Summary
PRRES20241065
Building Permit - Residential
Certificate of Occupancy
NEW DUPLEX
NEW DUPLEX - ROOF TRUSSES - UNFINISHED BASEMENT STOP WORK ORDER generated on 04/22/2024 12:00 AM by username 'Kyle Beard'. STOP WORK ORDER removed on 04/24/2024 12:00 AM by username 'Kyle Beard'.
03/07/2024
03/13/2024
10/17/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Duplex $2,914.95 $2,914.95 Paid 03/13/2024
Sanitary Sewer Development Fee $4,318.00 $4,318.00 Paid 03/13/2024
Right of Way Permit Fee $85.00 $85.00 Paid 03/13/2024
Residential Excise Tax Fee $1,240.32 $1,240.32 Paid 03/13/2024
Water Tap Fee $7,520.00 $7,520.00 Paid 03/13/2024
Water Meter Fee $1,360.92 $1,360.92 Paid 03/13/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 09/23/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 09/23/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 09/23/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 09/25/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 09/25/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 3/29/2024 03/29/2024
Miscellaneous Correction
Corrective Action Required
03/29/2024
-Footing was passed by a third party. -Third party passed erosion control. -On my on site footing inspection, the North side of the property has no erosion control installed - footing inspection will not be passed until full erosion control measures are in place
Erosion Control Inspection Residential Failed 3/29/2024 03/29/2024
Miscellaneous Correction
Corrective Action Required
03/29/2024
Erosion control measures are missing along the North side of property. Full erosion control measures must be implemented and maintained until CofO
Sewer Service Inspection - R Passed 4/15/2024 4/15/2024 04/15/2024
Water Service Inspection - R Partial 4/15/2024 04/15/2024
Miscellaneous Correction
Informational
04/15/2024
PEX has been run out from the foundation about 25 feet. Okay to cover PEX line only. This is a partial pass only. Meter base, copper and connections will be installed at a later date.
Erosion Control Inspection Residential Partial 4/17/2024 04/17/2024
Miscellaneous Correction
Resolved
04/17/2024
Erosion control measures are missing along the North side of property. Full erosion control measures must be implemented and maintained until CofO
Miscellaneous Correction
Informational
04/17/2024
Erosion control is in place and must be maintained until CofO
Underslab Plumbing Inspection - Residential Failed 4/17/2024 4/17/2024 04/17/2024
Miscellaneous Correction
Corrective Action Required
04/17/2024
Underslab plumbing Underslab plumbing will not pass until all wood from forms which includes stakes are removed from contact of the ground. R317.1.2 ground contact
Water Service Inspection - R Failed 4/19/2024 04/19/2024
Miscellaneous Correction
Resolved
04/19/2024
PEX has been run out from the foundation about 25 feet. Okay to cover PEX line only. This is a partial pass only. Meter base, copper and connections will be installed at a later date.
Miscellaneous Correction
Corrective Action Required
04/19/2024
Water passed and is okay to cover Address numbers are not posted on location. No inspections will be completed until proper identification is posted
Underslab Plumbing Inspection - Residential Failed - Stop Work 4/22/2024 4/22/2024 04/22/2024
Miscellaneous Correction
Corrective Action Required
04/17/2024
Underslab plumbing Underslab plumbing will not pass until all wood from forms which includes stakes are removed from contact of the ground. R317.1.2 ground contact
Miscellaneous Correction
Corrective Action Required
04/22/2024
Underslab plumbing - Underslab plumbing will not pass until all wood from forms which includes stakes are removed from contact of the ground. R317.1.2 ground contact - Footing inspection has not passed - gravel needs to be installed between the street and foundation STOP WORK ORDER is issued on this property until all items are addressed and passed
Erosion Control Inspection Residential Partial 4/24/2024 04/24/2024
Miscellaneous Correction
Informational
04/17/2024
Erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Informational
04/24/2024
Full erosion control is in place and must be maintained until CofO
Underslab Plumbing Inspection - Residential Passed 4/24/2024 4/24/2024 04/24/2024
Miscellaneous Correction
Resolved
04/24/2024
Underslab plumbing Underslab plumbing will not pass until all wood from forms which includes stakes are removed from contact of the ground. R317.1.2 ground contact
Miscellaneous Correction
Resolved
04/24/2024
Underslab plumbing - Underslab plumbing will not pass until all wood from forms which includes stakes are removed from contact of the ground. R317.1.2 ground contact - Footing inspection has not passed - gravel needs to be installed between the street and foundation STOP WORK ORDER is issued on this property until all items are addressed and passed
Footing Inspection - Residential Passed 4/24/2024 04/24/2024
Miscellaneous Correction
Resolved
04/24/2024
-Footing was passed by a third party. -Third party passed erosion control. -On my on site footing inspection, the North side of the property has no erosion control installed - footing inspection will not be passed until full erosion control measures are in place
Miscellaneous Inspection Passed 5/1/2024 05/01/2024
Miscellaneous Correction
Informational
05/01/2024
Slab on grade inspection was done and passed by a third party
All Rough Inspection - Residential Partial 5/28/2024 5/28/2024 05/28/2024
Misc
Informational
05/28/2024
Garage portal walls inspection only-OK to cover
Electrical Service Inspection Passed 7/9/2024 7/9/2024 07/09/2024
Gas Service Inspection - Residential Failed 7/9/2024 7/9/2024 07/09/2024
Miscellaneous Correction
Corrective Action Required
07/09/2024
Gas on both units failed because of gauge reading 0 psi at the beginning of the inspection
Water Service Inspection - R Passed 7/9/2024 07/09/2024
Miscellaneous Correction
Resolved
07/09/2024
Water passed and is okay to cover Address numbers are not posted on location. No inspections will be completed until proper identification is posted
Erosion Control Inspection Residential Failed 7/9/2024 07/09/2024
Miscellaneous Correction
Resolved
07/09/2024
Erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Resolved
07/09/2024
Full erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
07/09/2024
Erosion control measures are missing at the front of the property Full erosion control must be maintained until CofO
Rated Assembly Inspection Passed 7/9/2024 7/9/2024 07/09/2024
All Rough Inspection - Residential Failed 7/9/2024 7/9/2024 07/09/2024
Misc
Resolved
07/09/2024
Garage portal walls inspection only-OK to cover
Miscellaneous Correction
Corrective Action Required
07/09/2024
3728 and 3730 SW Knoxville. All rough 3728 Block over garage header Install LIB’ s to plan Fire block top of chase in garage to powder bathroom Nail is missing in joist hanger above kitchen island One stud in the 3 stud pack at the stairwell is not continuous Truss brackets are missing in the front entry Nail front entry corner to code Nail dining room corner to code Fire block hole in floor at the air supply line in the living room Roof boot jacks are not installed Lateral track attic trusses Truss brackets are missing in bedroom 1 One stud in the three pack is missing in bedroom 1 H2.5a brackets are missing in bedroom 1 Nail bedroom 1 S/E corner to code Fire block top plate in toilet of bathroom 1 One 2x10 in header above basement window is not installed Support 12/2 wire at demising wall in basement I beam in basement has shims but are not fully supporting the Ibeam Address over notched 2x10 floor joist at 3 inch waste line in basement Gas gauge is at 0psi upon inspection 3730 Fire block above garage header Fire block top of chase in garage to powder bathroom Nails missing in LIB in dining room Nail great room outside corner to code Renail joist hanger above great room in Ibeam Nail missing in joist above kitchen island Truss tie down screws are not installed in the entry Truss joist hangers in entry are missing nails Nail front entry corner to code LIB in bedroom two has sheet rock screws used as fasteners Outside corner in bedroom 2 is not fastened correctly Nail outside corner of bedroom three to code Roof boot jacks are not installed Gas gauge is at 0 psi upon inspection Basement window header is missing the third 2x10 Support 12/2 wire in basement along the demising wall Have full erosion control in place before scheduling any more inspections
Gas Service Inspection - Residential Passed 7/16/2024 7/16/2024 07/16/2024
Miscellaneous Correction
Resolved
07/16/2024
Gas on both units failed because of gauge reading 0 psi at the beginning of the inspection
Erosion Control Inspection Residential Partial 7/16/2024 07/16/2024
Miscellaneous Correction
Resolved
07/16/2024
Erosion control measures are missing at the front of the property Full erosion control must be maintained until CofO
Miscellaneous Correction
Informational
07/16/2024
Full erosion control measures are in place and must be maintained until CofO
All Rough Inspection - Residential Failed 7/16/2024 7/16/2024 07/16/2024
Miscellaneous Correction
Resolved
07/16/2024
3728 and 3730 SW Knoxville. All rough 3728 Block over garage header Install LIB’ s to plan Fire block top of chase in garage to powder bathroom Nail is missing in joist hanger above kitchen island One stud in the 3 stud pack at the stairwell is not continuous Truss brackets are missing in the front entry Nail front entry corner to code Nail dining room corner to code Fire block hole in floor at the air supply line in the living room Roof boot jacks are not installed Lateral track attic trusses Truss brackets are missing in bedroom 1 One stud in the three pack is missing in bedroom 1 H2.5a brackets are missing in bedroom 1 Nail bedroom 1 S/E corner to code Fire block top plate in toilet of bathroom 1 One 2x10 in header above basement window is not installed Support 12/2 wire at demising wall in basement I beam in basement has shims but are not fully supporting the Ibeam Address over notched 2x10 floor joist at 3 inch waste line in basement Gas gauge is at 0psi upon inspection 3730 Fire block above garage header Fire block top of chase in garage to powder bathroom Nails missing in LIB in dining room Nail great room outside corner to code Renail joist hanger above great room in Ibeam Nail missing in joist above kitchen island Truss tie down screws are not installed in the entry Truss joist hangers in entry are missing nails Nail front entry corner to code LIB in bedroom two has sheet rock screws used as fasteners Outside corner in bedroom 2 is not fastened correctly Nail outside corner of bedroom three to code Roof boot jacks are not installed Gas gauge is at 0 psi upon inspection Basement window header is missing the third 2x10 Support 12/2 wire in basement along the demising wall Have full erosion control in place before scheduling any more inspections
Miscellaneous Correction
Corrective Action Required
07/16/2024
3728 and 3730 SW Knoxville. All rough (2) 3728 -One 2x10 in header above basement window is not installed (joist hanger is missing) -Address over notched 2x10 floor joist at 3 inch waste line in basement -Under general plan notes #15, tubs shall have double joist under them for support -Trusses in bedroom 1 are more than 1 inch away from the girder truss. Have engineer address if joist hangers installed are capable of handling the load 3730 -Under general plan notes #15, tubs shall have double joist under them for support -Basement window header is missing the third 2x10 (joist hangers are not installed
All Rough Inspection - Residential Passed 7/22/2024 7/22/2024 07/22/2024
Miscellaneous Correction
Resolved
07/22/2024
3728 and 3730 SW Knoxville. All rough (2) 3728 -One 2x10 in header above basement window is not installed (joist hanger is missing) -Address over notched 2x10 floor joist at 3 inch waste line in basement -Under general plan notes #15, tubs shall have double joist under them for support -Trusses in bedroom 1 are more than 1 inch away from the girder truss. Have engineer address if joist hangers installed are capable of handling the load 3730 -Under general plan notes #15, tubs shall have double joist under them for support -Basement window header is missing the third 2x10 (joist hangers are not installed
Driveway Inspection Partial 7/29/2024 07/29/2024
Misc
Informational
07/29/2024
7-29-24 PS Driveway approach pre pour, forms in place and aggregate compacted, approved to pour
Sidewalk Inspection Partial 7/29/2024 07/29/2024
Misc
Informational
07/29/2024
7-29-24 PS Sidewalk pre pour, forms in place and aggregate compacted, approved to pour
Rated Assembly Inspection Not Ready 7/30/2024 07/30/2024
Misc
Corrective Action Required
07/30/2024
Inspection denied no address posted
Rated Assembly Inspection Passed 7/31/2024 7/31/2024 07/31/2024
Misc
Resolved
07/31/2024
Driveway Inspection Passed 8/5/2024 8/5/2024 08/05/2024
Misc
Informational
07/29/2024
7-29-24 PS Driveway approach pre pour, forms in place and aggregate compacted, approved to pour 8-5-24 PS Driveway approach meets ADA and LS specs
Sidewalk Inspection Passed 8/5/2024 8/5/2024 08/05/2024
Misc
Informational
07/29/2024
7-29-24 PS Sidewalk pre pour, forms in place and aggregate compacted, approved to pour 8-5-24 PS Sidewalk meets LS and ADA specs
Occupancy Inspection - Codes Residential Not Ready 9/18/2024 9/18/2024 09/18/2024
Miscellaneous Correction
Corrective Action Required
09/18/2024
3728 & 3730 SW Knoxville. Occupancy 3730 First riser up from the main floor going upstairs is over the code allowance 7 3/4 inches high Handrail going upstairs does not meet at the nosing of the last step to the main floor Patio door does not have a secondary lock installed Backsplash spark ring needs to extend out and cover the gap between the tile and sheet rock Fire block all gaps in sheet rock in garage Last riser coming up from the basement is over the code allowance 7 3/4 inches in height Basement handrail does not return to the wall One electrical outlet by the basement HWT is not GFCI protected Fire block hole in floor above in basement for double 12/3 wire at kitchen island Garage to house self closing hinge at door is not working correctly Remove smoke detector dust covers up stairs 3728 first riser up from main floor to upstairs is not to code No secondary lock installed on patio door Basement handrail is not installed Not Ready for inspection This is not a complete list Walk your property before scheduling any inspection
Occupancy Inspection - Codes Residential Failed 9/20/2024 9/20/2024 09/20/2024
Miscellaneous Correction
Resolved
09/20/2024
3728 & 3730 SW Knoxville. Occupancy 3730 First riser up from the main floor going upstairs is over the code allowance 7 3/4 inches high Handrail going upstairs does not meet at the nosing of the last step to the main floor Patio door does not have a secondary lock installed Backsplash spark ring needs to extend out and cover the gap between the tile and sheet rock Fire block all gaps in sheet rock in garage Last riser coming up from the basement is over the code allowance 7 3/4 inches in height Basement handrail does not return to the wall One electrical outlet by the basement HWT is not GFCI protected Fire block hole in floor above in basement for double 12/3 wire at kitchen island Garage to house self closing hinge at door is not working correctly Remove smoke detector dust covers up stairs 3728 first riser up from main floor to upstairs is not to code No secondary lock installed on patio door Basement handrail is not installed Not Ready for inspection This is not a complete list Walk your property before scheduling any inspection
Miscellaneous Correction
Corrective Action Required
09/20/2024
3728 & 3730 SW Knoxville. Occupancy (2) 3730 First riser up from the main floor going upstairs is over the code allowance 7 3/4 inches high Handrail going upstairs does not meet at the nosing of the last step to the main floor (now does not fully return back to the wall) 3728 first riser up from main floor to upstairs is not to code (over the code allowed 7 3/4 inches) Exterior of both units Sod and splash pads are not installed Penetrations at gas line to siding needs to be sealed 3730 top hat of water meters in misaligned Pay $150 fee associated with this permit
Occupancy Inspection - Codes Residential Not Ready 9/23/2024 9/23/2024 09/23/2024
Miscellaneous Correction
Resolved
09/23/2024
3728 & 3730 SW Knoxville. Occupancy (2) 3730 First riser up from the main floor going upstairs is over the code allowance 7 3/4 inches high Handrail going upstairs does not meet at the nosing of the last step to the main floor (now does not fully return back to the wall) 3728 first riser up from main floor to upstairs is not to code (over the code allowed 7 3/4 inches) Exterior of both units Sod and splash pads are not installed Penetrations at gas line to siding needs to be sealed 3730 top hat of water meters in misaligned Pay $150 fee associated with this permit
Miscellaneous Correction
Corrective Action Required
09/23/2024
3728 & 3730 SW Knoxville. Occupancy (3) 3730 First riser up from the main floor going upstairs is over the code allowance 7 3/4 inches high Handrail going upstairs does not meet at the nosing of the last step to the main floor (now does not fully return back to the wall) 3728 first riser up from main floor to upstairs is not to code (over the code allowed 7 3/4 inches) Exterior of both units Sod and splash pads are not installed Penetrations at gas line to siding needs to be sealed 3730 top hat of water meters in misaligned Remove mud from sidewalk and driveway No improvements were made before rescheduling another inspection. Not ready Pay $225 fee associated with this permit
Occupancy Inspection - Codes Residential Not Ready 9/24/2024 9/24/2024 09/24/2024
Miscellaneous Correction
Corrective Action Required
09/23/2024
3728 & 3730 SW Knoxville. Occupancy (4) 3730 First riser up from the main floor going upstairs is over the code allowance 7 3/4 inches high 3728 first riser up from main floor to upstairs is not to code (over the code allowed 7 3/4 inches) Exterior of both units Sod and splash pads are not installed Penetrations at gas line to siding needs to be sealed 3730 top hat of water meters in misaligned Remove mud from sidewalk and driveway Not all improvements were made before rescheduling inspection againNot ready 09/24/24. KBEARD time 8:50am
Erosion Control Inspection Residential Partial 9/25/2024 09/25/2024
Miscellaneous Correction
Informational
07/16/2024
Full erosion control measures are in place and must be maintained until CofO
Plot Plan Inspection Failed 9/25/2024 09/25/2024
Miscellaneous Correction
Corrective Action Required
09/25/2024
A retaining wall has been built along the properties west side and is not in the original plot plan approved by the city. Update plot plan with an as built and submit to the city for approval
Occupancy Inspection - Codes Residential Ready for Temp CO 9/25/2024 9/25/2024 09/25/2024
Miscellaneous Correction
Resolved
09/25/2024
3728 & 3730 SW Knoxville. Occupancy (4) 3730 First riser up from the main floor going upstairs is over the code allowance 7 3/4 inches high 3728 first riser up from main floor to upstairs is not to code (over the code allowed 7 3/4 inches) Exterior of both units Sod and splash pads are not installed Penetrations at gas line to siding needs to be sealed 3730 top hat of water meters in misaligned Remove mud from sidewalk and driveway Not all improvements were made before rescheduling inspection againNot ready 09/24/24. KBEARD time 8:50am
Miscellaneous Correction
Corrective Action Required
09/25/2024
3728 & 3730 SW Knoxville. Exterior of both units Sod and splash pads are not installed Penetrations at gas line to siding needs to be sealed Install sump pump extensions As built plot plan must be resubmitted because of a retaining wall that was built along the properties west side Pay $75 fee associated with this permit Both units passed for TCO only
Erosion Control Inspection Residential Passed 10/16/2024 10/16/2024
Miscellaneous Correction
Resolved
10/16/2024
Full erosion control measures are in place and must be maintained until CofO
Plot Plan Inspection Passed 10/17/2024 10/17/2024
Miscellaneous Correction
Corrective Action Required
09/25/2024
A retaining wall has been built along the properties west side and is not in the original plot plan approved by the city. Update plot plan with an as built and submit to the city for approval
Occupancy Inspection - Codes Residential Full C of O 10/16/2024 10/17/2024 10/17/2024
Miscellaneous Correction
Resolved
10/17/2024
3728 & 3730 SW Knoxville. Exterior of both units Sod and splash pads are not installed Penetrations at gas line to siding needs to be sealed Install sump pump extensions As built plot plan must be resubmitted because of a retaining wall that was built along the properties west side Pay $75 fee associated with this permit Both units passed for TCO only
Documents & Images
Date Uploaded File Type Document Name
03/07/2024 OS #81 - Permit App
03/12/2024 Approved Plans APPROVED PLANS
03/12/2024 Plot Plan approved plot plan
03/12/2024 Approved Plans APPROVED TRUSS LAYOUT
03/12/2024 Approved Plans APPROVED TRUSS PACKAGE
03/13/2024 Permit Codes Residential Plan Review
03/13/2024 Permit DS Building Permit
03/13/2024 Receipt Receipt for transaction:2024-001567
03/29/2024 3RD Party Insp Report M L Crose 3728 & 3730 SW Knoxville Ct LSMO Osage Lot 81 Clayton P 2024-1065 3rd Party Footing Inspection Report 3-28-24
03/29/2024 Letter INSPECTION SUMMARY
03/29/2024 Letter INSPECTION SUMMARY
04/15/2024 Letter INSPECTION SUMMARY
04/15/2024 Letter INSPECTION SUMMARY
04/15/2024 Letter INSPECTION SUMMARY
04/17/2024 Letter INSPECTION SUMMARY
04/17/2024 Letter INSPECTION SUMMARY
04/19/2024 Letter INSPECTION SUMMARY
04/22/2024 Letter Stop Work Order
04/24/2024 Letter INSPECTION SUMMARY
04/24/2024 Letter INSPECTION SUMMARY
04/24/2024 Letter INSPECTION SUMMARY
04/30/2024 Final_2024_04_29_GBSlab_LSMO_Pat Cochran Concrete
05/01/2024 Letter INSPECTION SUMMARY
05/28/2024 Letter INSPECTION SUMMARY
07/09/2024 Letter INSPECTION SUMMARY
07/09/2024 Letter INSPECTION SUMMARY
07/09/2024 Letter INSPECTION SUMMARY
07/09/2024 Letter INSPECTION SUMMARY
07/09/2024 Letter INSPECTION SUMMARY
07/09/2024 Letter INSPECTION SUMMARY
07/16/2024 Engineer Report/Study ENGINEER FRAMING LETTER
07/16/2024 Letter INSPECTION SUMMARY
07/16/2024 Letter INSPECTION SUMMARY
07/16/2024 Letter INSPECTION SUMMARY
07/22/2024 SUMMIT - FJ UNDER TUB - 240719
07/22/2024 Letter INSPECTION SUMMARY
07/29/2024 Letter INSPECTION SUMMARY
07/29/2024 Letter INSPECTION SUMMARY
07/30/2024 Letter INSPECTION SUMMARY
07/31/2024 Letter INSPECTION SUMMARY
08/05/2024 Letter INSPECTION SUMMARY
08/05/2024 Letter INSPECTION SUMMARY
09/18/2024 Letter INSPECTION SUMMARY
09/20/2024 Letter INSPECTION SUMMARY
09/23/2024 Letter INSPECTION SUMMARY
09/23/2024 Receipt Receipt for transaction:2024-007835
09/24/2024 Letter INSPECTION SUMMARY
09/25/2024 Letter INSPECTION SUMMARY
09/25/2024 Letter INSPECTION SUMMARY
09/25/2024 Letter INSPECTION SUMMARY
09/25/2024 Certificate/License Codes Temporary Certificate of Occupancy
09/25/2024 Receipt Receipt for transaction:2024-007904
10/16/2024 Letter INSPECTION SUMMARY
10/16/2024 OS 81 Updated Plot Plan
10/17/2024 Letter INSPECTION SUMMARY
10/17/2024 Letter Field Certificate of Occupancy
10/17/2024 Letter Codes Final Certificate of Occupancy
10/28/2024 LOT 81 FINAL 10-28-24
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.