Permit Application Status

PRRES20211353


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20211353
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED/UNCOVERED PATIO -<PERMIT CLOSED WITH VIOLATIONS> Behomes defaulted and bank took back multiple properties.
03/25/2021
04/12/2021
10/05/2021
04/30/2024
Locations
Contacts
BE HOME LLC, Address:7618 S ARNETT RD, Phone:(816) 591-6013  
MIKE BRYANT HEATING & COOLING, Address:1711 E 123RD TER, Phone:(913) 441-7807  
TEAGUE ELECTRIC CONSTRUCTION INC, Address:12425 W 92ND ST, Phone:(913) 529-4600  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
MIKE@BEHOMELLC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/13/2021 04/09/2021
Kim Brennan
Legal description
Corrective Action Required
04/09/2021

The legal description, including plat or phase number and lot number, and street address must be provided on the plot plan. Missing the address number
Basement opening elevations
Corrective Action Required
04/09/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
Residential Plan Review Approved 04/13/2021 04/09/2021
Kim Brennan
Plot Plan Review Rejected 04/09/2021 04/08/2021
Kim Brennan
Legal description
Corrective Action Required
04/08/2021

The legal description, including plat or phase number and lot number, and street address must be provided on the plot plan. Missing the address number
Basement opening elevations
Corrective Action Required
04/08/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
Residential Plan Review Approved 04/09/2021 04/08/2021
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,424.87 $1,424.87 Paid 04/12/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 04/12/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 04/12/2021
8331507-Sewer Connection Fee $540.00 $540.00 Paid 04/12/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 04/12/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 04/12/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 6/3/2021 (8:00) 6/3/2021 06/03/2021
Water Service Inspection - R Failed 6/3/2021 (1:00) 6/3/2021 06/03/2021
Misc
Corrective Action Required
06/03/2021
PROVIDE GRAVEL AT BOTTOM OF WATER METER PIT
Water Service Inspection - R Passed 6/3/2021 06/03/2021
Misc
Resolved
06/03/2021
PROVIDE GRAVEL AT BOTTOM OF WATER METER PIT
Erosion Control Inspection Residential Failed 6/8/2021 06/08/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/08/2021
DEFICIENT EROSION CONTROL INSTALLATION. SHALL PROVIDE GRAVEL FILTER AT LOT ENTRANCE, RESTORE EROSION CONTROL ALONG THE STREET, AND CLEAN UP THE STREET ON BOTH SIDES NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Footing Inspection - Residential Passed 06/08/2021
Informational
06/08/2021
FOOTING APPROVED BY ENGINEER
Underslab Plumbing Inspection - Residential Failed 6/8/2021 6/8/2021 06/08/2021
Misc
Corrective Action Required
06/08/2021
INSPECTION DENIED DUE TO EROSION CONTROL DEFICIENCY. SHALL PROVIDE GRAVEL FILTER AT LOT ENTRANCE, RESTORE EROSION CONTROL ALONG THE STREET, AND CLEAN UP THE STREET ON BOTH SIDES
Suspended Slab Inspection Passed 11/15/2021 (3:00) 11/15/2021 11/15/2021
All Rough Inspection - Residential Failed 11/30/2021 11/30/2021 11/30/2021
Misc
Corrective Action Required
11/30/2021
-Nail corner studs per code at front bedroom -Toe nail all joists to wall top plates per code -Fb floor penetrations at traps -Complete electrical to exterior garage lights -Provide triple joists above garage per plan -Install anchor washers and nuts at garage PFH wall -Complete framing at fireplace and secure fireplace to framing -Complete electrical at fireplace -Solid block ends of lsl rafters above great room lvl beam -Pan off return air at 2nd fl bathroom tub -Brace ends of lvl roof beam from rotation -Provide a smoke/CO alarm immediately outside the bedrooms area -Nail siding at step flashings -Provide attic access to upper roof space -Have engineer check beam size underneath the master bedroom/fireplace wall -Anchor sill plate within 12” of basement slide door -Toe nail basement joists to sill plates per code -Joist notched more than 1/6 joist depth below front bath tub **DO NOT INSULATE
Electrical Service Inspection Passed 11/30/2021 11/30/2021
Gas Service Inspection - Residential Passed 11/30/2021 11/30/2021
All Rough Inspection - Residential Failed 12/20/2021 12/20/2021 12/20/2021
Misc
Corrective Action Required
11/30/2021
-Toe nail all joists to wall top plates per code at 1st fl front bedroom -Complete electrical to exterior garage lights -Nail siding at roof step flashings **2nd fl -Have engineer check beam size underneath the master bedroom/fireplace wall **also add at least another support stud under lvl beam -Anchor sill plate within 12” of basement slide door -Joist notched more than 1/6 joist depth below front bath tub **reinstall plumbing **OK TO INSULATE
All Rough Inspection - Residential Failed 12/28/2021 12/28/2021 12/28/2021
Misc
Corrective Action Required
12/20/2021
-Complete electrical to exterior garage lights -Have engineer check beam size underneath the master bedroom/fireplace wall **also add at least another support stud under lvl beam **OK TO INSULATE
All Rough Inspection - Residential Passed 1/4/2022 1/4/2022 01/04/2022
Misc
Resolved
01/04/2022
-Complete electrical to exterior garage lights -Have engineer check beam size underneath the master bedroom/fireplace wall **also add at least another support stud under lvl beam **OK TO INSULATE
Driveway Inspection Partial 4/11/2022 4/11/2022 04/11/2022
Misc
Informational
04/11/2022
4-11-22 AN. Forms are in place and aggregate is present and compacted.
Sidewalk Inspection Partial 4/11/2022 4/11/2022 04/11/2022
Misc
Informational
04/11/2022
4-11-22 AN forms are in place and aggregate is present and compacted. I had them adjust one of the forms to make it under 2%
Driveway Inspection Passed 4/18/2022 4/18/2022 04/19/2022
Misc
Informational
04/11/2022
4-11-22 AN. Forms are in place and aggregate is present and compacted.
Misc
Informational
04/19/2022
4-19-22 AN driveway looks good and has expansion joints at curb and right of way and meets Ada specs
Sidewalk Inspection Passed 4/18/2022 4/18/2022 04/19/2022
Misc
Informational
04/11/2022
4-11-22 AN forms are in place and aggregate is present and compacted. I had them adjust one of the forms to make it under 2%
Misc
Informational
04/19/2022
4-19-22 AN sidewalk looks good and meets Ada spec
Occupancy Inspection - Codes Residential Failed 5/2/2022 5/2/2022 05/02/2022
Misc
Corrective Action Required
05/02/2022
-Underslab plumbing and piers not inspected and approved by city -Provide address -Complete all exterior electrical -Complete deck: 2 bolts at deck beam-post connection, lag ledger bolts, install support devices at outer joist to ledge board -Final grade, sod, downspout and sump pump extension -Shall provide min 6” clearance from bottom of siding to grade -Seal exterior wall penetrations; seal above meter, AC disconnect, seal exterior lights, etc -Drive grounding rod down into soil -Provide sewer tracer wire port at grade -Install guardrail at 2nd fl loft and at stair -Garage door not self-closing -Garage stair handrail height shall be 34”-38” -Complete lighting above garage -Complete master bathroom -No power to master bathroom receptacle -Install secondary lock for deck slide door -Plumbing vent shall be min ten ft from bedroom window or 2 ft above window opening -Complete lighting above stair to basement -Install handrail for stair to basement -Provide AFCI protectiotn for all outlets required per NEC 210.12 (LV room, smoke, mud, etc) -Complete at water service: secure pex line per code, install water pressure reducer, etc -Install water heater -Install secondary lock for basement slide door
Occupancy Inspection - Codes Residential Failed 5/5/2022 5/5/2022 05/05/2022
Misc
Corrective Action Required
05/02/2022
-Underslab plumbing and piers not inspected and approved by city -Complete deck: 2 bolts at deck beam-post connection, lag ledger bolts, install support devices at outer joist to ledge board , complete stair to grade -Final grade, sod, downspout and sump pump extension -Shall provide min 6” clearance from bottom of siding to grade -Seal exterior wall penetrations; seal above meter, AC disconnect, seal exterior lights, etc -Provide sewer tracer wire port at grade -Plumbing vent shall be min ten ft from bedroom window or 2 ft above window opening -Install water heater ** Install electrical outlet for water heater
Underslab Plumbing Inspection - Residential Passed 05/06/2022
Misc
Resolved
05/06/2022
INSPECTION DENIED DUE TO EROSION CONTROL DEFICIENCY. SHALL PROVIDE GRAVEL FILTER AT LOT ENTRANCE, RESTORE EROSION CONTROL ALONG THE STREET, AND CLEAN UP THE STREET ON BOTH SIDES
Piers/Caissons Inspection - Residential Passed 05/06/2022
Informational
05/06/2022
PIERS APPROVED BY APEX ENGINEERING
Occupancy Inspection - Codes Residential Temporary C of O 5/6/2022 5/6/2022 05/06/2022
Misc
Corrective Action Required
05/05/2022
-Complete deck: 2 bolts at deck beam-post connection, lag ledger bolts, install support devices at outer joist to ledge board , complete stair to grade -Final grade, sod, downspout and sump pump extension -Shall provide min 6” clearance from bottom of siding to grade -Seal exterior wall penetrations; seal above meter, AC disconnect, seal exterior lights, etc -Provide sewer tracer wire port at grade **TCO APPROVED ON CONDITION THAT THE DECK IS NOT USED UNTIL IT IS COMPLETED
Miscellaneous Inspection Failed 6/3/2022 06/03/2022
Misc
Informational
06/03/2022
Homeowner is concerned that the water and silt is getting close to the back door of his walkout basement. Builder states to homeowner that the yard is final graded and nothing can be done.
Occupancy Inspection - Codes Residential Failed 6/23/2022 6/23/2022 06/23/2022
Misc
Corrective Action Required
05/06/2022
**Obtain lawn irrigation permit -Handrail for deck stair shall have max 3.5” width; provide two 1/2” through bolts or equivalent at each deck beam-post connection; deck ledger board shall be lag into floor rim per code; cedar post shall not be buried into soil; install support devices at outer joist to ledge board -Final grade not drain properly. Submit as-graded plot plan to city for review -Shall provide min 6” clearance from bottom of siding to grade -Seal exterior wall penetration at lawn irrigation water line -Provide sewer tracer wire port at grade
Occupancy Inspection - Codes Residential Failed 6/23/2022 06/23/2022
Misc
Corrective Action Required
06/23/2022
**Obtain lawn irrigation permit -Handrail for deck stair shall have max 3.5” width; provide two 1/2” through bolts or equivalent at each deck beam-post connection; deck ledger board shall be lag into floor rim per code; cedar post shall not be buried into soil; install support devices at outer joist to ledge board -Final grade not drain properly. Submit as-graded plot plan to city for review -Shall provide min 6” clearance from bottom of siding to grade -Seal exterior wall penetration at lawn irrigation water line -Provide sewer tracer wire port at grade
Erosion Control Inspection Residential Passed 02/21/2023
DCM2 ESC DEFICIENT INSTALLATION
Resolved
02/21/2023
DEFICIENT EROSION CONTROL INSTALLATION. SHALL PROVIDE GRAVEL FILTER AT LOT ENTRANCE, RESTORE EROSION CONTROL ALONG THE STREET, AND CLEAN UP THE STREET ON BOTH SIDES NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Miscellaneous Inspection Passed 02/21/2023
Misc
Resolved
02/21/2023
Homeowner is concerned that the water and silt is getting close to the back door of his walkout basement. Builder states to homeowner that the yard is final graded and nothing can be done.
Occupancy Inspection - Codes Residential Full C of O 04/30/2024
Misc
Informational
04/30/2024
**Obtain lawn irrigation permit -Handrail for deck stair shall have max 3.5” width; provide two 1/2” through bolts or equivalent at each deck beam-post connection; deck ledger board shall be lag into floor rim per code; cedar post shall not be buried into soil; install support devices at outer joist to ledge board -Final grade not drain properly. Submit as-graded plot plan to city for review -Shall provide min 6” clearance from bottom of siding to grade -Seal exterior wall penetration at lawn irrigation water line -Provide sewer tracer wire port at grade
Documents & Images
Date Uploaded File Type Document Name
03/25/2021 Application Form Permit Application
03/29/2021 license tax form
04/08/2021 Approved Plans Approved Drawings
04/08/2021 Letter Codes Residential Plan Review
04/09/2021 Plot Plan Approved Plot Plan
04/12/2021 Receipt Receipt for transaction:2021-001923
04/12/2021 Letter DS Building Permit
05/12/2021 M L Crose 4820 Jamestown Dr LSMO Monticello Lot 123 3rd Party Footing Inspection Report 5-11-21
06/03/2021 Letter INSPECTION SUMMARY
06/03/2021 Letter INSPECTION SUMMARY
06/03/2021 Letter INSPECTION SUMMARY
06/08/2021 Letter INSPECTION SUMMARY
06/08/2021 Letter INSPECTION SUMMARY
06/08/2021 Letter INSPECTION SUMMARY
11/15/2021 Letter INSPECTION SUMMARY
11/30/2021 Letter INSPECTION SUMMARY
11/30/2021 Letter INSPECTION SUMMARY
11/30/2021 Letter INSPECTION SUMMARY
12/20/2021 Letter INSPECTION SUMMARY
12/28/2021 Letter INSPECTION SUMMARY
01/04/2022 Letter INSPECTION SUMMARY
01/04/2022 4820 NE Jamestown Dr - Framing Inspection
04/11/2022 Letter INSPECTION SUMMARY
04/11/2022 Letter INSPECTION SUMMARY
04/19/2022 Letter INSPECTION SUMMARY
04/19/2022 Letter INSPECTION SUMMARY
05/02/2022 Letter INSPECTION SUMMARY
05/03/2022 Drain Tile
05/05/2022 Letter INSPECTION SUMMARY
05/05/2022 123 Monticello Letter
05/05/2022 Final_2021_10_18_DPiers_LSMO_K&E
05/06/2022 Letter INSPECTION SUMMARY
05/06/2022 Letter INSPECTION SUMMARY
05/06/2022 Letter Codes Temporary Certificate of Occupancy
06/03/2022 Letter INSPECTION SUMMARY
06/23/2022 Letter INSPECTION SUMMARY
06/23/2022 Letter INSPECTION SUMMARY
06/23/2022 Letter INSPECTION SUMMARY
09/16/2022 Letter Codes 10 Day Letter
02/21/2023 Letter INSPECTION SUMMARY
02/21/2023 Letter INSPECTION SUMMARY
04/30/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home