Summary
PRRES20192822
Building Permit - Residential
Certificate of Occupancy
FOUSHEE HOMES INC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK CLOSED WITH OPEN VIOLATIONS OR EXCEEDED PERMIT LIMITS
10/01/2019
10/03/2019
02/27/2024
Locations
Contacts
FOUSHEE HOMES INC, Address:2511 S RINGO RD  
FOUSHEE HOMES INC, Address:2511 RINGO ROAD, Phone:(816) 918-2958  
MCDANIEL FURNACE & SHEET METAL, Address:2905 S M 291 FRONTAGE RD, Phone:(816) 373-6370  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
PREFERRED PLUMBING INC, Address:1664 NW 415TH RD, Phone:(816) 828-1680  
BF.FOUSHEE@GMAIL.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 10/03/2019 10/02/2019
Kim Brennan
Legal description
Corrective Action Required
10/01/2019

The legal description, including plat or phase number and lot number, and street address must be provided on the plot plan. Address shows NW and the plat shows NE Chapel Manor Dr.
Basement egress
Corrective Action Required
10/01/2019

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan.
Planning Review (RES) Approved 10/03/2019 10/02/2019
Kim Brennan
Miscellaneous Correction
Corrective Action Required
10/01/2019

Please label exterior materials
Planning Review (RES) Rejected 10/03/2019 10/01/2019
Victoria Nelson
Miscellaneous Correction
Corrective Action Required
10/01/2019

Please label exterior materials
Residential Plan Review Approved 10/03/2019 10/01/2019
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,025.04 $1,025.04 Paid 10/03/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 10/03/2019
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 10/03/2019
8331507-Sewer Connection Fee $390.00 $390.00 Paid 10/03/2019
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 10/03/2019
8350015-Water Meter Fee $425.02 $425.02 Paid 10/03/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/8/2019 10/8/2019 at 1:05 PM 10/08/2019
Underslab Plumbing Inspection - Residential Failed 10/23/2019 at 9:55 AM 10/23/2019
Misc
Corrective Action Required
10/23/2019
-NOT READY
Sewer Service Inspection - R Passed 10/29/2019 at 1:05 PM 10/29/2019
Water Service Inspection - R Passed 10/30/2019 10/30/2019 at 10:10 AM 10/30/2019
Underslab Plumbing Inspection - Residential Partial 11/5/2019 11/4/2019 at 8:55 AM 11/04/2019
Misc
Corrective Action Required
10/23/2019
-ADD SUPPORT STRAPS FOR PLUMBING. CAN CHECK LATER AT FLOOR INSPECTION
Miscellaneous Inspection Passed 12/9/2019 12/9/2019 at 8:20 AM 12/09/2019
Informational
12/09/2019
Garage portal framing OK
Electrical Service Inspection Passed 1/16/2020 01/16/2020
Gas Service Inspection - Residential Passed 1/16/2020 1/16/2020 01/16/2020
All Rough Inspection - Residential Failed 1/16/2020 at 1:35 PM 01/16/2020
Misc
Corrective Action Required
01/16/2020
**Erosion control required along property line to protect the adjacent house to the north FRAMING: -Solid block between rafters along exterior wall where the separation distance from neighboring house walls is less than 12 ft; or provide 1 hr fire protection underneath soffit -Install ceiling joists hangers above front bedroom -Install security blocking at exterior door jambs per security code -Solid block underneath roof-support beam at foyer wall -Fb basement wall from ceiling space -Solid block cantilevered joists above bearing wall PLUMBING: -Protect laundry plumbing at bottom wall plate ELECTRICAL: -Parallel electrical wiring inside return air space -Securely fasten wiring within 8” of exterior wall outlet boxes; secure wiring at interval no more than 4.5 ft, not just laying them unsecured within soffit framing -Protect wiring running across bottom of joists per code -Brace interior walls per plan MECHANICAL: -Connect duct to basement bathroom fan **OK TO INSULATE
Underslab Plumbing Inspection - Residential Passed 01/27/2020
Misc
Resolved
01/27/2020
-ADD SUPPORT STRAPS FOR PLUMBING. CAN CHECK LATER AT FLOOR INSPECTION
All Rough Inspection - Residential Failed 1/27/2020 1/27/2020 at 8:35 AM 01/27/2020
Misc
Corrective Action Required
01/16/2020
FRAMING: -Solid block between rafters along exterior wall where the separation distance from neighboring house walls is less than 12 ft; or provide 1 hr fire protection underneath soffit -Install ceiling joists hangers above front bedroom -Install security blocking at exterior door jambs per security code -Solid block underneath roof-support beam at foyer wall -Fb basement wall from ceiling space -Solid block cantilevered joists above bearing wall -Brace interior walls per plan **NOTHING HAS BEEN CORRECTED ON THE FRAMING PART
All Rough Inspection - Residential Failed 1/31/2020 1/31/2020 at 8:00 AM 01/31/2020
Misc
Corrective Action Required
01/27/2020
FRAMING: -Solid block between rafters along exterior wall where the separation distance from neighboring house walls is less than 12 ft; or provide 1 hr fire protection underneath soffit **Look at table IRC R302.1(1). When the roof soffit projection is less than ten ft from the adjacent house, then you either provide 1-hr fire protection on the underside of the roof soffit (no roof ventilation opening is allowed), or you solidblock between the rafters from wall top plates to the underside of the roof deck as allowd per note a. **Both sides of the house must comply with this table -Solid block underneath roof-support beam at foyer wall **About 3 ft left of the clothes washer drain pipe where the double studs supperting the lvl beam above, go down to the basement and soilidblock underneath the point load onto the I beam -Brace interior walls per plan **check later for screw gypsum board pattern
All Rough Inspection - Residential Partial 2/10/2020 2/10/2020 at 8:55 AM 02/10/2020
Misc
Corrective Action Required
01/31/2020
-Brace interior walls per plan **check later for gypsum board screw pattern **OK TO ROCK
All Rough Inspection - Residential Passed 2/26/2020 2/26/2020 at 8:10 AM 02/26/2020
Misc
Resolved
02/26/2020
-Brace interior walls per plan **check later for gypsum board screw pattern **OK TO ROCK
Driveway Inspection Partial 3/26/2020 (P.M.) 3/26/2020 03/26/2020
Misc
Informational
03/26/2020
Driveway - Forms and materials passed pre-inspection . Reschedule for final inspection 4/2/20.
Driveway Inspection Passed 3/26/2020 3/26/2020 04/22/2020
Misc
Informational
03/26/2020
Driveway - Forms and materials passed pre-inspection . Reschedule for final inspection 4/2/20.
Misc
Informational
04/22/2020
Driveway- passed final inspection.
Occupancy Inspection - Codes Residential Failed 6/19/2020 6/19/2020 at 1:35 PM 06/19/2020
Misc
Corrective Action Required
06/19/2020
-Obtain lawn irrigation permit -Obtain CMR approval for non-rated wall less than ten ft from the adjacent house to the south -Sidewalk not installed as shown on the plot plan -Paint exterior gas piping -Install tamper-proof caps at AC valves -Screw in the exterior doors embedded braces into studs with 3” screws. See the pre-drilled holes at frame -Window located within 24” of the hinge side of the master bedroom door must be tempered glass window -Secure water heater LFNC raceway -Fan headroom too close -Identify the sump pump receptacle as non-gfci
Occupancy Inspection - Codes Residential Temporary C of O 6/24/2020 6/24/2020 at 8:15 AM 06/24/2020
Misc
Corrective Action Required
06/19/2020
-Obtain CMR approval for non-rated wall less than ten ft from the adjacent house to the south -ADDENUM: Deck beam overspanned. Double 2x12 beam for 10 ft joists can only span 9 ft 5 inches. Please refer back to the house plan for beam size
Occupancy Inspection - Codes Residential Failed 6/24/2020 06/24/2020
Misc
Corrective Action Required
06/24/2020
NO CMR required for the set back of the house to property line, house was constructed and blocked as per code. 4064 will be built with the required 1hr exterior wall as it is over the required 10' set back. -ADDENDUM: Deck beam overspanned. Double 2x12 beam for 10 ft joists can only span 9 ft 5 inches. Please refer back to the house plan for beam size
Occupancy Inspection - Codes Residential Temporary C of O 11/10/2020 11/10/2020 11/10/2020
Misc
Corrective Action Required
06/24/2020
-ADDENDUM: Deck beam overspanned. Double 2x12 beam for 10 ft joists can only span 9 ft 5 inches. Please refer back to the house plan for beam size 11-9-2020 TCO Extendeded until 12-8-20 -Provide engineered letter for beam -Ledger bolts installed 16" OC in middle of ledger, not staggered high/ low
Documents & Images
Date Uploaded File Type Document Name
10/01/2019 Letter Codes Residential Plan Review
10/01/2019 Letter Codes Residential Plan Review
10/03/2019 Receipt Receipt for transaction: 2019-006597
10/03/2019 Letter DS Building Permit
10/03/2019 Plot Plan DOC100319-006
10/08/2019 Letter INSPECTION SUMMARY
10/23/2019 Letter INSPECTION SUMMARY
10/29/2019 Letter INSPECTION SUMMARY
10/30/2019 Letter INSPECTION SUMMARY
11/04/2019 Letter INSPECTION SUMMARY
12/09/2019 Letter INSPECTION SUMMARY
01/16/2020 Letter INSPECTION SUMMARY
01/16/2020 Letter INSPECTION SUMMARY
01/16/2020 Letter INSPECTION SUMMARY
01/27/2020 Letter INSPECTION SUMMARY
01/27/2020 Letter INSPECTION SUMMARY
01/31/2020 Letter INSPECTION SUMMARY
02/10/2020 Letter INSPECTION SUMMARY
02/26/2020 Letter INSPECTION SUMMARY
03/26/2020 Letter INSPECTION SUMMARY
04/22/2020 Letter INSPECTION SUMMARY
04/22/2020 Letter INSPECTION SUMMARY
06/19/2020 Letter INSPECTION SUMMARY
06/22/2020 Plot Plan updated plot plan
06/24/2020 Letter Codes Temporary Certificate of Occupancy
06/24/2020 Letter INSPECTION SUMMARY
10/29/2020 Letter Codes 10 Day Letter
11/04/2020 Engineer Report/Study Foushee Homes 4068 NE Chapel Manor Dr LSMO Deck Beam Issue 7-1-20
11/18/2020 Letter Codes Temporary Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home