Permit Application Status

PRRES20193664


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20193664
Building Permit - Residential
Certificate of Occupancy
SORENSEN BRETT & TESS
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK - PARTIAL FINISHED BASEMENT - SUSPENDED SLAB
12/23/2019
01/10/2020
02/27/2024
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
ASHLEY@NEWMARKHOMESKC.COM  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
CLASS ONE ELECTRIC INC, Address:PO BOX 24343, Phone:(913) 915-1767  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
SORENSEN BRETT & TESS, Address:1713 SW 27TH ST  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 12/27/2019 01/08/2020
Dylan Eppert
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
12/26/2019

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) FINISHED AND UNFINISHED BASEMENT SQ FOOTAGES MUST BE ON THE CONSTRUCTION DRAWINGS.
07 Identify emergency escape openings from bedrooms
Corrective Action Required
12/26/2019

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) BEDROOM #2 EGRESS NOT LABELED
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
12/26/2019

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) THERE IS NOT A COMBO DETECTOR INBETWEEN BETWEEN #3 AND BEDDROOM #4. ALSO "SD" IN THIS CONTEXT WOULD MEAN SMOKE DETECTOR, MEANING CARBON DETECTORS WOULD BE MISSING OR NOT LABELED IN THIS REVIEW.
10 Combustion air
Corrective Action Required
12/26/2019

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407) COMBUSTION AIR CALCULATIONS MUST BE PROVIDED OR A NOTE SHOWING THIS APPLICATION IS DIRECTLY VENTED TO THE OUTSIDE.
Miscellaneous Correction
Corrective Action Required
12/26/2019

ELECTRICAL CONTRACOR MUST OBTAIN BUSINESS LICENSE PRIOR TO PERMIT ISSUANCE.
Plot Plan Review Approved 12/27/2019 01/02/2020
Dylan Eppert
North arrow and scale
Corrective Action Required
12/26/2019

The plot plan must be submitted on either (1) 81/2” x 11”, (2) 81/2”x 14”, or (3) 11” x 17” paper. All information on the plot plan must be drawn to scale. Scale must be 1” = 10’, 20’, or 30’; smaller scales that are multiples of the preceding scales may be used if necessary to represent large sites. All information on the plot plan must be clearly legible.)
Spot elevations
Corrective Action Required
12/26/2019

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. ONCE I RECEIVE PLOT PLAN THAT IS TO SCALE I CAN CALCULATE SLOPES.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,038.52 $1,038.52 Paid 01/10/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 01/10/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 01/10/2020
8331507-Sewer Connection Fee $420.00 $420.00 Paid 01/10/2020
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 01/10/2020
8350015-Water Meter Fee $425.02 $425.02 Paid 01/10/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/11/2020 (11:00) 2/11/2020 02/11/2020
Misc
Resolved
04/01/2020
Piers already poured 2/11/20 11:28 Footing ok to pour 3rd party VAN DEURZEN BY CHAD STREETER
Piers/Caissons Inspection - Residential Failed 2/14/2020 02/14/2020
Underslab Plumbing Inspection - Residential Passed 4/1/2020 4/1/2020 04/01/2020
Piers/Caissons Inspection - Residential Passed 4/1/2020 4/1/2020 04/01/2020
Informational
04/01/2020
3RD PARTY DECK PIERS VAN DEURZEN & ASSOCIATES BY CHAD STREETER
Sewer Service Inspection - R Passed 5/5/2020 (1:00) 5/5/2020 05/05/2020
Water Service Inspection - R Passed 5/8/2020 5/8/2020 at 1:03 PM 05/08/2020
Erosion Control Inspection Residential Failed 6/12/2020 6/12/2020 06/12/2020
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/12/2020
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Passed 6/17/2020 6/17/2020 06/17/2020
DCM3 ESC REQUIRED 2 DAY
Resolved
06/17/2020
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Electrical Service Inspection Passed 7/1/2020 7/1/2020 07/01/2020
Gas Piping Inspection - Residential Passed 7/1/2020 7/1/2020 07/01/2020
Gas Service Inspection - Residential Passed 07/01/2020
All Rough Inspection - Residential Failed 7/1/2020 7/1/2020 07/01/2020
Miscellaneous Correction
Corrective Action Required
07/01/2020
***DO NOT INSULATE*** -ADD BOLTS TO JOIST/POST CONNECTIONS AT DECK -POSTS NOT TO BE NOTCHED FOR SIDE MEMBERS PER S3.0 AT DECK -ANCHOR BOLTS TO BE IN MIDDLE 3RD OF PLATE-GARAGE -TIGHTEN ANCHOR BOLTS IN GARAGE -FIRE BLOCK FUR OUT IN GARAGE -FIRE BLOCK WEBS OF I BEAMS IN ALL WALLS -NAIL JOIST LAP CONNECTIONS OVER LAUNDRY -NAIL ALL CORNER CONNECTIONS AND INTERMEDIATE WALL CONNECTIONS PER CODE -NAIL BOTTOM PLATE PER CODE-MASTER CLOSET, MASTER BED DOORWAYS, MASTER BED EXTERIOR WALLS -ADD MISSING JOIST HANGERS IN KITCHEN -SET NAILS IN JOIST HANGERS IN KITCHEN -PROVIDE ADDITIONAL STUDS TO CARRY POINT LOAD IN OFFICE -MISSING (3) 2X4 IN MASTER BATH WALL -SEAL FIREPLACE CHASE -PROVIDE CLIPS AND THRUST BLOCKS ON STAIRS PER PLANS -TIGHTEN ANCHOR BOLTS IN BASEMENT -FIRE BLOCK FURDOWNS AND WEB BEAMS IN BASEMENT ALL LOCATIONS -SEAL UPWARDS PENETRATIONS IN MECHANICAL ROOM -FIRE BLOCK BEDROOM CHASE WLL BY WINDOW -PROVIDE HORIZONTAL FIREBLOCKING MAX 10’ IN FUROUT WALL -EXPOSE FRAMING IN COVERED DECK FOR INSPECTION -MISSING (2) 2X12 ON COVERED DECK -MISSING (3) 2X6 IN PANTRY WALL -WRONG SIZED STEEL COLUMN IN BEDROOM 3 WALL (TYPE E, 3 1/2” PER PLANS) -PROVIDE MINIMUM (5) 2X4 SUPPORTING BEAM IN BEDROOM 3 PER PLANS -PROVIDE SOLID BLOCKING OF JOISTS PARALLEL TO FOUNDATION WALL PER DETAIL ON S2.0 -INSULATE AND PROVIDE BLOCKING ABOVE WALL AT CANTILEVERS
All Rough Inspection - Residential Failed 7/9/2020 7/9/2020 07/09/2020
Miscellaneous Correction
Corrective Action Required
07/01/2020
***DO NOT INSULATE*** -ADD BOLTS TO JOIST/POST CONNECTIONS AT DECK -POSTS NOT TO BE NOTCHED FOR SIDE MEMBERS PER S3.0 AT DECK -FIRE BLOCK WEBS OF I BEAMS IN ALL WALLS -NAIL ALL CORNER CONNECTIONS AND INTERMEDIATE WALL CONNECTIONS PER CODE -PROVIDE ADDITIONAL STUDS TO CARRY POINT LOAD IN OFFICE -MISSING (3) 2X4 IN MASTER BATH WALL -SEAL FIREPLACE CHASE -THRUST BLOCKS ON STAIRS PER PLANS -TIGHTEN ANCHOR BOLTS IN BASEMENT -FIRE BLOCK FURDOWNS AND WEB BEAMS IN BASEMENT ALL LOCATIONS -FIREBLOCK DEAD SPACE IN BASEMENT BEDROOM -SEAL UPWARDS PENETRATIONS IN MECHANICAL ROOM -FIRE BLOCK BEDROOM CHASE WLL BY WINDOW -PROVIDE HORIZONTAL FIREBLOCKING MAX 10’ IN FUROUT WALL -EXPOSE FRAMING IN COVERED DECK FOR INSPECTION -PROVIDE SOLID BLOCKING OF JOISTS PARALLEL TO FOUNDATION WALL PER DETAIL ON 2 S2.0 -INSULATE AND PROVIDE BLOCKING ABOVE WALL AT CANTILEVERS
All Rough Inspection - Residential Passed 7/16/2020 7/16/2020 07/16/2020
Miscellaneous Correction
Corrective Action Required
07/09/2020
Driveway Inspection Passed 8/12/2020 8/12/2020 08/13/2020
Misc
Informational
08/13/2020
On Wednesday, 8-12-2020 a field inspection was performed for the drive approach and forming and sub-grade met city standards. Drive passes inspection.
Erosion Control Inspection Residential Passed 09/29/2020
Misc
Resolved
09/29/2020
-deficient erosion control installation, shall be in compliance within two days. No further inspections until complete -Street cleanup required immediately. No further inspections until complete -remove trash from site -Remove overgrown weeds and vegetation
Occupancy Inspection - Codes Residential Failed 11/23/2020 11/23/2020 11/23/2020
Misc
Corrective Action Required
11/23/2020
-No sidewalk inspection on record, contact development services to resolve this issue -Remove trash and construction debris -Provide gutters and downspouts -Downspouts and sump piping to discharge minimum 36 inches from foundation -Final grade and sod per approved plot -Remove dryer vent termination screen -complete cooktop installation
Occupancy Inspection - Codes Residential Temporary C of O 11/30/2020 11/30/2020 11/30/2020
Misc
Corrective Action Required
11/23/2020
-No sidewalk inspection on record, contact development services to resolve this issue -Remove trash and construction debris -Complete downspout installation -Downspouts and sump piping to discharge minimum 36 inches from foundation -Final grade and sod per approved plot TCO VALID THROUGH 12/30/2020
Sidewalk Inspection Passed 12/2/2020 12/2/2020 12/02/2020
Misc
Informational
12/02/2020
On Wednesday, 12-02-2020. I performed a visual inspection on sidewalk that already had been poured. Finish looked exceptable so I’m passing walk.
Occupancy Inspection - Codes Residential Failed 12/11/2020 12/11/2020
Misc
Corrective Action Required
11/30/2020
-No sidewalk inspection on record, contact development services to resolve this issue -Remove trash and construction debris -Complete downspout installation -Downspouts and sump piping to discharge minimum 36 inches from foundation -Final grade and sod per approved plot TCO VALID THROUGH 12/30/2020
Misc
Corrective Action Required
12/11/2020
- Deck built without approval. -deck beams are over span. triple 2x10 and 2-2x10 both at 11'6" span. see code section 507 for deck beam span. - no graspable handrail on the stairs. - 4x4 post burred in the ground. -wall built on deck with electrical hanging under deck not terminated. -stairs are supported by single joist. Deck is over 20' built line. please contact Dan Harper to discuss the set back violation. Deck is approximately 18'6" to rear 20' build line. Do not issue COFO until set back issues are resolved.
Plot Plan Inspection Failed 03/18/2021
Misc
Corrective Action Required
03/18/2021
water meter lid required to be at grade level and meter 14-18" below grade
Occupancy Inspection - Codes Residential Failed 3/19/2021 3/19/2021 03/18/2021
Misc
Corrective Action Required
12/11/2020
-Downspouts to discharge minimum 36 inches from foundation TCO HAS EXPIRED
Misc
Corrective Action Required
12/11/2020
- Deck built without approval. -deck beams are over span. triple 2x10 and 2-2x10 both at 11'6" span. see code section 507 for deck beam span. - no graspable handrail on the stairs. - 4x4 post burred in the ground. -wall built on deck with electrical hanging under deck not terminated. -stairs are supported by single joist. Deck is over 20' built line. please contact Dan Harper to discuss the set back violation. Deck is approximately 18'6" to rear 20' build line. Do not issue COFO until set back issues are resolved.
Suspended Slab Inspection Passed 05/18/2021
Erosion Control Inspection Residential Passed 05/18/2021
Misc
Resolved
05/18/2021
-deficient erosion control installation, shall be in compliance within two days. No further inspections until complete -Street cleanup required immediately. No further inspections until complete -remove trash from site -Remove overgrown weeds and vegetation
Occupancy Inspection - Codes Residential Failed 05/18/2021
Misc
Corrective Action Required
03/18/2021
-Downspouts to discharge minimum 36 inches from foundation -SECOND NOTICE- The temporary certificate of occupancy has expired at this address. If remaining correction items are complete please schedule an occupancy inspection. If remaining correction items are not complete a permit extension request must be submitted in writing with the expected date of completion.
Misc
Corrective Action Required
03/18/2021
- Deck built without approval. -deck beams are over span. triple 2x10 and 2-2x10 both at 11'6" span. see code section 507 for deck beam span. - no graspable handrail on the stairs. - 4x4 post burred in the ground. -wall built on deck with electrical hanging under deck not terminated. -stairs are supported by single joist. Deck is over 20' built line. please contact Dan Harper to discuss the set back violation. Deck is approximately 18'6" to rear 20' build line. Do not issue COFO until set back issues are resolved.
Documents & Images
Date Uploaded File Type Document Name
12/26/2019 Letter Codes Residential Plan Review
01/03/2020 Letter Codes Residential Plan Review
01/10/2020 Receipt Receipt for transaction: 2020-000131
01/10/2020 Letter DS Building Permit
01/10/2020 Plans DOC011020-001
02/11/2020 Letter INSPECTION SUMMARY
04/01/2020 Letter INSPECTION SUMMARY
04/01/2020 Engineer Report/Study 1713 SW 27th St_PIER INSP_2020-02-06
04/01/2020 Engineer Report/Study 1713 SW 27TH ST_PIER PLAN_1-30-20
04/01/2020 Letter INSPECTION SUMMARY
04/08/2020 1713 SW 27th St_ALL SLAB INSP_2020-04-02
04/10/2020 1713 SW 27th St_ALL SLAB INSP_2020-04-02
05/05/2020 Letter INSPECTION SUMMARY
05/08/2020 Letter INSPECTION SUMMARY
06/12/2020 Letter INSPECTION SUMMARY
06/17/2020 Letter INSPECTION SUMMARY
06/17/2020 Letter INSPECTION SUMMARY
07/01/2020 Letter INSPECTION SUMMARY
07/01/2020 Letter INSPECTION SUMMARY
07/01/2020 Letter INSPECTION SUMMARY
07/01/2020 Letter INSPECTION SUMMARY
07/09/2020 Letter INSPECTION SUMMARY
07/16/2020 Letter INSPECTION SUMMARY
09/16/2020 Letter INSPECTION SUMMARY
09/29/2020 Letter INSPECTION SUMMARY
09/29/2020 Letter INSPECTION SUMMARY
09/29/2020 Letter INSPECTION SUMMARY
11/23/2020 Letter INSPECTION SUMMARY
11/30/2020 Letter Codes Temporary Certificate of Occupancy
12/11/2020 Letter INSPECTION SUMMARY
03/18/2021 Letter INSPECTION SUMMARY
03/18/2021 Letter INSPECTION SUMMARY
03/18/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home