Summary
PRRES20193177
Building Permit - Residential
Certificate of Occupancy
DAVE RICHARDS HOME BUILDING INC
NEW SINGLE FAMILY
NEW HOUSE- COVERED DECK - UNFINISHED BASEMENT - SUSPENDED SLAB
10/29/2019
11/14/2019
08/12/2021
Locations
Contacts
DAVE RICHARDS HOME BUILDING INC, Address:PO BOX 1325  
DAVE RICHARDS HOMEBUILDING INC, Address:605 SW US HIGHWAY 40 #414, Phone:(816) 365-8034  
DAVE@DAVERICHARDSHOMES.COM  
BLUE VALLEY HEATING & COOLING LLC, Address:P O BOX 241, Phone:(816) 867-5122  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 10/31/2019 11/04/2019
Dylan Eppert
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
10/29/2019

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) PLESE PROVIDE UNFINISHED BASEMENT AND COVERED DECK SQUARE FOOTAGE ON CONSTRUCTION DRAWINGS.
Miscellaneous Correction
Corrective Action Required
10/29/2019

CONSTRUCTION DRAWINGS SHALL REFERENCE 2018 BUILDING CODE.
Miscellaneous Correction
Corrective Action Required
10/29/2019

CONSTRUCTION DRAWINGS SHOW 1101 NE GOSHEN DR. BUT IT SHOULD BE 1101 NE GOSHEN CT.
Plot Plan Review Approved 10/31/2019 10/29/2019
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,247.77 $1,247.77 Paid 11/14/2019
8331507-Sewer Connection Fee $420.00 $420.00 Paid 11/14/2019
Water Tap Fee $3,477.00 $3,477.00 Paid 11/14/2019
Water Meter Fee $425.02 $425.02 Paid 11/14/2019
Right of Way Permit Fee $80.00 $80.00 Paid 11/14/2019
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 11/14/2019
Not Ready Inspection Fee $50.00 $50.00 Paid 11/11/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 2/3/2020 at 1:50 PM 02/03/2020
Water Service Inspection - R Passed 2/4/2020 at 2:05 PM 02/04/2020
Erosion Control Inspection Residential Failed 2/12/2020 02/12/2020
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/12/2020
DEFICIENT EROSION CONTROL INSTALLATION. EROSION CONTROL SHALL BE INSTALLED ALONG THE BACK SIDE OF THE LOT **INSPECTION DENIED. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Failed 2/12/2020 2/12/2020 at 9:55 AM 02/12/2020
Misc
Corrective Action Required
02/12/2020
**INSPECTION DENIED. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Erosion Control Inspection Residential Passed 2/20/2020 02/20/2020
DCM2 ESC DEFICIENT INSTALLATION
Resolved
02/20/2020
DEFICIENT EROSION CONTROL INSTALLATION. EROSION CONTROL SHALL BE INSTALLED ALONG THE BACK SIDE OF THE LOT **INSPECTION DENIED. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Passed 2/20/2020 2/20/2020 at 9:15 AM 02/20/2020
Misc
Resolved
02/20/2020
**INSPECTION DENIED. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Gas Service Inspection - Residential Failed 7/7/2020 7/7/2020 07/07/2020
Misc
Corrective Action Required
07/07/2020
NOT READY
Electrical Service Inspection Passed 7/7/2020 7/7/2020 07/07/2020
All Rough Inspection - Residential Failed 7/7/2020 7/7/2020 at 7:50 AM 07/07/2020
Misc
Corrective Action Required
07/07/2020
**CLEAN MUD AND GRAVEL OFF STREET FRAMING: -Provide plan on site -Fb from roof entry wall into pantry -Install exterior door frame per security code -Tempered glass window required where located within two ft of the basement walkout door -Anchor basement sill plates per code; anchor columns -Install full support underneath point load on the left side of basement walkout door -Insulate first, then solid-block cantilevered joists above bearing wall -Basement exterior doors: full in void behind hinges and at strike plate side per security code -Make sure all brace walls are framed per plan ELECTRICAL: -Protect wiring at garage wall corner -Complete wiring into box in garage -Complete fireplace installation -Complete electrical in living room -Install inter system bonding terminal near service **OK TO INSULATE
Gas Service Inspection - Residential Failed 7/14/2020 07/14/2020
Misc
Corrective Action Required
07/07/2020
NOT READY
All Rough Inspection - Residential Failed 7/14/2020 7/14/2020 at 8:15 AM 07/14/2020
Misc
Corrective Action Required
07/07/2020
**CLEAN MUD AND GRAVEL OFF STREET. PLEASE INSTALL EROSION CONTROL ALONG THE STREET ON YOUR OTHER HOUSE (1113) FRAMING: -Provide plan on site -Fb entry wall into pantry from roof -Install exterior door frame per security code**If the deck door is within 2 ft of the windows, then those windows are required to be tempered glass windows -Tempered glass window required where located within two ft of the basement walkout door -Insulate first, then solid-block cantilevered joists above bearing wall -Make sure all brace walls are framed per plan ELECTRICAL: -Complete fireplace installation -Complete electrical in living room
Gas Service Inspection - Residential Passed 7/15/2020 07/15/2020
Misc
Resolved
07/15/2020
NOT READY
All Rough Inspection - Residential Not Ready 7/15/2020 7/15/2020 at 1:15 PM 07/15/2020
Misc
Corrective Action Required
07/14/2020
FRAMING: -Fb entry wall into pantry from roof **Not done -Install exterior door frame per security code**If the deck door is within 2 ft of the windows, then those windows are required to be tempered glass windows -Tempered glass window required where located within two ft of the basement walkout door -Insulate first, then solid-block cantilevered joists above bearing wall -Make sure all brace walls are framed per plan **Frame the basement PFH walls per plan ELECTRICAL: -Complete fireplace installation -Complete electrical in living room **NOTHING DONE, EXCEPT FOR LEAVING THE PLAN ON SITE. WASTED TRIP FEE ASSESSED **SUBMIT ENGINEER RECORD FOR FOOTING INSPECTION
Suspended Slab Inspection Passed 7/31/2020 (1:00) 7/31/2020 at 1:50 PM 07/31/2020
All Rough Inspection - Residential Partial 8/6/2020 8/6/2020 08/06/2020
Misc
Corrective Action Required
07/15/2020
-Tempered glass window, where required, will be checked at final -Make sure all brace walls are framed per plan **Nail sheathing and strap per plan detail **OK TO ROCK
Driveway Inspection Partial 8/21/2020 8/21/2020 08/21/2020
Misc
Informational
08/21/2020
8/21/20 Friday 12:00PM Driveway- forms and materials passed pre-inspection.
Driveway Inspection Passed 8/24/2020 8/24/2020 08/24/2020
Misc
Informational
08/21/2020
8/21/20 Friday 12:00PM Driveway- forms and materials passed pre-inspection.
Misc
Informational
08/24/2020
8/24/20 Monday 7:53AM Driveway- passed final inspection.
Piers/Caissons Inspection - Residential Passed 10/20/2020
Informational
10/20/2020
APEX INSPECTED AND APPROVED THE PIERS
All Rough Inspection - Residential Passed 10/20/2020
Misc
Resolved
10/20/2020
-Tempered glass window, where required, will be checked at final -Make sure all brace walls are framed per plan **Nail sheathing and strap per plan detail **OK TO ROCK
Occupancy Inspection - Codes Residential Failed 10/20/2020 10/20/2020 10/20/2020
Misc
Corrective Action Required
10/20/2020
7/15/20-REINSPECTION FEE ASSESSED
Misc
Corrective Action Required
10/20/2020
-Lawn irrigation permit required -Footing not inspected and approved by city. Have engineer submit inspection approval to city -As-graded plot plan is required -Raise water meter to grade level -Install downspout extensions -Make sure that the sewer tracer wire and port are installed and available at grade level -Install tamper-proof caps at AC valves -Support end of deck beam ; lag screw ledger board to rim band -Secure cooktop whip within 12” of j-box and cooktop connection -Install secondary locks for slide doors -Install breaker lock for oven -At basement walkout doors, install security strike plates with 3” screws fasten to jamb studs -Tempered glass window required where located within 2 ft of door edge -Protect SE cable running across bottom of joists -Cut off excessive ufer rebar; remove foundation wall metal ties -Securely support SE cable above water heater no more than 4.5 ft -Install maximum 30 amp breaker for AC
Occupancy Inspection - Codes Residential Failed 11/12/2020 11/11/2020 11/11/2020
Misc
Corrective Action Required
10/20/2020
7/15/20-REINSPECTION FEE ASSESSED
Misc
Corrective Action Required
10/20/2020
-Footing not inspected and approved by city. Have engineer submit inspection approval to city -Support end of deck beam; lag screw ledger board to rim band -At basement walkout doors, install security strike plates with 3” screws fasten to jamb studs; install 2-3" screw at each hinge -Tempered glass window required where located within 2 ft of door edge **RE-INSPECTION FEE ASSESSED ON 7/15/20 HAS NOT BEEN PAID FYI FOR SECURITY CODE: Sec. 7-1408.2. - Strike plates. Exterior door strike plates shall be a minimum of eighteen (18) gauge metal with four (4) offset screw holes. Strike plates shall be attached to wood with not less than three (3) inch wood screws, which shall have a minimum of one inch penetration into the nearest stud. Note: For side lighted units, refer to Section 7-1408.5. (Ord. No. 8584, § 1, 3-19-2019)
Footing Inspection - Residential Passed 11/12/2020
Informational
11/12/2020
FOOTING INSPECTED AND APPROVED BY ENGINEER
Occupancy Inspection - Codes Residential Temporary C of O 11/12/2020 11/12/2020
Misc
Resolved
11/12/2020
Misc
Corrective Action Required
11/11/2020
-Support end of deck beam; lag screw ledger board to rim band **DECK SHALL BE OFF-LIMIT UNTIL THE ISSUES ARE RESOLVED -Tempered glass window required where located within 2 ft of door edge
Plot Plan Inspection Passed 11/16/2020 11/16/2020
Occupancy Inspection - Codes Residential Full C of O 8/12/2021 8/12/2021 08/12/2021
Misc
Resolved
08/12/2021
-Support end of deck beam; lag screw ledger board to rim band **DECK SHALL BE OFF-LIMIT UNTIL THE ISSUES ARE RESOLVED -Tempered glass window required where located within 2 ft of door edge
Documents & Images
Date Uploaded File Type Document Name
10/29/2019 Letter Codes Residential Plan Review
10/29/2019 Letter Codes Residential Plan Review
11/14/2019 Receipt Receipt for transaction: 2019-007308
11/14/2019 Letter DS Building Permit
11/14/2019 Plot Plan DOC111419-011
02/03/2020 Letter INSPECTION SUMMARY
02/04/2020 Letter INSPECTION SUMMARY
02/12/2020 Letter INSPECTION SUMMARY
02/12/2020 Letter INSPECTION SUMMARY
02/20/2020 Letter INSPECTION SUMMARY
02/20/2020 Letter INSPECTION SUMMARY
06/26/2020 Engineer Report/Study Final_2020.06.10_DPier_LSMO_Pat Cochran Concrete
07/07/2020 Letter INSPECTION SUMMARY
07/07/2020 Letter INSPECTION SUMMARY
07/07/2020 Letter INSPECTION SUMMARY
07/14/2020 Letter INSPECTION SUMMARY
07/14/2020 Letter INSPECTION SUMMARY
07/15/2020 Letter INSPECTION SUMMARY
07/15/2020 Letter INSPECTION SUMMARY
07/31/2020 Letter INSPECTION SUMMARY
08/06/2020 Letter INSPECTION SUMMARY
08/21/2020 Letter INSPECTION SUMMARY
08/21/2020 Letter INSPECTION SUMMARY
08/24/2020 Letter INSPECTION SUMMARY
10/20/2020 Letter INSPECTION SUMMARY
10/20/2020 Letter INSPECTION SUMMARY
10/20/2020 Letter INSPECTION SUMMARY
11/11/2020 Letter Final_2020.06.10_DPier_LSMO_Pat Cochran Concrete 2
11/11/2020 Letter M-83-AG
11/11/2020 Letter INSPECTION SUMMARY
11/11/2020 Receipt Receipt for transaction:2020-007506
11/11/2020 Garys Fndn 1101 NE Goshen Ct Lee's Summit Mo 3rd Party Footing Inspection Report 12-27-19
11/12/2020 Letter Codes Temporary Certificate of Occupancy
11/12/2020 Letter INSPECTION SUMMARY
11/13/2020 Plot Plan APPROVED AS-BUILT
11/16/2020 Letter INSPECTION SUMMARY
07/28/2021 Letter Codes 10 Day Letter
08/09/2021 Engineer Report/Study DRHI 1101 NE Goshen Dr Monticello Lot 83 LSMO Deck Support at corner of overhang Report 5-20-21
08/12/2021 Letter Codes Final Certificate of Occupancy
08/12/2021 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home