Permit Application Status

PRRES20231091


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20231091
Building Permit - Residential
Certificate of Occupancy
NEW DUPLEX
NEW TOWNHOME. ROOF TRUSSES. FINISHED/UNFINISHED BASEMENTS. PATIO.
03/15/2023
04/07/2023
09/16/2023
01/31/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
Savanna Scarbo, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:321  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JASONH@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Duplex $2,624.57 $2,624.57 Paid 04/07/2023
Water Tap Fee $7,460.00 $7,460.00 Paid 04/07/2023
Water Meter Fee $1,101.00 $1,101.00 Paid 04/07/2023
Sanitary Sewer Development Fee $2,768.00 $2,768.00 Paid 04/07/2023
Right of Way Permit Fee $85.00 $85.00 Paid 04/07/2023
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 04/07/2023
Residential Excise Tax Fee $217.60 $217.60 Paid 05/18/2023
$1,240.32
Not Ready Inspection Fee $75.00 $75.00 Paid 01/30/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Passed 4/14/2023 4/14/2023 04/14/2023
Sewer Service Inspection - R Passed 4/14/2023 04/14/2023
Water Service Inspection - R Passed 4/17/2023 04/17/2023
Erosion Control Inspection Residential Failed 5/10/2023 05/10/2023
Miscellaneous Correction
Corrective Action Required
05/10/2023
-2121 SW Osage needs erosion control along the east side and to reinstall front yard silt fence that is no longer serving it intend purpose -2123 SW Osage needs the front yard silt fence reinstalled that is longer serving its intended purpose
Electrical Service Inspection Failed 5/15/2023 5/15/2023 05/15/2023
Miscellaneous Correction
Corrective Action Required
05/15/2023
2123 Electrical panel is not Bonded/Grounded 2121 Passed
Rated Assembly Inspection Passed 5/15/2023 5/15/2023 05/15/2023
Gas Service Inspection - Residential Passed 5/15/2023 5/15/2023 05/15/2023
All Rough Inspection - Residential Failed 5/15/2023 5/15/2023 05/15/2023
Miscellaneous Correction
Corrective Action Required
05/15/2023
2121 -Top plate penetrations throughout need to be sealed -fire blocking in garage broken due to electrical wires -fire block at chase ceiling in garage -anchor bolt in garage missing -missing joist hanger nails throughout -LIP bracing in front entry coat closet is missing nails -2x6 top plate in utility needs to be strapped -fire blocking not completed 2123 -a/c supply ducting in garage is over 10 feet between bracing -top plate penetrations throughout house need to be sealed -joist hangers in living room is missing nails -gap in living room top plate and needs a strap installed -electrical panel does not have a ground/bonding wire installed -basement bathroom fur down needs to be fire blocked facing the rec room
All Rough Inspection - Residential Passed 5/16/2023 5/16/2023 05/16/2023
Miscellaneous Correction
Resolved
05/16/2023
Erosion Control Inspection Residential Failed 5/16/2023 05/16/2023
Miscellaneous Correction
Corrective Action Required
05/10/2023
-2121 SW Osage needs erosion control along the east side of property
Electrical Service Inspection Passed 5/16/2023 5/16/2023 05/16/2023
Miscellaneous Correction
Resolved
05/16/2023
2123 Electrical panel is not Bonded/Grounded 2121 Passed
Erosion Control Inspection Residential Failed 6/19/2023 06/19/2023
Miscellaneous Correction
Corrective Action Required
05/16/2023
-2121 SW Osage needs erosion control along the east side of property
Miscellaneous Correction
Corrective Action Required
06/19/2023
Erosion control is still needed around the perimeter of the property. Erosion control along the east side of property has been noted before and has never been addressed. This is the third warning. This will be a two day warning that erosion control is needed and control measures need to be addressed before fees may be issued
Driveway Inspection Passed 6/28/2023 6/28/2023 06/27/2023
Misc
Informational
06/23/2023
6-23-23 BR Driveway is framed and aggregate has been place and compacted. Ready for concrete. 6-27-23 BR Driveway is concreted to LS specification
Sidewalk Inspection Passed 6/28/2023 6/28/2023 06/27/2023
Misc
Informational
06/23/2023
6-23-23 BR Sidewalk is framed and aggregate has been place and compacted. Ready for concrete. 6-27-23 BR Sidewalk is concreted to LS specification
Footing Inspection - Residential Passed 7/7/2023 07/07/2023
Misc
Informational
07/07/2023
Passed by a third party
Occupancy Inspection - Codes Residential Failed 7/7/2023 7/7/2023 07/07/2023
Miscellaneous Correction
Corrective Action Required
07/07/2023
2121 - Address numbers are not properly illuminated. Numbers need to be below the light fixture for full coverage - Kitchen sink hot water does not have a anti hammer valve installed - Garage to house stair has a riser to threshold at 7 3/4 inch and the next riser is at 7 1/8. Code is no more than a 3/8 riser difference - Sump pump electric conduit at the top needs a bushing installed so the wire does not rub through - Address in basement where the electrician cut two holes closer than two inches apart where the main line goes through the floor/ceiling joist - First tread riser from main floor to upstairs it greater than allowable 7 3/4 inches high - Washer/dryer does not have a anti water hammer devise installed - Master bath shower is missing it’s fixtures - Front porch electrical box is missing the cover - Sod is not installed - Splash blocks are not installed - Sump pump discharge must be 36 inches away from the foundation - Exterior electrical panels need to be sealed at the top - A/C disconnect needs to be sealed at the top - A/C disconnect whip needs to be secured within 12 inches from disconnect at the siding/foundation - Address erosion under the front porch entry sidewalk - Erosion control is not in place - Rock siding is missing at garage - Exterior garage lights are not sealed 2123 - address numbers are higher than the exterior light fixture and will not illuminate correctly - Oven anti tip bracket is not working - Anti water hammer devise is not installed under the kitchen sink - Garage to house door self closing hinge is not working - Vertical boards above garage overhead door needs to be sealed - Basement bathroom electrical has a hot ground reverse - Main water line in the basement does not have a anti siphon valve installed - Sump pump metal conduit needs a bushing at the top install so it rub the wiring - First step riser from wood floor to the stairwell is 8 1/4 inches in height. Code calls for a maximum riser height to be 7 3/4 inches - Fist step to second step in the stairwell is over the allowed height difference of 3/8 of an inch (8 1/4 to 7 5/8 inch) - Electrical panel does not have clearance width of 30 inches E3405.2 - Washer/dryer does not have a anti water hammer devise installed - Exterior sump pump extension is not installed - A/C anti siphon knobs are not installed - Top of A/C disconnect is not sealed - Sod is not installed - Exterior splash pads are not installed - Erosion control is not in place - Rick siding is missing at garage - Exterior garage lights are not sealed
Erosion Control Inspection Residential Failed 7/7/2023 07/07/2023
Miscellaneous Correction
Corrective Action Required
06/19/2023
-2121 SW Osage needs erosion control along the east side of property
Miscellaneous Correction
Corrective Action Required
06/19/2023
Erosion control is still needed around the perimeter of the property. Erosion control along the east side of property has been noted before and has never been addressed. This is the third warning. This will be a two day warning that erosion control is needed and control measures need to be addressed before fees may be issued
Misc
Corrective Action Required
07/07/2023
Erosion control around perimeter is needed
Erosion Control Inspection Residential Failed 7/11/2023 07/11/2023
Miscellaneous Correction
Corrective Action Required
07/07/2023
-2121 SW Osage needs erosion control along the east side of property
Miscellaneous Correction
Corrective Action Required
07/07/2023
Erosion control is still needed around the perimeter of the property. Erosion control along the east side of property has been noted before and has never been addressed. This is the third warning. This will be a two day warning that erosion control is needed and control measures need to be addressed before fees may be issued
Misc
Corrective Action Required
07/07/2023
Erosion control around perimeter is needed
Miscellaneous Correction
Corrective Action Required
07/11/2023
Corrective actions for erosion control has not been successful. No inspections will be done until proper erosion control is completed. 07/11/2023. KBEARD
Occupancy Inspection - Codes Residential Failed 7/14/2023 7/14/2023 07/14/2023
Miscellaneous Correction
Corrective Action Required
07/07/2023
2121 - Garage to house stair has a riser to threshold at 7 3/4 inch and the next riser is at 7 1/8. Code is no more than a 3/8 riser difference - First tread riser from main floor to upstairs it greater than allowable 7 3/4 inches high - Washer/dryer does not have a anti water hammer devise installed - Sod is not installed - Splash blocks are not installed - Sump pump discharge must be 36 inches away from the foundation - Address erosion under the front porch entry sidewalk 2123 - Oven anti tip bracket is not working - Garage to house door self closing hinge is not working properly to seal and lock - Vertical boards above garage overhead door needs to be sealed - First step riser from wood floor to the stairwell is 8 1/4 inches in height. Code calls for a maximum riser height to be 7 3/4 inches - Fist step to second step in the stairwell is over the allowed height difference of 3/8 of an inch (8 1/4 to 7 5/8 inch) - Have newly placed electrical panel and old placement panel open for inspection - Electrical panel does not have clearance width of 30 inches E3405.2 - Washer/dryer does not have a anti water hammer devise installed - Exterior sump pump extension is not installed - A/C anti siphon knobs are not installed - Sod is not installed - Exterior splash pads are not installed 07/14/2023 KBEARD
Occupancy Inspection - Codes Residential Temporary C of O 7/24/2023 7/24/2023 07/24/2023
Miscellaneous Correction
Resolved
07/24/2023
2121 - Washer/dryer does not have a anti water hammer devise installed - Sod is not installed - Splash blocks are not installed - Sump pump discharge must be 36 inches away from the foundation - Address erosion under the front porch entry sidewalk 2123 - Vertical boards above garage overhead door needs to be sealed - Washer/dryer does not have a anti water hammer devise installed - Exterior sump pump extension is not installed - A/C anti siphon knobs are not installed - Sod is not installed - Exterior splash pads are not installed 07/14/2023 KBEARD
Erosion Control Inspection Residential Partial 7/24/2023 07/24/2023
Miscellaneous Correction
Corrective Action Required
07/11/2023
-2121 SW Osage needs erosion control along the east side of property
Miscellaneous Correction
Resolved
07/24/2023
Erosion control is still needed around the perimeter of the property. Erosion control along the east side of property has been noted before and has never been addressed. This is the third warning. This will be a two day warning that erosion control is needed and control measures need to be addressed before fees may be issued
Misc
Resolved
07/24/2023
Erosion control around perimeter is needed
Miscellaneous Correction
Resolved
07/24/2023
Corrective actions for erosion control has not been successful. No inspections will be done until proper erosion control is completed. 07/11/2023. KBEARD
Miscellaneous Correction
Corrective Action Required
07/24/2023
Erosion control is in place at time of TCO
Erosion Control Inspection Residential Passed 7/31/2023 07/31/2023
Miscellaneous Correction
Resolved
07/31/2023
-2121 SW Osage needs erosion control along the east side of property
Miscellaneous Correction
Resolved
07/31/2023
Erosion control is in place at time of TCO
Occupancy Inspection - Codes Residential Failed 7/31/2023 7/31/2023 07/31/2023
Miscellaneous Correction
Corrective Action Required
07/31/2023
- Water is standing against the East side of foundation at 2121 - Grading on East side of 2121 is not per plan - splash blocks and sump pump discharge extension are not installed - Water meter base is well above grade - 2123 splash blocks and sump pump discharge extension are not installed - Water meter base is well above grade - Water is standing against the foundations West side - Grading on West side of 2123 is not per plan
Plot Plan Inspection Failed 7/31/2023 07/31/2023
Miscellaneous Correction
Corrective Action Required
07/31/2023
- Grading on East side of 2121 is not per plan - Grading on West side of 2123 is not per plan
Occupancy Inspection - Codes Residential Failed 8/17/2023 8/17/2023 08/17/2023
Miscellaneous Correction
Corrective Action Required
07/31/2023
- Grading on East side of 2121 is not per approved plan. Water is standing in the lot adjacent to 2117 SW Osage and now has water standing on both properties - submit a revised plot plan for review after grading has been completed - 2123 - Grading on West side of 2123 is not per plan. Water is standing in the yard and will not properly drain. - submit a revised plot plan for review after grading has been completed
Occupancy Inspection - Codes Residential Not Ready 9/11/2023 9/11/2023 09/11/2023
Miscellaneous Correction
Resolved
09/11/2023
2121 - submit a revised plot plan for review after grading has been completed - 2123 - Grading on West side of 2123 is not per plan. - submit a revised plot plan for review after grading has been completed
Miscellaneous Correction
Corrective Action Required
09/11/2023
Both sides of the duplex have exposed dirt. Sod will need to be installed after dirt work to meet approved plot plan. Both sides are not ready for inspection and will have a not ready fee added. 09/11/2023 KBEARD 1:15pm
Plot Plan Inspection Passed 1/30/2024 01/30/2024
Miscellaneous Correction
Resolved
01/30/2024
- Grading on East side of 2121 is not per plan - Grading on West side of 2123 is not per plan
Occupancy Inspection - Codes Residential Full C of O 1/30/2024 1/31/2024 01/31/2024
Miscellaneous Correction
Resolved
01/31/2024
Both sides of the duplex have exposed dirt. Sod will need to be installed after dirt work to meet approved plot plan. Both sides are not ready for inspection and will have a not ready fee added. 09/11/2023 KBEARD 1:15pm
Documents & Images
Date Uploaded File Type Document Name
03/20/2023 Permit Codes Residential Plan Review
03/20/2023 Permit Codes Residential Plan Review
03/21/2023 OS #52 - PERMIT APP
03/22/2023 Plot Plan APPROVED PLOT PLAN
03/28/2023 Approved Plans APPROVED PLANS
03/28/2023 Approved Plans APPROVED TRUSS LAYOUT
03/28/2023 Approved Plans APPROVED TRUSS PACKAGE
03/28/2023 Permit Codes Residential Plan Review
03/28/2023 Permit Codes Residential Plan Review
04/06/2023 2121 & 2123 SW Osage Dr LSMO Osage Lot 52 Footing Inspection Report 4-6-23
04/07/2023 Permit DS Building Permit
04/07/2023 Permit DS Building Permit
04/07/2023 Receipt Receipt for transaction:2023-001940
04/13/2023 Approved Plans APPROVED TRUSS LAYOUT
04/13/2023 Approved Plans APPROVED TRUSS PACKAGE
04/14/2023 Letter INSPECTION SUMMARY
04/14/2023 Letter INSPECTION SUMMARY
04/14/2023 Letter INSPECTION SUMMARY
04/14/2023 Letter INSPECTION SUMMARY
04/14/2023 Letter INSPECTION SUMMARY
04/14/2023 Letter INSPECTION SUMMARY
04/14/2023 Letter INSPECTION SUMMARY
04/14/2023 Letter INSPECTION SUMMARY
04/14/2023 Letter INSPECTION SUMMARY
04/17/2023 Letter INSPECTION SUMMARY
04/17/2023 Letter INSPECTION SUMMARY
04/17/2023 Letter INSPECTION SUMMARY
04/17/2023 Letter INSPECTION SUMMARY
04/17/2023 Letter INSPECTION SUMMARY
05/10/2023 Letter INSPECTION SUMMARY
05/10/2023 Letter INSPECTION SUMMARY
05/15/2023 Letter INSPECTION SUMMARY
05/15/2023 Letter INSPECTION SUMMARY
05/15/2023 Letter INSPECTION SUMMARY
05/15/2023 Letter INSPECTION SUMMARY
05/16/2023 Letter INSPECTION SUMMARY
05/16/2023 Letter INSPECTION SUMMARY
05/16/2023 Letter INSPECTION SUMMARY
05/18/2023 Receipt Receipt for transaction:2023-003468
06/19/2023 Letter INSPECTION SUMMARY
06/23/2023 Letter INSPECTION SUMMARY
06/23/2023 Letter INSPECTION SUMMARY
06/27/2023 Letter INSPECTION SUMMARY
06/27/2023 Letter INSPECTION SUMMARY
07/07/2023 Letter INSPECTION SUMMARY
07/07/2023 Letter INSPECTION SUMMARY
07/07/2023 Letter INSPECTION SUMMARY
07/11/2023 Letter INSPECTION SUMMARY
07/14/2023 Letter INSPECTION SUMMARY
07/24/2023 Certificate/License Codes Temporary Certificate of Occupancy
07/24/2023 Letter INSPECTION SUMMARY
07/24/2023 Letter INSPECTION SUMMARY
07/31/2023 Letter INSPECTION SUMMARY
07/31/2023 Letter INSPECTION SUMMARY
07/31/2023 Letter INSPECTION SUMMARY
08/17/2023 Letter INSPECTION SUMMARY
09/11/2023 Letter INSPECTION SUMMARY
01/29/2024 Letter Codes 140 Day Letter
01/30/2024 Letter INSPECTION SUMMARY
01/30/2024 Receipt Receipt for transaction:2024-000484
01/31/2024 Letter Codes Final Certificate of Occupancy
01/31/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home