Permit Application Status

PRCOM20220646


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20220646
Building Permit - Commercial
Certificate of Occupancy
LAKEWOOD RANCH LLC
CHANGE OF TENANT
TENANT FINISH FOR TAKEOUT/DELIVERY RESTAURANT
02/22/2022
06/16/2022
10/09/2022
04/11/2023
Locations
Contacts
D.I.G. CONSTRUCTION INC, Address:9539 MANCHESTER AVE, Phone:(913) 954-7131  
CompleteCooling@Yahoo.com, Address:CompleteCooling@Yahoo.com  
COMPLETE HCR LLC, Address:7211 JAMES A REED RD, Phone:(816) 442-3744  
ARNALDO ELECTRIC LLC, Address:719 KENSINGTON, Phone:(816) 510-0006  
COMPLETE HCR LLC, Address:7211 JAMES A REED RD, Phone:(816) 442-3744  
H | D Architecture, Address:15225 Broadmoor St  
LAKEWOOD RANCH LLC, Address:605 W 47TH ST # 200  
Reviews
Review Type Outcome Est. Completion Date Completed
Fire Plan Review Approved with Conditions 08/01/2022 08/01/2022
Jim Eden
Miscellaneous Correction
Corrective Action Required
07/25/2022

M] 607.2 Where required. A Type I hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that producegrease vapors. Exceptions: 1. Factory-built commercial exhaust hoods that are listed and labeled in accordance with UL 710, and installed in accordance with Section 304.1 of the International Mechanical Code, shall not be required to comply with Sections 507.1.5, 507.2.3, 507.2.5, 507.2.8, 507.3.1, 507.3.3, 507.4 and 507.5 of the International Mechanical Code. 2. Factory-built commercial cooking recirculating systems that are listed and labeled in accordance with UL 710B, and installed in accordance with Section 304.1 of the International Mechanical Code, shall not be required to comply with Sections 507.1.5, 507.2.3, 507.2.5, 507.2.8, 507.3.1, 507.3.3, 507.4 and 507.5 of the International Mechanical Code. Spaces in which such systems are located shall be considered to be kitchens and shall be ventilated in accordance with Table 403.3.1.1 of the International Mechanical Code. For the purpose of determining the floor area required to be ventilated, each individual appliance shall be considered as occupying not less than 100 square feet (9.3 m2). 3. Where cooking appliances are equipped with integral down-draft exhaust systems and such appliances and exhaust systems are listed and labeled for the application in accordance with NFPA 96, a hood shall not be required at or above them. 4. A Type I hood shall not be required for an electric cooking appliance where an approved testing agency provides documentation that the appliance effluent contains 5 mg/m3 or less of grease when tested at an exhaust flow rate of 500 cfm (0.236 m3/s) in accordance with UL 710B. Action required- Provide specifications for the hood and suppresion systems for review and approval.
Installation acceptance testing
Corrective Action Required
07/25/2022

2018 IFC 901.5- Installation acceptance testing. Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service mains and all other fire protection systems and appurtenances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the fire code official. The fire code official shall be notified before any required acceptance testing. The fire code official shall be notified 48 hours before any required acceptance test. Action required- Call (816) 969-1300 to schedule a test of the hood system.
Portable fire extinguishers for commercial cooking equipment.
Corrective Action Required
08/01/2022

2018 IFC 904.11.5- Portable fire extinguishers for commercial cooking equipment. Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial-type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. Action required- The K Class extinguisher shall be located with the manual pull for the hood system and be no closer than 10 feet and no farther than 20 feet from the hood. The ABC type extinguisher shall be located near the front or rear door. Verified at inspection.
Building Plan Review Approved with Conditions 08/01/2022 07/26/2022
Joe Frogge
Health Dept Inspection
Corrective Action Required
07/25/2022

For the Health Department inspection contact Deb Sees with the Jackson County Public Works Department, Environmental Health Division at (816) 847-7070. Health Department approval is required prior to receiving any type of Occupancy from the City of Lee's Summit. Action required: Comment is for informational purposes. 4/7/22 - not addressed 5/4/22 - acknowledged in letter
IBC 1606.2 Design dead load - structural
Corrective Action Required
07/25/2022

2018 IBC 1606.2 Design dead load. For purposes of design, the actual weights of materials of construction and fixed service equipment shall be used. In the absence of definite information, values used shall be subject to the approval of the building official. Action required: Provide engineer’s report and/or design to verify that existing roof structure will support additional load. 4/7/22 - not addressed for fan and makeup air unit 5/4/22 - deferred - Inspections not allowed to be scheduled unit letter and/or strengthening design is received and approved.
Licensed Contractors Approved 05/09/2022 06/10/2022
Development Center
LC - General Contractor
Resolved
06/10/2022

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor and an email address for the on-site contact which is where inspection reports will be sent. 4/7/22 - not addressed
LC - MEP Subs
Resolved
06/10/2022

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors. 4/7/22 - not addressed
Health Department Review Approved 05/11/2022
Joe Frogge
Fire Plan Review Approved with Conditions 05/09/2022 05/10/2022
Jim Eden
Portable fire extinguishers for commercial cooking equipment.
Resolved
05/10/2022

2018 IFC 904.11.5- Portable fire extinguishers for commercial cooking equipment. Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial-type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. Action required- Provide a K Class extinguisher under the manual pull station for the hood system.
Miscellaneous Correction
Corrective Action Required
05/02/2022

M] 607.2 Where required. A Type I hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that producegrease vapors. Exceptions: 1. Factory-built commercial exhaust hoods that are listed and labeled in accordance with UL 710, and installed in accordance with Section 304.1 of the International Mechanical Code, shall not be required to comply with Sections 507.1.5, 507.2.3, 507.2.5, 507.2.8, 507.3.1, 507.3.3, 507.4 and 507.5 of the International Mechanical Code. 2. Factory-built commercial cooking recirculating systems that are listed and labeled in accordance with UL 710B, and installed in accordance with Section 304.1 of the International Mechanical Code, shall not be required to comply with Sections 507.1.5, 507.2.3, 507.2.5, 507.2.8, 507.3.1, 507.3.3, 507.4 and 507.5 of the International Mechanical Code. Spaces in which such systems are located shall be considered to be kitchens and shall be ventilated in accordance with Table 403.3.1.1 of the International Mechanical Code. For the purpose of determining the floor area required to be ventilated, each individual appliance shall be considered as occupying not less than 100 square feet (9.3 m2). 3. Where cooking appliances are equipped with integral down-draft exhaust systems and such appliances and exhaust systems are listed and labeled for the application in accordance with NFPA 96, a hood shall not be required at or above them. 4. A Type I hood shall not be required for an electric cooking appliance where an approved testing agency provides documentation that the appliance effluent contains 5 mg/m3 or less of grease when tested at an exhaust flow rate of 500 cfm (0.236 m3/s) in accordance with UL 710B. Action required- Provide specifications for the hood and suppresion systems for review and approval.
Installation acceptance testing
Corrective Action Required
05/02/2022

2018 IFC 901.5- Installation acceptance testing. Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service mains and all other fire protection systems and appurtenances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the fire code official. The fire code official shall be notified before any required acceptance testing. The fire code official shall be notified 48 hours before any required acceptance test. Action required- Call (816) 969-1300 to schedule a test of the hood system.
Portable fire extinguishers - general
Resolved
05/10/2022

2018 IFC 906.2- General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Action required- Provide a minimum of one, 2A;10B;C fire extinguisher at a conspicuous location in a normal path of travel. Also provide a K Class fire extinguisher located at the manual pull for the hood system. The extinguisher and pull station shall be no closer than 10 feet and no farther than 20 feet from the protected appliance.
Building Plan Review Approved with Conditions 05/09/2022 05/10/2022
Joe Frogge
Health Dept Review
Resolved
05/10/2022

For the Health Department review contact Deb Sees with the Jackson County Public Works Department, Environmental Services Division, at (816) 847-7070. Health Department approval is required prior to receiving any type of building permit from the City of Lee's Summit. Action required: Comment is for informational purposes. 4/7/22 - not addressed 5/4/22 - acknowledged in letter
Health Dept Inspection
Corrective Action Required
05/02/2022

For the Health Department inspection contact Deb Sees with the Jackson County Public Works Department, Environmental Health Division at (816) 847-7070. Health Department approval is required prior to receiving any type of Occupancy from the City of Lee's Summit. Action required: Comment is for informational purposes. 4/7/22 - not addressed 5/4/22 - acknowledged in letter
IBC 1606.2 Design dead load - structural
Corrective Action Required
05/02/2022

2018 IBC 1606.2 Design dead load. For purposes of design, the actual weights of materials of construction and fixed service equipment shall be used. In the absence of definite information, values used shall be subject to the approval of the building official. Action required: Provide engineer’s report and/or design to verify that existing roof structure will support additional load. 4/7/22 - not addressed for fan and makeup air unit 5/4/22 - deferred - Inspections not allowed to be scheduled unit letter and/or strengthening design is received and approved.
IPC 802.1 Indirect/special waste
Resolved
05/04/2022

2018 IPC 802.1 Where required. Food-handling equipment, in other than dwelling units, clear-water waste, humidifiers, dish-washing machines and utensils, pots, pans and dishwashing sinks shall discharge though an indirect waste pipe as specified in Sections 802.1.1 through 802.1.8. Fixtures not required to be indirectly connected by this section and the exception to Section 301.6 shall be directly connected to the plumbing system in accordance with Chapter 7. Action required: 3-compartment sink must discharge via indirect waste. Modify design. 4/8/22 - note added but detail 2/P1.0 still shows solid connection
NEC Article 210.63 Heating, air-conditioning and refrigeration outlet
Resolved
05/04/2022

4/8/22 - comment added based on newly submitted roof plan. 2017 NEC Article 210.63 Heating, Air-Conditioning, and Refrigeration Equipment Outlet. A 125-volt, single-phase, 15- or 20-ampere-rated receptacle outlet shall be installed at an accessible location for the servicing of heating, air-conditioning, and refrigeration equipment. The receptacle shall be located on the same level and within 25 feet of the heating, air-conditioning, and refrigeration equipment. The receptacle outlet shall not be connected to the load side of the equipment disconnecting means. Action required: Provide receptacle within 25' of new makeup air unit or provide verification of existing.
Fire Plan Review Rejected 04/11/2022 04/12/2022
Jim Eden
Portable fire extinguishers for commercial cooking equipment.
Corrective Action Required
04/04/2022

2018 IFC 904.11.5- Portable fire extinguishers for commercial cooking equipment. Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial-type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. Action required- Provide a K Class extinguisher under the manual pull station for the hood system.
Miscellaneous Correction
Corrective Action Required
04/04/2022

M] 607.2 Where required. A Type I hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that producegrease vapors. Exceptions: 1. Factory-built commercial exhaust hoods that are listed and labeled in accordance with UL 710, and installed in accordance with Section 304.1 of the International Mechanical Code, shall not be required to comply with Sections 507.1.5, 507.2.3, 507.2.5, 507.2.8, 507.3.1, 507.3.3, 507.4 and 507.5 of the International Mechanical Code. 2. Factory-built commercial cooking recirculating systems that are listed and labeled in accordance with UL 710B, and installed in accordance with Section 304.1 of the International Mechanical Code, shall not be required to comply with Sections 507.1.5, 507.2.3, 507.2.5, 507.2.8, 507.3.1, 507.3.3, 507.4 and 507.5 of the International Mechanical Code. Spaces in which such systems are located shall be considered to be kitchens and shall be ventilated in accordance with Table 403.3.1.1 of the International Mechanical Code. For the purpose of determining the floor area required to be ventilated, each individual appliance shall be considered as occupying not less than 100 square feet (9.3 m2). 3. Where cooking appliances are equipped with integral down-draft exhaust systems and such appliances and exhaust systems are listed and labeled for the application in accordance with NFPA 96, a hood shall not be required at or above them. 4. A Type I hood shall not be required for an electric cooking appliance where an approved testing agency provides documentation that the appliance effluent contains 5 mg/m3 or less of grease when tested at an exhaust flow rate of 500 cfm (0.236 m3/s) in accordance with UL 710B. Action required- Specifications shall be provided for the both of the pizza ovens or provide Type ! protection over both.
Installation acceptance testing
Corrective Action Required
04/04/2022

2018 IFC 901.5- Installation acceptance testing. Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service mains and all other fire protection systems and appurtenances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the fire code official. The fire code official shall be notified before any required acceptance testing. The fire code official shall be notified 48 hours before any required acceptance test. Action required- Call (816) 969-1300 to schedule a test of the hood system.
Portable fire extinguishers - general
Corrective Action Required
04/04/2022

2018 IFC 906.2- General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Action required- Provide a minimum of one, 2A;10B;C fire extinguisher at a conspicuous location in a normal path of travel. Also provide a K Class fire extinguisher located at the manual pull for the hood system. The extinguisher and pull station shall be no closer than 10 feet and no farther than 20 feet from the protected appliance.
Building Plan Review Rejected 04/11/2022 04/08/2022
Joe Frogge
Health Dept Review
Corrective Action Required
04/04/2022

For the Health Department review contact Deb Sees with the Jackson County Public Works Department, Environmental Services Division, at (816) 847-7070. Health Department approval is required prior to receiving any type of building permit from the City of Lee's Summit. Action required: Comment is for informational purposes. 4/7/22 - not addressed
Health Dept Inspection
Corrective Action Required
04/04/2022

For the Health Department inspection contact Deb Sees with the Jackson County Public Works Department, Environmental Health Division at (816) 847-7070. Health Department approval is required prior to receiving any type of Occupancy from the City of Lee's Summit. Action required: Comment is for informational purposes. 4/7/22 - not addressed
Miscellaneous Correction
Resolved
04/08/2022

2018 IBC 2902.3.2 Prohibited toilet room location. Toilet rooms shall not open directly into a room used for the preparation of food for service to the public. Action required: Modify design to comply. (note: if restroom itself is modified it will need to be brought up to modern accessibility requirements.)
IBC 1606.2 Design dead load - structural
Corrective Action Required
04/04/2022

2018 IBC 1606.2 Design dead load. For purposes of design, the actual weights of materials of construction and fixed service equipment shall be used. In the absence of definite information, values used shall be subject to the approval of the building official. Action required: Provide engineer’s report and/or design to verify that existing roof structure will support additional load. 4/7/22 - not addressed for fan and makeup air unit
Misc
Resolved
04/08/2022

Inadequate information to complete review. Provide the following: - -
IMC 505.4 Makeup air required
Resolved
04/08/2022

2018 IMC 505.4 Makeup air required. Exhaust hood systems capable of exhausting in excess of 400 cfm shall be provided with makeup air at a rate approximately equal to the exhaust air rate. Such makeup air systems shall be equipped with a means of closure and shall be automatically controlled to start and operate simultaneously with the exhaust system. Action required: Provide makeup air or provide verification that hood is less than 400 cfm.
IPC 802.1 Indirect/special waste
Corrective Action Required
04/04/2022

2018 IPC 802.1 Where required. Food-handling equipment, in other than dwelling units, clear-water waste, humidifiers, dish-washing machines and utensils, pots, pans and dishwashing sinks shall discharge though an indirect waste pipe as specified in Sections 802.1.1 through 802.1.8. Fixtures not required to be indirectly connected by this section and the exception to Section 301.6 shall be directly connected to the plumbing system in accordance with Chapter 7. Action required: 3-compartment sink must discharge via indirect waste. Modify design. 4/8/22 - note added but detail 2/P1.0 still shows solid connection
Misc
Resolved
04/08/2022

2018 IPC 502.1 General. Water heaters shall be installed in accordance with the manufacturer’s installation instructions. Oil-fired water heaters shall conform to the requirements of this code and the International Mechanical Code. Electric water heaters shall conform to the requirements of this code and provisions of NFPA 70. Gas-fired water heaters shall conform to the requirements of the International Fuel Gas Code. Action required: Specify type and size of expansion tank at water heater.
IPC 403.1 Minimum number of fixtures
Resolved
04/08/2022

2018 IPC 403.1 Minimum number of fixtures. Plumbing fixtures shall be provided in the minimum number shown in Table 403.1, based on the actual use of the building or space. Uses not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined by the International Building Code. Action required: Provide mop sink.
NEC Article 210.63 Heating, air-conditioning and refrigeration outlet
Corrective Action Required
04/08/2022

4/8/22 - comment added based on newly submitted roof plan. 2017 NEC Article 210.63 Heating, Air-Conditioning, and Refrigeration Equipment Outlet. A 125-volt, single-phase, 15- or 20-ampere-rated receptacle outlet shall be installed at an accessible location for the servicing of heating, air-conditioning, and refrigeration equipment. The receptacle shall be located on the same level and within 25 feet of the heating, air-conditioning, and refrigeration equipment. The receptacle outlet shall not be connected to the load side of the equipment disconnecting means. Action required: Provide receptacle within 25' of new makeup air unit or provide verification of existing.
Licensed Contractors Rejected 04/11/2022 04/07/2022
Joe Frogge
LC - General Contractor
Corrective Action Required
04/04/2022

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor and an email address for the on-site contact which is where inspection reports will be sent. 4/7/22 - not addressed
LC - MEP Subs
Corrective Action Required
04/04/2022

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors. 4/7/22 - not addressed
Building Plan Review Rejected 03/04/2022 03/11/2022
Joe Frogge
Health Dept Review
Corrective Action Required
03/02/2022

For the Health Department review contact Deb Sees with the Jackson County Public Works Department, Environmental Services Division, at (816) 847-7070. Health Department approval is required prior to receiving any type of building permit from the City of Lee's Summit. Action required: Comment is for informational purposes.
Health Dept Inspection
Corrective Action Required
03/02/2022

For the Health Department inspection contact Deb Sees with the Jackson County Public Works Department, Environmental Health Division at (816) 847-7070. Health Department approval is required prior to receiving any type of Occupancy from the City of Lee's Summit. Action required: Comment is for informational purposes.
Miscellaneous Correction
Corrective Action Required
03/02/2022

2018 IBC 2902.3.2 Prohibited toilet room location. Toilet rooms shall not open directly into a room used for the preparation of food for service to the public. Action required: Modify design to comply. (note: if restroom itself is modified it will need to be brought up to modern accessibility requirements.)
IBC 1606.2 Design dead load - structural
Corrective Action Required
03/02/2022

2018 IBC 1606.2 Design dead load. For purposes of design, the actual weights of materials of construction and fixed service equipment shall be used. In the absence of definite information, values used shall be subject to the approval of the building official. Action required: Provide engineer’s report and/or design to verify that existing roof structure will support additional load.
Misc
Corrective Action Required
03/02/2022

Inadequate information to complete review. Provide the following: - complete hood designs - roof plan with all new equipment shown
IMC 505.4 Makeup air required
Corrective Action Required
03/02/2022

2018 IMC 505.4 Makeup air required. Exhaust hood systems capable of exhausting in excess of 400 cfm shall be provided with makeup air at a rate approximately equal to the exhaust air rate. Such makeup air systems shall be equipped with a means of closure and shall be automatically controlled to start and operate simultaneously with the exhaust system. Action required: Provide makeup air or provide verification that hood is less than 400 cfm.
IPC 802.1 Indirect/special waste
Corrective Action Required
03/11/2022

2018 IPC 802.1 Where required. Food-handling equipment, in other than dwelling units, clear-water waste, humidifiers, dish-washing machines and utensils, pots, pans and dishwashing sinks shall discharge though an indirect waste pipe as specified in Sections 802.1.1 through 802.1.8. Fixtures not required to be indirectly connected by this section and the exception to Section 301.6 shall be directly connected to the plumbing system in accordance with Chapter 7. Action required: 3-compartment sink must discharge via indirect waste. Modify design.
Misc
Corrective Action Required
03/11/2022

2018 IPC 502.1 General. Water heaters shall be installed in accordance with the manufacturer’s installation instructions. Oil-fired water heaters shall conform to the requirements of this code and the International Mechanical Code. Electric water heaters shall conform to the requirements of this code and provisions of NFPA 70. Gas-fired water heaters shall conform to the requirements of the International Fuel Gas Code. Action required: Specify type and size of expansion tank at water heater.
IPC 403.1 Minimum number of fixtures
Corrective Action Required
03/11/2022

2018 IPC 403.1 Minimum number of fixtures. Plumbing fixtures shall be provided in the minimum number shown in Table 403.1, based on the actual use of the building or space. Uses not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined by the International Building Code. Action required: Provide mop sink.
Licensed Contractors Rejected 03/04/2022 03/02/2022
Joe Frogge
LC - General Contractor
Corrective Action Required
03/02/2022

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor and an email address for the on-site contact which is where inspection reports will be sent.
LC - MEP Subs
Corrective Action Required
03/02/2022

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Fire Plan Review Rejected 03/04/2022 03/02/2022
Jim Eden
Installation acceptance testing
Corrective Action Required
03/02/2022

2018 IFC 901.5- Installation acceptance testing. Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service mains and all other fire protection systems and appurtenances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the fire code official. The fire code official shall be notified before any required acceptance testing. The fire code official shall be notified 48 hours before any required acceptance test. Action required- Call (816) 969-1300 to schedule a test of the hood system.
Miscellaneous Correction
Corrective Action Required
03/02/2022

M] 607.2 Where required. A Type I hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that producegrease vapors. Exceptions: 1. Factory-built commercial exhaust hoods that are listed and labeled in accordance with UL 710, and installed in accordance with Section 304.1 of the International Mechanical Code, shall not be required to comply with Sections 507.1.5, 507.2.3, 507.2.5, 507.2.8, 507.3.1, 507.3.3, 507.4 and 507.5 of the International Mechanical Code. 2. Factory-built commercial cooking recirculating systems that are listed and labeled in accordance with UL 710B, and installed in accordance with Section 304.1 of the International Mechanical Code, shall not be required to comply with Sections 507.1.5, 507.2.3, 507.2.5, 507.2.8, 507.3.1, 507.3.3, 507.4 and 507.5 of the International Mechanical Code. Spaces in which such systems are located shall be considered to be kitchens and shall be ventilated in accordance with Table 403.3.1.1 of the International Mechanical Code. For the purpose of determining the floor area required to be ventilated, each individual appliance shall be considered as occupying not less than 100 square feet (9.3 m2). 3. Where cooking appliances are equipped with integral down-draft exhaust systems and such appliances and exhaust systems are listed and labeled for the application in accordance with NFPA 96, a hood shall not be required at or above them. 4. A Type I hood shall not be required for an electric cooking appliance where an approved testing agency provides documentation that the appliance effluent contains 5 mg/m3 or less of grease when tested at an exhaust flow rate of 500 cfm (0.236 m3/s) in accordance with UL 710B. Action required- Provide plans for the Type 1 hood over the stove and specifications for the other cooking appliances. Additional Type 1 and 2 hoods may be required.
Portable fire extinguishers for commercial cooking equipment.
Corrective Action Required
03/02/2022

2018 IFC 904.11.5- Portable fire extinguishers for commercial cooking equipment. Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial-type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. Action required- Provide a K Class extinguisher under the manual pull station for the hood system.
Portable fire extinguishers - general
Corrective Action Required
03/02/2022

2018 IFC 906.2- General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Action required- Provide a minimum of one, 2A;10B;C fire extinguisher at a conspicuous location in a normal path of travel. Verified at inspection.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Change of Tenant $240.00 $240.00 Paid 06/16/2022
$7,177.50
7232302-Commercial License Tax Fee $13,770.00 $13,770.00 Paid 06/16/2022
$2,392.50
8331507-Sewer Connection Fee $90.00 $90.00 Paid 06/16/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 03/02/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Hood/Duct Inspection Failed 6/23/2022 6/23/2022 06/23/2022
Misc
Corrective Action Required
06/23/2022
**PROVIDE APPROVED SET OF PLAN ON SITE -PROVIDE LIGHT TEST WITH MIN 100 W LIGHT BULB
Gas Service Inspection - Commercial Failed 6/23/2022 06/23/2022
Misc
Corrective Action Required
06/23/2022
**PROVIDE APPROVED SET OF PLAN ON SITE -PRESSURE IS NOT HOLDING
Underslab Plumbing Inspection - Commercial Failed 6/23/2022 6/23/2022 06/23/2022
Misc
Corrective Action Required
06/23/2022
**PROVIDE APPROVED SET OF PLAN ON SITE -SUBMIT AS-BUILT UNDERSLAB PLUMBING PLAN
Underslab Plumbing Inspection - Commercial Failed 8/9/2022 8/9/2022 08/09/2022
Misc
Corrective Action Required
06/23/2022
**PROVIDE APPROVED SET OF PLAN ON SITE -SUBMIT AS-BUILT UNDERSLAB PLUMBING PLAN ** new plans on site from 8-2. Plans show 3" from floor drain to above slab for vent at east side of building for 2" VTR. 3" DWV and all floor sinks are flowing into Grease trap. Plans only show 3 compartment sink entering grease trap. Uncover all pipe for inspeciton. Rear portion at grease trap is covered and unable to see 3-4" fittings and piping design.
Underslab Plumbing Inspection - Commercial Failed 8/11/2022 08/11/2022
Misc
Corrective Action Required
08/09/2022
-Underslab plumbing not done per new plans dated 8-2. Vent mop sink. Locate cleanout to east end of 3" horizontal drain. Vent grease trap per plan -3" DWV and all floor sinks are flowing into Grease trap. Plans only show 3 compartment sink entering grease trap. -Uncover all pipe for inspeciton. Rear portion at grease trap is covered and unable to see 3-4" fittings and piping design.
Underslab Plumbing Inspection - Commercial Partial 8/22/2022 8/22/2022 08/22/2022
Misc
Corrective Action Required
08/11/2022
-Submit verification of the waste connections to the main building drain
In-wall Inspection Failed 8/29/2022 8/29/2022 08/29/2022
Misc
Corrective Action Required
08/29/2022
-At rear, complete in-wall DVW and protect DVW where within 1.25” of bottom wall track surface **OK TO ROCK THE FRONT COUNTER HALF WALLS AND OFFICE/STORAGE WALLS ONLY
Gas Service Inspection - Commercial Failed 8/29/2022 8/29/2022 08/29/2022
Misc
Corrective Action Required
06/23/2022
**PROVIDE ACCESS TO ALL GAS PIPING FOR INSPECTION
Gas Service Inspection - Commercial Failed 9/1/2022 9/1/2022 09/01/2022
Misc
Corrective Action Required
08/29/2022
-Installed gas piping is not per plan. There seems to be additional rooftop unit beside the RTU-1. Gas piping size and layout shall be per plan or resubmit new plan **9/1/22-This is a 3rd gas service inspection. Reinspection fee is assessed
Hood/Duct Inspection Failed 9/1/2022 9/1/2022 09/01/2022
Misc
Corrective Action Required
06/23/2022
**NOT READY FOR INSPECTION. PROVIDE PLAN FOR THE KITCHEN HOOD SYSTEM -COMPLETE GREASE DUCT AND PROVIDE LIGHT TEST WITH MIN 100 W LIGHT BULB
Gas Service Inspection - Commercial Not Ready 10/26/2022 10/26/2022 10/26/2022
Misc
Corrective Action Required
09/01/2022
-Installed gas piping is not per plan. There seems to be additional rooftop unit beside the RTU-1. Gas piping size and layout shall be per plan or resubmit new plan **9/1/22-This is a 3rd gas service inspection. Reinspection fee is assessed **10/26/22-Reinspection fee assessed. Revised plan not submitted to city and available on site. Do not schedule an inspection until the revised plan is approved
In-wall Inspection Passed 10/26/2022 10/26/2022
Misc
Resolved
10/26/2022
-At rear, complete in-wall DVW and protect DVW where within 1.25” of bottom wall track surface **OK TO ROCK THE FRONT COUNTER HALF WALLS AND OFFICE/STORAGE WALLS ONLY
Hood/Duct Inspection Partial 12/29/2022 12/29/2022 12/29/2022
Misc
Corrective Action Required
09/01/2022
GREASE DUCT LIGHT TEST-OK
Gas Service Inspection - Commercial Passed 12/29/2022 12/29/2022 12/29/2022
Misc
Resolved
12/29/2022
-Installed gas piping is not per plan. There seems to be additional rooftop unit beside the RTU-1. Gas piping size and layout shall be per plan or resubmit new plan **9/1/22-This is a 3rd gas service inspection. Reinspection fee is assessed **10/26/22-Reinspection fee assessed. Revised plan not submitted to city and available on site. Do not schedule an inspection until the revised plan is approved
Alternate Protection Systems Inspection Passed 1/27/2023 01/27/2023
Occupancy Inspection - Fire Failed 2/2/2023 2/2/2023 02/02/2023
Corrective Action Required
02/02/2023
Emergency Exit lights not operational, front and rear
Corrective Action Required
02/02/2023
Emergency lighting not operational front and rear. Cieling lights shown on plans not seen.
Corrective Action Required
02/02/2023
Breaker box front panel cover needs to be secured in place
Corrective Action Required
02/02/2023
Multiple open electrical boxes needs cover plate installed in ceiling and around ansul fire suppression system
Corrective Action Required
02/02/2023
Filters need to in place over cooking aplliences where ansul system installed
Corrective Action Required
02/02/2023
PLace address on back door
Occupancy Inspection - Codes Commercial Failed 2/2/2023 2/2/2023 02/02/2023
Misc
Corrective Action Required
02/02/2023
-Obtain signage permit -Fee of $75 has not been paid -Approval required from city Fire and Jackson county health department -Under-slab plumbing not approved -Securely fasten front exit light box and raceway within 3 ft of box -Provide EM and exit lighting per plan -Provide egress exit access lighting per code -Secure 3” DVW vertically at interval no more than ten ft -Install cover plates for receptacles at customer counter -Engineer shall address structural support for RTU -Install box extension for open j-box below storage shelf and install cover plate; Close all open j-boxes -Provide gfci protection for all receptacles in kitchen area -Provide smoke test for kitchen hood and MAU -Complete hood grease duct -Tighten all hood support nuts -Install cover plate for water heater receptacle -Complete water heater intake&exhaust -Install water heater P&T discharge pipe to within 6 ft of floor -Provide trap at water heater gas piping -Isolate copper water pipe from dissimilar metal support -Secure all EMT raceways within 3 ft of boxes; secure MC within 12” of boxes -Provide electrical load calculation for whole place. Power panel is currently supplied by 100 amp feeder. Plan requires 200 amp -Make sure all wiring to RTUs are sized per label -Label all panel breakers -Receptacle inside restroom shall be gfci-protected -Conductors terminations inside the walk-in coolers shall be covered inside enclosure -Seal all duct joints shall be fastened with min 3 equally spaced screws and sealed with mastic or approved UL tape -Complete installation of walk-in cooler rooftop units; provide max breaker size per labels -Paint all rooftop gas piping -MAU unit not in working condition. Gap around duct attachment to unit; loose and unused wiring inside, etc -Update plan for gas input into MAU -Complete installing grease duct fan. Make sure the unit height is per code, disconnect is installed, and grease reservoir is installed -Provide maximum 50 amp fuse for HVAC RTU -Provide a gfci-protected receptacle within 25 ft of all rooftop units -Provide sediment trap at all gas appliances
Electrical Service Inspection Failed 2/14/2023 2/14/2023 02/14/2023
Misc
Corrective Action Required
02/14/2023
**HAVE ENGINEER SUBMIT PANEL LOAD PLAN WITH ALL INSTALLED EQUIPMENTS. THE P1 SCHEDULE WILL NEED TO BE REVISED. PLAN NOT CALLS FOR 400 AMP SERVICE. THIS WILL ALSO NEED TO BE REVISED.
Electrical Service Inspection Failed 2/21/2023 2/21/2023 02/21/2023
Misc
Corrective Action Required
02/14/2023
-Install EGC sized for 200 amp overcurrent device -Install 200 amp overcurrent device at feeder disconnect -Install bushings at feeder entry into all enclosures -Support ENT every 6 ft and within 3 ft of J-box -PVC raceway cannot be installed where exposed to damage, unless identified for such use -Feeder tap conductors without overcurrent device must be installed inside metal raceway system -Install a jumper from the upper right EGC bus bar to the service grounded bus bar -ID ungrounded service conductors with color other than green
Occupancy Inspection - Codes Commercial Failed 02/21/2023
Misc
Corrective Action Required
02/02/2023
-Obtain signage permit -Fee of $75 has not been paid -Approval required from city Fire and Jackson county health department -Under-slab plumbing not approved -Securely fasten front exit light box and raceway within 3 ft of box -Provide egress exit discharge lighting at front per code -Engineer shall address structural support for RTU -Provide gfci protection for all receptacles in kitchen area -Provide smoke test for kitchen hood and MAU. -Submit performance test for the kitchen hood system for compliance with IMC 507&508 -Complete hood grease duct -Tighten all hood support nuts -Secure all EMT raceways within 3 ft of boxes; secure MC within 12” of boxes -Correct 200 amp electrical per “electrical service” inspection -Make sure all wiring to RTUs are sized per label -Label all panel breakers -Receptacle inside restroom shall be gfci-protected -Conductors terminations inside the walk-in coolers shall be covered inside enclosure -Complete installation of walk-in cooler rooftop units; provide max breaker size per labels -Paint all rooftop gas piping -MAU unit not in working condition. Gap around duct attachment to unit; loose and unused wiring inside, etc -Update plan for gas input into MAU -Complete installing grease duct fan. Make sure the unit height is per code, disconnect is installed, and grease reservoir is installed -Provide maximum 50 amp fuse for HVAC RTU -Provide a gfci-protected receptacle within 25 ft of all rooftop units -Provide sediment trap at all gas appliances
Electrical Service Inspection Passed 2/24/2023 2/24/2023 02/24/2023
Misc
Resolved
02/24/2023
-Support ENT every 6 ft and within 3 ft of J-box -PVC raceway cannot be installed where exposed to damage, unless identified for such use -Install a jumper from the upper right EGC bus bar to the service grounded bus bar -ID ungrounded service conductors with color other than green
Hood/Duct Inspection Passed 03/06/2023
Misc
Resolved
03/06/2023
GREASE DUCT LIGHT TEST-OK
Occupancy Inspection - Codes Commercial Failed 3/6/2023 3/6/2023 03/06/2023
Misc
Corrective Action Required
02/21/2023
-Approval required from city Fire and Jackson county health department -Under-slab plumbing not approved -Engineer shall address structural support for RTU -Provide smoke test for kitchen hood and MAU. -Submit performance test for the kitchen hood system for compliance with IMC 507&508 -Secure all EMT raceways within 3 ft of boxes; secure MC within 12” of boxes -Conductors terminations inside the walk-in coolers shall be covered inside enclosure **Secure flexible raceway within 12” of termination -Complete installation of walk-in cooler rooftop units; provide max breaker size per labels **15 amp for the one on the north side; 25 amp fuse for one on the south side; tape EGC with green tape -MAU unit not in working condition. **MAU is required to be automatically controlled to start and operate simultaneously with the exhaust system per IMC 508.1 -Complete installing grease duct fan. **Bond switch box -Support feeder PVC raceway every 6 ft -PVC raceway cannot be installed where exposed to damage, unless identified for such use
Underslab Plumbing Inspection - Commercial Passed 03/10/2023
Misc
Resolved
03/10/2023
-Submit verification of the waste connections to the main building drain
Occupancy Inspection - Codes Commercial Ready for Temp CO 3/10/2023 3/10/2023 03/10/2023
Misc
Corrective Action Required
03/06/2023
-Approval required from city Fire -Submit performance test for the kitchen hood system for compliance with IMC 507&508 -Complete installation of walk-in cooler rooftop units; provide max breaker size per labels **15 amp for the one on the north side; 25 amp fuse for one on the south side; tape EGC with green tape **TCO APPROVED FOR 30 DAYS
Occupancy Inspection - Fire Passed 3/10/2023 03/10/2023
Occupancy Inspection - Codes Commercial Full C of O 4/11/2023 4/11/2023 04/11/2023
Misc
Resolved
04/11/2023
-Approval required from city Fire -Submit performance test for the kitchen hood system for compliance with IMC 507&508 -Complete installation of walk-in cooler rooftop units; provide max breaker size per labels **15 amp for the one on the north side; 25 amp fuse for one on the south side; tape EGC with green tape **TCO APPROVED FOR 30 DAYS
Documents & Images
Date Uploaded File Type Document Name
02/22/2022 Application Form Feb 22, 11_17
03/11/2022 Letter DS P/R Corrections Document
04/04/2022 Plans 22-001_City Comments 1_2022-04-04
04/12/2022 Letter DS P/R Corrections Document
04/27/2022 Letter Fire Building Plan Review
05/02/2022 Plans 22-001_City Comments 2_2022-05-02
05/02/2022 Email PLAN REVIEW COMMENTS
06/01/2022 Letter Fire Building Plan Review
06/16/2022 Letter DS Building Permit
06/23/2022 Letter INSPECTION SUMMARY
06/23/2022 Letter INSPECTION SUMMARY
06/23/2022 Letter INSPECTION SUMMARY
08/02/2022 Approved Plans APPROVED PLANS
08/02/2022 Letter Fire Building Plan Review
08/02/2022 Letter Fire Building Plan Review
08/02/2022 Letter Fire Building Plan Review
08/02/2022 Letter Fire Building Plan Review
08/09/2022 Letter INSPECTION SUMMARY
08/11/2022 Letter INSPECTION SUMMARY
08/22/2022 Letter INSPECTION SUMMARY
08/29/2022 Letter License Tax Bill
08/29/2022 Letter INSPECTION SUMMARY
08/29/2022 Letter INSPECTION SUMMARY
08/29/2022 Letter INSPECTION SUMMARY
09/01/2022 Letter INSPECTION SUMMARY
09/01/2022 Letter INSPECTION SUMMARY
12/27/2022 Approved Plans approved - M10
12/29/2022 Letter INSPECTION SUMMARY
12/29/2022 Letter INSPECTION SUMMARY
02/02/2023 Letter Fire Loss Reduction Form
02/02/2023 Letter Fire Loss Reduction Form
02/02/2023 Letter Fire Loss Reduction Form
02/02/2023 Letter Fire Loss Reduction Form
02/02/2023 Letter INSPECTION SUMMARY
02/02/2023 Letter Fire Loss Reduction Form
02/14/2023 Letter INSPECTION SUMMARY
02/17/2023 Plans 2023 0216 Pizza Place - E10
02/21/2023 Letter INSPECTION SUMMARY
02/21/2023 Letter INSPECTION SUMMARY
02/24/2023 Letter INSPECTION SUMMARY
03/02/2023 Receipt Receipt for transaction: 2023-001191
03/06/2023 Letter INSPECTION SUMMARY
03/06/2023 Letter INSPECTION SUMMARY
03/10/2023 Engineer Report/Study Pizzaria Roof Evaluation
03/10/2023 Jackson County Health
03/10/2023 local pizza plumbing_
03/10/2023 Letter INSPECTION SUMMARY
04/11/2023 Engineer Report/Study IMG_8005
04/11/2023 Letter Codes Final Certificate of Occupancy
04/11/2023 Letter Field Certificate of Occupancy
02/22/2022 Plans 22-001_Permit Set_2022-01-23
10/26/2022 Letter INSPECTION SUMMARY
10/26/2022 Letter INSPECTION SUMMARY
06/16/2022 Receipt Receipt for transaction: 2022-004754
05/11/2022 Approved Plans approved plans
05/10/2022 Email jxn cty approval
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home