Permit Application Status

PRRES20215066


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20215066
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW 3 OR 4 FAMILY
NEW FOURPLEX. FINISHED BASEMENT. UNCOVERED DECK. ROOF TRUSSES.
09/28/2021
10/08/2021
03/28/2022
12/20/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New 3 or 4 Family $3,047.99 $3,047.99 Paid 10/08/2021
8331507-Sewer Connection Fee $1,440.00 $1,440.00 Paid 10/08/2021
8331401-Water Tap Fee $14,620.00 $14,620.00 Paid 10/08/2021
8350015-Water Meter Fee $1,916.96 $1,916.96 Paid 10/08/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/08/2021
7232302-Residential Excise Tax Fee $4,308.48 $4,308.48 Paid 10/08/2021
8331504-EFHB Middle Big Creek, Full $1,607.04 $1,607.04 Paid 10/08/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/05/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 10/05/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 10/05/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 10/05/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 10/05/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 10/05/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 10/05/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/07/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 12/13/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 12/13/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/29/2021 12/29/2021 12/29/2021
Misc
Informational
12/29/2021
APPROVED PER DAVID P AINSWORTH 12/27/21
Underslab Plumbing Inspection - Residential Not Ready 3/10/2022 3/10/2022 03/10/2022
Misc
Corrective Action Required
03/10/2022
INSPECTION DENIED - POST ADDRESSES -UNABLE TO INSPECT DWV WASTE DUE TO SNOW COVER, RESCHEDULE WHEN CONDITIONS ALLOW FOR A FULL INSPECTION OF UNDERSLAB PLUMBING
Underslab Plumbing Inspection - Residential Passed 3/15/2022 3/15/2022 03/15/2022
Misc
Resolved
03/15/2022
INSPECTION DENIED - POST ADDRESSES -UNABLE TO INSPECT DWV WASTE DUE TO SNOW COVER, RESCHEDULE WHEN CONDITIONS ALLOW FOR A FULL INSPECTION OF UNDERSLAB PLUMBING
Sewer Service Inspection - R Partial 3/28/2022 03/28/2022
Misc
Corrective Action Required
03/28/2022
2102, 2104 OK
Sewer Service Inspection - R Partial 3/29/2022 (9:30) 3/29/2022 03/29/2022
Misc
Corrective Action Required
03/28/2022
2102, 2104, 2106 OK
Sewer Service Inspection - R Passed 3/29/2022 3/29/2022 03/29/2022
Misc
Corrective Action Required
03/29/2022
2102, 2104, 2106, 2108 OK
Water Service Inspection - R Partial 4/4/2022 (11:30) 4/4/2022 04/04/2022
Misc
Corrective Action Required
04/04/2022
2108, 2106, 2104, 2102 - PARTIAL INSPECTION ON CONNECTION TO MAIN, METER WELL, AND COPPER TAIL, OK TO COVER INSPECTED **RECALL FOR INSPECTION WHEN READY PEX TO HOUSE AND PEX TO COPPER TAIL CONNECTION**
Gas Service Inspection - Residential Failed 8/23/2022 8/23/2022 08/23/2022
Misc
Corrective Action Required
08/23/2022
UNIT 2102: OK UNIT 2104: OK UNIT 2106, 2108 NOT INSPECTED
Electrical Service Inspection Failed 8/23/2022 8/23/2022 08/23/2022
Misc
Corrective Action Required
08/23/2022
UNIT 2102: -remove panel bonding screw from sub panel UNIT 2104: INTERIOR OK UNITS 2106, 2108 AND EXTERIOR SERVICE NOT INSPECTED
Rated Assembly Inspection Failed 8/23/2022 8/23/2022 08/23/2022
Misc
Corrective Action Required
08/23/2022
UNIT 2102: -firecaulk at SE cable conduit rock penetration UNIT 2104: -firecaulk at SE cable conduit rock penetration UNITS 2106, 2108 NOT INSPECTED
All Rough Inspection - Residential Failed 8/23/2022 8/23/2022 08/23/2022
Misc
Corrective Action Required
08/23/2022
UNIT 2102: -support furnace intake and exhaust pipes at garage -provide stud shoe at stud garage north wall bored for DWV -all walls 12’ or more to be Douglas fir 2x6 per plans -support and secure SE cables at basement -protect service panel from pex water lines above -remove panel bonding screw from sub panel -seal top plate penetration at basement bedroom -firecaulk at SE cable conduit rock penetration -repair damaged exterior sheathing at great room exterior wall UNIT 2104: -support furnace intake and exhaust pipes at garage -all walls 12’ or more to be Douglas fir 2x6 per plans -land NM to box at great room wall -seal top plate penetration at great room -nail off stud shoe at laundry -provide (2) nails at LIB bracing each plate/stud 2nd floor -provide protection plate for DWV stud penetration at master shower -(3) 2x12 header at basement slider per plans -firecaulk at SE cable conduit rock penetration -provide nailing at exterior sheathing CS-PF per the design in plans/IRC R602.10.6.4, 3” oc grid nailing is at the header not the rim joist UNITS 2106,2108 NOT INSPECTED
Electrical Service Inspection Passed 8/29/2022 8/29/2022 08/29/2022
Misc
Resolved
08/29/2022
Rated Assembly Inspection Passed 8/29/2022 8/29/2022 08/29/2022
Misc
Resolved
08/29/2022
Gas Service Inspection - Residential Failed 8/29/2022 8/29/2022 08/29/2022
Misc
Corrective Action Required
08/23/2022
UNIT 2102: OK UNIT 2104: OK UNIT 2106: OK UNIT 2108: REPLACE DEFECTIVE GAUGE FOR GAS PRESSURE TEST
All Rough Inspection - Residential Failed 8/29/2022 8/29/2022 08/29/2022
Misc
Corrective Action Required
08/23/2022
UNIT 2102: -provide stud shoe at stud garage north wall bored for DWV (nail off stud shoes) -protect service panel from pex water lines above (not complete, trade on site working at time of inspection) -repair damaged exterior sheathing at great room exterior wall UNIT 2104: -nail off stud shoe at laundry UNIT 2106: -address overnotched floor joist(s) at East garage for DWV and trap -support bath exhaust flex garage -address broken truss above laundry 2nd floor -address dbl 2x10 joist overbored and noted less than 2” from end of joist for DWV at crawl space beneath front entry -(3) 2x12 header at basement den slider per plans UNIT 2108: -fur out and protect NM secured at I beam garage -address joists bores less than 2” from end of joist and bores less than 2” apart for electrical at garage -(3) 2x12 header at basement slider per plans -provide joist hanger at joist basement crawl space, joist over 4’ and not supported 1 1/2” on plate -pex water line above service panel -replace defective gauge for gas pressure test
Erosion Control Inspection Residential Failed 8/29/2022 8/29/2022 08/29/2022
Misc
Corrective Action Required
08/29/2022
RESTORE AND MAINTAIN EROSION CONTROL ON LOT
Driveway Inspection Partial 8/30/2022 8/30/2022 08/30/2022
Misc
Informational
08/30/2022
8-30-22 RH. Driveways were formed up and aggregate was placed and compacted for Townhouse A-D.
Sidewalk Inspection Partial 8/30/2022 8/30/2022 08/30/2022
Misc
Informational
08/30/2022
8-30-22 RH. Sidewalk was formed up and aggregate was placed and compacted.
All Rough Inspection - Residential Not Ready 9/1/2022 9/1/2022 09/01/2022
Misc
Corrective Action Required
08/29/2022
UNIT 2102: -provide stud shoe at stud garage north wall bored for DWV (nail off stud shoes) -protect service panel from pex water lines above (not complete, trade on site working at time of inspection) -repair damaged exterior sheathing at great room exterior wall UNIT 2104: Ok UNIT 2106: -address overnotched floor joist(s) at East garage for DWV and trap (no letter for fix) -support bath exhaust flex garage -address broken truss above laundry 2nd floor (no letter for fix) -address dbl 2x10 joist overbored and noted less than 2” from end of joist for DWV at crawl space beneath front entry(no letter for fix) UNIT 2108: -address joists bores less than 2” from end of joist and bores less than 2” apart for electrical at garage(no letter for fix) -protect service panel from pex water lines above
Gas Service Inspection - Residential Passed 9/1/2022 9/1/2022 09/01/2022
Misc
Resolved
09/01/2022
UNIT 2102: OK UNIT 2104: OK UNIT 2106: OK UNIT 2108: REPLACE DEFECTIVE GAUGE FOR GAS PRESSURE TEST
All Rough Inspection - Residential Failed 9/2/2022 9/2/2022 09/02/2022
Misc
Corrective Action Required
09/01/2022
UNIT 2102: -provide stud shoe at stud garage north wall bored for DWV (nail off stud shoes) -protect service panel from pex water lines above UNIT 2104: Ok UNIT 2106: Ok UNIT 2108: -protect service panel from pex water lines above
All Rough Inspection - Residential Passed 9/2/2022 9/2/2022 09/02/2022
Misc
Resolved
09/02/2022
Sidewalk Inspection Failed 09/06/2022
Misc
Informational
08/30/2022
8-30-22 RH. Sidewalk was formed up and aggregate was placed and compacted. 9-6-22 RH. Sidewalk already has cracks on 3 panels. There was no expansion joints between any of the sidewalk and approaches.
Driveway Inspection Passed 9/6/2022 9/6/2022 09/06/2022
Misc
Informational
08/30/2022
8-30-22 RH. Driveways were formed up and aggregate was placed and compacted for Townhouse A-D. 9-6-22 RH. Driveway passes LS and ADA specification.
All Rough Inspection - Residential Failed 9/12/2022 9/12/2022 09/12/2022
Misc
Corrective Action Required
09/12/2022
PROVIDE SCREW PATTERN AT ALL GB BRACED LOCATIONS PER PLANS/ IRC R60210.4, 7" OC EDGES (INCLUDING TOP AND BOTTOM PLATES) AND 7" OC FIELD
All Rough Inspection - Residential Not Ready 9/13/2022 9/13/2022 09/13/2022
Misc
Corrective Action Required
09/12/2022
PROVIDE SCREW PATTERN AT ALL GB BRACED LOCATIONS PER PLANS/ IRC R60210.4, 7" OC EDGES (INCLUDING TOP AND BOTTOM PLATES) AND 7" OC FIELD UNIT 2102: SEE ABOVE, SCREW PATTERN PER GB BRACING DESIGN UNIT 2104: NOT READY FOR INSPECTION, HOUSE BEING ROCKED AT TIME OF INSPECTION
All Rough Inspection - Residential Failed 9/14/2022 9/14/2022 09/14/2022
Misc
Corrective Action Required
09/13/2022
UNIT 2102: OK UNIT 2104: PROVIDE SCREW PATTERN AT ALL GB BRACED LOCATIONS PER PLANS/ IRC R602.10.4, 7" OC EDGES (INCLUDING TOP AND BOTTOM PLATES) AND 7" OC FIELD UNIT 2108: PROVIDE SCREW PATTERN AT ALL GB BRACED LOCATIONS PER PLANS/ IRC R602.10.4, 7" OC EDGES (INCLUDING TOP AND BOTTOM PLATES) AND 7" OC FIELD
All Rough Inspection - Residential Not Ready 9/15/2022 9/15/2022 09/15/2022
Misc
Corrective Action Required
09/14/2022
UNIT 2102: OK UNIT 2104: OK UNIT 2106: PROVIDE SCREW PATTERN AT ALL GB BRACED LOCATIONS PER PLANS/ IRC R602.10.4, 7" OC EDGES (INCLUDING TOP AND BOTTOM PLATES) AND 7" OC FIELD UNIT 2108: PROVIDE SCREW PATTERN AT ALL GB BRACED LOCATIONS PER PLANS/ IRC R602.10.4, 7" OC EDGES (INCLUDING TOP AND BOTTOM PLATES) AND 7" OC FIELD
All Rough Inspection - Residential Not Ready 9/16/2022 9/16/2022 09/16/2022
Misc
Corrective Action Required
09/15/2022
UNIT 2102: OK UNIT 2104: OK UNIT 2106: PROVIDE SCREW PATTERN AT ALL GB BRACED LOCATIONS PER PLANS/ IRC R602.10.4, 7" OC EDGES (INCLUDING TOP AND BOTTOM PLATES) AND 7" OC FIELD THROUGHOUT UNIT 2108: PROVIDE SCREW PATTERN AT ALL GB BRACED LOCATIONS PER PLANS/ IRC R602.10.4, 7" OC EDGES (INCLUDING TOP AND BOTTOM PLATES) AND 7" OC FIELD - SEE KITCHEN WALL
All Rough Inspection - Residential Not Ready 9/19/2022 9/19/2022 09/19/2022
Misc
Corrective Action Required
09/16/2022
UNIT 2102: OK UNIT 2104: OK UNIT 2106: PROVIDE SCREW PATTERN AT ALL GB BRACED LOCATIONS PER PLANS/ IRC R602.10.4, 7" OC EDGES (INCLUDING TOP AND BOTTOM PLATES) AND 7" OC FIELD THROUGHOUT UNIT 2108: PROVIDE SCREW PATTERN AT ALL GB BRACED LOCATIONS PER PLANS/ IRC R602.10.4, 7" OC EDGES (INCLUDING TOP AND BOTTOM PLATES) AND 7" OC FIELD - SEE KITCHEN WALL
All Rough Inspection - Residential Passed 9/20/2022 9/20/2022 09/20/2022
Misc
Informational
09/20/2022
GB BRACING: UNIT 2102: OK UNIT 2104: OK UNIT 2106: OK UNIT 2108: OK
Sidewalk Inspection Partial 9/29/2022 9/29/2022 09/29/2022
Misc
Informational
09/06/2022
8-30-22 RH. Sidewalk was formed up and aggregate was placed and compacted. 9-6-22 RH. Sidewalk already has cracks on 3 panels. There was no expansion joints between any of the sidewalk and approaches. 9-29-22 RH. Sidewalk was removed and reformed. Aggregate was placed and compacted.
Driveway Inspection Partial 09/29/2022
Misc
Informational
09/29/2022
9-29-22 RH. Driveway was removed due to it leading to the curb of the storm inlet. Driveway was reformed and aggregate was placed and compacted.
Piers/Caissons Inspection - Residential Partial 10/4/2022 10/04/2022
Misc
Corrective Action Required
10/04/2022
UNIT 2108 OK
Piers/Caissons Inspection - Residential Partial 10/5/2022 (1:45) 10/5/2022 10/05/2022
Misc
Corrective Action Required
10/04/2022
UNIT 2108 OK UNIT 2106 OK
Sidewalk Inspection Passed 10/6/2022 10/6/2022 10/06/2022
Misc
Informational
09/29/2022
8-30-22 RH. Sidewalk was formed up and aggregate was placed and compacted. 9-6-22 RH. Sidewalk already has cracks on 3 panels. There was no expansion joints between any of the sidewalk and approaches. 9-29-22 RH. Sidewalk was removed and reformed. Aggregate was placed and compacted. 10-6-22 RH. Sidewalk meets LS and ADA specification.
Driveway Inspection Passed 10/6/2022 10/6/2022 10/06/2022
Misc
Informational
09/29/2022
9-29-22 RH. Driveway was removed due to it leading to the curb of the storm inlet. Driveway was reformed and aggregate was placed and compacted. 10-6-22 RH. Driveway meets LS and ADA specification.
Piers/Caissons Inspection - Residential Passed 10/7/2022 (9:45) 10/7/2022 10/07/2022
Misc
Corrective Action Required
10/05/2022
UNIT 2108 OK UNIT 2106 OK UNITS 2104,2102 OK
Water Service Inspection - R Passed 10/11/2022 (9:45) 10/11/2022 10/11/2022
Misc
Resolved
10/11/2022
2108, 2106, 2104, 2102 - PARTIAL INSPECTION ON CONNECTION TO MAIN, METER WELL, AND COPPER TAIL, OK TO COVER INSPECTED **RECALL FOR INSPECTION WHEN READY PEX TO HOUSE AND PEX TO COPPER TAIL CONNECTION**
Occupancy Inspection - Codes Residential Not Ready 11/28/2022 11/28/2022 11/28/2022
Misc
Corrective Action Required
11/28/2022
INSPECTION DENIED, UNITS NOT READY FOR OCCUPANCY INSPECTION
Occupancy Inspection - Codes Residential Failed 12/1/2022 12/1/2022 12/01/2022
Misc
Corrective Action Required
11/28/2022
-resolve all fees -final grade and sod -splash blocks -uncover all water meter lids -perm label disconnects/meter can with addresses UNIT 2108: -cover plate garage outlet -pan off garage cantilever -anti siphon device at spigot in mechanical room, shear off set screw head after tightening -interconnection required of all smoke detectors, see great room -max 7 3/4” rise at deck stairs UNIT 2106: -Downspout min 36” discharge from foundation -repair rock garage wall at spigot, low volt -install light fixture basement closet -install cover at service panel and label all breakers -install cover at j box kitchen island -light fixture 2nd floor hall -max 7 3/4” rise at deck stairs UNIT 2104: -pan off cantilever at garage -install cover at service panel and label all breakers -install cover at j box kitchen island -interconnection required all smokes UNIT 2102: -Downspout min 36” discharge from foundation -guardrail required at front porch -pan off cantilever at garage -breaker #9 at service panel showing error at AFCI test -attach light fixture to base at kitchen ceiling
Erosion Control Inspection Residential Passed 12/7/2022 12/7/2022 12/07/2022
Misc
Resolved
12/07/2022
RESTORE AND MAINTAIN EROSION CONTROL ON LOT
Plot Plan Inspection Failed 12/7/2022 12/7/2022 12/07/2022
Misc
Corrective Action Required
12/07/2022
UNCOVER MANHOLE MH 1-12 AT FRONT WEST SIDE OF LOT AS SHOWN ON PLOT PLAN, RAISE TO GRADE IF NECESSARY, LID SHOULD BE FLUSH WITH GRADE
Occupancy Inspection - Codes Residential Ready for Temp CO 12/7/2022 12/7/2022 12/07/2022
Misc
Corrective Action Required
12/01/2022
-UNCOVER MANHOLE MH 1-12 AT FRONT WEST SIDE OF LOT AS SHOWN ON PLOT PLAN, RAISE TO GRADE IF NECESSARY, LID SHOULD BE FLUSH WITH GRADE -splash blocks -uncover all water meter lids, water meter lids should be flush with grade -perm label disconnects/meter can with addresses UNIT 2108: -cover plate garage outlet -interconnection required of all smoke detectors, see great room NOT READY FOR OCCUPANCY UNIT 2106: -Downspout min 36” discharge from foundation -see front stoop INTERIOR COMPLETE, READY FOR TEMP OCCUPANCY, PAY FEE UNIT 2104: -Downspout min 36” discharge from foundation -see front stoop -interconnection required all smokes NOT READY FOR OCCUPANCY UNIT 2102: -Downspout min 36” discharge from foundation -see front stoop -breaker #9 at service panel showing error at AFCI test -attach light fixture to base at kitchen ceiling NOT READY FOR OCCUPANCY
Occupancy Inspection - Codes Residential Ready for Temp CO 12/12/2022 12/12/2022 12/12/2022
Misc
Corrective Action Required
12/07/2022
-UNCOVER MANHOLE MH 1-12 AT FRONT WEST SIDE OF LOT AS SHOWN ON PLOT PLAN, RAISE TO GRADE IF NECESSARY, LID SHOULD BE FLUSH WITH GRADE -splash blocks -uncover all water meter lids - see 2102 unit UNIT 2108: -INTERIOR COMPLETE, READY FOR TEMP OCCUPANCY, PAY FEE UNIT 2106: -Downspout min 36” discharge from foundation -see front stoop INTERIOR COMPLETE, READY FOR TEMP OCCUPANCY, PAY FEE UNIT 2104: -Downspout min 36” discharge from foundation -see front stoop -interconnection required all smokes -12/12/22 DOOR LOCKED, NO ACCESS UNIT 2102: -Downspout min 36” discharge from foundation -see front stoop -breaker #9 at service panel showing error at AFCI test -attach light fixture to base at kitchen ceiling -12/12/22 DOOR LOCKED, NO ACCESS
Occupancy Inspection - Codes Residential Failed 12/15/2022 12/15/2022 12/15/2022
Misc
Corrective Action Required
12/12/2022
-UNCOVER MANHOLE MH 1-12 AT FRONT WEST SIDE OF LOT AS SHOWN ON PLOT PLAN, RAISE TO GRADE IF NECESSARY, LID SHOULD BE FLUSH WITH GRADE -uncover all water meter lids - see 2102 unit, use shovel to clear around lid so it can be opened UNIT 2108: INTERIOR COMPLETE, READY FOR TEMP OCCUPANCY UNIT 2106: INTERIOR COMPLETE, READY FOR TEMP OCCUPANCY UNIT 2104: INTERIOR COMPLETE, READY FOR TEMP OCCUPANCY UNIT 2102 INTERIOR COMPLETE, READY FOR TEMP OCCUPANCY
Plot Plan Inspection Passed 12/20/2022 12/20/2022 12/20/2022
Misc
Resolved
12/20/2022
UNCOVER MANHOLE MH 1-12 AT FRONT WEST SIDE OF LOT AS SHOWN ON PLOT PLAN, RAISE TO GRADE IF NECESSARY, LID SHOULD BE FLUSH WITH GRADE
Occupancy Inspection - Codes Residential Full C of O 12/20/2022 12/20/2022 12/20/2022
Misc
Resolved
12/20/2022
Documents & Images
Date Uploaded File Type Document Name
09/28/2021 OS #1 - PERMIT APP
09/29/2021 Approved Plans APPROVED TRUSS LAYOUT
09/29/2021 Approved Plans APPROVED TRUSS PACKAGE
09/29/2021 Permit Codes Residential Plan Review
09/30/2021 Approved Plans APPROVED DRAWINGS
10/08/2021 Permit Codes Residential Plan Review
10/08/2021 Permit DS Building Permit
10/08/2021 Receipt Receipt for transaction:2021-007862
12/28/2021 M L Crose 2102, 2104, 2106, 2108 SW Holdbrooks Dr LSMO Osage Lot 1 Clayton P 2021-5066 3rd Party Footing Inspection Report 12-27-21
12/29/2021 Letter INSPECTION SUMMARY
01/28/2022 Approved Plans APPROVED DRAWINGS UPDATE
03/10/2022 Letter INSPECTION SUMMARY
03/15/2022 Letter INSPECTION SUMMARY
03/28/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
04/04/2022 Letter INSPECTION SUMMARY
08/17/2022 1 Osage Unit A,B,C Field Letter
08/23/2022 Letter INSPECTION SUMMARY
08/23/2022 Letter INSPECTION SUMMARY
08/23/2022 Letter INSPECTION SUMMARY
08/23/2022 Letter INSPECTION SUMMARY
08/26/2022 1 OSAGE LETTER
08/29/2022 Letter INSPECTION SUMMARY
08/29/2022 Letter INSPECTION SUMMARY
08/29/2022 Letter INSPECTION SUMMARY
08/29/2022 Letter INSPECTION SUMMARY
08/29/2022 Letter INSPECTION SUMMARY
08/30/2022 Letter INSPECTION SUMMARY
08/30/2022 Letter INSPECTION SUMMARY
09/01/2022 Letter INSPECTION SUMMARY
09/01/2022 Letter INSPECTION SUMMARY
09/01/2022 1 OSAGE LETTER #2
09/01/2022 1 OSAGE LETTER
09/01/2022 1 Osage Unit A,B,C Field Letter
09/01/2022 Engineer Report/Study APPROVED TRUSS LETTER
09/02/2022 Letter INSPECTION SUMMARY
09/02/2022 Letter INSPECTION SUMMARY
09/06/2022 Letter INSPECTION SUMMARY
09/06/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
09/13/2022 Letter INSPECTION SUMMARY
09/14/2022 Letter INSPECTION SUMMARY
09/15/2022 Plot Plan APPROVED PLOT PLAN
09/15/2022 Letter INSPECTION SUMMARY
09/16/2022 Letter INSPECTION SUMMARY
09/19/2022 Letter INSPECTION SUMMARY
09/20/2022 Letter INSPECTION SUMMARY
09/29/2022 Letter INSPECTION SUMMARY
09/29/2022 Letter INSPECTION SUMMARY
10/04/2022 Letter INSPECTION SUMMARY
10/05/2022 Receipt Receipt for transaction:2022-008050
10/05/2022 Letter INSPECTION SUMMARY
10/06/2022 Letter INSPECTION SUMMARY
10/06/2022 Letter INSPECTION SUMMARY
10/07/2022 Letter INSPECTION SUMMARY
10/11/2022 Letter INSPECTION SUMMARY
11/28/2022 Letter INSPECTION SUMMARY
12/01/2022 Letter INSPECTION SUMMARY
12/07/2022 Receipt Receipt for transaction:2022-009343
12/07/2022 Letter INSPECTION SUMMARY
12/07/2022 Letter INSPECTION SUMMARY
12/13/2022 Certificate/License Codes Temporary Certificate of Occupancy
12/13/2022 Certificate/License Codes Temporary Certificate of Occupancy
12/13/2022 Receipt Receipt for transaction:2022-009456
12/15/2022 Letter INSPECTION SUMMARY
12/20/2022 Letter INSPECTION SUMMARY
12/20/2022 Letter Field Certificate of Occupancy
12/20/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home