Permit Application Status

PRRES20210540


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20210540
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK - ROOF TRUSS - FINISHED BASEMENT STOP WORK ORDER generated on 04/16/2021 12:00 AM by username 'Patrick Schonfeldt'. STOP WORK ORDER removed on 04/19/2021 12:00 AM by username 'Patrick Schonfeldt'.
02/09/2021
02/12/2021
08/10/2021
02/15/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 02/17/2021 02/12/2021
Dylan Eppert
City infrustructure
Corrective Action Required
02/12/2021

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. MISSING STORM INLET IN REAR CORNER OF THE PROPERTY.
Residential Plan Review Approved 02/17/2021 02/12/2021
Dylan Eppert
Residential Plan Review Approved 02/11/2021 02/11/2021
Dylan Eppert
Plot Plan Review Rejected 02/11/2021 02/11/2021
Dylan Eppert
City infrustructure
Corrective Action Required
02/11/2021

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. MISSING STORM INLET IN REAR CORNER OF THE PROPERTY.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $871.64 $871.64 Paid 02/12/2021
8331507-Sewer Connection Fee $390.00 $390.00 Paid 02/12/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 02/12/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 02/12/2021
8331504-EFHB Middle Big Creek, Full $435.24 $435.24 Paid 02/12/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 02/12/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 02/12/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $100.00 $100.00 Paid 12/30/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Failed 4/16/2021 4/16/2021 04/16/2021
Misc
Corrective Action Required
04/16/2021
INSPECTION DENIED -FOOTING POURED WITHOUT INSPECTION, SUBMIT ENGINEER REPORT, REPORT REQUIRED TO BE UPLOADED TO PERMIT WITHIN 2 DAYS OF INSPECITON -NO ADDRESS POSTED
Footing Inspection - Residential Failed - Stop Work 4/16/2021 4/16/2021 04/16/2021
Misc
Corrective Action Required
04/16/2021
-FOOTING POURED WITHOUT INSPECTION, SUBMIT ENGINEER REPORT, REPORT REQUIRED TO BE UPLOADED TO PERMIT WITHIN 2 DAYS OF INSPECITON
Footing Inspection - Residential Passed 4/19/2021 04/19/2021
Misc
Resolved
04/19/2021
Underslab Plumbing Inspection - Residential Passed 4/30/2021 4/30/2021 04/30/2021
Misc
Resolved
04/30/2021
All Rough Inspection - Residential Partial 5/25/2021 5/25/2021 05/25/2021
Misc
Corrective Action Required
05/25/2021
**HAVE TRUSS PLANS ON SITE IF COVERED PORCH/DECK TRUSSES TO BE INSPECTED AT SAME TIME AS GARAGE PORTAL** 5/25/21 - GARAGE PORTAL OK.
Sewer Service Inspection - R Passed 7/21/2021 07/21/2021
Water Service Inspection - R Partial 7/21/2021 7/21/2021 07/21/2021
Misc
Informational
07/21/2021
-PARTIAL INSPECTION ON PEX TO HOUSE ENTRANCE
Water Service Inspection - R Passed 7/26/2021 (9:00) 7/26/2021 07/26/2021
Misc
Resolved
07/26/2021
All Rough Inspection - Residential Failed 7/26/2021 7/26/2021 07/26/2021
Misc
Corrective Action Required
05/25/2021
-Install front door and basement walkout -Fireblock between top plates at finished basement, seal any gaps or penetrations at fireblock material -Connect bath exhaust fan duct at basement -seal top plate penetrations bed#3 basement -(3) 2x10 joists at Rec room windows per plans -electrical receptacle required within 25’ or furnace at basement mech room -deck ledger attachment per code -(2) 1/2” through bolts at each post/beam connection per code -bolt outer ply of beam to ledger and add angle clip on inner ply (DECK INCOMPLETE AT ALL ROUGH)
All Rough Inspection - Residential Failed 8/6/2021 8/6/2021 08/06/2021
Misc
Corrective Action Required
07/26/2021
-(3) 2x10 joists at Rec room windows per plans - complete gas line that was removed for joist correction
All Rough Inspection - Residential Passed 8/18/2021 8/18/2021 08/18/2021
Misc
Resolved
08/18/2021
Gas Service Inspection - Residential Passed 08/18/2021
Electrical Service Inspection Failed 10/8/2021 10/8/2021 10/08/2021
Misc
Corrective Action Required
10/08/2021
intersystem bonding required
Electrical Service Inspection Passed 10/29/2021 10/29/2021 10/29/2021
Misc
Resolved
10/29/2021
Driveway Inspection Partial 11/15/2021 11/15/2021 11/15/2021
Misc
Informational
11/15/2021
11/15/21 Driveway forms and materials passed per inspection. JJ
Sidewalk Inspection Partial 11/15/2021 11/15/2021 11/15/2021
Misc
Informational
11/15/2021
11/15/21 Monday Sidewalk passed pre-inspection forms and materials. JJ
Driveway Inspection Passed 11/17/2021 11/17/2021 11/17/2021
Misc
Informational
11/15/2021
11/15/21 Driveway forms and materials passed per inspection. JJ
Misc
Informational
11/17/2021
Driveway passed final inspection. JJ
Sidewalk Inspection Passed 11/17/2021 11/17/2021 11/17/2021
Misc
Informational
11/15/2021
11/15/21 Monday Sidewalk passed pre-inspection forms and materials. JJ
Misc
Informational
11/17/2021
Sidewalk passed final inspection. JJ
Erosion Control Inspection Residential Failed 12/13/2021 12/13/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
12/13/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Failed 12/13/2021 12/13/2021 12/13/2021
Misc
Corrective Action Required
12/13/2021
-final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -check water meter and siding from grade spacing at time of final grade and sod -adjust premise identification to not be behind lighting fixture -adjust garage entry door to be self closing -spark ring on outlets where not code compliant see fridge, above fireplace, -sheared off set screw required at anti-siphon device in basement -deck stairwell guard rail to be compliant with code section R312.1.3 Opening limitations. -obtain lawn irrigation permit
Occupancy Inspection - Codes Residential Failed 12/30/2021 12/30/2021 12/30/2021
Misc
Corrective Action Required
12/13/2021
-splash blocks and sump pump discharge to extend 36” from foundation -grade less than 6" from siding, several locations throughout -spark ring on outlets where not code compliant see fridge, above fireplace -obtain lawn irrigation permit -resolve outstanding inspection fee(s) before final c of o
Erosion Control Inspection Residential Passed 12/30/2021 12/30/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
12/13/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Temporary C of O 1/6/2022 1/6/2022 01/06/2022
Misc
Corrective Action Required
12/30/2021
-splash blocks and sump pump discharge to extend 36” from foundation -grade less than 6" from siding, several locations throughout (make sure to maintain 6" of fall within first 10' of foundation as required by code, do not have correction create an issue where there is negative slope back towards the foundation from altering grade to meet 6" requirement) **OK FOR TCO, TCO EXPIRES 2/11/22**
Plot Plan Inspection Passed 1/26/2022 1/26/2022 01/26/2022
Occupancy Inspection - Codes Residential Failed 1/26/2022 1/26/2022 01/26/2022
Misc
Corrective Action Required
01/06/2022
-splash blocks and sump pump discharge to extend 36” from foundation -Replace vegetation removed for regrading at rear of lot **OK FOR TCO, TCO EXPIRES 2/11/22**
Occupancy Inspection - Codes Residential Full C of O 2/15/2022 2/15/2022 02/15/2022
Misc
Resolved
02/15/2022
Documents & Images
Date Uploaded File Type Document Name
02/09/2021 Application Form MN #100 - PERMIT APPLICATION
02/09/2021 100 MANOR AT STONEY CREEK ROOF LAYOUT
02/09/2021 LOT 100 FINAL
02/09/2021 MN #100 - Charlotte - Tuscan - Sheets- signed
02/09/2021 2623880 RF SEAL 02052021
02/11/2021 Specifications APPROVED TRUSS PACKAGE
02/11/2021 Drawing APPROVED TRUSS LAYOUT
02/11/2021 Approved Plans APPROVED HOUSE PLANS
02/11/2021 Letter Codes Residential Plan Review
02/12/2021 Plot Plan APPROVED PLOT PLAN
02/12/2021 Receipt Receipt for transaction:2021-000695
02/12/2021 Letter DS Building Permit
04/16/2021 Letter INSPECTION SUMMARY
04/16/2021 Letter Stop Work Order
04/16/2021 Lot 100 Stoney Creek Manor Footing Inspection
04/16/2021 Lot 100 Stoney Creek Foundation Inspection
04/19/2021 Letter INSPECTION SUMMARY
04/30/2021 Letter INSPECTION SUMMARY
05/25/2021 Letter INSPECTION SUMMARY
07/21/2021 Letter INSPECTION SUMMARY
07/21/2021 Letter INSPECTION SUMMARY
07/26/2021 Letter INSPECTION SUMMARY
07/26/2021 Letter INSPECTION SUMMARY
08/06/2021 Letter INSPECTION SUMMARY
08/18/2021 Letter INSPECTION SUMMARY
08/18/2021 Letter INSPECTION SUMMARY
10/08/2021 Letter INSPECTION SUMMARY
10/29/2021 Letter INSPECTION SUMMARY
11/15/2021 Letter INSPECTION SUMMARY
11/15/2021 Letter INSPECTION SUMMARY
11/17/2021 Letter INSPECTION SUMMARY
11/17/2021 Letter INSPECTION SUMMARY
12/13/2021 Letter INSPECTION SUMMARY
12/13/2021 Letter INSPECTION SUMMARY
12/30/2021 Letter INSPECTION SUMMARY
12/30/2021 Letter INSPECTION SUMMARY
12/30/2021 Receipt Receipt for transaction:2021-009585
01/06/2022 Letter Codes Temporary Certificate of Occupancy
01/26/2022 Letter INSPECTION SUMMARY
01/26/2022 Letter INSPECTION SUMMARY
02/15/2022 Letter Field Certificate of Occupancy
02/15/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home