Permit Application Status

PRRES20241067


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20241067
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. WALKOUT BASEMENT. COVERED DECK. ROOF TRUSSES.
03/07/2024
03/19/2024
09/10/2024
12/20/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
TYLER@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $3,760.00 $3,760.00 Paid 03/19/2024
Water Meter Fee $680.46 $680.46 Paid 03/19/2024
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 03/19/2024
Right of Way Permit Fee $85.00 $85.00 Paid 03/19/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 03/19/2024
Valuation Fee New Single Family $2,220.58 $2,220.58 Paid 03/19/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 09/11/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 09/11/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 09/11/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 09/11/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 09/11/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 09/11/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 09/11/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 09/11/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 11/15/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 11/15/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 11/20/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/3/2024 5/3/2024 05/03/2024
Misc
Informational
05/03/2024
Footing approved by Derek Perez on 4/26/24
Erosion Control Inspection Residential Failed 06/11/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/11/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -MAINTAIN SILT FENCE AT PERIMETER
Erosion Control Inspection Residential Failed 06/12/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/11/2024
**6/11/24 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -MAINTAIN SILT FENCE AT PERIMETER
DCM5 ESC INSP DENIED
Corrective Action Required
06/12/2024
**6/12/24 REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Underslab Plumbing Inspection - Residential Failed 6/12/2024 6/12/2024 06/12/2024
Misc
Corrective Action Required
06/12/2024
Inspection denied due to failed erosion control on 6/11/24 -Provide adequate erosion control methods
Sewer Service Inspection - R Passed 6/13/2024 6/13/2024 06/13/2024
Water Service Inspection - R Passed 6/17/2024 6/17/2024 06/17/2024
Underslab Plumbing Inspection - Residential Failed 6/19/2024 6/19/2024 06/19/2024
Misc
Corrective Action Required
06/12/2024
-Complete shower trap
Erosion Control Inspection Residential Partial 6/19/2024 6/19/2024 06/19/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
06/19/2024
**6/11/24 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -MAINTAIN SILT FENCE AT PERIMETER
DCM5 ESC INSP DENIED
Resolved
06/19/2024
**6/12/24 REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Misc
Informational
06/19/2024
6/19/24 -BMPs in compliance at time of inspection
Underslab Plumbing Inspection - Residential Passed 06/20/2024
Misc
Resolved
06/20/2024
-Complete shower trap
All Rough Inspection - Residential Not Ready 7/19/2024 7/19/2024 07/19/2024
Misc
Corrective Action Required
07/19/2024
Not ready fee assessed -Garage portal already covered. Uncover all items for inspection -Provide adequate erosion control before further inspeciton
Erosion Control Inspection Residential Failed 7/19/2024 7/19/2024 07/19/2024
Misc
Resolved
07/19/2024
6/19/24 -BMPs in compliance at time of inspection
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/19/2024
7/19/24 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Restore silt fence at perimeter and clean silt from street
All Rough Inspection - Residential Partial 7/24/2024 7/24/2024 07/24/2024
Misc
Resolved
07/24/2024
Not ready fee assessed -Garage portal already covered. Uncover all items for inspection -Provide adequate erosion control before further inspeciton
Misc
Informational
07/24/2024
7/24/24 In compliance at time of inspection
Erosion Control Inspection Residential Partial 7/24/2024 7/24/2024 07/24/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
07/24/2024
7/19/24 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Restore silt fence at perimeter and clean silt from street
Misc
Informational
07/24/2024
In compliance at time of inspection
All Rough Inspection - Residential Not Ready 07/24/2024
Misc
Corrective Action Required
07/24/2024
7/24/24 Portal framing only -Portal frame is still covered. Not ready
All Rough Inspection - Residential Failed 8/1/2024 8/1/2024 08/01/2024
Misc
Informational
08/01/2024
PFH exterior only ok to cover
Erosion Control Inspection Residential Partial 08/01/2024
Misc
Informational
07/24/2024
In compliance at time of inspection
Erosion Control Inspection Residential Partial 8/21/2024 8/21/2024 08/21/2024
Misc
Resolved
08/21/2024
In compliance at time of inspection
Miscellaneous Correction
Informational
08/21/2024
Full erosion control measures are in place and must be maintained until CofO
All Rough Inspection - Residential Not Ready 8/21/2024 8/21/2024 08/21/2024
Misc
Informational
08/01/2024
PFH exterior only ok to cover
Miscellaneous Correction
Corrective Action Required
08/21/2024
City approved sealed plans are not on site at the time of all rough inspection City approved plans must be on site and remain until CofO Not ready for inspection
Electrical Service Inspection Passed 8/22/2024 8/22/2024 08/22/2024
Erosion Control Inspection Residential Partial 8/22/2024 8/22/2024 08/22/2024
Miscellaneous Correction
Informational
08/21/2024
Full erosion control measures are in place and must be maintained until CofO
All Rough Inspection - Residential Not Ready 8/22/2024 8/22/2024 08/22/2024
Misc
Resolved
08/22/2024
PFH exterior only ok to cover
Miscellaneous Correction
Corrective Action Required
08/21/2024
8/22/24 House is not ready for inspection. List is incomplete. Address all of the following items before rescheduling: -Provide 2 rows of 16d sinkers at 3” oc at top plate to pfh header per detail -Anchor bolts to be in middle third of plate -Min 2 anchor bolts per plate-by column and at step downs -Tighten all anchor bolts -Solid shim under exterior wall studs not touching bottom plate or sister full length bearing studs at single car garage -Fireblock top of dead space in garage -Use approved materials for ceiling line fireblocking at fur down in garage -Install all missing LIB -Missing truss hold down connections on garage side wall -Holes drilled closer than 2” to bottom of joists for electrical throughout garage -Fireblock top of all dead spaces -Protect pex line at fridge bottom plate -Install (2) 2x4s and H2.5 under GT locations in garage per plan -Seal bottom plate penetration at owner’s entry -Missing LUS 24 hangers at K3 and K4 trusses at garage -Nail exterior sheathing at double car bay -Solid block and nail all horizontal seams in exterior sheathing -Seal all plate penetrations -3 studs required at all exterior corners in basement -Anchor all columns in basement -Install security blocking at all entry doors per LS Chapter 7
Erosion Control Inspection Residential Failed 8/28/2024 8/28/2024 08/28/2024
Miscellaneous Correction
Resolved
08/28/2024
Full erosion control measures are in place and must be maintained until CofO
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/28/2024
8/28/24 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -RESTORE SILT FENCE ST FRONT OF LOT -MAINTAIN GRAVEL FILTER
All Rough Inspection - Residential Not Ready 8/28/2024 8/28/2024 08/28/2024
Miscellaneous Correction
Corrective Action Required
08/22/2024
8/28/24 -PROVIDE CITY APPROVED, STAMPED PLANS FOR INSPECTION. PLANS ARE REQUIRED TO BE ON SITE AT ALL INSPECTIONS. NOT READY *ALSO NOTE THAT FIREBLOCKING AT DEAD SPACES IS STILL INCOMPLETE AND THAT MATERIALS USED AT SOFFIT LINE IN GARAGE ARE NOT APPROVED FOR FIREBLOCKING PER R302.11.1 8/22/24 House is not ready for inspection. List is incomplete. Address all of the following items before rescheduling: -Provide 2 rows of 16d sinkers at 3” oc at top plate to pfh header per detail -Anchor bolts to be in middle third of plate -Min 2 anchor bolts per plate-by column and at step downs -Tighten all anchor bolts -Solid shim under exterior wall studs not touching bottom plate or sister full length bearing studs at single car garage -Fireblock top of dead space in garage -Use approved materials for ceiling line fireblocking at fur down in garage -Install all missing LIB -Missing truss hold down connections on garage side wall -Holes drilled closer than 2” to bottom of joists for electrical throughout garage -Fireblock top of all dead spaces -Protect pex line at fridge bottom plate -Install (2) 2x4s and H2.5 under GT locations in garage per plan -Seal bottom plate penetration at owner’s entry -Missing LUS 24 hangers at K3 and K4 trusses at garage -Nail exterior sheathing at double car bay -Solid block and nail all horizontal seams in exterior sheathing -Seal all plate penetrations -3 studs required at all exterior corners in basement -Anchor all columns in basement -Install security blocking at all entry doors per LS Chapter 7
Piers/Caissons Inspection - Residential Passed 9/4/2024 9/4/2024 09/04/2024
Misc
Informational
09/04/2024
Approved by Everstead on 8/26/24
All Rough Inspection - Residential Not Ready 9/4/2024 9/4/2024 09/04/2024
Miscellaneous Correction
Corrective Action Required
08/28/2024
See R302.11.1 for approved fire blocking materials -Provide 2 rows of 16d sinkers at 3” oc at top plate to pfh header per detail -Anchor bolts to be in middle third of plate (see between garage doors) -Min 2 anchor bolts per plate-by column and at step downs -Use approved materials for ceiling line fireblocking at fur down in garage -Holes drilled closer than 2” to bottom of joists for electrical throughout garage (have engineer address fix) -Fireblock top of all dead spaces(seals gaps) -Protect pex line at fridge bottom plate -Install (2) 2x4s and H2.5 under GT locations in garage per plan -nail exterior sheathing at double car bay -solid block at cantilever above dining room -missing truss hold downs above front entry -nail exterior wall corners to plans and code -seal dead space at bath 3 -seal top plate penetration bed 4 -missing multiple hangers and bracing on trusses throughout 2nd floor -add stud where missing at wall in closet/ bath 2 wall -missing hold down on trusses above bed 2 -Solid block and nail all horizontal seams in exterior sheathing (see walk in closet 2nd floor and check throughout) -Seal all plate penetrations -3 studs required at all exterior corners in basement -sister all over notched exterior wall studs in basement where notched for anchor bolts -anchor bolts to be in the middle 1/3 of sill plate in basement -missing (3) 2x10 SW corner of basement and at stairs -missing solid blocking under kitchen island -address all holes drilled closer than 2” to one another throughout (see 1st floor and basement)
Erosion Control Inspection Residential Partial 9/9/2024 09/09/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
09/09/2024
8/28/24 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -RESTORE SILT FENCE ST FRONT OF LOT -MAINTAIN GRAVEL FILTER
Misc
Informational
09/09/2024
In conpliance at time of inspection
All Rough Inspection - Residential Not Ready 9/9/2024 9/9/2024 09/09/2024
Miscellaneous Correction
Corrective Action Required
09/04/2024
See R302.11.1 for approved fire blocking materials -Anchor bolts to be in middle third of plate-TIGHTEN NUTS AT ALL LOCATIONS -Min 2 anchor bolts per plate-by column and at step downs -Use approved materials for ceiling line fireblocking at fur down in garage-NOT CORRECTED -Holes drilled closer than 2” to bottom of joists for electrical throughout garage (have engineer address fix)-ENGINEER CALLED FOR 24” STRAP. CORRECT PER ENGINEERED LETTER WITH ST24 OR EQUIVALENT -Protect pex line at fridge bottom plate-MUST BE PROTECTED 2” ABOVE PLATE LINE -Install (2) 2x4s and H2.5 under GT locations in garage per plan -nail exterior sheathing at double car bay-NOT DONE -solid block joist space at cantilever above dining room-MISSING IN CLOSET -Properly land and protect electrical and seal plate penetrations by stairs, also, only (2) nm cables are allowed per plate penetration-CABLES ARE NOW TOO SHORT ETC. WHEN REQUIRED THIRD FLOOR JOIST WAS INSTALLED -nail exterior wall corners to plans and code(multiple places)-NOT DONE -missing multiple hangers and bracing on trusses throughout 2nd floor-WEB BRACING IS TO BE LOCATED AT THE MIDPOINT OFVTHE WEB -3 studs required at all exterior corners (see basement)-MISSING STUD AND CORNER NAILING PATTERN LEFT OF DOOR -anchor bolts to be in the middle 1/3 of sill plate in basement-TIGHTEN NUT AT BACK WALL -missing (3) 2x10 SW corner of basement and at stairs-THIS IS SUPPOSED TO LAND ON THE BEAM -missing solid blocking under kitchen island-TO BE 48” OC -address all holes drilled closer than 2” to one another throughout (see 1st floor and basement)-COMPLETE PER ENGINEERED LETTER
Erosion Control Inspection Residential Partial 09/11/2024
Misc
Informational
09/09/2024
In conpliance at time of inspection
All Rough Inspection - Residential Not Ready 9/11/2024 9/11/2024 09/11/2024
Miscellaneous Correction
Corrective Action Required
09/09/2024
-TIGHTEN ANCHOR BOLT BY SINGLE CAR BAY -Use approved materials for ceiling line fireblocking at fur down in garage-SEAL GAPS AND PENETRATIONS -Properly land and protect electrical and seal plate penetrations by stairs, also, only (2) nm cables are allowed per plate penetration-SEAL PENETRATIONS -missing multiple hangers and bracing on trusses throughout 2nd floor-WEB BRACING IS TO BE LOCATED AT THE MIDPOINT OF THE WEB -3 studs required at all exterior corners (see basement)-MISSING STUD AND CORNER NAILING PATTERN LEFT OF DOOR-NAIL 12" OC
Erosion Control Inspection Residential Failed 09/12/2024
Misc
Informational
09/11/2024
9/12/24 Remove loose trash and debris from site
All Rough Inspection - Residential Passed 9/12/2024 9/12/2024 09/12/2024
Miscellaneous Correction
Resolved
09/12/2024
-TIGHTEN ANCHOR BOLT BY SINGLE CAR BAY -Use approved materials for ceiling line fireblocking at fur down in garage-SEAL GAPS AND PENETRATIONS -Properly land and protect electrical and seal plate penetrations by stairs, also, only (2) nm cables are allowed per plate penetration-SEAL PENETRATIONS -missing multiple hangers and bracing on trusses throughout 2nd floor-WEB BRACING IS TO BE LOCATED AT THE MIDPOINT OF THE WEB -3 studs required at all exterior corners (see basement)-MISSING STUD AND CORNER NAILING PATTERN LEFT OF DOOR-NAIL 12" OC
Gas Service Inspection - Residential Not Ready 9/23/2024 9/23/2024 09/23/2024
Misc
Corrective Action Required
09/23/2024
NOT READY, NO GAS PIPING INSTALLED AT THIS TIME
Driveway Inspection Passed 9/19/2024 09/23/2024
Misc
Informational
09/19/2024
9-19-24 BR Driveway is formed up and aggregate is place plus compacted ready for concrete. 9-23-24 BR Driveway is constructed to LS specification.
Driveway Inspection Passed 09/26/2024
Misc
Informational
09/19/2024
9-19-24 BR Driveway is formed up and aggregate is place plus compacted ready for concrete. 09/26/24 JMJ Driveway - passed final inspection.
Erosion Control Inspection Residential Failed 09/27/2024
Misc
Resolved
09/27/2024
9/12/24 Remove loose trash and debris from site
DCM5 ESC INSP DENIED
Corrective Action Required
09/27/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -PROVIDE EROSION CONTROL METHODS AND CLEAN SILT AND DEBRIS FROM STREETS -REMOVE TRASH FROM SITE
Gas Service Inspection - Residential Failed 9/27/2024 9/27/2024 09/27/2024
Misc
Corrective Action Required
09/23/2024
NOT READY, NO GAS PIPING INSTALLED AT THIS TIME 9/27/24 -INSPECTION DENIED. SEE FAILED EROSION CONTROL REPORT
Erosion Control Inspection Residential Failed 09/30/2024
DCM5 ESC INSP DENIED
Resolved
09/30/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -PROVIDE EROSION CONTROL METHODS AND CLEAN SILT AND DEBRIS FROM STREETS -REMOVE TRASH FROM SITE
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
09/30/2024
9/30/24 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Partial 10/2/2024 10/2/2024 10/02/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
10/02/2024
9/30/24 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Informational
10/02/2024
in compliance at time of inspection
Gas Service Inspection - Residential Failed 10/3/2024 10/3/2024 10/03/2024
Misc
Corrective Action Required
09/27/2024
-Bond metallic gas piping to GES -CSST secured in joist space less than 3" to bottom of joists requires 16g striker plate -Seal through floor penetrations
Erosion Control Inspection Residential Partial 10/3/2024 10/3/2024 10/03/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/02/2024
9/30/24 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Informational
10/02/2024
in compliance at time of inspection
Erosion Control Inspection Residential Failed 10/11/2024 10/11/2024 10/11/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/03/2024
10/11/24 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Replace damaged, ineffective erosion control methods at perimeter and post address. Clean silt from street
Misc
Resolved
10/11/2024
Gas Service Inspection - Residential Failed 10/11/2024 10/11/2024 10/11/2024
Misc
Corrective Action Required
10/03/2024
-CSST secured in joist space less than 3" to bottom of joists requires 16g striker plate-EVERYWHERE CSST IS SECURED LESS THAN 3" TO BOTTOM OF JOIST PROTECTION IS REQUIRED -Seal through floor penetrations-NOT DONE
Erosion Control Inspection Residential Failed 10/23/2024 10/23/2024 10/23/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
10/23/2024
10/11/24 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Replace damaged, ineffective erosion control methods at perimeter and post address. Clean silt from street
Misc
Corrective Action Required
10/23/2024
Post address
Gas Service Inspection - Residential Passed 10/23/2024 10/23/2024 10/23/2024
Misc
Informational
10/23/2024
-CSST secured in joist space less than 3" to bottom of joists requires 16g striker plate-EVERYWHERE CSST IS SECURED LESS THAN 3" TO BOTTOM OF JOIST PROTECTION IS REQUIRED **Item moved to occupancy inspection notes
Erosion Control Inspection Residential Failed 11/15/2024 11/15/2024 11/15/2024
Misc
Corrective Action Required
10/23/2024
Post address
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
11/15/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -Post address -Maintain erosion control at perimeter
Occupancy Inspection - Codes Residential Not Ready 11/15/2024 11/15/2024 11/15/2024
Misc
Corrective Action Required
10/23/2024
10/23/24 Note from Gas service inspection: -CSST secured in joist space less than 3" to bottom of joists requires 16g striker plate-EVERYWHERE CSST IS SECURED LESS THAN 3" TO BOTTOM OF JOIST PROTECTION IS REQUIRED
Miscellaneous Correction
Corrective Action Required
11/15/2024
11/15/24 *No address. Not ready. No inspection performed -Pay all fees due before occupancy
Erosion Control Inspection Residential Failed 11/18/2024 11/18/2024 11/18/2024
Misc
Resolved
11/18/2024
Post address
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
11/15/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -Maintain erosion control at perimeter
Occupancy Inspection - Codes Residential Failed 11/18/2024 11/18/2024 11/18/2024
Misc
Corrective Action Required
11/15/2024
-Complete final grade, sod, splash blocks etc. -*Exterior not inspected due to conditions -Provide hammer arrestor at dishwasher -Provide lockouts for range, oven and hood -Install missing door hardware -Install all cover plates -Provide guard rails at front where more than 30" to grade -Provide GFCI protection at master bath wc compartment -Provide hammer arrestors at laundry -Install security screws at man doors per LS ch 7 -Deck not inspected
Miscellaneous Correction
Resolved
11/18/2024
11/15/24 *No address. Not ready. No inspection performed -Pay all fees due before occupancy
Occupancy Inspection - Codes Residential Ready for Temp CO 11/20/2024 11/20/2024 11/20/2024
Misc
Corrective Action Required
11/18/2024
-Complete final grade, sod, splash blocks etc. -Water meter to be 14" - 18" to top of riser -Remove mud from water meter pit
Erosion Control Inspection Residential Passed 12/20/2024 12/20/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
12/20/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -Maintain erosion control at perimeter
Plot Plan Inspection Passed 12/20/2024 12/20/2024
Occupancy Inspection - Codes Residential Full C of O 12/20/2024 12/20/2024
Misc
Resolved
12/20/2024
-Complete final grade, sod, splash blocks etc. -Water meter to be 14" - 18" to top of riser -Remove mud from water meter pit
Documents & Images
Date Uploaded File Type Document Name
03/07/2024 WO #175 - ENGINEERED PLANS
03/07/2024 WO #175 - PERMIT APP
03/07/2024 WO #175 - PLOT PLAN
03/07/2024 WO #175 - TRUSS DETAILS
03/07/2024 WO #175 - TRUSS LAYOUT
03/14/2024 Plot Plan APPROVED PLOT PLAN
03/14/2024 Permit Codes Residential Plan Review
03/15/2024 RESPONSE LETTER
03/15/2024 WO #175 - Charleston 240315
03/18/2024 Approved Plans APPROVED PLANS
03/18/2024 Approved Plans APPROVED TRUSS PACKAGE
03/18/2024 Permit Codes Residential Plan Review
03/19/2024 Permit DS Building Permit
03/19/2024 Receipt Receipt for transaction:2024-001717
03/19/2024 WO #175 - TRUSS LAYOUT 3_19_2024
03/19/2024 Approved Plans APPROVED TRUSS LAYOUT
04/12/2024 WO #175 - Charleston 240411
04/12/2024 Approved Plans 4-12-24 APPROVED PLANS
05/02/2024 3RD Party Insp Report - FTG-Signed
05/03/2024 Letter INSPECTION SUMMARY
06/11/2024 Letter INSPECTION SUMMARY
06/12/2024 Letter INSPECTION SUMMARY
06/12/2024 Letter INSPECTION SUMMARY
06/13/2024 Letter INSPECTION SUMMARY
06/17/2024 Letter INSPECTION SUMMARY
06/19/2024 Letter INSPECTION SUMMARY
06/19/2024 Letter INSPECTION SUMMARY
06/20/2024 Letter INSPECTION SUMMARY
07/19/2024 Letter INSPECTION SUMMARY
07/19/2024 Letter INSPECTION SUMMARY
07/24/2024 Letter INSPECTION SUMMARY
07/24/2024 Letter INSPECTION SUMMARY
08/01/2024 Letter INSPECTION SUMMARY
08/01/2024 Letter INSPECTION SUMMARY
08/21/2024 Letter INSPECTION SUMMARY
08/21/2024 Letter INSPECTION SUMMARY
08/22/2024 Letter INSPECTION SUMMARY
08/22/2024 Letter INSPECTION SUMMARY
08/22/2024 Letter INSPECTION SUMMARY
08/28/2024 Letter INSPECTION SUMMARY
08/28/2024 Letter INSPECTION SUMMARY
09/03/2024 175 Woodside Ridge - Deck Piers- Signed
09/04/2024 Letter INSPECTION SUMMARY
09/04/2024 Letter INSPECTION SUMMARY
09/06/2024 Engineer Report/Study ENGINEER REPAIR REPORT
09/09/2024 Letter INSPECTION SUMMARY
09/09/2024 Letter INSPECTION SUMMARY
09/11/2024 Letter INSPECTION SUMMARY
09/11/2024 Letter INSPECTION SUMMARY
09/11/2024 Receipt Receipt for transaction:2024-007624
09/12/2024 Letter INSPECTION SUMMARY
09/12/2024 Letter INSPECTION SUMMARY
09/19/2024 Letter INSPECTION SUMMARY
09/23/2024 Letter INSPECTION SUMMARY
09/23/2024 Letter INSPECTION SUMMARY
09/26/2024 Letter INSPECTION SUMMARY
09/26/2024 Letter INSPECTION SUMMARY
09/27/2024 Letter INSPECTION SUMMARY
09/27/2024 Letter INSPECTION SUMMARY
09/30/2024 Letter INSPECTION SUMMARY
10/02/2024 Letter INSPECTION SUMMARY
10/02/2024 Letter INSPECTION SUMMARY
10/03/2024 Letter INSPECTION SUMMARY
10/03/2024 Letter INSPECTION SUMMARY
10/11/2024 Letter INSPECTION SUMMARY
10/11/2024 Letter INSPECTION SUMMARY
10/23/2024 Letter INSPECTION SUMMARY
10/23/2024 Letter INSPECTION SUMMARY
11/15/2024 Letter INSPECTION SUMMARY
11/15/2024 Letter INSPECTION SUMMARY
11/15/2024 Receipt Receipt for transaction:2024-008986
11/18/2024 Letter INSPECTION SUMMARY
11/18/2024 Letter INSPECTION SUMMARY
11/20/2024 Letter INSPECTION SUMMARY
11/20/2024 Certificate/License Codes Temporary Certificate of Occupancy
11/20/2024 Receipt Receipt for transaction:2024-009061
12/20/2024 Letter INSPECTION SUMMARY
12/20/2024 Letter INSPECTION SUMMARY
12/20/2024 Letter Codes Final Certificate of Occupancy
12/20/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home