentioned in footing inspection
Underslab Plumbing Inspection - Residential Passed 12/13/2023 12/13/2023 12/13/2023
Underslab Electrical Inspection - Residential Partial 12/13/2023 12/13/2023 12/13/2023
Misc
Partial Correction
12/13/2023
- Dig out backfill at service entrance to allow inspection of conduit sweep. Exterior north side.
All Rough Inspection - Residential Partial 2/8/2024 2/8/2024 02/08/2024
Miscellaneous Correction
Informational
02/08/2024
CSPF passed on all four units. Okay to cover. This is a partial pass on all rough only
Erosion Control Inspection Residential Partial 2/13/2024 02/13/2024
Miscellaneous Correction
Corrective Action Required
12/04/2023
Miscellaneous Correction
Resolved
02/13/2024
Full erosion control is not completed and mud is in the street. Clean mud in street and provide for full erosion control. Address numbers movers are not on site and are required before scheduling inspections No inspections will be completed until streets are cleaned, full erosion control is in place and address numbers are posted 12/04/23 KBEARD
Miscellaneous Correction
Informational
02/13/2024
Full erosion control is in place and must be maintained until CofO
Electrical Service Inspection Passed 2/20/2024 2/20/2024 02/20/2024
Gas Service Inspection - Residential Passed 2/20/2024 2/20/2024 02/20/2024
Rated Assembly Inspection Failed 2/20/2024 2/20/2024 02/20/2024
Miscellaneous Correction
Corrective Action Required
02/20/2024
3722 SW Maryville rated assembly 3726 Roof sheathing above bathroom north wall is damaged 3730 Roof sheathing above HVAC chase is damaged Garage north wall is missing Fire blocking in the upper 1/3 wall All units need to be fire blocked sealed in stairwell separating floors
Rated Assembly Inspection Failed 02/20/2024
Miscellaneous Correction
Corrective Action Required
02/20/2024
3722 SW Maryville rated assembly 3726 Roof sheathing above bathroom north wall is damaged 3730 Roof sheathing above HVAC chase is damaged Garage north wall is missing Fire blocking in the upper 1/3 wall All units need to be fire blocked sealed in stairwell separating floors
All Rough Inspection - Residential Failed 2/20/2024 2/21/2024 02/20/2024
Miscellaneous Correction
Informational
02/08/2024
CSPF passed on all four units. Okay to cover. This is a partial pass on all rough only
Miscellaneous Correction
Corrective Action Required
02/20/2024
3722 SW Maryville all rough (2) 3730 -Fire block top plate throughout -Fire block chase in garage at plumbing lines -5/8 inch anchor bolts in garage needs to be in the middle 1/3 sole plate -Front porch ceiling joist is over notched -Front porch celing joist needs to be secured to the top plate -Dryer vent needs to be vertically supported 3728 -Joist hanger is missing in kitchen at LVL -Nails missing in joist hanger at living room to entry -Joist in entry to living room is over notched -Entry porch ceiling joist needs to be secured to the top plate -Support dryer vent vertically -Attic access does not have the required 30 inches of headroom -Fire block HVAC chase ceiling 3726 -Garage anchor bolts need to be located in the middle 1/3 of the sole plate -Flexible bathroom vent pipe in the garage is not installed -Nails are missing in joist hanger in the pantry ceiling joist -Secure front porch ceiling joist to top plate -Attic access does not have the required 30 inches of head room -Support dryer vent vertically -Double vent fan in upstairs bathroom needs a 5 inch vent discharge from a 4 inch wye 3722 -Garage anchor bolts needs to be in the middle 1/3 of the sole plate -front porch ceiling joist is over nothed within the two inches of the edge -Front porch ceiling joist needs to be secured to the top plate -Dryer vent needs to be vertically supported -Bathroom exhast fexible pipe is damaged in the upstairs bathroom -Basement stair well needs support under the stair stringer
Erosion Control Inspection Residential Partial 2/22/2024 02/22/2024
Miscellaneous Correction
Corrective Action Required
02/13/2024
Miscellaneous Correction
Informational
02/13/2024
Full erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Informational
02/22/2024
Erosion control is in place and needs to be maintained until CofO
Rated Assembly Inspection Failed 2/22/2024 2/22/2024 02/22/2024
Miscellaneous Correction
Resolved
02/22/2024
3722 SW Maryville rated assembly 3726 Roof sheathing above bathroom north wall is damaged 3730 Roof sheathing above HVAC chase is damaged Garage north wall is missing Fire blocking in the upper 1/3 wall All units need to be fire blocked sealed in stairwell separating floors
Miscellaneous Correction
Corrective Action Required
02/22/2024
3726 Roof sheathing above bathroom north wall is damaged 3730 Roof sheathing above HVAC chase is damaged
All Rough Inspection - Residential Passed 2/22/2024 2/22/2024 02/22/2024
Miscellaneous Correction
Informational
02/20/2024
CSPF passed on all four units. Okay to cover. This is a partial pass on all rough only
Miscellaneous Correction
Corrective Action Required
02/20/2024
3722 SW Maryville all rough (2) 3730 -Fire block top plate throughout -Fire block chase in garage at plumbing lines -5/8 inch anchor bolts in garage needs to be in the middle 1/3 sole plate -Front porch ceiling joist is over notched -Front porch celing joist needs to be secured to the top plate -Dryer vent needs to be vertically supported 3728 -Joist hanger is missing in kitchen at LVL -Nails missing in joist hanger at living room to entry -Joist in entry to living room is over notched -Entry porch ceiling joist needs to be secured to the top plate -Support dryer vent vertically -Attic access does not have the required 30 inches of headroom -Fire block HVAC chase ceiling 3726 -Garage anchor bolts need to be located in the middle 1/3 of the sole plate -Flexible bathroom vent pipe in the garage is not installed -Nails are missing in joist hanger in the pantry ceiling joist -Secure front porch ceiling joist to top plate -Attic access does not have the required 30 inches of head room -Support dryer vent vertically -Double vent fan in upstairs bathroom needs a 5 inch vent discharge from a 4 inch wye 3722 -Garage anchor bolts needs to be in the middle 1/3 of the sole plate -front porch ceiling joist is over nothed within the two inches of the edge -Front porch ceiling joist needs to be secured to the top plate -Dryer vent needs to be vertically supported -Bathroom exhast fexible pipe is damaged in the upstairs bathroom -Basement stair well needs support under the stair stringer
Rated Assembly Inspection Not Ready 2/23/2024 2/23/2024 02/23/2024
Miscellaneous Correction
Resolved
02/23/2024
3726 Roof sheathing above bathroom north wall is damaged 3730 Roof sheathing above HVAC chase is damaged
Miscellaneous Correction
Corrective Action Required
02/23/2024
3726 Roof sheathing above bathroom north wall is damaged 3730 Roof sheathing above HVAC chase is damaged No improvements were made since the last inspection. Walk your property before calling in inspections. It ready fee accessed
Rated Assembly Inspection Passed 2/23/2024 02/23/2024
Miscellaneous Correction
Resolved
02/23/2024
3726 Roof sheathing above bathroom north wall is damaged 3730 Roof sheathing above HVAC chase is damaged No improvements were made since the last inspection. Walk your property before calling in inspections. It ready fee accessed
Rated Assembly Inspection Failed 2/27/2024 2/27/2024 02/27/2024
Misc
Corrective Action Required
02/27/2024
-3722–ceiling has insufficient screws -3728–not ready
Rated Assembly Inspection Passed 2/28/2024 02/28/2024
Misc
Resolved
02/28/2024
Erosion Control Inspection Residential Failed 3/6/2024 03/06/2024
Miscellaneous Correction
Resolved
03/06/2024
Miscellaneous Correction
Informational
02/22/2024
Full erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Informational
02/22/2024
Erosion control is in place and needs to be maintained until CofO
Miscellaneous Correction
Corrective Action Required
03/06/2024
Clean gravel out of the street. All other erosion control measures are in place
Driveway Inspection Partial 3/13/2024 3/13/2024 03/13/2024
Misc
Informational
03/12/2024
3-12-24 Dustin A, talked with contractor on some issues that needed to be addressed. Moved to 3-13 3-13-24 DW is formed to city specs approved to pour
Sidewalk Inspection Partial 3/13/2024 3/13/2024 03/13/2024
Misc
Corrective Action Required
03/12/2024
3-12-24 Dustin A, Talked with contractor on some issues needing fixed. Moved to 3-13 3-13-24 Dustin A, SW is formed and compacted to city specs. Approved to pour
Driveway Inspection Passed 3/20/2024 3/20/2024 03/20/2024
Misc
Informational
03/13/2024
3-12-24 Dustin A, talked with contractor on some issues that needed to be addressed. Moved to 3-13 3-13-24 DW is formed to city specs approved to pour 3-20-24 Dustin A, DW's are poured to city specs. Passed
Erosion Control Inspection Residential Failed 04/05/2024
Miscellaneous Correction
Informational
03/06/2024
Full erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Informational
03/06/2024
Erosion control is in place and needs to be maintained until CofO
Miscellaneous Correction
Corrective Action Required
03/06/2024
Clean gravel out of the street. All other erosion control measures are in place
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/05/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Remove restrooms from driveways
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/08/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed 4/8/2024 4/8/2024 04/08/2024
Miscellaneous Correction
Informational
04/05/2024
Full erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Informational
04/05/2024
Erosion control is in place and needs to be maintained until CofO
Miscellaneous Correction
Corrective Action Required
04/05/2024
Clean gravel out of the street. All other erosion control measures are in place
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/05/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Remove restrooms from driveways 4-8-24 Dustin A, Talked with super from summit. Said he would get them removed. Will check back in 2 days Restrooms need to be removed from driveways and sidewalks.
Underslab Electrical Inspection - Residential Passed 4/8/2024 04/08/2024
Misc
Resolved
04/08/2024
- Dig out backfill at service entrance to allow inspection of conduit sweep. Exterior north side.
Erosion Control Inspection Residential Passed 04/10/2024
Miscellaneous Correction
Informational
04/08/2024
Full erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Informational
04/08/2024
Erosion control is in place and needs to be maintained until CofO
Miscellaneous Correction
Corrective Action Required
04/08/2024
Clean gravel out of the street. All other erosion control measures are in place
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/08/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Remove restrooms from driveways 4-8-24 Dustin A, Talked with super from summit. Said he would get them removed. Will check back in 2 days Restrooms need to be removed from driveways and sidewalks.
Misc
Corrective Action Required
04/10/2024
4-10-24 Dustin A, Restrooms have been removed
Occupancy Inspection - Codes Residential Failed 4/19/2024 4/19/2024 04/19/2024
Miscellaneous Correction
Corrective Action Required
04/19/2024
3722 SW Maryville. Occupancy Seal all garage ceiling penetrations Remove dust covers from CO detectors Basement bottom handrail does not meet at the top riser nosing Front porch will need a guardrail installed with a 30 inch or more drop off 3726 Front porch will need a guardrail installed with a 30 inch or more drop off Under the sink electrical receptacle has a 1/4 inch gap next to it Seal all garage ceiling penetrations Basement stairwell top riser to wood floor has a greater height than 7 3/4 inches 3728 front porch will need a guardrail installed with a 30 inch or more drop off Oven anti tip bracket is not working properly and according to manufacturer installation Basement stairwell top riser to wood floor has a greater height than 7 3/4 inches Basement handrail needs to return to the wall Hot water heater electrical is in contact with water pipe Garage ceiling light not installed Seal all garage ceiling penetrations Top of stairwell step to platform upstairs has a greater than 3/8 riser difference Remove CO detector dust covers 3730 Remove CO dust covers Seal all garage ceiling penetrations Seal hole in garage next to water faucet All units -Seal all exterior penetrations -Sod is not installed -Splash pads not installed -As graded plot plan is required before sodding -pay $75 fee associated with this permit
Sidewalk Inspection Passed 3/28/2024 3/28/2024 04/26/2024
Misc
Corrective Action Required
03/13/2024
3-12-24 Dustin A, Talked with contractor on some issues needing fixed. Moved to 3-13 3-13-24 Dustin A, SW is formed and compacted to city specs. Approved to pour 3-28-24 Dustin A, Sw has partially picture framed panels and picture framed panels which are not permitted 4-26-24 Dustin A, SW passed
Sidewalk Inspection Passed 04/26/2024
Misc
Corrective Action Required
03/28/2024
3-12-24 Dustin A, Talked with contractor on some issues needing fixed. Moved to 3-13 3-13-24 Dustin A, SW is formed and compacted to city specs. Approved to pour 3-28-24 Dustin A, Sw has partially picture framed panels and picture framed panels which are not permitted 4-26-24 Dustin A, SW passed
Occupancy Inspection - Codes Residential Failed 4/26/2024 4/26/2024 04/26/2024
Miscellaneous Correction
Corrective Action Required
04/19/2024
3722 SW Maryville. Occupancy Seal all garage ceiling penetrations Remove dust covers from CO detectors Basement bottom handrail does not meet at the top riser nosing Front porch will need a guardrail installed with a 30 inch or more drop off 3726 Front porch will need a guardrail installed with a 30 inch or more drop off Under the sink electrical receptacle has a 1/4 inch gap next to it Seal all garage ceiling penetrations Basement stairwell top riser to wood floor has a greater height than 7 3/4 inches 3728 front porch will need a guardrail installed with a 30 inch or more drop off Oven anti tip bracket is not working properly and according to manufacturer installation Basement stairwell top riser to wood floor has a greater height than 7 3/4 inches Basement handrail needs to return to the wall Hot water heater electrical is in contact with water pipe Garage ceiling light not installed Seal all garage ceiling penetrations Top of stairwell step to platform upstairs has a greater than 3/8 riser difference Remove CO detector dust covers 3730 Remove CO dust covers Seal all garage ceiling penetrations Seal hole in garage next to water faucet All units -Seal all exterior penetrations -Sod is not installed -Splash pads not installed -As graded plot plan is required before sodding -pay $75 fee associated with this permit
Miscellaneous Correction
Corrective Action Required
04/26/2024
3722 SW Maryville. Occupancy (2) Seal all garage ceiling penetrations (this includes the attic access) 3726 Seal all garage ceiling penetrations 3728 Garage ceiling light not installed Seal all garage ceiling penetrations (this includes the attic access) Top of stairwell step to platform upstairs has a greater than 3/8 riser 3730 Seal all garage ceiling penetrations All units -Seal all exterior penetrations -Sod is not installed -Splash pads not installed -As graded plot plan is required before sodding -pay $75 fee associated with this permit
Plot Plan Inspection Failed 4/26/2024 04/26/2024
Miscellaneous Correction
Corrective Action Required
04/26/2024
As graded plot plan is required before sodding. As graded plot plan has not been submitted
Occupancy Inspection - Codes Residential Ready for Temp CO 4/29/2024 4/29/2024 04/29/2024
Miscellaneous Correction
Resolved
04/29/2024
3722 SW Maryville. Occupancy Seal all garage ceiling penetrations Remove dust covers from CO detectors Basement bottom handrail does not meet at the top riser nosing Front porch will need a guardrail installed with a 30 inch or more drop off 3726 Front porch will need a guardrail installed with a 30 inch or more drop off Under the sink electrical receptacle has a 1/4 inch gap next to it Seal all garage ceiling penetrations Basement stairwell top riser to wood floor has a greater height than 7 3/4 inches 3728 front porch will need a guardrail installed with a 30 inch or more drop off Oven anti tip bracket is not working properly and according to manufacturer installation Basement stairwell top riser to wood floor has a greater height than 7 3/4 inches Basement handrail needs to return to the wall Hot water heater electrical is in contact with water pipe Garage ceiling light not installed Seal all garage ceiling penetrations Top of stairwell step to platform upstairs has a greater than 3/8 riser difference Remove CO detector dust covers 3730 Remove CO dust covers Seal all garage ceiling penetrations Seal hole in garage next to water faucet All units -Seal all exterior penetrations -Sod is not installed -Splash pads not installed -As graded plot plan is required before sodding -pay $75 fee associated with this permit
Miscellaneous Correction
Corrective Action Required
04/29/2024
3722 SW Maryville. Occupancy (3) All units -Seal all exterior penetrations -Sod is not installed -Splash pads not installed -As graded plot plan is required before sodding All units passed for TCO only
Occupancy Inspection - Codes Residential Ready for Temp CO 5/21/2024 05/21/2024
Miscellaneous Correction
Resolved
05/21/2024
3722 SW Maryville. Occupancy (3) All units -Seal all exterior penetrations -Sod is not installed -Splash pads not installed -As graded plot plan is required before sodding All units passed for TCO only
Miscellaneous Correction
Corrective Action Required
05/21/2024
3722 SW Maryville. Occupancy All units -Seal all exterior penetrations -Sod is not installed -Splash pads not installed -As graded plot plan is required before sodding All units are on a TCO TCO extension form was completed and excepted by the City New TCO is set to expire on 06/29/2024
Erosion Control Inspection Residential Partial 6/20/2024 06/20/2024
Miscellaneous Correction
Informational
06/20/2024
Erosion control is in place and must be maintained until CofO
Occupancy Inspection - Codes Residential Ready for Temp CO 6/24/2024 06/24/2024
Miscellaneous Correction
Resolved
06/24/2024
3722 SW Maryville. Occupancy All units -Seal all exterior penetrations -Sod is not installed -Splash pads not installed -As graded plot plan is required before sodding All units are on a TCO TCO extension form was completed and excepted by the City New TCO is set to expire on 06/29/2024
Miscellaneous Correction
Corrective Action Required
06/24/2024
3722 SW Maryville. Occupancy All units -Seal all exterior penetrations -Sod is not installed -Splash pads not installed -As graded plot plan is required before sodding All units are on a TCO TCO extension form was completed and excepted by the City
Occupancy Inspection - Codes Residential Failed 7/26/2024 07/26/2024
Miscellaneous Correction
Corrective Action Required
06/24/2024
3722 SW Maryville. Occupancy All units -Seal all exterior penetrations -Sod is not installed -Splash pads not installed -As graded plot plan is required before sodding All units are on a TCO TCO extension form was completed and excepted by the City
Erosion Control Inspection Residential Passed 8/13/2024 08/13/2024
Miscellaneous Correction
Resolved
08/13/2024
Erosion control is in place and must be maintained until CofO
Occupancy Inspection - Codes Residential Ready for Temp CO 8/13/2024 08/13/2024
Miscellaneous Correction
Resolved
08/13/2024
3722 SW Maryville. Occupancy All units -Seal all exterior penetrations -Sod is not installed -Splash pads not installed -As graded plot plan is required before sodding All units are on a TCO TCO extension form was completed and excepted by the City
Miscellaneous Correction
Corrective Action Required
08/13/2024
3722 SW Maryville. Occupancy All units -Seal all exterior penetrations -Sod is not installed -Splash pads not installed -As graded plot plan is required before sodding All units are on a TCO TCO extension form was completed and excepted by the City
Plot Plan Inspection Failed 8/20/2024 08/20/2024
Miscellaneous Correction
Resolved
08/20/2024
As graded plot plan is required before sodding. As graded plot plan has not been submitted
Miscellaneous Correction
Corrective Action Required
08/20/2024
As graded plot plan is required before sodding. As graded plot plan has not been submitted Uploaded plot plan for review does not have the engineers stamp
Plot Plan Inspection Passed 8/22/2024 08/22/2024
Miscellaneous Correction
Resolved
08/22/2024
As graded plot plan is required before sodding. As graded plot plan has not been submitted Uploaded plot plan for review does not have the engineers stamp
Occupancy Inspection - Codes Residential Failed 8/22/2024 08/22/2024
Miscellaneous Correction
Resolved
08/22/2024
3722 SW Maryville. Occupancy All units -Seal all exterior penetrations -Sod is not installed -Splash pads not installed -As graded plot plan is required before sodding All units are on a TCO TCO extension form was completed and excepted by the City
Miscellaneous Correction
Corrective Action Required
08/22/2024
3722 Water meter is covered with sod 3730 Water meter extension ring is off set from the well 3728 Water valve is 18 inches above grade All other items have been corrected
Occupancy Inspection - Codes Residential Full C of O 8/30/2024 8/30/2024 08/30/2024
Miscellaneous Correction
Resolved
08/30/2024
3722 Water meter is covered with sod 3730 Water meter extension ring is off set from the well 3728 Water valve is 18 inches above grade All other items have been corrected
Documents & Images
Date Uploaded File Type Document Name
11/01/2023 OS # 14 - PERMIT APP
11/06/2023 Permit Codes Residential Plan Review
11/08/2023 Plot Plan APPROVED PLOT PLAN
11/08/2023 Permit Codes Residential Plan Review
11/10/2023 Approved Plans APPROVED PLANS
11/10/2023 Approved Plans APPROVED TRUSS LAYOUT
11/10/2023 Permit Codes Residential Plan Review
11/10/2023 Permit DS Building Permit
11/10/2023 Receipt Receipt for transaction:2023-008435
11/30/2023 Letter INSPECTION SUMMARY
12/04/2023 Letter INSPECTION SUMMARY
12/04/2023 Letter INSPECTION SUMMARY
12/06/2023 Letter INSPECTION SUMMARY
12/06/2023 Letter INSPECTION SUMMARY
12/07/2023 Letter INSPECTION SUMMARY
12/08/2023 Letter INSPECTION SUMMARY
12/08/2023 Letter INSPECTION SUMMARY
12/13/2023 M L Crose 3722 SW Maryville PL LSMO Osage Lot 14 Clayton P 2023-5728 3rd Party Footing Inspection Report 11-18-23
12/13/2023 Letter INSPECTION SUMMARY
12/13/2023 Letter INSPECTION SUMMARY
12/13/2023 Letter INSPECTION SUMMARY
01/08/2024 14 OSAGE LETTER
02/08/2024 Letter INSPECTION SUMMARY
02/13/2024 Letter INSPECTION SUMMARY
02/20/2024 Letter INSPECTION SUMMARY
02/20/2024 14 Osage Field Issue Letter
02/20/2024 14 OSAGE LETTER
02/20/2024 Letter INSPECTION SUMMARY
02/20/2024 Letter INSPECTION SUMMARY
02/22/2024 Letter INSPECTION SUMMARY
02/22/2024 Letter INSPECTION SUMMARY
02/22/2024 Letter INSPECTION SUMMARY
02/22/2024 Letter INSPECTION SUMMARY
02/22/2024 Letter INSPECTION SUMMARY
02/22/2024 Letter INSPECTION SUMMARY
02/23/2024 Letter INSPECTION SUMMARY
02/23/2024 Letter INSPECTION SUMMARY
02/27/2024 Letter INSPECTION SUMMARY
02/28/2024 Letter INSPECTION SUMMARY
03/06/2024 Letter INSPECTION SUMMARY
03/13/2024 Letter INSPECTION SUMMARY
03/13/2024 Letter INSPECTION SUMMARY
03/20/2024 Letter INSPECTION SUMMARY
03/28/2024 Letter INSPECTION SUMMARY
03/28/2024 Letter INSPECTION SUMMARY
04/05/2024 Letter INSPECTION SUMMARY
04/05/2024 Letter INSPECTION SUMMARY
04/08/2024 Letter INSPECTION SUMMARY
04/08/2024 Letter INSPECTION SUMMARY
04/08/2024 Letter INSPECTION SUMMARY
04/10/2024 Letter INSPECTION SUMMARY
04/19/2024 Letter INSPECTION SUMMARY
04/26/2024 Letter INSPECTION SUMMARY
04/26/2024 Letter INSPECTION SUMMARY
04/26/2024 Letter INSPECTION SUMMARY
04/26/2024 Letter INSPECTION SUMMARY
04/26/2024 Letter INSPECTION SUMMARY
04/26/2024 Letter INSPECTION SUMMARY
04/29/2024 Receipt Receipt for transaction:2024-002707
04/30/2024 Certificate/License Codes Temporary Certificate of Occupancy
04/30/2024 Receipt Receipt for transaction:2024-002748
05/20/2024 Application Form OS #14 - TCO Extension 5_20_2024
05/21/2024 Certificate/License Codes Temporary Certificate of Occupancy
05/21/2024 Receipt Receipt for transaction:2024-003759
06/20/2024 Letter INSPECTION SUMMARY
06/20/2024 OS #14 - TCO Extension 6_20_2024
06/24/2024 Letter INSPECTION SUMMARY
06/24/2024 Certificate/License Codes Temporary Certificate of Occupancy
06/24/2024 Receipt Receipt for transaction:2024-005088
07/26/2024 Letter Codes 10 Day Letter
07/30/2024 Letter TCO EXTENSION
08/13/2024 Letter INSPECTION SUMMARY
08/13/2024 Letter INSPECTION SUMMARY
08/13/2024 Letter Codes 10 Day Letter
08/13/2024 Letter INSPECTION SUMMARY
08/20/2024 LOT 14 ASBUILT ROUGH
08/20/2024 Letter INSPECTION SUMMARY
08/20/2024 Letter INSPECTION SUMMARY
08/21/2024 APPROVED AS BUILT PLOT PLAN for 3722 SW Maryville
08/22/2024 OS #14 - TCO Extension 8_22
08/22/2024 Certificate/License Codes Temporary Certificate of Occupancy
08/22/2024 Certificate/License Codes Temporary Certificate of Occupancy
08/22/2024 Receipt Receipt for transaction:2024-007097
08/22/2024 Letter INSPECTION SUMMARY
08/22/2024 Letter INSPECTION SUMMARY
08/30/2024 Letter Field Certificate of Occupancy
08/30/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home