Permit Application Status

PRRES20245128


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20245128
Building Permit - Residential
Temporary Occupancy
DOMAIN TIMBERLAKE MULTISTATE LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - UNCOVERED DECK
09/27/2024
10/18/2024
04/06/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
DOMAIN TIMBERLAKE MULTISTATE LLC, Address:590 MADISON AVE FL 13TH  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 10/18/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/18/2024
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 10/18/2024
8331401-Water Tap Fee $3,973.00 $3,973.00 Paid 10/18/2024
8350015-Water Meter Fee $748.03 $748.03 Paid 10/18/2024
9110078-Valuation Fee New Single Family $1,577.74 $1,577.74 Paid 10/18/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/27/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 05/12/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 06/11/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sidewalk Inspection Pending
Misc
Informational
03/19/2025
3-19-25 DP. SW was formed, aggregate compacted, cross slopes in compliance. We have rain moving in quickly. Told the contractor to blanket their concrete if pouring today. If the rain messes up the concrete or cure, they will have to replace. If not pouring today, call back in for inspection on day they are pouring.
Occupancy Inspection - Codes Residential Pending
Misc
Corrective Action Required
06/11/2025
-address pending driveway and sidewalk inspections -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -address water meter pit missing ring and lid (ensure 14“-18” from top of meter to well ring lid, 2” min. Of gravel at bottom of meter well, clearance around meter for serviceability) -missing gutters
Misc
Corrective Action Required
06/11/2025
-address pending sidewalk inspection -splash blocks and sump pump discharge to extend 36” from foundation -address water meter pit missing ring and lid (ensure 14“-18” from top of meter to well ring lid, 2” min. Of gravel at bottom of meter well, clearance around meter for serviceability)
Sewer Service Inspection - R Passed 11/12/2024 11/12/2024 11/12/2024
Water Service Inspection - R Passed 11/14/2024 11/14/2024 11/14/2024
Erosion Control Inspection Residential Failed 11/26/2024 11/26/2024 11/26/2024
DCM5 ESC INSP DENIED
Corrective Action Required
11/26/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -Install proper ESC methods at perimeter and clean silt and debris from street
Underslab Plumbing Inspection - Residential Failed 11/26/2024 11/26/2024 11/26/2024
Misc
Corrective Action Required
11/26/2024
Inspection denied due to deficient erosion control
Footing Inspection - Residential Passed 11/26/2024 11/26/2024
Underslab Plumbing Inspection - Residential Passed 11/27/2024 11/27/2024 11/26/2024
Misc
Resolved
11/26/2024
Inspection denied due to deficient erosion control
Erosion Control Inspection Residential Partial 11/26/2024
Misc
Informational
11/26/2024
partial
All Rough Inspection - Residential Failed 1/23/2025 1/23/2025 01/23/2025
Misc
Corrective Action Required
01/23/2025
Garage PFH only approved to cover
All Rough Inspection - Residential Failed 1/24/2025 1/24/2025 01/24/2025
Misc
Corrective Action Required
01/23/2025
Garage PFH only approved to cover
Misc
Corrective Action Required
01/24/2025
Inspection denied Address needs to be re-established Erosion control must be in compliance
Electrical Service Inspection Failed 1/24/2025 1/24/2025 01/24/2025
Misc
Corrective Action Required
01/24/2025
Inspection denied erosion control must be in compliance Address needs to be re-established
Gas Service Inspection - Residential Failed 1/24/2025 1/24/2025 01/24/2025
Misc
Corrective Action Required
01/24/2025
Inspection denied erosion control must be in compliance Address needs to be re-established
Erosion Control Inspection Residential Failed 01/24/2025
Misc
Resolved
01/24/2025
partial
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
01/24/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
01/24/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
01/24/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. Clean trash and debris from lot Maintain straw waddles Re-establish address
Gas Service Inspection - Residential Passed 1/28/2025 1/28/2025 01/28/2025
Misc
Resolved
01/28/2025
Inspection denied erosion control must be in compliance Address needs to be re-established
Electrical Service Inspection Passed 1/28/2025 1/28/2025 01/28/2025
Misc
Resolved
01/28/2025
Inspection denied erosion control must be in compliance Address needs to be re-established
All Rough Inspection - Residential Failed 1/28/2025 1/28/2025 01/28/2025
Misc
Resolved
01/28/2025
Garage PFH only approved to cover
Misc
Resolved
01/28/2025
Inspection denied Address needs to be re-established Erosion control must be in compliance
Misc
Corrective Action Required
01/28/2025
-anchor bolts to be in the middle 1/3 of sill plate -nail plate under header at pfh to header above -address studs over bed at primary bath -install all roof boots -south gable truss missing lateral bracing -missing stud at foyer/bathroom wall -anchor and install all columns in basement -fire block all furr down ends in basement -all vertical fire blocking every ten 10’ in basement (where using unfaced insulation it must be packed tightly and securely )
All Rough Inspection - Residential Passed 1/31/2025 1/31/2025 01/31/2025
Misc
Resolved
01/31/2025
-nail plate under header at pfh to header above -address studs over bed at primary bath -south gable truss missing lateral bracing -missing stud at foyer/bathroom wall -anchor and install all columns in basement -fire block all furr down ends in basement -all vertical fire blocking every ten 10’ in basement (where using unfaced insulation it must be packed tightly and securely )
Driveway Inspection Partial 3/18/2025 03/18/2025
Misc
Informational
03/18/2025
3-18-25 DP. DW was formed. Aggregate compacted. Approved to pour. There is sidewalk on the side of the house but not across the DW approach
Piers/Caissons Inspection - Residential Passed 3/19/2025 03/19/2025
Sidewalk Inspection Partial 3/19/2025 03/19/2025
Misc
Informational
03/19/2025
3-19-25 DP. SW was formed, aggregate compacted, cross slopes in compliance. We have rain moving in quickly. Told the contractor to blanket their concrete if pouring today. If the rain messes up the concrete or cure, they will have to replace. If not pouring today, call back in for inspection on day they are pouring.
Occupancy Inspection - Codes Residential Failed 3/24/2025 3/24/2025 03/24/2025
Misc
Corrective Action Required
03/24/2025
NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IN COMPLIANCE -address pending driveway and sidewalk inspections -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -address water meter pit missing ring and lid (ensure 14“-18” from top of meter to well ring lid, 2” min. Of gravel at bottom of meter well, clearance around meter for serviceability) -missing gutters -all outlets in unfinished spaces must be gfci protected of single pull receptacle and labeled -complete kitchen hood install -missing knock outs in panel -missing multiple afci breakers -set screw needs to be sheared off at water antisiphon device
Erosion Control Inspection Residential Failed 03/24/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
03/24/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
03/24/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
DCM2 ESC DEFICIENT INSTALLATION
Resolved
03/24/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. Clean trash and debris from lot Maintain straw waddles Re-establish address
Misc
Corrective Action Required
03/24/2025
Missing section of erosion control at SE corner of lot
Occupancy Inspection - Codes Residential Failed 3/26/2025 3/26/2025 03/26/2025
Misc
Corrective Action Required
03/24/2025
-address pending driveway and sidewalk inspections -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -address water meter pit missing ring and lid (ensure 14“-18” from top of meter to well ring lid, 2” min. Of gravel at bottom of meter well, clearance around meter for serviceability) -missing gutters -all outlets in unfinished spaces must be gfci protected or single pull receptacle and labeled -missing multiple afci breakers (kitchen circuits)
Occupancy Inspection - Codes Residential Ready for Temp CO 3/27/2025 3/27/2025 03/27/2025
Misc
Corrective Action Required
03/26/2025
-address pending driveway and sidewalk inspections -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -address water meter pit missing ring and lid (ensure 14“-18” from top of meter to well ring lid, 2” min. Of gravel at bottom of meter well, clearance around meter for serviceability) -missing gutters
Driveway Inspection Passed 3/27/2025 3/27/2025 03/27/2025
Misc
Informational
03/18/2025
3-18-25 DP. DW was formed. Aggregate compacted. Approved to pour. There is sidewalk on the side of the house but not across the DW approach 3-27-25 Dustin A, w has been poured to city specs. Pass
Erosion Control Inspection Residential Failed 5/7/2025 5/7/2025 05/07/2025
Misc
Resolved
05/07/2025
Missing section of erosion control at SE corner of lot
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/07/2025
5/7/25 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Provide BMPs at perimeter, clean silt and debris from street
Erosion Control Inspection Residential Partial 5/12/2025 5/12/2025 05/12/2025
DCM3 ESC REQUIRED 2 DAY
Resolved
05/12/2025
5/7/25 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Provide BMPs at perimeter, clean silt and debris from street
Plot Plan Inspection Passed 5/12/2025 05/12/2025
Occupancy Inspection - Codes Residential Ready for Temp CO 5/12/2025 05/12/2025
Misc
Corrective Action Required
03/27/2025
-address pending driveway and sidewalk inspections -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -address water meter pit missing ring and lid (ensure 14“-18” from top of meter to well ring lid, 2” min. Of gravel at bottom of meter well, clearance around meter for serviceability) -missing gutters
Erosion Control Inspection Residential Passed 6/3/2025 06/03/2025
Occupancy Inspection - Codes Residential Failed 6/3/2025 6/3/2025 06/03/2025
Misc
Corrective Action Required
05/12/2025
-address pending driveway and sidewalk inspections -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -address water meter pit missing ring and lid (ensure 14“-18” from top of meter to well ring lid, 2” min. Of gravel at bottom of meter well, clearance around meter for serviceability) -missing gutters
Misc
Corrective Action Required
06/03/2025
-address pending sidewalk inspection -splash blocks and sump pump discharge to extend 36” from foundation -address water meter pit missing ring and lid (ensure 14“-18” from top of meter to well ring lid, 2” min. Of gravel at bottom of meter well, clearance around meter for serviceability)
Occupancy Inspection - Codes Residential Ready for Temp CO 6/11/2025 06/11/2025
Misc
Corrective Action Required
06/03/2025
-address pending driveway and sidewalk inspections -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -address water meter pit missing ring and lid (ensure 14“-18” from top of meter to well ring lid, 2” min. Of gravel at bottom of meter well, clearance around meter for serviceability) -missing gutters
Misc
Corrective Action Required
06/03/2025
-address pending sidewalk inspection -splash blocks and sump pump discharge to extend 36” from foundation -address water meter pit missing ring and lid (ensure 14“-18” from top of meter to well ring lid, 2” min. Of gravel at bottom of meter well, clearance around meter for serviceability)
Documents & Images
Date Uploaded File Type Document Name
09/27/2024 HT #186 - PERMIT APP
09/30/2024 Permit Codes Residential Plan Review
09/30/2024 Approved Plans APPROVED TRUSS LAYOUT
09/30/2024 Approved Plans APPROVED TRUSS PACKAGE
10/08/2024 Permit Codes Residential Plan Review
10/18/2024 Approved Plans APPROVED PLANS
10/18/2024 Approved Plans APPROVED PLOT PLAN
10/18/2024 Permit Codes Residential Plan Review
10/18/2024 Permit Codes Residential Plan Review
10/18/2024 Permit DS Building Permit
10/18/2024 Receipt Receipt for transaction:2024-008423
11/12/2024 Letter INSPECTION SUMMARY
11/14/2024 Letter INSPECTION SUMMARY
11/26/2024 Letter INSPECTION SUMMARY
11/26/2024 Letter INSPECTION SUMMARY
11/26/2024 3221 SW Arboridge Cir LSMO Footing Inspection Report 10-23-24
11/26/2024 Letter INSPECTION SUMMARY
11/26/2024 Letter INSPECTION SUMMARY
11/26/2024 Letter INSPECTION SUMMARY
01/07/2025 Approved Plans APPROVED TRUSS PACKAGE
01/23/2025 Letter INSPECTION SUMMARY
01/24/2025 Letter INSPECTION SUMMARY
01/24/2025 Letter INSPECTION SUMMARY
01/24/2025 Letter INSPECTION SUMMARY
01/24/2025 Letter INSPECTION SUMMARY
01/28/2025 Letter INSPECTION SUMMARY
01/28/2025 Letter INSPECTION SUMMARY
01/28/2025 Letter INSPECTION SUMMARY
01/31/2025 Letter INSPECTION SUMMARY
03/18/2025 Letter INSPECTION SUMMARY
03/19/2025 Letter INSPECTION SUMMARY
03/19/2025 Letter INSPECTION SUMMARY
03/24/2025 Letter INSPECTION SUMMARY
03/24/2025 Letter INSPECTION SUMMARY
03/26/2025 Letter INSPECTION SUMMARY
03/27/2025 Letter INSPECTION SUMMARY
03/27/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/27/2025 Receipt Receipt for transaction:2025-001838
03/27/2025 Letter INSPECTION SUMMARY
04/21/2025 Application Form TCO EXTENSION REQUEST
05/07/2025 Letter INSPECTION SUMMARY
05/07/2025 Letter INSPECTION SUMMARY
05/12/2025 Letter INSPECTION SUMMARY
05/12/2025 Letter INSPECTION SUMMARY
05/12/2025 Letter INSPECTION SUMMARY
05/12/2025 Certificate/License Codes Temporary Certificate of Occupancy
05/12/2025 Receipt Receipt for transaction:2025-003148
06/03/2025 Letter INSPECTION SUMMARY
06/03/2025 Letter INSPECTION SUMMARY
06/11/2025 Letter INSPECTION SUMMARY
06/11/2025 Certificate/License Codes Temporary Certificate of Occupancy
06/11/2025 Receipt Receipt for transaction:2025-004400
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home