PFEIFER HOMES INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
10/04/2018
10/09/2018
09/22/2021
Locations
Contacts
PFEIFER HOMES INC, Address:1550 SW MARKET ST STE 210  
PFEIFER HOMES INC, Address:1550 SW MARKET ST STE 210, Phone:(816) 524-5245  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
RICK@PFEIFERHOMES.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 10/08/2018 10/08/2018
Kim Brennan
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
10/04/2018

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) no smoke detector shown in bedroom #2
33 Identify braced wall locations and length of braced wall panel(s).
Corrective Action Required
10/04/2018

Identify braced wall locations and length of braced wall panel(s). (IRC Section R602.10)
Plot Plan Review Approved 10/08/2018 10/05/2018
Steve Conrick
As-graded plot plan
Corrective Action Required
10/05/2018

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. ***Please put "AS-GRADED PLOT PLAN IS REQUIRED PRIOR TO SODDING" in a bubble***
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,427.12 $1,427.12 Paid 10/09/2018
Right of Way Permit Fee $80.00 $80.00 Paid 10/09/2018
8331507-Sewer Connection Fee $630.00 $630.00 Paid 10/09/2018
Water Tap Fee $3,409.00 $3,409.00 Paid 10/09/2018
Water Meter Fee $408.37 $408.37 Paid 10/09/2018
Not Ready Inspection Fee $50.00 $50.00 Paid 03/26/2019
Not Ready Inspection Fee $50.00 $50.00 Paid 03/26/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/9/2018 (11:30) 11/9/2018 at 11:25 AM 11/09/2018
Underslab Plumbing Inspection - Residential Passed 11/30/2018 11/30/2018 at 10:25 AM 11/30/2018
Sewer Service Inspection - R Passed 12/4/2018 12/4/2018 at 1:10 PM 12/04/2018
Water Service Inspection - R Passed 12/4/2018 at 2:40 PM 12/04/2018
Gas Service Inspection - Residential Passed 3/8/2019 3/8/2019 03/08/2019
Electrical Service Inspection Passed 3/8/2019 3/8/2019 03/08/2019
All Rough Inspection - Residential Failed 3/8/2019 3/8/2019 at 1:15 PM 03/08/2019
Misc
Corrective Action Required
03/08/2019
**EROSION CONTROL SHALL BE INSTALLED ALONG PROPERTY LINE; 3/4" GRAVEL AT LOT ENTRANCE; STREET SHALL BE CLEANED FRAMING: -Block and nail sheathing to blocking at garage portal wall seams -At garage duct chase, install hanger support for joists -Fully support joists at laundry/garage wall -Install security blocking for exterior doors three stud spaces out -Install (3)2x4 support for lvl beam at rear dining -Plan calls for full height studs at great room exterior wall. Have engineer address -Install 3 studs support for lvl at fireplace/master bedroom wall -Solidblock cantilevered joists above front main floor bedroom -Provide attic access to roof space -Anchor basement sill plates per code; tighten all anchor nuts -Plan missing basement page **OK TO INSULATE
All Rough Inspection - Residential Not Ready 3/14/2019 3/14/2019 at 9:55 AM 03/14/2019
Misc
Corrective Action Required
03/08/2019
**EROSION CONTROL SHALL BE INSTALLED ALONG PROPERTY LINE; 3/4" GRAVEL AT LOT ENTRANCE; STREET SHALL BE CLEANED **14-MAR-THE ABOVE NOT DONE. MUD FLOWED FROM THIS LOT ONTO ADJACENT LOT. NOT-READY INSPECTION FEE ASSESSED FRAMING: -Block and nail sheathing to blocking at garage portal wall seams -At garage duct chase, install hanger support for joists -Fully support joists at laundry/garage wall -Install security blocking for exterior doors three stud spaces out -Install (3)2x4 support for lvl beam at rear dining -Plan calls for full height studs at great room exterior wall. Have engineer address -Install 3 studs support for lvl at fireplace/master bedroom wall -Solidblock cantilevered joists above front main floor bedroom -Provide attic access to roof space -Anchor basement sill plates per code; tighten all anchor nuts -Plan missing basement page **OK TO INSULATE
All Rough Inspection - Residential Failed 3/18/2019 3/18/2019 at 1:00 PM 03/18/2019
Misc
Corrective Action Required
03/14/2019
FRAMING: -Nail sheathing to blocking at garage portal wall seams -At garage duct chase, install hanger support for joists -Plan calls for full height studs at great room exterior wall. Have engineer address -Plan missing basement page **YOU CAN START HANGING ROCK FOR THE DWELLING AREA, IF THE ENGINEER IS OK WITH THE TRIPLE STUDS BETWEEN WINDOWS NOT BEING CONTINUOUS FROM FLOOR TO CEILING **DO NOT ROCK THE GARAGE CEILING **HAVE THE PLAN WITH THE BASEMENT PAGE ON SITE
All Rough Inspection - Residential Failed 3/20/2019 3/20/2019 at 8:40 AM 03/20/2019
Misc
Corrective Action Required
03/18/2019
FRAMING: -Nail sheathing to blocking at garage portal wall seams -At garage duct chase, install hanger support for joists -Plan calls for full height studs at great room exterior wall. Have engineer address -Plan missing basement page **YOU CAN START HANGING ROCK FOR THE DWELLING AREA, IF THE ENGINEER IS OK WITH THE TRIPLE STUDS BETWEEN WINDOWS NOT BEING CONTINUOUS FROM FLOOR TO CEILING **DO NOT ROCK THE GARAGE CEILING **HAVE THE PLAN WITH THE BASEMENT PAGE ON SITE **GARAGE ALREADY ROCKED. STILL NO PLAN ON SITE. DO NOT SCHEDULE A FINAL INSPECTION UNTIL YOU GET THE ALL-ROUGH APPROVED
All Rough Inspection - Residential Partial 3/27/2019 3/27/2019 at 10:10 AM 03/27/2019
Misc
Corrective Action Required
03/20/2019
**The fireplace gas shut-off valve shall be accessible. Check on final
Driveway Inspection Partial 5/9/2019 (Ready Now) 5/9/2019 05/09/2019
Misc
Informational
05/09/2019
Driveway passed pre-inspection of forms and materials.
All Rough Inspection - Residential Passed 7/31/2019 07/30/2019
Misc
Resolved
07/30/2019
**The fireplace gas shut-off valve shall be accessible. Check on final
Occupancy Inspection - Codes Residential Failed 7/31/2019 7/31/2019 at 3:25 PM 07/31/2019
Misc
Resolved
07/31/2019
**14-MAR-THE ABOVE NOT DONE. MUD FLOWED FROM THIS LOT ONTO ADJACENT LOT. NOT-READY INSPECTION FEE ASSESSED
Misc
Corrective Action Required
07/31/2019
LSCO #5029 PERMANENT EROSION CONTROL, VEGETATION, & DRAINAGE GRADING PER PLOT PLAN: POSITIVE DRAINAGE ENTIRE LOT FINE GRADE, SOD/SEED LOT; 6" MIN CLEARANCE TO WOOD FRAMING, SHEATHING, SIDING, TRIM, STUCCO; 3`-0 SPLASH BLOCKS OR LEADERS; UTILITY STRUCTURES AND ACCESS PLUGS/COVERS SET TO FINISH GRADE; SEWER SERVICE TRACER PORT AT GRADE; AC CONDENSER PAD LEVEL & 3" ABOVE GRADE.
Misc
Corrective Action Required
07/31/2019
NEC 370-20; IRC E3806.5-6 SET-BACK OF ELECTRICAL RECEPTACLE / SWITCH BOXES: 1/4" MAXIMUM SET-BACK @ NON-COMBUSTIBLE SURFACES. SEE AT KITCHEN BACKSPLASH
Misc
Corrective Action Required
07/31/2019
CLOSER REQUIRED TO FULLY CLOSE DOOR TO GARAGE
Occupancy Inspection - Codes Residential Failed 8/5/2019 at 9:45 AM 08/05/2019
Misc
Corrective Action Required
07/31/2019
LSCO #5029 PERMANENT EROSION CONTROL, VEGETATION, & DRAINAGE GRADING PER PLOT PLAN: POSITIVE DRAINAGE ENTIRE LOT FINE GRADE, SOD/SEED LOT; 6" MIN CLEARANCE TO WOOD FRAMING, SHEATHING, SIDING, TRIM, STUCCO; 3`-0 SPLASH BLOCKS OR LEADERS; UTILITY STRUCTURES AND ACCESS PLUGS/COVERS SET TO FINISH GRADE; SEWER SERVICE TRACER PORT AT GRADE; AC CONDENSER PAD LEVEL & 3" ABOVE GRADE.
Misc
Resolved
08/05/2019
NEC 370-20; IRC E3806.5-6 SET-BACK OF ELECTRICAL RECEPTACLE / SWITCH BOXES: 1/4" MAXIMUM SET-BACK @ NON-COMBUSTIBLE SURFACES. SEE AT KITCHEN BACKSPLASH
Misc
Resolved
08/05/2019
CLOSER REQUIRED TO FULLY CLOSE DOOR TO GARAGE
Misc
Corrective Action Required
08/05/2019
TEMPORARY EROSION CONTROL REQUIRED FOR TCO TO BE ISSUED
Occupancy Inspection - Codes Residential Temporary C of O 8/6/2019 8/6/2019 at 12:45 PM 08/06/2019
Misc
Corrective Action Required
08/05/2019
LSCO #5029 PERMANENT EROSION CONTROL, VEGETATION, & DRAINAGE GRADING PER PLOT PLAN: POSITIVE DRAINAGE ENTIRE LOT FINE GRADE, SOD/SEED LOT; 6" MIN CLEARANCE TO WOOD FRAMING, SHEATHING, SIDING, TRIM, STUCCO; 3`-0 SPLASH BLOCKS OR LEADERS; UTILITY STRUCTURES AND ACCESS PLUGS/COVERS SET TO FINISH GRADE; SEWER SERVICE TRACER PORT AT GRADE; AC CONDENSER PAD LEVEL & 3" ABOVE GRADE.
Misc
Resolved
08/06/2019
TEMPORARY EROSION CONTROL REQUIRED FOR TCO TO BE ISSUED
Occupancy Inspection - Codes Residential Full C of O 09/22/2021
Misc
Resolved
09/22/2021
LSCO #5029 PERMANENT EROSION CONTROL, VEGETATION, & DRAINAGE GRADING PER PLOT PLAN: POSITIVE DRAINAGE ENTIRE LOT FINE GRADE, SOD/SEED LOT; 6" MIN CLEARANCE TO WOOD FRAMING, SHEATHING, SIDING, TRIM, STUCCO; 3`-0 SPLASH BLOCKS OR LEADERS; UTILITY STRUCTURES AND ACCESS PLUGS/COVERS SET TO FINISH GRADE; SEWER SERVICE TRACER PORT AT GRADE; AC CONDENSER PAD LEVEL & 3" ABOVE GRADE.
Documents & Images
Date Uploaded File Type Document Name
10/04/2018 Letter Codes Residential Plan Review
10/05/2018 Letter Codes Residential Plan Review
10/09/2018 Receipt Receipt for transaction: 2018-006750
10/09/2018 Letter Codes Building Permit
10/11/2018 Plot Plan DOC101118-10112018094144
11/09/2018 Letter Inspection Summary
11/30/2018 Letter INSPECTION SUMMARY
12/04/2018 Letter INSPECTION SUMMARY
12/04/2018 Letter INSPECTION SUMMARY
03/08/2019 Letter INSPECTION SUMMARY
03/08/2019 Letter INSPECTION SUMMARY
03/08/2019 Letter INSPECTION SUMMARY
03/14/2019 Letter INSPECTION SUMMARY
03/18/2019 Letter INSPECTION SUMMARY
03/20/2019 Letter INSPECTION SUMMARY
03/26/2019 Receipt Receipt for transaction: 2019-001067
03/27/2019 Letter INSPECTION SUMMARY
07/31/2019 Letter INSPECTION SUMMARY
08/02/2019 Letter Pfeifer letter
08/05/2019 Letter INSPECTION SUMMARY
08/06/2019 Letter Codes Temporary Certificate of Occupancy
09/22/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home