Permit Application Status

PRRES20236557


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20236557
Building Permit - Residential
Certificate of Occupancy
NEW 3 OR 4 FAMILY
NEW TOWNHOME. UNFINISHED BASEMENT. ROOF TRUSSES. FINISHED BASEMENTS IN UNITS 3721 AND 3727.
12/15/2023
01/02/2024
06/16/2024
09/16/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
JASONH@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New 3 or 4 Family $4,933.68 $4,933.68 Paid 01/02/2024
Water Tap Fee $15,040.00 $15,040.00 Paid 01/02/2024
Water Meter Fee $2,721.84 $2,721.84 Paid 01/02/2024
Sanitary Sewer Development Fee $8,636.00 $8,636.00 Paid 01/02/2024
Right of Way Permit Fee $85.00 $85.00 Paid 01/02/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 04/11/2024
Valuation Fee for Add/Alter 3 or 4 Family $71.05 $71.05 Paid 04/11/2024
$5,004.73
Not Ready Inspection Fee $75.00 $75.00 Paid 07/10/2024
3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 07/10/2024
3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 07/10/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 07/10/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 07/11/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 07/16/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 09/11/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/14/2024 02/14/2024
Miscellaneous Correction
Informational
02/14/2024
Verified and passed by a third party.
Erosion Control Inspection Residential Failed 2/21/2024 02/21/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/21/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Gravel needs to be spread
Sewer Service Inspection - R Passed 2/27/2024 2/27/2024 02/27/2024
Misc
Informational
02/27/2024
3721,3723 inspected and passed 3725 and 3727 not ready
Sewer Service Inspection - R Passed 2/28/2024 2/28/2024 02/28/2024
Underslab Plumbing Inspection - Residential Passed 2/28/2024 2/28/2024 02/28/2024
Misc
Informational
02/28/2024
** UNITS - 3721,3723,3725,3727 OK
Underslab Electrical Inspection - Residential Passed 2/28/2024 2/28/2024 02/28/2024
Misc
Informational
02/28/2024
** UNITS - 3721,3723,3725,3727 OK
Erosion Control Inspection Residential Failed 2/29/2024 02/29/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/21/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Gravel needs to be spread
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
02/29/2024
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Water Service Inspection - R Passed 2/29/2024 02/29/2024
Misc
Informational
02/29/2024
- Inspected 3721,3723,3725,3727
All Rough Inspection - Residential Partial 3/21/2024 3/21/2024 03/21/2024
Miscellaneous Correction
Informational
03/21/2024
Garage portal CS-PF passed.Okay to cover. This is a partial pass only.
Erosion Control Inspection Residential Partial 3/26/2024 03/26/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
03/26/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Gravel needs to be spread
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
03/26/2024
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Miscellaneous Correction
Informational
03/26/2024
Full erosion control is in place and needs to be maintained until CofO
All Rough Inspection - Residential Not Ready 3/26/2024 3/26/2024 03/26/2024
Miscellaneous Correction
Informational
03/21/2024
Garage portal CS-PF passed.Okay to cover. This is a partial pass only.
Miscellaneous Correction
Corrective Action Required
03/26/2024
All rough inspection was scheduled. M.E.P’s not completed and structure is not finished going vertical. Walk your property before scheduling inspections. Not ready
All Rough Inspection - Residential Failed 4/23/2024 4/23/2024 04/23/2024
Miscellaneous Correction
Informational
03/26/2024
Garage portal CS-PF passed.Okay to cover. This is a partial pass only.
Miscellaneous Correction
Resolved
04/23/2024
All rough inspection was scheduled. M.E.P’s not completed and structure is not finished going vertical. Walk your property before scheduling inspections. Not ready
Miscellaneous Correction
Corrective Action Required
04/23/2024
3725 and 3727 SW Clayton. All rough (2) 3725 Basement 2x10 under powder bath has been over cut for waste line Fire block 2x10 cavity between basement and garage Studs in the basement between the HVAC and stairs do not meet at the top plate Nails missing in joist hanger in basement above steel column and Ibeam Anchor bolt not tightened down in basement west wall Fire block basement S/E corner Nail removal tool is supporting basement Ibeam at south wall Top of stair stringer at stair landing for change of direction does not bear 1 1/2 inches against the 2x10 support LIB in kitchen is missing nails Nail entry corner to code 2x10 ceiling joist in entry has been over cut for waste line Fire top of HVAC chase in bedroom 2 Attic access does not have 30 inches of head room above the top of the 2x6 Flex vent pipe from bathroom 2 does not vent outside Truss down down screw is missing in bedroom 3 by the window LIB in bedroom 3 is missing nails Nail corner of shower 1 to code Utility room dryer vent is not completed Garage anchor bolts need to be in the middle 1/3 of sole plate and within 4-12 inches from each end Install 2x4 for truss support in garage to room 1 above Nail garage N/E corner to code 3727 Garage anchor bolts must be in the middle 1/3 of sole plate Of install 2x4 for garage truss support in garage to room 1 Nails missing in joist hangers at garage entry to kitchen and closet to living room Fire block bottom plate in kitchen Nail kitchen N/E corner to code Install joist hangers above entry porch that were cut for plumbing Fire block one joist space at front porch to entry Fire block top of HVAC chase in bedroom 2 Bedroom 3 , bath 2 and walk in closet needs joint hangers installed at truss and girder beam Bathroom 2 vent pipe is missing Utility dryer vent is incomplete Stud shoe in WIC is missing a nail Stair stringer from main living up to platform does not rest on 11/2 inches of the 2x10 Fire block joist cavity between basement and garage Tightened anchor bolts in basement sole plate 3723 Not inspected 3721 Not inspected This is a partial inspection only
Gas Service Inspection - Residential Partial 4/23/2024 4/23/2024 04/23/2024
Miscellaneous Correction
Informational
04/23/2024
Gas passed at 3725 and 3727 only This is a partial gas inspection and pass only
Electrical Service Inspection Partial 4/23/2024 4/23/2024 04/23/2024
Miscellaneous Correction
Informational
04/23/2024
Electrical inspection at 3725 and 3727 passed only This was a partial electrical inspection . Other units will be scheduled at a later date This is a partial pass only
Rated Assembly Inspection Failed 4/23/2024 4/23/2024 04/23/2024
Miscellaneous Correction
Corrective Action Required
04/23/2024
3727 Passed 3725 -Fire blocking is missing in top plate at garage north wall -Fire block top plate in entry at electrical wires -Vertical fire block every 10 feet at stairwell to North West bedroom -Remove wood at the ridge on North side -Vertically fire block N/E bedroom’s north wall every 10 feet - This is a partial electrical inspection only - Other units will be scheduled at a later date
Rated Assembly Inspection Failed 4/25/2024 4/25/2024 04/25/2024
Miscellaneous Correction
Corrective Action Required
04/23/2024
3727 Passed 3725 -Fire blocking is missing in top plate at garage north wall -Fire block top plate in entry at electrical wires -Vertical fire block every 10 feet at stairwell to North West bedroom -Remove wood at the ridge on North side -Vertically fire block N/E bedroom’s north wall every 10 feet -Fire rated assembly missing in common roof gable between unit 3725 and 3723 3723 -Vertical fire blocking missing at stairwell platform -Damage to fire rated plywood at ridge south side -Fire rated assembly missing in common roof gable between unit 3723 and 3725 -Vertical fire block missing in upstairs walk in closet 3721 -fire rated plywood on roofs east side has a larger than 1/4 inch gap -Repair broken fire rated plywood edge on west side
All Rough Inspection - Residential Failed 4/25/2024 4/25/2024 04/25/2024
Miscellaneous Correction
Informational
04/23/2024
Garage portal CS-PF passed.Okay to cover. This is a partial pass only.
Miscellaneous Correction
Corrective Action Required
04/23/2024
3721,3723, 3725 and 3727 SW Clayton. All rough (3) 3725 -Basement 2x10 under powder bath has been over cut for waste line -Fire block 2x10 cavity between basement and garage -Studs in the basement between the HVAC and stairs do not meet at the top plate -Nails missing in joist hanger in basement above steel column and Ibeam -Anchor bolt not tightened down in basement west wall -Fire block basement S/E corner -Nail removal tool is supporting basement Ibeam at south wall -Top of stair stringer at stair landing for change of direction does not bear 1 1/2 inches against the 2x10 support -LIB in kitchen is missing nails -Nail entry corner to code -2x10 ceiling joist in entry has been over cut for waste line -Fire top of HVAC chase in bedroom 2 -Attic access does not have 30 inches of head room above the top of the 2x6 -Flex vent pipe from bathroom 2 does not vent outside -Truss down down screw is missing in bedroom 3 by the window -LIB in bedroom 3 is missing nails -Nail corner of shower 1 to code -Utility room dryer vent is not completed -Garage anchor bolts need to be in the middle 1/3 of sole plate and within 4-12 inches from each end -Install 2x4 for truss support in garage to room 1 above -Nail garage N/E corner to code 3727 -Garage anchor bolts must be in the middle 1/3 of sole plate -install 2x4 for garage truss support in garage to room 1 -Nails missing in joist hangers at garage entry to kitchen and closet to living room -Fire block bottom plate in kitchen -Nail kitchen N/E corner to code -Install joist hangers above entry porch that were cut for plumbing -Fire block one joist space at front porch to entry -Fire block top of HVAC chase in bedroom 2 -Bedroom 3 , bath 2 and walk in closet needs joint hangers installed at truss and girder beam -Bathroom 2 vent pipe is missing -Utility dryer vent is incomplete -Stud shoe in WIC is missing a nail -Stair stringer from main living up to platform does not rest on 11/2 inches of the 2x10 -Fire block joist cavity between basement and garage -Tightened anchor bolts in basement sole plate 3721 -Trusses in garage to bedroom 1 needs a 2x4 for truss support -Nail garage corners to code -Anchor bolts in the garage needs to be in the middle 1/3 of sole plate -Pantry to owners entry is required to has a 3 2x6 vertical stud pack -2x10 porch joist for plumbing waste line has been over bored -First flight of stair stringers from kitchen going to upstairs does not set 1 1/2 inches on the 2x10 rim joist -2 continuous 2x10 headers are not installed at windows in bedroom 1 -Fire block top of chases in bedroom 1 shower -Dryer vent in utility room is not completed Install joist hangers for trusses in WIC, bath 2 and bedroom 3 -Bathroom 2 vent is not completed HVAC in bathroom 2 in falling down -Nail double truss together above bedroom 3, bathroom 2 and WIC -Tie down electrical 12/2 in basement chase -Anchor bolt is missing in basement N/E corner -Tie down electrical 12/2 in basement HVAC chase 3723 - Not inspected. Property is not ready to be inspected because of to many similar issues found on the other three units -Framer is still working on the inside -Please walk your property before scheduling an inspection Not a complete list
All Rough Inspection - Residential Failed 4/30/2024 4/30/2024 04/30/2024
Miscellaneous Correction
Informational
04/25/2024
Garage portal CS-PF passed.Okay to cover. This is a partial pass only.
Miscellaneous Correction
Corrective Action Required
04/25/2024
3721,3723, 3725 and 3727 SW Clayton. All rough (4) 3725 -Basement 2x10 under powder bath has been over cut for waste line -Fire block 2x10 cavity between basement and garage -Studs in the basement between the HVAC and stairs do not meet at the top plate -Nails missing in joist hanger in basement above steel column and Ibeam -Anchor bolt not tightened down in basement west wall -Fire block basement S/E corner -Nail removal tool is supporting basement Ibeam at south wall -Top of stair stringer at stair landing for change of direction does not bear 1 1/2 inches against the 2x10 support -LIB in kitchen is missing nails -Nail entry corner to code -2x10 ceiling joist in entry has been over cut for waste line -Fire top of HVAC chase in bedroom 2 -Attic access does not have 30 inches of head room above the top of the 2x6 -Flex vent pipe from bathroom 2 does not vent outside -Truss down down screw is missing in bedroom 3 by the window -LIB in bedroom 3 is missing nails -Nail corner of shower 1 to code -Utility room dryer vent is not completed -Garage anchor bolts need to be in the middle 1/3 of sole plate and within 4-12 inches from each end -Install 2x4 for truss support in garage to room 1 above -Nail garage N/E corner to code 3727 -Garage anchor bolts must be in the middle 1/3 of sole plate -install 2x4 for garage truss support in garage to room 1 -Nails missing in joist hangers at garage entry to kitchen and closet to living room -Fire block bottom plate in kitchen -Nail kitchen N/E corner to code -Install joist hangers above entry porch that were cut for plumbing -Fire block one joist space at front porch to entry -Fire block top of HVAC chase in bedroom 2 -Bedroom 3 , bath 2 and walk in closet needs joint hangers installed at truss and girder beam -Bathroom 2 vent pipe is missing -Utility dryer vent is incomplete -Stud shoe in WIC is missing a nail -Stair stringer from main living up to platform does not rest on 11/2 inches of the 2x10 -Fire block joist cavity between basement and garage -Tightened anchor bolts in basement sole plate 3721 -Trusses in garage to bedroom 1 needs a 2x4 for truss support -Nail garage corners to code -Anchor bolts in the garage needs to be in the middle 1/3 of sole plate -Pantry to owners entry is required to has a 3 2x6 vertical stud pack -2x10 porch joist for plumbing waste line has been over bored -First flight of stair stringers from kitchen going to upstairs does not set 1 1/2 inches on the 2x10 rim joist -2 continuous 2x10 headers are not installed at windows in bedroom 1 -Fire block top of chases in bedroom 1 shower -Dryer vent in utility room is not completed Install joist hangers for trusses in WIC, bath 2 and bedroom 3 -Bathroom 2 vent is not completed HVAC in bathroom 2 in falling down -Nail double truss together above bedroom 3, bathroom 2 and WIC -Tie down electrical 12/2 in basement chase -Anchor bolt is missing in basement N/E corner -Tie down electrical 12/2 in basement HVAC chase 3723 -LIB in kitchen is missing nails -Utility dryer vent is not completed -WIC needs to be vertically fire blocked every 10 feet -Bathroom 2 vent pipe is not completed -Outside corner of bedroom 3 needs to be nailed to code -Top of HVAC chase by bedroom 2 needs to be fire blocked -Fire block double 2x10 in basement under stairs to garage -Fire block powder bathroom to basement at waste line in floor -Washers are being used as shims under basement Ibeam for support -Fire block gaps in N/E corner of basement -Fire rated assembly wall is not continuous from bottom floor through to the common attic to the underside of the roof between 3723 and 3725
Gas Service Inspection - Residential Passed 4/30/2024 4/30/2024 04/30/2024
Miscellaneous Correction
Resolved
04/30/2024
Gas passed at 3725 and 3727 only This is a partial gas inspection and pass only
Electrical Service Inspection Passed 4/30/2024 4/30/2024 04/30/2024
Miscellaneous Correction
Resolved
04/30/2024
Electrical inspection at 3725 and 3727 passed only This was a partial electrical inspection . Other units will be scheduled at a later date This is a partial pass only
Erosion Control Inspection Residential Partial 4/30/2024 04/30/2024
Miscellaneous Correction
Resolved
04/30/2024
Full erosion control is in place and needs to be maintained until CofO
Miscellaneous Correction
Informational
04/30/2024
Full erosion control is in place and needs to be maintained until CofO
Rated Assembly Inspection Failed 5/2/2024 5/2/2024 05/02/2024
Miscellaneous Correction
Resolved
05/02/2024
3727 Passed 3725 -Fire blocking is missing in top plate at garage north wall -Fire block top plate in entry at electrical wires -Vertical fire block every 10 feet at stairwell to North West bedroom -Remove wood at the ridge on North side -Vertically fire block N/E bedroom’s north wall every 10 feet -Fire rated assembly missing in common roof gable between unit 3725 and 3723 3723 -Vertical fire blocking missing at stairwell platform -Damage to fire rated plywood at ridge south side -Fire rated assembly missing in common roof gable between unit 3723 and 3725 -Vertical fire block missing in upstairs walk in closet 3721 -fire rated plywood on roofs east side has a larger than 1/4 inch gap -Repair broken fire rated plywood edge on west side
Miscellaneous Correction
Corrective Action Required
05/02/2024
Fire rated assembly missing in common roof gable between unit 3723 and 3725 (Fire rated assembly is not completed)
All Rough Inspection - Residential Failed 5/2/2024 5/2/2024 05/02/2024
Miscellaneous Correction
Resolved
05/02/2024
Garage portal CS-PF passed.Okay to cover. This is a partial pass only.
Miscellaneous Correction
Resolved
05/02/2024
3721,3723, 3725 and 3727 SW Clayton. All rough (4) 3725 -Basement 2x10 under powder bath has been over cut for waste line -Fire block 2x10 cavity between basement and garage -Studs in the basement between the HVAC and stairs do not meet at the top plate -Nails missing in joist hanger in basement above steel column and Ibeam -Anchor bolt not tightened down in basement west wall -Fire block basement S/E corner -Nail removal tool is supporting basement Ibeam at south wall -Top of stair stringer at stair landing for change of direction does not bear 1 1/2 inches against the 2x10 support -LIB in kitchen is missing nails -Nail entry corner to code -2x10 ceiling joist in entry has been over cut for waste line -Fire top of HVAC chase in bedroom 2 -Attic access does not have 30 inches of head room above the top of the 2x6 -Flex vent pipe from bathroom 2 does not vent outside -Truss down down screw is missing in bedroom 3 by the window -LIB in bedroom 3 is missing nails -Nail corner of shower 1 to code -Utility room dryer vent is not completed -Garage anchor bolts need to be in the middle 1/3 of sole plate and within 4-12 inches from each end -Install 2x4 for truss support in garage to room 1 above -Nail garage N/E corner to code 3727 -Garage anchor bolts must be in the middle 1/3 of sole plate -install 2x4 for garage truss support in garage to room 1 -Nails missing in joist hangers at garage entry to kitchen and closet to living room -Fire block bottom plate in kitchen -Nail kitchen N/E corner to code -Install joist hangers above entry porch that were cut for plumbing -Fire block one joist space at front porch to entry -Fire block top of HVAC chase in bedroom 2 -Bedroom 3 , bath 2 and walk in closet needs joint hangers installed at truss and girder beam -Bathroom 2 vent pipe is missing -Utility dryer vent is incomplete -Stud shoe in WIC is missing a nail -Stair stringer from main living up to platform does not rest on 11/2 inches of the 2x10 -Fire block joist cavity between basement and garage -Tightened anchor bolts in basement sole plate 3721 -Trusses in garage to bedroom 1 needs a 2x4 for truss support -Nail garage corners to code -Anchor bolts in the garage needs to be in the middle 1/3 of sole plate -Pantry to owners entry is required to has a 3 2x6 vertical stud pack -2x10 porch joist for plumbing waste line has been over bored -First flight of stair stringers from kitchen going to upstairs does not set 1 1/2 inches on the 2x10 rim joist -2 continuous 2x10 headers are not installed at windows in bedroom 1 -Fire block top of chases in bedroom 1 shower -Dryer vent in utility room is not completed Install joist hangers for trusses in WIC, bath 2 and bedroom 3 -Bathroom 2 vent is not completed HVAC in bathroom 2 in falling down -Nail double truss together above bedroom 3, bathroom 2 and WIC -Tie down electrical 12/2 in basement chase -Anchor bolt is missing in basement N/E corner -Tie down electrical 12/2 in basement HVAC chase 3723 -LIB in kitchen is missing nails -Utility dryer vent is not completed -WIC needs to be vertically fire blocked every 10 feet -Bathroom 2 vent pipe is not completed -Outside corner of bedroom 3 needs to be nailed to code -Top of HVAC chase by bedroom 2 needs to be fire blocked -Fire block double 2x10 in basement under stairs to garage -Fire block powder bathroom to basement at waste line in floor -Washers are being used as shims under basement Ibeam for support -Fire block gaps in N/E corner of basement -Fire rated assembly wall is not continuous from bottom floor through to the common attic to the underside of the roof between 3723 and 3725
Miscellaneous Correction
Corrective Action Required
05/02/2024
3721-3727 All rough 3721 2x10 porch joist for plumbing waste line has been over bored( add new 2x10 joist for extra support. The upstairs toilet sits on just plywood and needs weight support) 2 continuous 2x10 headers are not installed at windows in bedroom 1 (have engineer address) Fire block top of chases in bedroom 1 shower (fire block 1/4 inch gaps) HVAC in bathroom 2 in falling down 3723-3725&3727 all passed all rough DO NOT INSULATE util all rough and rated assembly all pass. KBEARD
Rated Assembly Inspection Passed 5/8/2024 5/8/2024 05/08/2024
Miscellaneous Correction
Resolved
05/08/2024
Fire rated assembly missing in common roof gable between unit 3723 and 3725 (Fire rated assembly is not completed)
All Rough Inspection - Residential Passed 5/8/2024 5/8/2024 05/08/2024
Miscellaneous Correction
Resolved
05/08/2024
3721-3727 All rough 3721 2x10 porch joist for plumbing waste line has been over bored( add new 2x10 joist for extra support. The upstairs toilet sits on just plywood and needs weight support) 2 continuous 2x10 headers are not installed at windows in bedroom 1 (have engineer address) Fire block top of chases in bedroom 1 shower (fire block 1/4 inch gaps) HVAC in bathroom 2 in falling down 3723-3725&3727 all passed all rough DO NOT INSULATE util all rough and rated assembly all pass. KBEARD
Rated Assembly Inspection Partial 5/14/2024 5/14/2024 05/14/2024
Miscellaneous Correction
Informational
05/14/2024
Screw pattern for 3723 and 3725 passed, other two units will be scheduled another day. This is a partial pass only.
Erosion Control Inspection Residential Failed 5/14/2024 05/14/2024
Miscellaneous Correction
Informational
04/30/2024
Full erosion control is in place and needs to be maintained until CofO
Miscellaneous Correction
Corrective Action Required
05/14/2024
Straw waddle along the north side at the street is missing or damaged and needs to be replaced or repaired. Full erosion control must be maintained until CofO
Rated Assembly Inspection Passed 5/15/2024 5/15/2024 05/15/2024
Driveway Inspection Partial 5/20/2024 5/20/2024 05/20/2024
Misc
Informational
05/20/2024
5-20-24 PS Driveway approach pre pour, all four units, forms in place, aggregate compacted, approved to pour
Sidewalk Inspection Partial 5/20/2024 5/20/2024 05/20/2024
Misc
Informational
05/20/2024
5-20-24 PS sidewalk pre pour, all four units, forms in place, aggregate compacted, approved to pour
Piers/Caissons Inspection - Residential Failed 6/28/2024 6/28/2024 06/28/2024
Miscellaneous Correction
Corrective Action Required
06/28/2024
-3727 is the only unit that was ready for a pier inspection. -3727 piers were only 24 inches deep -This was a partial pier inspection only Please schedule future units by exact address
Piers/Caissons Inspection - Residential Failed 6/28/2024 6/28/2024 06/28/2024
Miscellaneous Correction
Resolved
06/28/2024
-3727 is the only unit that was ready for a pier inspection. -3727 piers were only 24 inches deep -This was a partial pier inspection only Please schedule future units by exact address
Miscellaneous Correction
Informational
06/28/2024
Unit 3727 passed All other units were not ready for inspection PLEASE NOTE WHICH UNIT NEEDS TO BE INSPECTED WHEN YOU SCHEDULE AN INSPECTION
Piers/Caissons Inspection - Residential Failed 7/2/2024 07/02/2024
Miscellaneous Correction
Resolved
07/02/2024
Unit 3727 passed All other units were not ready for inspection PLEASE NOTE WHICH UNIT NEEDS TO BE INSPECTED WHEN YOU SCHEDULE AN INSPECTION
Miscellaneous Correction
Corrective Action Required
07/02/2024
Unit 3725 passed Both 3725 and 3727 have passed All other units were not ready for inspection PLEASE NOTE WHICH UNIT NEEDS TO BE INSPECTED WHEN YOU SCHEDULE AN INSPECTION (second and final warning before a not ready fee is added)
Piers/Caissons Inspection - Residential Not Ready 7/8/2024 7/8/2024 07/08/2024
Miscellaneous Correction
Corrective Action Required
07/02/2024
Unit 3725 passed Both 3725 and 3727 have passed All other units were not ready for inspection PLEASE NOTE WHICH UNIT NEEDS TO BE INSPECTED WHEN YOU SCHEDULE AN INSPECTION (second and final warning before a not ready fee is added)
Miscellaneous Correction
Corrective Action Required
07/08/2024
-Units 3727 and 3725 have passed already -Unit 3723 is the only unit ready for inspection at this time. -Unit 3721 was not ready for inspection Not ready fee assessed
Piers/Caissons Inspection - Residential Passed 7/9/2024 07/09/2024
Miscellaneous Correction
Resolved
07/09/2024
Unit 3725 passed Both 3725 and 3727 have passed All other units were not ready for inspection PLEASE NOTE WHICH UNIT NEEDS TO BE INSPECTED WHEN YOU SCHEDULE AN INSPECTION (second and final warning before a not ready fee is added)
Miscellaneous Correction
Resolved
07/09/2024
-Units 3727 and 3725 have passed already -Unit 3723 is the only unit ready for inspection at this time. -Unit 3721 was not ready for inspection Not ready fee assessed
Occupancy Inspection - Codes Residential Failed 7/11/2024 7/11/2024 07/11/2024
Miscellaneous Correction
Corrective Action Required
07/11/2024
3721-3723-3725 and 3727 SW Clayton Occupancy 3721 Kitchen electrical receptacles do not trip Missing anti water hammer arrestor under kitchen sink First stair riser from main floor going up has a height of 8 inches Garage to house self closing hinge is not working Fire block all holes in sheet rock in garage at ceiling Seal bottom of chases in garage Stairwell going to basement at intermediate platform does not have the code required 36 inches of travel distance Handrail at the basement bottom step does not meet at stair nosing Electrical wires are exposed at basement bathroom for lighting fixture Electrical Ufer is not exposed Electrical panel is not labeled Top of stairs to upper floor landing has a riser height greater then the code allowed 7 3/4 inches Water anti hammer arrestor in utility room is not installed GFCI in utility room will not reset 3723 Kitchen electrical receptacles are not working Anti water hammer arrestor under kitchen sink is not installed First stair riser up from floor has a height of 8 inches Fire block all holes in sheet rock in garage to ceiling Seal bottom of chases in garage Last riser up from the basement to the main floor has a height greater than the code allowable 7 3/4 inches Electrical panel is not labeled GFCI in basement does not work Water hammer arrestor is not installed in utility room 3725 and 3727 Not inspected due to reoccurring deficiencies in other units NOT A COMPLETE LIST All units Sod, splash pads and patio stair landing s are not installed Seal top of meter cans Seal all exterior penetrations at siding Nails missing in back patio joist hangers
Erosion Control Inspection Residential Partial 7/11/2024 07/11/2024
Miscellaneous Correction
Resolved
07/11/2024
Full erosion control is in place and needs to be maintained until CofO
Miscellaneous Correction
Resolved
07/11/2024
Straw waddle along the north side at the street is missing or damaged and needs to be replaced or repaired. Full erosion control must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
07/11/2024
Full erosion control is in place and needs to be maintained until CofO
Occupancy Inspection - Codes Residential Not Ready 7/11/2024 07/11/2024
Miscellaneous Correction
Corrective Action Required
07/11/2024
3721-3723-3725 and 3727 SW Clayton Occupancy 3721 Kitchen electrical receptacles do not trip Missing anti water hammer arrestor under kitchen sink First stair riser from main floor going up has a height of 8 inches Garage to house self closing hinge is not working Fire block all holes in sheet rock in garage at ceiling Seal bottom of chases in garage Stairwell going to basement at intermediate platform does not have the code required 36 inches of travel distance Handrail at the basement bottom step does not meet at stair nosing Electrical wires are exposed at basement bathroom for lighting fixture Electrical Ufer is not exposed Electrical panel is not labeled Top of stairs to upper floor landing has a riser height greater then the code allowed 7 3/4 inches Water anti hammer arrestor in utility room is not installed GFCI in utility room will not reset 3723 Kitchen electrical receptacles are not working Anti water hammer arrestor under kitchen sink is not installed First stair riser up from floor has a height of 8 inches Fire block all holes in sheet rock in garage to ceiling Seal bottom of chases in garage Last riser up from the basement to the main floor has a height greater than the code allowable 7 3/4 inches Electrical panel is not labeled GFCI in basement does not work Water hammer arrestor is not installed in utility room 3725 and 3727 Not inspected due to reoccurring deficiencies in other units NOT A COMPLETE LIST All units Sod, splash pads and patio stair landing s are not installed Seal top of meter cans Seal all exterior penetrations at siding Nails missing in back patio joist hangers NOT READY FOR INSPECTION
Plot Plan Inspection Failed 7/11/2024 07/11/2024
Miscellaneous Correction
Corrective Action Required
07/11/2024
As graded plot plan is required before any installation of sod
Driveway Inspection Passed 7/11/2024 7/11/2024 07/11/2024
Misc
Informational
05/20/2024
5-20-24 PS Driveway approach pre pour, all four units, forms in place, aggregate compacted, approved to pour 7-11-24 PS approach meets ADA and LS specs
Sidewalk Inspection Passed 7/11/2024 7/11/2024 07/11/2024
Misc
Informational
05/20/2024
5-20-24 PS sidewalk pre pour, all four units, forms in place, aggregate compacted, approved to pour 7-11-24 PS Sidewalk meets ADA and LS specs
Occupancy Inspection - Codes Residential Failed 7/12/2024 7/12/2024 07/12/2024
Miscellaneous Correction
Corrective Action Required
07/11/2024
3721-3723-3725 and 3727 SW Clayton Occupancy 3721 Kitchen electrical receptacles do not trip Missing anti water hammer arrestor under kitchen sink First stair riser from main floor going up has a height of 8 inches Garage to house self closing hinge is not working Fire block all holes in sheet rock in garage at ceiling Seal bottom of chases in garage Stairwell going to basement at intermediate platform does not have the code required 36 inches of travel distance Handrail at the basement bottom step does not meet at stair nosing Electrical wires are exposed at basement bathroom for lighting fixture Electrical Ufer is not exposed Electrical panel is not labeled Top of stairs to upper floor landing has a riser height greater then the code allowed 7 3/4 inches Water anti hammer arrestor in utility room is not installed GFCI in utility room will not reset 3723 Kitchen electrical receptacles are not working Anti water hammer arrestor under kitchen sink is not installed First stair riser up from floor has a height of 8 inches Fire block all holes in sheet rock in garage to ceiling Seal bottom of chases in garage Last riser up from the basement to the main floor has a height greater than the code allowable 7 3/4 inches Electrical panel is not labeled GFCI in basement does not work Water hammer arrestor is not installed in utility room All units Sod, splash pads and patio stair landing s are not installed Seal top of meter cans Seal all exterior penetrations at siding Nails missing in back patio joist hangers 3727 and 3725. 3727 hot water heater in electrical panel needs a lock out installed Ceiling in basement does not have 6’8” of head clearance Landing in hallway going to the basement does not have 36 inches of travel distance Kitchen backsplash GFCI is not working Back porch electrical receptacle cover needs to be replaced Front porch needs a guardrail installed Bathroom 1 GFCI does not work Top riser to upper floor has a greater than 7 3/4 inches in height Fire block bottom of chases in the garage 3725 Address numbers need to be lowered for proper illumination Hot water heater hot water side is in contact with 12/2 electrical wire and whip First riser step down from the main living room has a height greater then 7 3/4 inches Some electrical receptacles and switches have gaps next to them Fire block bottom of chases in garage -Exterior splash pads, sump pump extensions Are not installed -Seal all exterior penetrations -Back patio landing pads are not installed -Plot grading is not completed Units 3723 and 3721 are listed separately
Occupancy Inspection - Codes Residential Ready for Temp CO 7/16/2024 7/16/2024 07/16/2024
Miscellaneous Correction
Resolved
07/16/2024
3721-3723-3725 and 3727 SW Clayton Occupancy 3721 Kitchen electrical receptacles do not trip Missing anti water hammer arrestor under kitchen sink First stair riser from main floor going up has a height of 8 inches Garage to house self closing hinge is not working Fire block all holes in sheet rock in garage at ceiling Seal bottom of chases in garage Stairwell going to basement at intermediate platform does not have the code required 36 inches of travel distance Handrail at the basement bottom step does not meet at stair nosing Electrical wires are exposed at basement bathroom for lighting fixture Electrical Ufer is not exposed Electrical panel is not labeled Top of stairs to upper floor landing has a riser height greater then the code allowed 7 3/4 inches Water anti hammer arrestor in utility room is not installed GFCI in utility room will not reset 3723 Kitchen electrical receptacles are not working Anti water hammer arrestor under kitchen sink is not installed First stair riser up from floor has a height of 8 inches Fire block all holes in sheet rock in garage to ceiling Seal bottom of chases in garage Last riser up from the basement to the main floor has a height greater than the code allowable 7 3/4 inches Electrical panel is not labeled GFCI in basement does not work Water hammer arrestor is not installed in utility room All units Sod, splash pads and patio stair landing s are not installed Seal top of meter cans Seal all exterior penetrations at siding Nails missing in back patio joist hangers 3727 and 3725. 3727 hot water heater in electrical panel needs a lock out installed Ceiling in basement does not have 6’8” of head clearance Landing in hallway going to the basement does not have 36 inches of travel distance Kitchen backsplash GFCI is not working Back porch electrical receptacle cover needs to be replaced Front porch needs a guardrail installed Bathroom 1 GFCI does not work Top riser to upper floor has a greater than 7 3/4 inches in height Fire block bottom of chases in the garage 3725 Address numbers need to be lowered for proper illumination Hot water heater hot water side is in contact with 12/2 electrical wire and whip First riser step down from the main living room has a height greater then 7 3/4 inches Some electrical receptacles and switches have gaps next to them Fire block bottom of chases in garage -Exterior splash pads, sump pump extensions Are not installed -Seal all exterior penetrations -Back patio landing pads are not installed -Plot grading is not completed Units 3723 and 3721 are listed separately
Miscellaneous Correction
Corrective Action Required
07/16/2024
Exterior splash pads, sump pump extensions Are not installed -Seal all exterior penetrations -Back patio landing pads are not installed -Plot grading is not completed All units passed for TCO only
Plot Plan Inspection Failed 8/15/2024 08/15/2024
Miscellaneous Correction
Resolved
08/15/2024
As graded plot plan is required before any installation of sod
Miscellaneous Correction
Corrective Action Required
08/15/2024
As graded plot plan is required before any installation of sod Plot still has not had a final grade done for a plot plan inspection
Erosion Control Inspection Residential Failed 8/15/2024 08/15/2024
Miscellaneous Correction
Resolved
08/15/2024
Full erosion control is in place and needs to be maintained until CofO
Miscellaneous Correction
Corrective Action Required
08/15/2024
Erosion control measures needs to be in place along the east side of the property up against a newly sodded lawn and the storm drain at the S/E corner needs to be protected from dirt and debris that can enter and clog up the system EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM3 ESC REQUIRED 2 DAY
Resolved
08/15/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Plot Plan Inspection Passed 8/21/2024 08/21/2024
Miscellaneous Correction
Resolved
08/21/2024
As graded plot plan is required before any installation of sod Plot still has not had a final grade done for a plot plan inspection
Erosion Control Inspection Residential Partial 8/21/2024 08/21/2024
Miscellaneous Correction
Resolved
08/21/2024
Erosion control measures needs to be in place along the east side of the property up against a newly sodded lawn and the storm drain at the S/E corner needs to be protected from dirt and debris that can enter and clog up the system EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Miscellaneous Correction
Informational
08/21/2024
Erosion control measures are in place and must be maintained until CofO
Occupancy Inspection - Codes Residential Ready for Temp CO 8/23/2024 08/23/2024
Miscellaneous Correction
Corrective Action Required
07/16/2024
Exterior splash pads, sump pump extensions Are not installed -Seal all exterior penetrations -Back patio landing pads are not installed -Plot grading is not completed All units passed for TCO only Builder sent in a TCO extension form and is visually working on this property. This is the first extension form on this permit
Erosion Control Inspection Residential Passed 9/12/2024 09/12/2024
Miscellaneous Correction
Resolved
09/12/2024
Erosion control measures are in place and must be maintained until CofO
Occupancy Inspection - Codes Residential Failed 9/12/2024 9/12/2024 09/12/2024
Miscellaneous Correction
Resolved
09/12/2024
Exterior splash pads, sump pump extensions Are not installed -Seal all exterior penetrations -Back patio landing pads are not installed -Plot grading is not completed All units passed for TCO only Builder sent in a TCO extension form and is visually working on this property. This is the first extension form on this permit
Miscellaneous Correction
Corrective Action Required
09/12/2024
Fully uncover water meter lid at unit 3727 Lower water meter to ground level at unit 3721 All other items have passed
Occupancy Inspection - Codes Residential Full C of O 9/16/2024 9/16/2024 09/16/2024
Miscellaneous Correction
Resolved
09/16/2024
Fully uncover water meter lid at unit 3727 Lower water meter to ground level at unit 3721 All other items have passed
Documents & Images
Date Uploaded File Type Document Name
12/15/2023 OS # 47 - PERMIT APP
12/19/2023 Permit Codes Residential Plan Review
12/21/2023 Plot Plan APPROVED PLOT PLAN
12/21/2023 Approved Plans APPROVED TRUSS PACKAGE
12/21/2023 Approved Plans APPROVED TRUSS LAYOUT
12/21/2023 Approved Plans APPROVED PLANS
12/21/2023 Permit Codes Residential Plan Review
01/02/2024 Permit DS Building Permit
01/02/2024 Receipt Receipt for transaction:2024-000026
02/13/2024 M L Crose 3721, 3723, 3725, 3727 SW Clayton Pl LSMO Osage Lot 47 Clayton P 2023-6557 3rd Party Footing Inspection Report 2-12-24
02/14/2024 Letter INSPECTION SUMMARY
02/21/2024 Letter INSPECTION SUMMARY
02/27/2024 Letter INSPECTION SUMMARY
02/28/2024 Letter INSPECTION SUMMARY
02/28/2024 Letter INSPECTION SUMMARY
02/28/2024 Letter INSPECTION SUMMARY
02/29/2024 Letter INSPECTION SUMMARY
02/29/2024 Letter INSPECTION SUMMARY
02/29/2024 Letter INSPECTION SUMMARY
03/21/2024 Letter INSPECTION SUMMARY
03/26/2024 Letter INSPECTION SUMMARY
03/26/2024 Letter INSPECTION SUMMARY
04/11/2024 Application Form BASEMENT FINISH APPLICATION
04/11/2024 Approved Plans APPROVED BASEMENT DRAWING
04/11/2024 Receipt Receipt for transaction:2024-002318
04/23/2024 Letter INSPECTION SUMMARY
04/23/2024 Letter INSPECTION SUMMARY
04/23/2024 Letter INSPECTION SUMMARY
04/23/2024 Letter INSPECTION SUMMARY
04/25/2024 Letter INSPECTION SUMMARY
04/25/2024 Letter INSPECTION SUMMARY
04/30/2024 Letter INSPECTION SUMMARY
04/30/2024 Letter INSPECTION SUMMARY
04/30/2024 Letter INSPECTION SUMMARY
04/30/2024 Letter INSPECTION SUMMARY
04/30/2024 Letter INSPECTION SUMMARY
05/02/2024 Letter INSPECTION SUMMARY
05/02/2024 Letter INSPECTION SUMMARY
05/02/2024 Letter INSPECTION SUMMARY
05/08/2024 Engineer Report/Study OS 47 - FIELD ISSUE LETTER - 240506
05/08/2024 Letter INSPECTION SUMMARY
05/14/2024 Letter INSPECTION SUMMARY
05/14/2024 Letter INSPECTION SUMMARY
05/14/2024 Letter INSPECTION SUMMARY
05/15/2024 Letter INSPECTION SUMMARY
05/20/2024 Letter INSPECTION SUMMARY
05/20/2024 Letter INSPECTION SUMMARY
06/28/2024 Letter INSPECTION SUMMARY
06/28/2024 Letter INSPECTION SUMMARY
07/02/2024 Letter INSPECTION SUMMARY
07/08/2024 Letter INSPECTION SUMMARY
07/09/2024 Letter INSPECTION SUMMARY
07/10/2024 Receipt Receipt for transaction:2024-005663
07/11/2024 Letter INSPECTION SUMMARY
07/11/2024 Letter INSPECTION SUMMARY
07/11/2024 Letter INSPECTION SUMMARY
07/11/2024 Letter INSPECTION SUMMARY
07/11/2024 Letter INSPECTION SUMMARY
07/11/2024 Letter INSPECTION SUMMARY
07/11/2024 Receipt Receipt for transaction:2024-005741
07/12/2024 Letter INSPECTION SUMMARY
07/16/2024 Letter INSPECTION SUMMARY
07/16/2024 Certificate/License Codes Temporary Certificate of Occupancy
07/16/2024 Receipt Receipt for transaction:2024-005847
08/15/2024 Letter INSPECTION SUMMARY
08/15/2024 Letter INSPECTION SUMMARY
08/15/2024 Letter Codes 10 Day Letter
08/19/2024 OS #47 - TCO Extension
08/20/2024 Plot Plan APPROVED AS BUILT PLOT PLAN
08/21/2024 Letter INSPECTION SUMMARY
08/21/2024 Letter Codes 10 Day Letter
08/21/2024 Letter INSPECTION SUMMARY
08/21/2024 APPROVED AS BUILT PLOT PLAN
08/22/2024 OS 47 TCOExtension Request Form 8_22
08/23/2024 Letter INSPECTION SUMMARY
09/11/2024 Certificate/License Codes Temporary Certificate of Occupancy
09/11/2024 Receipt Receipt for transaction:2024-007599
09/12/2024 Letter INSPECTION SUMMARY
09/12/2024 Letter INSPECTION SUMMARY
09/12/2024 Letter INSPECTION SUMMARY
09/16/2024 Letter Field Certificate of Occupancy
09/16/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home