Permit Application Status

PRRES20222951


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20222951
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - COVERED AND UNCOVERED DECK - FINISHED AND UNFINISHED BASEMENT - SUSPENDED SLAB GARAGE
06/27/2022
07/03/2022
12/26/2022
05/30/2023
Locations
Contacts
TRUMARK HOMES, LLC, Address:PO BOX 728, Phone:(816) 564-5613  
MARK A YANCIK, Address:508 nw manor dr  
TRUMARKHOMES.MARK@GMAIL.COM  
C.M. MOSE & SON, Address:6603 ROYAL ST BLDG E, Phone:(816) 781-4707  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $600.00 $600.00 Paid 07/03/2022
Right of Way Permit Fee $85.00 $85.00 Paid 07/03/2022
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 07/03/2022
Water Tap Fee $3,655.00 $3,655.00 Paid 07/03/2022
Water Meter Fee $479.24 $479.24 Paid 07/03/2022
Valuation Fee New Single Family $1,550.48 $1,550.48 Paid 07/03/2022
Temporary Occupancy Fee $50.00 $50.00 Paid 03/22/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/4/2022 08/04/2022
Underslab Plumbing Inspection - Residential Passed 8/4/2022 8/4/2022 08/04/2022
Gas Service Inspection - Residential Failed 10/6/2022 10/6/2022 10/06/2022
Miscellaneous Correction
Corrective Action Required
10/06/2022
PROVIDE A WORKING GUAGE & PRESSURE FOR GAS TEST
Electrical Service Inspection Failed 10/6/2022 10/6/2022 10/06/2022
Miscellaneous Correction
Corrective Action Required
10/06/2022
SECURE SEC CABLE AT SERVICE PANEL
All Rough Inspection - Residential Failed 10/6/2022 10/6/2022 10/06/2022
Miscellaneous Correction
Resolved
10/06/2022
COPIED WRONG ADDRESS ON THIS LIST MY BAD Michael Harkins 10/06/2022 3:36 PM
All Rough Inspection - Residential Failed 10/6/2022 10/06/2022
Miscellaneous Correction
Corrective Action Required
10/06/2022
: 1ST TIME ALL ROUGH : Sister over notched stud at foundation wall bottom of stairs, bath 3, bed 3 East wall, storage East, -Seal penetration in fireblocking and through floor penetrations for ward flex furout wall -Tighten anchor bolts -Seal top plate penetration at furout wall west -Replace damaged stud and scabbed stud at (5) stud pack under beam at exterior corner -Use approved methods to fireblock ceiling line at bath/ family room -Fireblock ceiling line at family room/fitness -Pan off joist space and seal all penetrations in return air in family/bed 5 -Provide proper slope in dwv at bed 5 joist space -Seal top plate penetrations bed 3, bed 3 bath -Fireblock ceiling line bath 3 -Seal penetrations in return air pan in fitness -Fireblock ceiling line at fitness -Provide gas pressure-valve or gauge is faulty -Fireblock dead space at wrapping -Anchor column bases in suspended garage -complete blocking above beam at family -Provide (4) studs for beam bearing at Bed 3 -Provide proper connections for deck posts to beams -Address ledger to house connection at offset -Deck beam over spanned-7’ 11” max span allowed -Deck joists are over spanned- max span 14’ for 16” on center Install windows & Doors Repair or replace damage stud near plate break garage Secure SEC cable at service panel Seal upward penetrations above service panel & near 20 min door Nail top plate to header 3" OC garage portal per plans Provide electrical protection plates corner garage / master closet Seal upward penetration low volt throughout Provide 3 stud pack under LVL butler's pantry Provide boca plate DWV butlers pantry Seal gas line floor penetration at fireplace Seal upward penetrations office/ bed 2 Seal penetrations at air return plenums Provide flashing above horizontal trim when windows are installed Nail exterior wall sheathing per code
Electrical Service Inspection Passed 10/13/2022 10/13/2022 10/13/2022
Miscellaneous Correction
Resolved
10/13/2022
SECURE SEC CABLE AT SERVICE PANEL
Gas Service Inspection - Residential Passed 10/13/2022 10/13/2022 10/13/2022
Miscellaneous Correction
Resolved
10/13/2022
PROVIDE A WORKING GUAGE & PRESSURE FOR GAS TEST
All Rough Inspection - Residential Failed 10/13/2022 10/13/2022 10/13/2022
Miscellaneous Correction
Corrective Action Required
10/06/2022
2nd inspection -Fireblock ceiling line at family room/fitness -Pan off joist space and seal all penetrations in return air in family/bed 5 -Fireblock fitness room ceiling line -Provide proper connections for deck posts to beams -Address ledger to house connection at offset -Deck beam over spanned-7’ 11” max span allowed -Deck joists are over spanned- max span 14’ for 16” on center -Install windows & doors -Provide electrical protection plates corner garage / master closet /added studs left of service panel -Provide flashing above horizontal trim when windows installed -Nail exterior wall sheathing per code
All Rough Inspection - Residential Failed 10/17/2022 10/17/2022 10/17/2022
Miscellaneous Correction
Corrective Action Required
10/13/2022
2nd inspection 10/13/22 3rd INSPECTION 10/17/22 -Provide proper connections for deck posts to deck beams (2) 1/2" DIAMETER THROUGH-BOLTS OR APPROVED EQUIVALENT CONNECTO : per 2018 IRC FIGURE R507.5.1 (2) : -Deck beam over spanned-7’ 11” max span allowed -Deck joists are over spanned- max span 14’ for 16” on center -Install windows & doors -Provide flashing above horizontal trim when windows installed -Nail exterior wall sheathing per code
Suspended Slab Inspection Passed 10/20/2022 10/20/2022
Misc
Informational
10/20/2022
3RD PARTY BY DAVID AINSWORTH FRONT PORCH SUSPENDED SLAB UPLOADED TO PERMIT
Water Service Inspection - R Passed 10/27/2022 (1:15) 10/27/2022 10/27/2022
Sewer Service Inspection - R Passed 10/31/2022 (11:30) 10/31/2022 10/31/2022
Driveway Inspection Partial 1/3/2023 1/3/2023 01/03/2023
Misc
Corrective Action Required
01/03/2023
1-3-22 DP. Driveway is formed up and compacted. Sidewalk was not installed, contractor was informed and is correcting.
Driveway Inspection Passed 1/10/2023 1/10/2023 01/10/2023
Misc
Corrective Action Required
01/03/2023
1-3-22 DP. Driveway is formed up and compacted. Sidewalk was not installed, contractor was informed and is correcting. 1-10-22 RH. Driveway meets LS and ADA specification.
Sidewalk Inspection Passed 01/10/2023
Misc
Informational
01/10/2023
1-10-22 RH. Sidewalk meets LS and ADA specification.
All Rough Inspection - Residential Passed 3/20/2023 03/20/2023
Miscellaneous Correction
Resolved
03/20/2023
2nd inspection 10/13/22 3rd INSPECTION 10/17/22 -Provide proper connections for deck posts to deck beams (2) 1/2" DIAMETER THROUGH-BOLTS OR APPROVED EQUIVALENT CONNECTO : per 2018 IRC FIGURE R507.5.1 (2) : -Deck beam over spanned-7’ 11” max span allowed -Deck joists are over spanned- max span 14’ for 16” on center -Install windows & doors -Provide flashing above horizontal trim when windows installed -Nail exterior wall sheathing per code
Piers/Caissons Inspection - Residential Failed 3/20/2023 03/20/2023
Misc
Corrective Action Required
03/20/2023
Builder is missing the third party pier inspection letter
Erosion Control Inspection Residential Failed 3/20/2023 03/20/2023
Misc
Corrective Action Required
03/20/2023
Swaddles not installed
Occupancy Inspection - Codes Residential Failed 3/20/2023 03/20/2023
Misc
Corrective Action Required
03/20/2023
2125 NW O’Brien -Garage to panty door needs self closing hinges -Garage missing electrical plate cover -Bathroom near laundry not GFCI protected -Washer and dryer need water hammer devices -outlet covers in master bathroom missing -dishwasher missing water hammer device -sump pump outlet needs to be labeled non GFCI -hot water needs a discharge tube -GFCI in basement bathroom not working -basement patio door missing security screws -exterior of house needs to have siding to ground clearance of at least 6 inches -anti tamp knobs needed on A/C unit -exterior penetrations need sealing
Occupancy Inspection - Codes Residential Ready for Temp CO 3/22/2023 3/22/2023 03/22/2023
Misc
Resolved
03/22/2023
Sod not installed at time of re inspection
Plot Plan Inspection Passed 4/12/2023 04/12/2023
Occupancy Inspection - Codes Residential Temporary C of O 4/21/2023 04/21/2023
Miscellaneous Correction
Corrective Action Required
04/21/2023
The following needs to be finalized before a CO can be issued. -sod still needs to be installed -third part pier inspection needs to be obtained
Erosion Control Inspection Residential Passed 05/30/2023
Misc
Resolved
05/30/2023
Swaddles not installed
Piers/Caissons Inspection - Residential Passed 5/30/2023 05/30/2023
Misc
Informational
05/30/2023
PIERS INSPECTED BY THIRD PARTY.
Occupancy Inspection - Codes Residential Full C of O 5/30/2023 5/30/2023 05/30/2023
Miscellaneous Correction
Resolved
05/30/2023
Documents & Images
Date Uploaded File Type Document Name
06/28/2022 Permit Codes Residential Plan Review
06/29/2022 Permit Codes Residential Plan Review
06/30/2022 Plot Plan approved plot plan
06/30/2022 Approved Plans APPROVED PLANS
06/30/2022 SKM_C36822063017250
07/01/2022 Permit Codes Residential Plan Review
07/03/2022 Permit DS Building Permit
07/03/2022 Receipt Receipt for transaction:2022-005473
07/16/2022 2125 NW O'Brien Rd LSMO Woodside Ridge Lot 167 Pier Inspection Report 7-14-22
07/19/2022 M L Crose 2125 NW Obrien Rd LSMO Woodside Ridge Lot 167 Footing Inspection Report 7-18-22
07/21/2022 M L Crose 2125 NW Obrien Rd LSMO Woodside Ridge Lot 167 Wall Inspection Report 7-20-22
08/04/2022 Letter INSPECTION SUMMARY
08/04/2022 Letter INSPECTION SUMMARY
08/18/2022 2125 NW Obrien Rd LSMO Lot 167 Woodside Reserve Structural Slab Inspection Report 8-15-22
10/06/2022 Letter INSPECTION SUMMARY
10/06/2022 Letter INSPECTION SUMMARY
10/06/2022 Letter INSPECTION SUMMARY
10/13/2022 Letter INSPECTION SUMMARY
10/13/2022 Letter INSPECTION SUMMARY
10/13/2022 Letter INSPECTION SUMMARY
10/13/2022 Letter INSPECTION SUMMARY
10/17/2022 Letter INSPECTION SUMMARY
10/19/2022 2125 NW Obrien Rd LSMO Lot 167 Woodside Reserve Front Porch Structural Slab Inspection Report 10-18-22
10/20/2022 Letter INSPECTION SUMMARY
10/27/2022 Letter INSPECTION SUMMARY
10/31/2022 Letter INSPECTION SUMMARY
12/08/2022 Approved Plans approved page 2 of plans
01/03/2023 Letter INSPECTION SUMMARY
01/10/2023 Letter INSPECTION SUMMARY
01/10/2023 Letter INSPECTION SUMMARY
03/20/2023 NextDocument (214) pier drawing lot 167 woodside
03/20/2023 Approved Plans APPROVED BASEMENT PIER PLAN
03/20/2023 Letter INSPECTION SUMMARY
03/20/2023 Letter INSPECTION SUMMARY
03/20/2023 Letter INSPECTION SUMMARY
03/20/2023 Letter INSPECTION SUMMARY
03/22/2023 Certificate/License Codes Temporary Certificate of Occupancy
03/22/2023 Receipt Receipt for transaction:2023-001613
04/10/2023 NextDocument (324) RETAINING WALL LOT 167 WOODSIDE ENGINEERING DESIGN
04/11/2023 NextDocument (342) 167 AS BUILT
04/11/2023 Plot Plan approved as graded plot plan
04/12/2023 Letter INSPECTION SUMMARY
04/21/2023 Certificate/License Codes Temporary Certificate of Occupancy
05/30/2023 Letter Codes Final Certificate of Occupancy
05/30/2023 Letter Field Certificate of Occupancy
05/30/2023 Letter INSPECTION SUMMARY
05/30/2023 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home