Summary
PRRES20215184
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK STOP WORK ORDER generated on 04/05/2022 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 06/06/2022 12:00 AM by username 'Mitchell Schwarz'.
10/05/2021
10/11/2021
04/03/2022
06/01/2023
Locations
Contacts
WALKER CUSTOM HOMES, LLC, Address:PO BOX 3194, Phone:(913) 208-2026  
Jason walker, Address:PO Box 247, Phone:(913) 208-2026  
R-MECH HEATING COOLING PLUMBING/RHODES HEATING COOLING PLUMBING AND ROOTER, Address:1425 AGNES AVE, Phone:(816) 920-5955  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $570.00 $570.00 Paid 10/11/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 10/11/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 10/11/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/11/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 10/11/2021
9110078-Valuation Fee New Single Family $1,404.01 $1,404.01 Paid 10/11/2021
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/07/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/21/2021 (1:30) 10/21/2021 10/21/2021
Underslab Plumbing Inspection - Residential Passed 11/4/2021 11/4/2021 11/04/2021
Water Service Inspection - R Partial 12/6/2021 12/6/2021 12/06/2021
Sewer Service Inspection - R Passed 12/6/2021 (10:15) 12/6/2021 12/06/2021
Water Service Inspection - R Passed 12/7/2021 12/07/2021
Erosion Control Inspection Residential Failed 3/24/2022 03/24/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/24/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed - Stop Work 4/5/2022 04/05/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/24/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
04/05/2022
Erosion control still not in compliance stop work issued address erosion control at back of lot Mitchell Schwarz 04/05/2022 3:25 PM
Erosion Control Inspection Residential Partial 6/6/2022 6/6/2022 06/06/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
06/06/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Resolved
06/06/2022
Erosion control still not in compliance stop work issued address erosion control at back of lot Mitchell Schwarz 04/05/2022 3:25 PM
Misc
Informational
06/06/2022
erosion conrol in compliance at time of inspection
Gas Service Inspection - Residential Passed 6/6/2022 6/6/2022 06/06/2022
Electrical Service Inspection Passed 6/6/2022 6/6/2022 06/06/2022
All Rough Inspection - Residential Failed 6/6/2022 6/6/2022 06/06/2022
Misc
Corrective Action Required
06/06/2022
Provide CITY STAMPED plans on site for inspection.
All Rough Inspection - Residential Failed 6/14/2022 6/14/2022 06/14/2022
Misc
Resolved
06/14/2022
Provide CITY STAMPED plans on site for inspection.
Misc
Corrective Action Required
06/14/2022
-complete garage portal frame nailing (make sure nailing to header nailing in exposed as well -all anchor bolts to be within the middle 1/3 of sill plate -furr down return air for insulation in garage -complete all bath vents -fire block furr out wall in garage for dwv (when using Unfaced insulation it must be packed tightly and securely in place) -complete furr down in kitchen -missing nails in hangers above kitchen -address notched lvl header above rear slider -uncover/complete S3.2 10 detail at slider area -address rear great room windows not framed to plans -address joist above master (holes closer than 2” -complete plumbing for master tub -fireblock at master walk in closet window -frame front door to plans -address rafters landing on blocks and 2nd floor -address rafter to ceiling joist connection above front entry -address over notched ceiling joists and rafter bearing at bed 2/3 bath -address over notched floor joists under master shower -seal return air panning near egress window in basement -seal gaps in return air panning end above beam in basement near E wall
All Rough Inspection - Residential Not Ready 7/28/2022 7/28/2022 07/28/2022
Misc
Corrective Action Required
06/14/2022
-complete garage portal frame nailing (nail top plate to header per plans and design -all anchor bolts to be within the middle 1/3 of sill plate(could not inspect insulated) -furr down return air for insulation in garage(could not inspect fire blocking of this because of insulation) -complete all bath vents -fire block furr out wall in garage for dwv (when using Unfaced insulation it must be packed tightly and securely in place) could not inspect due to insulation -address notched lvl header above rear slider could not inspect due to insulation -uncover/complete S3.2 10 detail at slider area not completed -address rear great room windows not framed to plans (could not inspect engineer fix due to covering) -complete plumbing for master tub -frame front door to plans -address rafters landing on blocks and 2nd floor -address rafter to ceiling joist connection above front entry -address over notched ceiling joists and rafter bearing at bed 2/3 bath -address over notched floor joists under master shower -seal return air panning near egress window in basement -seal gaps in return air panning end above beam in basement near E wall Uncover all 2nd floor items
All Rough Inspection - Residential Failed 8/9/2022 8/9/2022 08/09/2022
Misc
Corrective Action Required
07/28/2022
-complete all bath vents -address notched lvl header above rear slider could not inspect due to insulation -uncover/complete S3.2 10 detail at slider area not completed -complete plumbing for master tub -address rafters landing on blocks at 2nd floor -address rafter to ceiling joist connection above front entry -address over notched ceiling joists and rafter bearing at bed 2/3 bath -address over notched floor joists under master shower -seal return air panning near egress window in basement -seal gaps in return air panning end above beam in basement near E wall Uncover all covered items Do not dry wall Do not insulate
All Rough Inspection - Residential Passed 8/31/2022 8/31/2022 08/31/2022
Misc
Resolved
08/31/2022
-complete plumbing for master tub -address rafters landing on blocks at 2nd floor -address rafter to ceiling joist connection above front entry -address over notched floor joists under master shower -seal return air panning near egress window in basement Uncover all covered items Do not dry wall Do not insulate
Driveway Inspection Partial 9/12/2022 9/12/2022 09/12/2022
Misc
Informational
09/12/2022
9-12-22 RH. Driveway was formed up and aggregate was placed and compacted.
Sidewalk Inspection Partial 9/12/2022 9/12/2022 09/12/2022
Misc
Informational
09/12/2022
9-12-22 RH. Sidewalk was formed and aggregate was placed compacted.
Sidewalk Inspection Passed 9/20/2022 9/20/2022 09/20/2022
Misc
Informational
09/20/2022
9-20-22 RH. Sidewalk was not called in for sub grade inspection. Sidewalk does meet LS and ADA specification.
Driveway Inspection Passed 9/19/2022 9/19/2022 09/20/2022
Misc
Informational
09/12/2022
9-12-22 RH. Driveway was formed up and aggregate was placed and compacted. 9-20-22 RH. Driveway meets LS and ADA Specification.
Erosion Control Inspection Residential Failed 4/12/2023 04/12/2023
Misc
Resolved
04/12/2023
erosion conrol in compliance at time of inspection
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/12/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Plot Plan Inspection Passed 4/13/2023 04/13/2023
Occupancy Inspection - Codes Residential Failed 4/13/2023 4/13/2023 04/13/2023
Misc
Corrective Action Required
04/13/2023
No further inspections until erosion control is in compliance -address pending pier inspection -sod -splash blocks and sump pump discharge to extend 36” from foundation -will check water meter at time of sod -address to be of contrasting color and properly illuminated -handrail in garage required -provide spark rings at kitchen outlets as required by code -secondary locking device at rear slider -seal all exterior penetrations -tamper caps at A/c compressor -spark ring at outlet above fireplace -shear off set screw at water anti syphon device
Occupancy Inspection - Codes Residential Ready for Temp CO 5/5/2023 5/5/2023 05/05/2023
Misc
Resolved
05/05/2023
Piers/Caissons Inspection - Residential Passed 6/1/2023 06/01/2023
Erosion Control Inspection Residential Passed 6/1/2023 06/01/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
06/01/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Full C of O 6/1/2023 06/01/2023
Documents & Images
Date Uploaded File Type Document Name
10/05/2021 2022 SW Farmfield Ct Application Documents
10/05/2021 Permit Codes Residential Plan Review
10/11/2021 Plot Plan Approved Plot Plan
10/11/2021 Approved Plans Approved Drawings
10/11/2021 Permit Codes Residential Plan Review
10/11/2021 Permit DS Building Permit
10/11/2021 Receipt Receipt for transaction:2021-007891
10/21/2021 Letter INSPECTION SUMMARY
11/04/2021 Letter INSPECTION SUMMARY
12/06/2021 Letter INSPECTION SUMMARY
12/06/2021 Letter INSPECTION SUMMARY
12/07/2021 Letter INSPECTION SUMMARY
03/24/2022 Letter INSPECTION SUMMARY
04/05/2022 Letter Stop Work Order
06/06/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/14/2022 Letter INSPECTION SUMMARY
07/27/2022 2022 SW Farm Field Ln_ (Lot 5) - Inspection Letter (7-11-22)
07/28/2022 Letter INSPECTION SUMMARY
08/08/2022 2022 SW Farm Field Ln_ (Lot 5) - Inspection Letter (8-8-22)
08/09/2022 Letter INSPECTION SUMMARY
08/25/2022 2022 Farm Field Lane - Structural Letter (August 25, 2022)
08/31/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
09/20/2022 Letter INSPECTION SUMMARY
09/20/2022 Letter INSPECTION SUMMARY
12/07/2022 2022 SW Farm Field LN ROW
12/07/2022 Receipt Receipt for transaction:2022-009354
02/07/2023 Letter Codes 140 Day Letter
03/20/2023 Letter Codes 180 Day Letter
03/29/2023 180 Day letter template
03/29/2023 TCO request Form
04/12/2023 Letter INSPECTION SUMMARY
04/13/2023 Letter INSPECTION SUMMARY
04/13/2023 Letter INSPECTION SUMMARY
04/14/2023 2022 Farmfield Pier Inspection
06/01/2023 Letter Codes Final Certificate of Occupancy
06/01/2023 Letter Field Certificate of Occupancy
06/01/2023 Letter INSPECTION SUMMARY
06/01/2023 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home