Summary
PRRES20240550
Building Permit - Residential
Certificate of Occupancy
NEW DUPLEX
NEW DUPLEX - UNFINISHED BASEMENT - ROOF TRUSSES -
02/08/2024
02/14/2024
08/11/2024
10/09/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Duplex $2,898.95 $2,898.95 Paid 02/14/2024
Right of Way Permit Fee $85.00 $85.00 Paid 02/14/2024
Residential Excise Tax Fee $1,240.32 $1,240.32 Paid 02/14/2024
Sanitary Sewer Development Fee $4,318.00 $4,318.00 Paid 02/14/2024
Water Tap Fee $7,520.00 $7,520.00 Paid 02/14/2024
Water Meter Fee $1,360.92 $1,360.92 Paid 02/14/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 07/12/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 07/12/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 07/12/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 07/18/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 08/23/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 09/30/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/12/2024 03/12/2024
Miscellaneous Correction
Informational
03/12/2024
Footing field verified and passed by a third party. No mention of piers were in the footing report
Sewer Service Inspection - R Failed 3/18/2024 3/18/2024 03/18/2024
Miscellaneous Correction
Corrective Action Required
03/18/2024
Sewer on both sides passed and ok to cover Erosion control is not in place so sewer failed until full erosion control measures are implemented
Erosion Control Inspection Residential Failed 3/18/2024 03/18/2024
Miscellaneous Correction
Corrective Action Required
03/18/2024
Erosion control is not in place at the time of sewer inspection. Full erosion control must be in place and maintained until full CofO
Water Service Inspection - R Passed 3/18/2024 03/18/2024
Underslab Plumbing Inspection - Residential Passed 3/26/2024 3/26/2024 03/26/2024
Erosion Control Inspection Residential Failed 4/5/2024 04/05/2024
Miscellaneous Correction
Corrective Action Required
03/18/2024
Erosion control is not in place at the time of server inspection. Full erosion control must be in place and maintained until full CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/05/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Install full erosion control at the street and sweep the street clean of gravel before a stop work order is issued 04/05/24. KBEARD
Erosion Control Inspection Residential Partial 4/11/2024 04/09/2024
Miscellaneous Correction
Resolved
04/09/2024
Erosion control is not in place at the time of server inspection. Full erosion control must be in place and maintained until full CofO
DCM3 ESC REQUIRED 2 DAY
Resolved
04/09/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Install full erosion control at the street and sweep the street clean of gravel before a stop work order is issued 04/05/24. KBEARD
Miscellaneous Correction
Informational
04/09/2024
Full erosion control is in place and needs to be maintained until CofO
All Rough Inspection - Residential Partial 4/24/2024 4/24/2024 04/24/2024
Misc
Informational
04/24/2024
Garage portal frame inspection performed both sides
Rated Assembly Inspection Failed 5/13/2024 5/13/2024 05/13/2024
Miscellaneous Correction
Corrective Action Required
05/13/2024
3738 SW Knoxville. Rated assembly vertical fire block main level rated wall every 10 feet or less on center Seal large gap at ridge to fire wall in the common gable roof 3736 vertical fire block main level rated wall every 10 feet or less on center
Gas Service Inspection - Residential Failed 5/13/2024 5/13/2024 05/13/2024
Miscellaneous Correction
Corrective Action Required
05/13/2024
Gas gauge is not working in unit 3736
Electrical Service Inspection Passed 5/13/2024 5/13/2024 05/13/2024
Erosion Control Inspection Residential Failed 5/13/2024 05/13/2024
Miscellaneous Correction
Resolved
05/13/2024
Full erosion control is in place and needs to be maintained until CofO
Miscellaneous Correction
Corrective Action Required
05/13/2024
Gravel needs to be reapplied from the street to the foundation. All other erosion control is in place and needs to be maintained until CofO
Sewer Service Inspection - R Passed 5/13/2024 05/13/2024
Miscellaneous Correction
Resolved
05/13/2024
Sewer on both sides passed and ok to cover Erosion control is not in place so sewer failed until full erosion control measures are implemented
All Rough Inspection - Residential Failed 5/13/2024 5/13/2024 05/13/2024
Misc
Resolved
05/13/2024
Garage portal frame inspection performed both sides
Miscellaneous Correction
Corrective Action Required
05/13/2024
3736 SW Knoxville. All rough 1 2x4 studs is missing at the garage to house door entry Fire block top of chase in between the pantry and dining room Add stud at patio door Two joist hangers are missing nails in joist above dining and living room All mechanical needs to be protected with BOCA plates that go 2 inches below and 2 inches above the the top and sole plate Attic access in utility room needs 30 inches of head clearance Nail top of stairwell corner to code Gas gauge on system does not work Some Fire blocking missing above basement Ibeam Fire block basement ceiling/floor to powder bathroom at waste line 3734 Fire block to of chase between pantry an dining room All mechanical needs to be protected with 2 inch BOCA that extend 2 inches above and below sole and top plate Fire block powder bathroom floor at toilet flange One joist hanger in the kitchen area is missing nails LSTA is not installed in entry Truss hold down screws are missing in the entry Truss hangers in bedroom 1 is missing nails and one is missing the truss hanger Fire blocking is missing in basement between the sump pump area and the garage
Rated Assembly Inspection Failed 5/17/2024 5/17/2024 05/17/2024
Miscellaneous Correction
Corrective Action Required
05/13/2024
3734 SW Knoxville. Rated assembly Seal large gap at ridge to fire wall in the common gable roof
Gas Service Inspection - Residential Failed 5/17/2024 5/17/2024 05/17/2024
Miscellaneous Correction
Corrective Action Required
05/13/2024
Gas gauge is not working in unit 3736 No gas gauge is present upon inspection
All Rough Inspection - Residential Failed 5/17/2024 5/17/2024 05/17/2024
Miscellaneous Correction
Resolved
05/17/2024
3736 SW Knoxville. All rough 1 2x4 studs is missing at the garage to house door entry Fire block top of chase in between the pantry and dining room Add stud at patio door Two joist hangers are missing nails in joist above dining and living room All mechanical needs to be protected with BOCA plates that go 2 inches below and 2 inches above the the top and sole plate Attic access in utility room needs 30 inches of head clearance Nail top of stairwell corner to code Gas gauge on system does not work Some Fire blocking missing above basement Ibeam Fire block basement ceiling/floor to powder bathroom at waste line 3734 Fire block to of chase between pantry an dining room All mechanical needs to be protected with 2 inch BOCA that extend 2 inches above and below sole and top plate Fire block powder bathroom floor at toilet flange One joist hanger in the kitchen area is missing nails LSTA is not installed in entry Truss hold down screws are missing in the entry Truss hangers in bedroom 1 is missing nails and one is missing the truss hanger Fire blocking is missing in basement between the sump pump area and the garage
Miscellaneous Correction
Corrective Action Required
05/17/2024
3736 SW Knoxville. All rough (2) Fire block top of chase in between the pantry and dining room Gas gauge on system does not work Some Fire blocking missing above basement Ibeam 3734 Fire block to of chase between pantry an dining Fire blocking is missing between the sump pump area and the garage Have engineer address two broken vertical truss members at north assembly wall by the ridge
Rated Assembly Inspection Not Ready 5/21/2024 5/21/2024 05/21/2024
Miscellaneous Correction
Resolved
05/21/2024
3734 SW Knoxville. Rated assembly Seal large gap at ridge to fire wall in the common gable roof
Miscellaneous Correction
Corrective Action Required
05/21/2024
3734 SW Knoxville. Rated assembly (2) Seal large gap at ridge to fire wall in the common gable roof (not all gaps were covered and one 2x4 is falling down) Not ready
All Rough Inspection - Residential Not Ready 5/21/2024 5/21/2024 05/21/2024
Miscellaneous Correction
Corrective Action Required
05/17/2024
3736 SW Knoxville. All rough (2) Fire block top of chase in between the pantry and dining room (fill gaps around new ceiling plywood that was installed) Gas gauge is still not installed on the system for inspection 3734 Fire block to of chase between pantry an dining (fill gaps around new ceiling plywood that was installed) Fire blocking is missing between the sump pump area and the garage (fill in gap around waste vent PVC) Not ready for inspection
Gas Service Inspection - Residential Failed 5/21/2024 5/21/2024 05/21/2024
Miscellaneous Correction
Resolved
05/21/2024
Gas gauge is not working in unit 3736 No gas gauge is present upon inspection
Miscellaneous Correction
Corrective Action Required
05/21/2024
Gas gauge is not working in unit 3736. (2) No gas gauge is present upon inspection Gas gauge is still not present for inspection
Rated Assembly Inspection Passed 5/22/2024 5/22/2024 05/22/2024
Miscellaneous Correction
Resolved
05/22/2024
3734 SW Knoxville. Rated assembly (2) Seal large gap at ridge to fire wall in the common gable roof (not all gaps were covered and one 2x4 is falling down) Not ready
All Rough Inspection - Residential Passed 5/22/2024 5/22/2024 05/22/2024
Miscellaneous Correction
Resolved
05/22/2024
3736 SW Knoxville. All rough (2) Fire block top of chase in between the pantry and dining room (fill gaps around new ceiling plywood that was installed) Gas gauge is still not installed on the system for inspection 3734 Fire block to of chase between pantry an dining (fill gaps around new ceiling plywood that was installed) Fire blocking is missing between the sump pump area and the garage (fill in gap around waste vent PVC) Not ready for inspection
Gas Service Inspection - Residential Passed 5/22/2024 5/22/2024 05/22/2024
Miscellaneous Correction
Resolved
05/22/2024
Gas gauge is not working in unit 3736. (2) No gas gauge is present upon inspection Gas gauge is still not present for inspection
Rated Assembly Inspection Passed 5/28/2024 05/28/2024
Driveway Inspection Partial 6/17/2024 06/17/2024
Misc
Informational
06/17/2024
6-17-24 PS Driveway approach pre pour, forms in place and aggregate compacted, approved to pour
Sidewalk Inspection Partial 6/17/2024 06/17/2024
Misc
Informational
06/17/2024
6-17-24 PS Sidewalk pre pour, forms in place and aggregate compacted, approved to pour
Driveway Inspection Passed 6/25/2024 6/25/2024 06/25/2024
Misc
Informational
06/17/2024
6-17-24 PS Driveway approach pre pour, forms in place and aggregate compacted, approved to pour 6-25-24 PS Driveway approach meets LS and ADA specs
Sidewalk Inspection Passed 6/25/2024 6/25/2024 06/25/2024
Misc
Informational
06/17/2024
6-17-24 PS Sidewalk pre pour, forms in place and aggregate compacted, approved to pour 6-25-24 PS Sidewalk meets LS and ADA specs
Erosion Control Inspection Residential Partial 7/12/2024 07/12/2024
Miscellaneous Correction
Resolved
07/12/2024
Gravel needs to be reapplied from the street to the foundation. All other erosion control is in place and needs to be maintained until CofO
Miscellaneous Correction
Informational
07/12/2024
Erosion control measures are in place and must be maintained until CofO
Occupancy Inspection - Codes Residential Not Ready 7/12/2024 7/12/2024 07/12/2024
Miscellaneous Correction
Corrective Action Required
07/12/2024
3734 and 3736 SW Knoxville. Occupancy Address numbers are backwards on both units 3734 Guard rail needs to be installed on the front porch (Northside) First stair riser up from the main floor, has a greater then the code allowed 7 3/4 of an inch Fire block holes in the garage where the walls meet the ceiling Bottom riser in the basement has a riser height of 8 inches Breaker panel is not marked GFCI it’s kitchen backsplash does not work Unit is not ready for inspection. Walk your property before scheduling an inspection Not a complete list 3736 Unit has reoccurring deficiencies as the other unit Unit inspection was not conducted Not a complete list Not ready for inspection
Plot Plan Inspection Failed 7/12/2024 07/12/2024
Miscellaneous Correction
Informational
07/12/2024
Plot plan not ready at the time of occupancy inspection Plot still needs a final grading
Occupancy Inspection - Codes Residential Failed 7/16/2024 7/16/2024 07/16/2024
Miscellaneous Correction
Partial Correction
07/16/2024
3734 -Missing blow off tube on water heater -It appears that TR outlets were not used throughout -Fire blocking at bottom of chase in garage 3736 -It appears that TR outlets were not used throughout -First stair riser to upstairs over 7 3/4” -Patio sliding door lock and secondary not operating correctly -Fire blocking at bottom of chase in garage
Occupancy Inspection - Codes Residential Ready for Temp CO 7/18/2024 7/18/2024 07/18/2024
Miscellaneous Correction
Resolved
07/18/2024
3734 -Missing blow off tube on water heater -It appears that TR outlets were not used throughout -Fire blocking at bottom of chase in garage 3736 -It appears that TR outlets were not used throughout -First stair riser to upstairs over 7 3/4” -Patio sliding door lock and secondary not operating correctly -Fire blocking at bottom of chase in garage
Miscellaneous Correction
Corrective Action Required
07/18/2024
- Seal exterior penetrations - Sod, sump pump extensions and splash blocks are not installed - Plot plan not ready
Erosion Control Inspection Residential Partial 7/18/2024 07/18/2024
Miscellaneous Correction
Resolved
07/18/2024
Erosion control measures are in place and must be maintained until CofO
Miscellaneous Correction
Informational
07/18/2024
Erosion control measures are in place and must be maintained until CofO
Erosion Control Inspection Residential Failed 8/13/2024 08/13/2024
Miscellaneous Correction
Resolved
08/13/2024
Erosion control measures are in place and must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
08/13/2024
Erosion control needs to added to the North side of the property for protection of water run off. Full erosion control measures must be maintained until CofO
Occupancy Inspection - Codes Residential Ready for Temp CO 8/23/2024 08/23/2024
Miscellaneous Correction
Corrective Action Required
07/18/2024
- Seal exterior penetrations - Sod, sump pump extensions and splash blocks are not installed - Plot plan not ready Builder sent in a TCO extension form. This is the first extension request and builder is actively working on the exterior of the property.
Plot Plan Inspection Passed 9/5/2024 09/05/2024
Miscellaneous Correction
Resolved
09/05/2024
Plot plan not ready at the time of occupancy inspection Plot still needs a final grading
Erosion Control Inspection Residential Partial 9/5/2024 09/05/2024
Miscellaneous Correction
Resolved
09/05/2024
Erosion control needs to added to the North side of the property for protection of water run off. Full erosion control measures must be maintained until CofO
Miscellaneous Correction
Informational
09/05/2024
Full erosion control measures must be in place and maintained until CofO
Occupancy Inspection - Codes Residential Ready for Temp CO 9/30/2024 09/30/2024
Miscellaneous Correction
Resolved
09/30/2024
- Seal exterior penetrations - Sod, sump pump extensions and splash blocks are not installed - Plot plan not ready Builder sent in a TCO extension form. This is the first extension request and builder is actively working on the exterior of th
Miscellaneous Correction
Corrective Action Required
09/30/2024
- Seal exterior penetrations - Sod, sump pump extensions and splash blocks are not installed - Plot plan not ready 10 day letter sent to the builder because no response from email from the City asking for a TCO extension request
Erosion Control Inspection Residential Passed 10/9/2024 10/09/2024
Miscellaneous Correction
Resolved
10/09/2024
Full erosion control measures must be in place and maintained until CofO
Occupancy Inspection - Codes Residential Full C of O 10/9/2024 10/09/2024
Miscellaneous Correction
Resolved
10/09/2024
- Seal exterior penetrations - Sod, sump pump extensions and splash blocks are not installed - Plot plan not ready 10 day letter sent to the builder because no response from email from the City asking for a TCO extension request
Documents & Images
Date Uploaded File Type Document Name
02/08/2024 OS #82 - Permit App
02/13/2024 Letter Codes Residential Plan Review
02/13/2024 Plot Plan approved plot plan
02/13/2024 Approved Plans APPROVED TRUSS LAYOUT
02/13/2024 Approved Plans APPROVED TRUSS PACKAGE
02/13/2024 Approved Plans APPROVED PLANS
02/14/2024 Permit Codes Residential Plan Review
02/14/2024 Permit DS Building Permit
02/14/2024 Receipt Receipt for transaction:2024-000845
03/11/2024 3rd Party Permit/Approval THIRD PARTY INSPECTION
03/12/2024 Letter INSPECTION SUMMARY
03/18/2024 Letter INSPECTION SUMMARY
03/18/2024 Letter INSPECTION SUMMARY
03/18/2024 Letter INSPECTION SUMMARY
03/18/2024 Letter INSPECTION SUMMARY
03/18/2024 Letter INSPECTION SUMMARY
03/18/2024 Letter INSPECTION SUMMARY
03/26/2024 Letter INSPECTION SUMMARY
04/05/2024 Letter INSPECTION SUMMARY
04/09/2024 Letter INSPECTION SUMMARY
04/24/2024 Letter INSPECTION SUMMARY
05/13/2024 Letter INSPECTION SUMMARY
05/13/2024 Letter INSPECTION SUMMARY
05/13/2024 Letter INSPECTION SUMMARY
05/13/2024 Letter INSPECTION SUMMARY
05/13/2024 Letter INSPECTION SUMMARY
05/13/2024 Letter INSPECTION SUMMARY
05/13/2024 Letter INSPECTION SUMMARY
05/17/2024 Letter INSPECTION SUMMARY
05/17/2024 Letter INSPECTION SUMMARY
05/17/2024 Letter INSPECTION SUMMARY
05/21/2024 Engineer Report/Study ENGINEER TRUSS REPAIR
05/21/2024 Letter INSPECTION SUMMARY
05/21/2024 Letter INSPECTION SUMMARY
05/21/2024 Letter INSPECTION SUMMARY
05/22/2024 Letter INSPECTION SUMMARY
05/22/2024 Letter INSPECTION SUMMARY
05/22/2024 Letter INSPECTION SUMMARY
05/28/2024 Letter INSPECTION SUMMARY
06/17/2024 Letter INSPECTION SUMMARY
06/17/2024 Letter INSPECTION SUMMARY
06/25/2024 Letter INSPECTION SUMMARY
06/25/2024 Letter INSPECTION SUMMARY
07/12/2024 Letter INSPECTION SUMMARY
07/12/2024 Letter INSPECTION SUMMARY
07/12/2024 Letter INSPECTION SUMMARY
07/12/2024 Receipt Receipt for transaction:2024-005779
07/16/2024 Letter INSPECTION SUMMARY
07/18/2024 Letter INSPECTION SUMMARY
07/18/2024 Letter INSPECTION SUMMARY
07/18/2024 Certificate/License Codes Temporary Certificate of Occupancy
07/18/2024 Receipt Receipt for transaction:2024-005968
08/07/2024 OS #82 - TCO Extension Request Form
08/13/2024 Letter INSPECTION SUMMARY
08/22/2024 OS 82 TCOExtension Request Form 8_22
08/23/2024 Letter INSPECTION SUMMARY
08/23/2024 Certificate/License Codes Temporary Certificate of Occupancy
08/23/2024 Receipt Receipt for transaction:2024-007155
09/04/2024 Plot Plan approved as graded plot plan
09/05/2024 Letter INSPECTION SUMMARY
09/05/2024 Letter INSPECTION SUMMARY
09/30/2024 Letter Codes 10 Day Letter
09/30/2024 Letter Codes 10 Day Letter
09/30/2024 Letter INSPECTION SUMMARY
09/30/2024 Certificate/License Codes Temporary Certificate of Occupancy
09/30/2024 Receipt Receipt for transaction:2024-008008
10/08/2024 OS #82 - TCO Extension Request Form 10_8_2024
10/08/2024 OS 82 ASBUILT
10/08/2024 Plot Plan approved as graded plot plan
10/09/2024 Letter INSPECTION SUMMARY
10/09/2024 Letter Field Certificate of Occupancy
10/09/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home