Permit Application Status

PRRES20215083


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20215083
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. COVERED DECK. WALKOUT BASEMENT. STOP WORK ORDER generated on 03/29/2022 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 06/29/2022 12:00 AM by username 'Mitchell Schwarz'.
09/28/2021
10/27/2021
03/30/2022
01/23/2023
Locations
Contacts
IQ CONSTRUCTION, Address:P O BOX 6423, Phone:(816) 582-8100  
Jennifer Pestka, Address:p o box 6423  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
SAFEHOUSE ELECTRIC COMPANY, Address:P O BOX 1833, Phone:(816) 935-8113  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $390.00 $390.00 Paid 10/27/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 10/27/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 10/27/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/27/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 10/27/2021
9110078-Valuation Fee New Single Family $1,058.24 $1,058.24 Paid 10/27/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/27/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 07/27/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 10/12/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 10/12/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 11/02/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 12/02/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/23/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/10/2021 (2:45) 11/10/2021 11/10/2021
Underslab Plumbing Inspection - Residential Passed 12/30/2021 12/30/2021 12/30/2021
Erosion Control Inspection Residential Failed 12/30/2021 12/30/2021
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
12/30/2021
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. IF EROSION CONTROL IS NOT IN COMPLIANCE STOP WORK WILL BE ISSUED -EROSION CONTROL AT BACK OF LOT
Erosion Control Inspection Residential Not Ready 1/5/2022 01/05/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
12/30/2021
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. IF EROSION CONTROL IS NOT IN COMPLIANCE STOP WORK WILL BE ISSUED -EROSION CONTROL AT BACK OF LOT
Sewer Service Inspection - R Passed 3/16/2022 (11:30) 3/16/2022 03/16/2022
Water Service Inspection - R Passed 3/17/2022 (1:00) 3/17/2022 03/17/2022
Erosion Control Inspection Residential Failed 3/17/2022 03/17/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
03/17/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. IF EROSION CONTROL IS NOT IN COMPLIANCE STOP WORK WILL BE ISSUED -EROSION CONTROL AT BACK OF LOT
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/17/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed - Stop Work 3/29/2022 03/29/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/17/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
03/29/2022
Erosion control still not in compliance stop work issued
Erosion Control Inspection Residential Partial 6/29/2022 6/29/2022 06/29/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
06/29/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Resolved
06/29/2022
Erosion control still not in compliance stop work issued
Misc
Informational
06/29/2022
erosion control in compliance at time of inspection
Gas Service Inspection - Residential Failed 7/1/2022 7/1/2022 06/30/2022
Misc
Corrective Action Required
06/30/2022
complete gas line at fire place.
Electrical Service Inspection Passed 7/1/2022 7/1/2022 06/30/2022
All Rough Inspection - Residential Failed 6/30/2022 6/30/2022 06/30/2022
Misc
Corrective Action Required
06/30/2022
-Top plate to header at pfg per plans/ design -complete furr out wall in laundry -fire block master / great room wall to ceiling space -fire block fire place to ceiling space -secure and protect gas line at fire place -complete gas line installation -uncover and complete s3.2 10 connection at deck -uncover covered deck for inspection -fire block foyer wall to ceiling space see dwv penetration -mid way strap all dwv 2” or less in stud spaces -install all windows and doors -anchor all steel columns in basement -front entry wall not tied to abutting exterior walls
All Rough Inspection - Residential Failed 7/21/2022 7/21/2022 07/21/2022
Misc
Corrective Action Required
06/30/2022
-complete furr out wall in laundry and fire block -fire block master / great room wall to ceiling space seal gaps see master entry -secure and protect gas line at fire place -complete gas line installation OK to insulate do not cover any items still in need of inspection
Gas Service Inspection - Residential Not Ready 7/21/2022 7/21/2022 07/21/2022
Misc
Corrective Action Required
06/30/2022
complete gas line at fire place.
All Rough Inspection - Residential Passed 7/27/2022 7/27/2022 07/27/2022
Misc
Resolved
07/27/2022
-complete furr out wall in laundry and fire block -fire block master / great room wall to ceiling space seal gaps see master entry -secure and protect gas line at fire place -complete gas line installation OK to insulate do not cover any items still in need of inspection
Gas Service Inspection - Residential Failed 7/27/2022 7/27/2022 07/27/2022
Misc
Resolved
07/27/2022
complete gas line at fire place.
Misc
Corrective Action Required
07/27/2022
Bond gas line, pressure okay
Piers/Caissons Inspection - Residential Not Ready 8/8/2022 (10:15) 8/8/2022 08/08/2022
Misc
Corrective Action Required
08/08/2022
No address no piers drilled
Piers/Caissons Inspection - Residential Passed 8/8/2022 (1:00) 8/8/2022 08/08/2022
Misc
Resolved
08/08/2022
No address no piers drilled
Gas Service Inspection - Residential Failed 8/23/2022 8/23/2022 08/23/2022
Misc
Corrective Action Required
07/27/2022
Bond gas line, pressure okay
Misc
Corrective Action Required
08/23/2022
could not inspect crew working on stairwell could not access basement
Driveway Inspection Partial 9/8/2022 9/8/2022 09/08/2022
Misc
Informational
09/08/2022
9-8-22 RH. Driveway is formed up and aggregate is placed and compacted.
Sidewalk Inspection Not Ready 9/21/2022 9/21/2022 09/21/2022
Misc
Informational
09/21/2022
9-21-22 RH. Sidewalk was not finished graded and aggregate was not compacted.
Sidewalk Inspection Partial 9/28/2022 9/28/2022 09/28/2022
Misc
Informational
09/21/2022
9-21-22 RH. Sidewalk was not finished graded and aggregate was not compacted. 9-28-22 RH. Sidewalk is formed up and aggregate is placed and compacted.
Driveway Inspection Passed 9/28/2022 09/28/2022
Misc
Informational
09/08/2022
9-8-22 RH. Driveway is formed up and aggregate is placed and compacted. 9-28-22 RH. Driveway meets LS and ADA specification.
Sidewalk Inspection Passed 10/5/2022 10/5/2022 10/05/2022
Misc
Informational
10/05/2022
9-28-22 RH. Sidewalk is formed up and aggregate is placed and compacted. 10-5-22 RH. Sidewalk meets LS and ADA Specification.
Gas Service Inspection - Residential Passed 10/12/2022 10/12/2022 10/12/2022
Misc
Resolved
10/12/2022
Bond gas line, pressure okay
Misc
Resolved
10/12/2022
could not inspect crew working on stairwell could not access basement
Plot Plan Inspection Passed 10/18/2022 10/18/2022
Erosion Control Inspection Residential Passed 11/1/2022 11/1/2022 11/01/2022
Misc
Resolved
11/01/2022
erosion control in compliance at time of inspection
Occupancy Inspection - Codes Residential Failed 11/1/2022 11/1/2022 11/01/2022
Misc
Corrective Action Required
11/01/2022
-gutters and downspouts required -splash blocks at downspouts and sump pump discharge, 36" discharge from foundation -provide gravel base at water meter pit -provide (2) 1/2” through bolts each post/beam connection at deck -provide angle clips at outer ply of beam deck -provide vegetation at rear of lot disturbed by construction -security screws at rear deck doors, provide (2) 3" screws each hinge and strike plate -min 6’8” head clearance required at basement stairs R311.7.2 -exterior light fixture at rear patio must be sealed type fixture, less than 8’ AFF
Occupancy Inspection - Codes Residential Ready for Temp CO 11/2/2022 11/2/2022 11/02/2022
Misc
Corrective Action Required
11/01/2022
-gutters and downspouts required -splash blocks at downspouts and sump pump discharge, 36" discharge from foundation -provide (2) 1/2” through bolts each post/beam connection at deck -provide angle clips at outer ply of beam deck -provide vegetation at rear of lot disturbed by construction
Occupancy Inspection - Codes Residential Ready for Temp CO 12/2/2022 12/02/2022
Misc
Corrective Action Required
11/02/2022
-gutters and downspouts required -splash blocks at downspouts and sump pump discharge, 36" discharge from foundation -provide (2) 1/2” through bolts each post/beam connection at deck -provide angle clips at outer ply of beam deck -provide vegetation at rear of lot disturbed by construction
Occupancy Inspection - Codes Residential Full C of O 1/23/2023 1/23/2023 01/23/2023
Misc
Resolved
01/23/2023
-gutters and downspouts required -splash blocks at downspouts and sump pump discharge, 36" discharge from foundation -provide (2) 1/2” through bolts each post/beam connection at deck -provide angle clips at outer ply of beam deck -provide vegetation at rear of lot disturbed by construction
Documents & Images
Date Uploaded File Type Document Name
09/28/2021 4811_001
09/28/2021 4812_001
10/01/2021 Approved Plans APPROVED DRAWINGS
10/01/2021 Permit Codes Residential Plan Review
10/07/2021 Plot Plan APPROVED PLOT PLAN
10/07/2021 Permit Codes Residential Plan Review
10/27/2021 Permit DS Building Permit
10/27/2021 Receipt Receipt for transaction:2021-008302
11/10/2021 Letter INSPECTION SUMMARY
12/30/2021 Letter INSPECTION SUMMARY
12/30/2021 Letter INSPECTION SUMMARY
01/05/2022 Letter INSPECTION SUMMARY
03/16/2022 Letter INSPECTION SUMMARY
03/17/2022 Letter INSPECTION SUMMARY
03/17/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter Stop Work Order
06/27/2022 Receipt Receipt for transaction:2022-005158
06/29/2022 Letter INSPECTION SUMMARY
06/30/2022 Letter INSPECTION SUMMARY
06/30/2022 Letter INSPECTION SUMMARY
06/30/2022 Letter INSPECTION SUMMARY
07/20/2022 Hook Farms Lot 27 - Uncover and complete s3_2 10 connection at deck
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 2031 SW Hook Farm Dr - Left Side s3_2 10 - strap not visible due to roof
07/21/2022 2031 SW Hook Farm Dr - Right Side s3_2 10 - strap not visible due to roof
07/27/2022 Receipt Receipt for transaction:2022-006143
07/27/2022 Letter INSPECTION SUMMARY
07/27/2022 Letter INSPECTION SUMMARY
08/08/2022 Letter INSPECTION SUMMARY
08/08/2022 Letter INSPECTION SUMMARY
08/23/2022 Letter INSPECTION SUMMARY
09/08/2022 Letter INSPECTION SUMMARY
09/21/2022 Letter INSPECTION SUMMARY
09/28/2022 Letter INSPECTION SUMMARY
09/28/2022 Letter INSPECTION SUMMARY
10/05/2022 Letter INSPECTION SUMMARY
10/12/2022 Receipt Receipt for transaction:2022-008201
10/17/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
11/01/2022 Letter INSPECTION SUMMARY
11/01/2022 Letter INSPECTION SUMMARY
11/02/2022 Letter INSPECTION SUMMARY
11/02/2022 Letter INSPECTION SUMMARY
11/02/2022 Certificate/License Codes Temporary Certificate of Occupancy
11/02/2022 Receipt Receipt for transaction:2022-008656
12/02/2022 2031 SW HOOK FARM - EXTENSION FORM
12/02/2022 Certificate/License Codes Temporary Certificate of Occupancy
12/02/2022 Receipt Receipt for transaction:2022-009250
01/23/2023 Certificate/License Codes Temporary Certificate of Occupancy
01/23/2023 Receipt Receipt for transaction:2023-000420
01/23/2023 Letter Field Certificate of Occupancy
01/23/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home