Permit Application Status

PRRES20200759


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20200759
Building Permit - Residential
Certificate of Occupancy
HUNT MIDWEST RESIDENTIAL LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
03/24/2020
04/08/2020
05/18/2021
Locations
Contacts
HUNT MIDWEST RESIDENTIAL LLC, Address:8300 NE UNDERGROUND DR  
IQ CONSTRUCTION, Address:P O BOX 6423, Phone:(816) 582-8100  
JENNIFER@IQHOMEBUILDERS.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
SAFEHOUSE ELECTRIC COMPANY, Address:P O BOX 1833, Phone:(816) 935-8113  
FIVE STAR PLUMBING INC, Address:P O BOX 452, Phone:(816) 228-8821  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 03/26/2020 04/03/2020
Dylan Eppert
Plot Plan Review Approved 03/26/2020 04/02/2020
Dylan Eppert
Miscellaneous Correction
Corrective Action Required
03/26/2020

Construction drawings show an optional covered deck please clarify with builder if it will be covered or not for the plot plan.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,027.93 $1,027.93 Paid 04/08/2020
8331507-Sewer Connection Fee $450.00 $450.00 Paid 04/08/2020
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 04/08/2020
8350015-Water Meter Fee $425.02 $425.02 Paid 04/08/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 04/08/2020
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 04/08/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 11/18/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/12/2020 (11:00) 5/12/2020 05/12/2020
Underslab Plumbing Inspection - Residential Not Ready 5/20/2020 5/20/2020 05/20/2020
Misc
Corrective Action Required
05/20/2020
- INTERIOR DRAIN TILE CONNECTED TO SUMP BASIN REQUIRED - - EXTERIOR DRAIN TILE- - BACKFILL AROUND FOUNDATION FOR ACCESS - NOT READY FEE
Underslab Plumbing Inspection - Residential Passed 5/21/2020 5/21/2020 05/21/2020
Misc
Resolved
05/21/2020
- INTERIOR DRAIN TILE CONNECTED TO SUMP BASIN REQUIRED - - EXTERIOR DRAIN TILE- - BACKFILL AROUND FOUNDATION FOR ACCESS - NOT READY FEE
Piers/Caissons Inspection - Residential Passed 6/10/2020 (9:15) 6/10/2020 06/10/2020
Misc
Informational
06/10/2020
(2) 24 X 44 DECK PIERS
All Rough Inspection - Residential Partial 8/10/2020 8/10/2020 08/10/2020
Misc
Informational
08/10/2020
- PORTAL FRAMING ONLY - - STHD14 NAILED OFF, HEADER NAILING PATTERN APPROVED - - PROVIDE TENSION STRAP HEADER TO JACK STUD PER PLAN CHECK AT ALL TRADE INSPECTION -
Erosion Control Inspection Residential Failed 8/31/2020 8/31/2020 08/31/2020
Misc
Corrective Action Required
08/31/2020
Inadequate erosion control, must be corrected within two business days
Electrical Service Inspection Passed 8/31/2020 8/31/2020 08/31/2020
Gas Piping Inspection - Residential Failed 8/31/2020 8/31/2020 08/31/2020
Misc
Corrective Action Required
08/31/2020
Secure gas piping at fireplace
Gas Service Inspection - Residential Passed 8/31/2020 8/31/2020 08/31/2020
All Rough Inspection - Residential Failed 8/31/2020 8/31/2020 08/31/2020
Misc
Informational
08/10/2020
- PORTAL FRAMING ONLY - - STHD14 NAILED OFF, HEADER NAILING PATTERN APPROVED - - PROVIDE TENSION STRAP HEADER TO JACK STUD PER PLAN CHECK AT ALL TRADE INSPECTION -
Misc
Corrective Action Required
08/31/2020
GENERAL- -concrete encased electrode grounding connection to remain accessible -install basement window FRAMING- -Furr duct in garage for insulation. -Stud to stud and abutting studs at intersecting wall corners (at braced wall panels) 12” oc per code -complete framing and secure fireplace -block joists above load bearing walls, beams and cantilevers with joist material per plan -2x10 ridge required at covered front porch per plan ELECTRICAL- -protect NM conductor minimum 6 inches AFF at floor penetrations GAS -secure gas line at fireplace OK TO INSULATE DO NOT ROCK RE-INSPECTION REQUIRED
All Rough Inspection - Residential Failed 9/2/2020 9/2/2020 09/02/2020
Misc
Informational
08/31/2020
- PORTAL FRAMING ONLY - - STHD14 NAILED OFF, HEADER NAILING PATTERN APPROVED -
Misc
Corrective Action Required
08/31/2020
GENERAL- -concrete encased electrode grounding connection to remain accessible - -install basement window - - SEAL GAS LINE AT FLOOR PENETRATION AT FIREPLACE - FRAMING- -2x10 ridge required at covered front porch per plan OK TO INSULATE DO NOT ROCK RE-INSPECTION REQUIRED
All Rough Inspection - Residential Failed 9/10/2020 9/10/2020 09/10/2020
Misc
Informational
09/02/2020
- PORTAL FRAMING ONLY - - STHD14 NAILED OFF, HEADER NAILING PATTERN APPROVED -
Misc
Corrective Action Required
09/02/2020
GENERAL- -concrete encased electrode grounding connection to remain accessible ( provide access panel COF) -
Sewer Service Inspection - R Passed 9/29/2020 (9:30) 9/29/2020 09/29/2020
Water Service Inspection - R Passed 9/30/2020 (11:30) 9/30/2020 09/30/2020
Driveway Inspection Partial 11/10/2020 (P.M.) 11/10/2020 11/11/2020
Misc
Informational
11/11/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 11/10/2020 (P.M.) 11/10/2020 11/11/2020
Misc
Informational
11/11/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 11/18/2020 11/18/2020 11/17/2020
Misc
Informational
11/11/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Misc
Informational
11/17/2020
PRE POUR INSPECTION The south sidewalk forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 11/18/2020 11/18/2020 11/18/2020
Misc
Corrective Action Required
11/18/2020
-All outstanding fees must be paid in full -Provide engineered documentation of retaining wall -Only partial approval of driveway and sidewalk inspection, contact development services to resolve this issue -Provide gutters and downspouts -Downspouts and sump piping to discharge minimum 36” from foundation -Remove trash and construction debris -Final grade and sod per approved plot plan -Seal tops and sides of AC disconnect and exterior lighting exposed to the elements -deck post to beam connections per code, through bolts -Secure raceway within 12 inches of AC disconnect enclosure -Small separation door from garage into pantry required to self close and self latch, also secure weather stripping -handrail at garage stairs to extend over lowest riser and terminate into post -seal garage foundation and steps from interior of structure -repair sheet rock in garage ceiling -secure junction box under kitchen sink -complete dishwasher electrical installation -complete fireplace installation -Sliding glass door secondary locking device -Provide AFCI protection of laundry circuit -Remove paper from batt insulation in unfinished basement area
Occupancy Inspection - Codes Residential Failed 11/19/2020 11/19/2020 11/19/2020
Misc
Corrective Action Required
11/18/2020
-Provide engineered documentation of retaining wall -Only partial approval of driveway and sidewalk inspection, contact development services to resolve this issue -Provide gutters and downspouts -Downspouts and sump piping to discharge minimum 36” from foundation -Remove trash and construction debris -Final grade and sod per approved plot plan -seal garage foundation and steps from interior of structure -repair sheet rock in garage ceiling
Occupancy Inspection - Codes Residential Temporary C of O 11/19/2020 11/19/2020
Misc
Corrective Action Required
11/19/2020
-Only partial approval of driveway and sidewalk inspection, contact development services to resolve this issue -Provide gutters and downspouts -Downspouts to discharge minimum 36” from foundation TCO VALID THROUGH 12/19/2020
Plot Plan Inspection Passed 11/19/2020
Deck Final Inspection - Residential Passed 11/19/2020
Driveway Inspection Passed 11/18/2020 11/18/2020 11/23/2020
Misc
Informational
11/11/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 11/24/2020 11/24/2020 11/30/2020
Misc
Informational
11/17/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Misc
Informational
11/17/2020
PRE POUR INSPECTION The south sidewalk forms are set and there appears to be sufficient compacted aggregate.
Erosion Control Inspection Residential Passed 05/18/2021
Misc
Resolved
05/18/2021
Inadequate erosion control, must be corrected within two business days
Gas Piping Inspection - Residential Passed 05/18/2021
Misc
Resolved
05/18/2021
Secure gas piping at fireplace
All Rough Inspection - Residential Passed 05/18/2021
Misc
Resolved
05/18/2021
- PORTAL FRAMING ONLY - - STHD14 NAILED OFF, HEADER NAILING PATTERN APPROVED -
Misc
Resolved
05/18/2021
GENERAL- -concrete encased electrode grounding connection to remain accessible ( provide access panel COF) - FRAMING- -2x10 ridge required at covered front porch per plan
Occupancy Inspection - Codes Residential Full C of O 05/18/2021
Misc
Resolved
05/18/2021
-Only partial approval of driveway and sidewalk inspection, contact development services to resolve this issue -Provide gutters and downspouts -Downspouts to discharge minimum 36” from foundation TCO VALID THROUGH 12/19/2020
Documents & Images
Date Uploaded File Type Document Name
03/24/2020 Scope of Work Permit Application
03/24/2020 2417 SW River Trail Rd - Signed Plot Plan
03/24/2020 2417 SW River Trail Rd - OAKMONT - GL - Sealed Plans
03/26/2020 Letter Codes Residential Plan Review
03/26/2020 2417 SW River Trail Rd - LSMO Excise Tax
03/31/2020 2417 SW River Trail Rd -REVISED OAKMONT - GL - Sealed Plans
04/02/2020 Plot Plan APPROVED PLOT PLAN
04/02/2020 Letter Codes Residential Plan Review
04/03/2020 Plans Approved Construction Plans
04/08/2020 Receipt Receipt for transaction:2020-001438
04/08/2020 Letter DS Building Permit
05/12/2020 Letter INSPECTION SUMMARY
05/20/2020 Letter INSPECTION SUMMARY
05/21/2020 Letter INSPECTION SUMMARY
06/10/2020 Letter INSPECTION SUMMARY
07/29/2020 basement plan approved 2245_001
08/10/2020 Letter INSPECTION SUMMARY
08/28/2020 Plans APPROVED REVISED PLANS
08/31/2020 Letter INSPECTION SUMMARY
08/31/2020 Letter INSPECTION SUMMARY
08/31/2020 Letter INSPECTION SUMMARY
08/31/2020 Letter INSPECTION SUMMARY
08/31/2020 Letter INSPECTION SUMMARY
09/02/2020 Letter INSPECTION SUMMARY
09/10/2020 Letter INSPECTION SUMMARY
09/14/2020 Engineer Report/Study 2417 SW River Trail Rd_Framing Evaluation Report_9-11-20
09/29/2020 Letter INSPECTION SUMMARY
11/11/2020 Letter INSPECTION SUMMARY
11/11/2020 Letter INSPECTION SUMMARY
11/11/2020 Letter INSPECTION SUMMARY
11/17/2020 Letter INSPECTION SUMMARY
11/18/2020 Letter INSPECTION SUMMARY
11/18/2020 Receipt Receipt for transaction:2020-007625
11/19/2020 Letter INSPECTION SUMMARY
11/19/2020 2417 sw River Trail Retaining wall Report
11/19/2020 Letter Codes Temporary Certificate of Occupancy
11/19/2020 Letter INSPECTION SUMMARY
11/19/2020 Letter INSPECTION SUMMARY
11/23/2020 Letter INSPECTION SUMMARY
11/30/2020 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter Codes Final Certificate of Occupancy
05/18/2021 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: