Permit Application Status

PRRES20234774


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20234774
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW 3 OR 4 FAMILY
NEW MULTIUNIT HOUSE. ROOF TRUSSES. FINISHED/UNFINISHED BASEMENTS. STOP WORK ORDER generated on 01/30/2024 12:00 AM by username 'Kyle Beard'. STOP WORK ORDER removed on 01/31/2024 12:00 AM by username 'Kyle Beard'. STOP WORK ORDER generated on 04/25/2024 12:00 AM by username 'Dustin Agcopra'. STOP WORK ORDER removed on 04/25/2024 12:00 AM by username 'Dustin Agcopra'.
09/20/2023
10/05/2023
03/25/2024
09/03/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
JASONH@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New 3 or 4 Family $4,448.75 $4,448.75 Paid 10/05/2023
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/05/2023
7232302-Residential Excise Tax Fee $2,480.64 $2,480.64 Paid 10/05/2023
8331401-Water Tap Fee $15,040.00 $15,040.00 Paid 10/05/2023
8350015-Water Meter Fee $2,721.84 $2,721.84 Paid 10/05/2023
8331507-Sanitary Sewer Development Fee $8,636.00 $8,636.00 Paid 10/05/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 02/02/2024
9110080-3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 03/25/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/25/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 09/03/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 09/03/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 09/03/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 09/03/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 09/03/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/2/2023 11/02/2023
Miscellaneous Correction
Informational
11/02/2023
Inspected by third party. Notes on Ufer locations are on third party inspection report. Piers were not noted in report.
Sewer Service Inspection - R Partial 11/8/2023 (10:45) 11/8/2023 11/08/2023
Miscellaneous Correction
Corrective Action Required
11/08/2023
3734 sewer passed. This is a partial pass only. Other units will be inspected at a later date
Water Service Inspection - R Partial 11/9/2023 11/09/2023
Miscellaneous Correction
Informational
11/09/2023
3734 passed water. This is a partial pass only, other units will be called in at a later date
Sewer Service Inspection - R Partial 11/9/2023 11/09/2023
Miscellaneous Correction
Corrective Action Required
11/08/2023
3734 sewer passed. This is a partial pass only. Other units will be inspected at a later date
Miscellaneous Correction
Informational
11/09/2023
3736 and 3738 sewer both passed. This is a partial pass only, 3740 will be called in at a later date
Water Service Inspection - R Partial 11/10/2023 11/10/2023 11/10/2023
Miscellaneous Correction
Informational
11/09/2023
3734 passed water. This is a partial pass only, other units will be called in at a later date
Miscellaneous Correction
Informational
11/10/2023
3736 and 3738 both passed. This is a partial pass only
Sewer Service Inspection - R Passed 11/10/2023 11/10/2023
Miscellaneous Correction
Corrective Action Required
11/09/2023
3734 sewer passed. This is a partial pass only. Other units will be inspected at a later date
Miscellaneous Correction
Informational
11/09/2023
3736 and 3738 sewer both passed. This is a partial pass only, 3740 will be called in at a later date
Water Service Inspection - R Passed 11/13/2023 11/13/2023
Miscellaneous Correction
Informational
11/10/2023
3734 passed water. This is a partial pass only, other units will be called in at a later date
Miscellaneous Correction
Informational
11/10/2023
3736 and 3738 both passed. This is a partial pass only
Underslab Plumbing Inspection - Residential Failed 11/14/2023 11/14/2023 11/14/2023
Miscellaneous Correction
Corrective Action Required
11/14/2023
2 inch drain in 3736 by garage wall is not fully supported underneath by gravel
Erosion Control Inspection Residential Failed 11/14/2023 11/14/2023
Miscellaneous Correction
Corrective Action Required
11/14/2023
Some erosion control is missing, torn down or not installed. Full erosion control must be maintained until CofO.
Underslab Electrical Inspection - Residential Not Ready 11/14/2023 11/14/2023
Miscellaneous Correction
Corrective Action Required
11/14/2023
Underground pipe is not fully installed. Inspection was called in before job was completed. Not ready
Underslab Plumbing Inspection - Residential Passed 11/15/2023 11/15/2023 11/15/2023
Miscellaneous Correction
Resolved
11/15/2023
2 inch drain in 3736 by garage wall is not fully supported underneath by gravel
Underslab Electrical Inspection - Residential Failed 11/15/2023 11/15/2023 11/15/2023
Miscellaneous Correction
Partial Correction
11/15/2023
Underground pipe is not fully installed. Inspection was called in before job was completed. Not ready
Miscellaneous Correction
Corrective Action Required
11/15/2023
Under the slab electrical passed, but the exterior electrical conduit needs to go vertical and extend pass ground grade. Okay to pour concrete slab floor 11/15/23 KBEARD
Erosion Control Inspection Residential Failed 11/16/2023 11/16/2023
Miscellaneous Correction
Corrective Action Required
11/14/2023
Some erosion control is missing, torn down or not installed. Full erosion control must be maintained until CofO.
Miscellaneous Correction
Corrective Action Required
11/16/2023
Full property erosion control is still missing. Gravel is now spreading through the street. Immediate attention is needed. Street needs to be swept. Full erosion control is required until CofO.
Underslab Electrical Inspection - Residential Passed 11/22/2023 11/22/2023 11/22/2023
Miscellaneous Correction
Resolved
11/22/2023
Underground pipe is not fully installed. Inspection was called in before job was completed. Not ready
Miscellaneous Correction
Resolved
11/22/2023
Under the slab electrical passed, but the exterior electrical conduit needs to go vertical and extend pass ground grade. Okay to pour concrete slab floor 11/15/23 KBEARD
All Rough Inspection - Residential Partial 1/18/2024 1/18/2024 01/18/2024
Miscellaneous Correction
Informational
01/18/2024
Portal inspections passed. Okay to cover
Rated Assembly Inspection Failed 1/26/2024 1/26/2024 01/26/2024
Miscellaneous Correction
Corrective Action Required
01/26/2024
3736 North dining room fire wall needs to be blocked 10 feet on center vertically
Electrical Service Inspection Failed 1/26/2024 1/26/2024 01/26/2024
Miscellaneous Correction
Corrective Action Required
01/26/2024
3738 Jumper wire is missing from neutral to ground bus bar
Gas Service Inspection - Residential Failed 1/26/2024 1/26/2024 01/26/2024
Miscellaneous Correction
Corrective Action Required
01/26/2024
3734 Gas line does not have the bonding wire attached 3740 Gas gauge is at 0 PSI
All Rough Inspection - Residential Failed 1/26/2024 1/26/2024 01/26/2024
Miscellaneous Correction
Informational
01/18/2024
Portal inspections passed. Okay to cover
Miscellaneous Correction
Corrective Action Required
01/26/2024
3740 SW Maryville. All rough -Front porch trusses do not have tie downs installed -Bathroom 2 needs a taller nail plate at plumbing on west wall bottom plate -Bedroom 1 needs a top plate fire blocked at entry into the main part of the bedroom -Top plate in bedroom 2 on east outside wall has a larger then 1/4 gap -Vent fan to vent pipe in basement bathroom is not connected -Gas pressure gauge is at 0 3738 - front porch tie down at ceiling rafters could not be verified due to being covered with sheeting -Bathroom 2 needs a taller nail plate installed at plumbing west wall at bottom plate -Top plate in closet of bedroom 2 needs to be fire blocked -Fire blocking missing above I beam between bedroom 3 and bathroom 3 -Jumper wire is missing from neutral to ground bus bar 3736 -Two ceiling joists in garage has been over cut at the top to allow drain waste line -One air supply line in garage ceiling is not braced every 10 feet -Front porch tie down at ceiling rafters could not be verified due to being covered with sheeting -2x4 in ceiling joist space in entry is laying in electrical lines -North dining room fire wall needs to be blocked 10 feet on center vertically -LIB in bathroom 2 is missing nails -BOCA plate is needed in bathroom 2 at sole plate for plumbing along west wall -Top plate fire blocking is needed in bedroom 2 to closet of bedroom 1 -Top plate is not over lapping at corner in bedroom 2 to closet of bedroom 1 -Nails are missing in joist hanger in ceiling of bedroom 1 -Fire block is broken out in basement hallway ceiling above I beam 3734 -supply vent in garage ceiling to upstairs needs to be sealed -Front porch ceiling to rafter connection could be be verified due to sheeting being installed -Provide information on truss tie down screws that are grey in color -Nail interior corner of dining room (N/W) to code -BOCA plate needed in bathroom 2 at DEV line -Attic access has a vent line running through the opening -Gas line does not have the bonding wire attached
Erosion Control Inspection Residential Failed 1/26/2024 01/26/2024
Miscellaneous Correction
Corrective Action Required
11/16/2023
Some erosion control is missing, torn down or not installed. Full erosion control must be maintained until CofO.
Miscellaneous Correction
Corrective Action Required
11/16/2023
Full property erosion control is still missing. Gravel is now spreading through the street. Immediate attention is needed. Street needs to be swept. Full erosion control is required until CofO.
Miscellaneous Correction
Corrective Action Required
01/26/2024
Full erosion control is missing or damaged and is not effective. Streets have mud and gravel in the street and needs immediate attention so harm does not occur to pedestrians. Clean streets immediately before stop work order is issued. 01/26/2024 K.Beard 11:30am
All Rough Inspection - Residential Failed 1/30/2024 1/31/2024 01/31/2024
Miscellaneous Correction
Informational
01/26/2024
Portal inspections passed. Okay to cover
Miscellaneous Correction
Resolved
01/31/2024
3740 SW Maryville. All rough -Front porch trusses do not have tie downs installed -Bathroom 2 needs a taller nail plate at plumbing on west wall bottom plate -Bedroom 1 needs a top plate fire blocked at entry into the main part of the bedroom -Top plate in bedroom 2 on east outside wall has a larger then 1/4 gap -Vent fan to vent pipe in basement bathroom is not connected -Gas pressure gauge is at 0 3738 - front porch tie down at ceiling rafters could not be verified due to being covered with sheeting -Bathroom 2 needs a taller nail plate installed at plumbing west wall at bottom plate -Top plate in closet of bedroom 2 needs to be fire blocked -Fire blocking missing above I beam between bedroom 3 and bathroom 3 -Jumper wire is missing from neutral to ground bus bar 3736 -Two ceiling joists in garage has been over cut at the top to allow drain waste line -One air supply line in garage ceiling is not braced every 10 feet -Front porch tie down at ceiling rafters could not be verified due to being covered with sheeting -2x4 in ceiling joist space in entry is laying in electrical lines -North dining room fire wall needs to be blocked 10 feet on center vertically -LIB in bathroom 2 is missing nails -BOCA plate is needed in bathroom 2 at sole plate for plumbing along west wall -Top plate fire blocking is needed in bedroom 2 to closet of bedroom 1 -Top plate is not over lapping at corner in bedroom 2 to closet of bedroom 1 -Nails are missing in joist hanger in ceiling of bedroom 1 -Fire block is broken out in basement hallway ceiling above I beam 3734 -supply vent in garage ceiling to upstairs needs to be sealed -Front porch ceiling to rafter connection could be be verified due to sheeting being installed -Provide information on truss tie down screws that are grey in color -Nail interior corner of dining room (N/W) to code -BOCA plate needed in bathroom 2 at DEV line -Attic access has a vent line running through the opening -Gas line does not have the bonding wire attached
Miscellaneous Correction
Corrective Action Required
01/31/2024
3740 SW Maryville. All rough (2) Can not verify front porch rafter tie down due to sheeting covering it Bathroom 2 needs a taller nail plate at plumbing on west wall bottom plate 3738 front porch tie down at ceiling rafters could not be verified due to being covered with sheeting Bathroom 2 needs a taller nail plate installed at plumbing west wall at bottom plate Fire blocking missing above I beam between bedroom 3 and bathroom 3 3736 Front porch tie down at ceiling rafters could not be verified due to being covered with sheeting BOCA plate is needed in bathroom 2 at sole plate for plumbing along west wall Fire block is broken out in basement hallway ceiling above I beam 3734 Front porch ceiling to rafter connection could be be verified due to sheeting being installed Provide information on truss tie down screws that are grey in color BOCA plate needed in bathroom 2 at DEV line Attic access has a vent line running through the opening
Driveway Inspection Partial 1/31/2024 1/31/2024 01/31/2024
Misc
Informational
01/31/2024
1-31-24 Dustin A, This is for units 3740,3738,3736, and 3734 Dw is formed. Aggregate is compacted. Depth is in compliance, Approved to pour
Gas Service Inspection - Residential Passed 2/2/2024 2/1/2024 02/01/2024
Miscellaneous Correction
Resolved
02/01/2024
3734 Gas line does not have the bonding wire attached 3740 Gas gauge is at 0 PSI
Electrical Service Inspection Passed 2/2/2024 2/1/2024 02/01/2024
Miscellaneous Correction
Resolved
02/01/2024
3738 Jumper wire is missing from neutral to ground bus bar
Rated Assembly Inspection Passed 2/2/2024 2/1/2024 02/01/2024
Miscellaneous Correction
Resolved
02/01/2024
3736 North dining room fire wall needs to be blocked 10 feet on center vertically
All Rough Inspection - Residential Passed 2/2/2024 2/2/2024 02/02/2024
Miscellaneous Correction
Informational
01/31/2024
Portal inspections passed. Okay to cover
Miscellaneous Correction
Corrective Action Required
01/31/2024
3740 SW Maryville. All rough (3) Bathroom 2 needs a taller nail plate at plumbing on west wall bottom plate 3738 Bathroom 2 needs a taller nail plate installed at plumbing west wall at bottom plate 3736 BOCA plate is needed in bathroom 2 at sole plate for plumbing along west wall 3734 BOCA plate needed in bathroom 2 at DEV line
Driveway Inspection Passed 2/7/2024 2/7/2024 02/06/2024
Misc
Informational
01/31/2024
1-31-24 Dustin A, This is for units 3740,3738,3736, and 3734 Dw is formed. Aggregate is compacted. Depth is in compliance, Approved to pour 2-6-24 Dustin A, DW's are poured. Slopes are in compliance . Passed
Erosion Control Inspection Residential Partial 2/7/2024 02/07/2024
Miscellaneous Correction
Resolved
02/07/2024
Some erosion control is missing, torn down or not installed. Full erosion control must be maintained until CofO.
Miscellaneous Correction
Resolved
02/07/2024
Full property erosion control is still missing. Gravel is now spreading through the street. Immediate attention is needed. Street needs to be swept. Full erosion control is required until CofO.
Miscellaneous Correction
Resolved
02/07/2024
Full erosion control is missing or damaged and is not effective. Streets have mud and gravel in the street and needs immediate attention so harm does not occur to pedestrians. Clean streets immediately before stop work order is issued. 01/26/2024 K.Beard 11:30am
Miscellaneous Correction
Resolved
02/07/2024
Street has mud and gravel in it creating a hazard. Full erosion control is needed along with the street being cleaned. Stop work order is issued on this property.
Miscellaneous Correction
Informational
02/07/2024
Property erosion control is in place. Full erosion control must be maintained until CofO
Rated Assembly Inspection Partial 2/8/2024 02/08/2024
Miscellaneous Correction
Informational
02/08/2024
3740 Fire separation wall passed screw pattern 3738 Fire separation wall on both sides passed screw pattern This is a partial pass only. Other units will be scheduled at a later date
Rated Assembly Inspection Passed 2/9/2024 2/9/2024 02/09/2024
Miscellaneous Correction
Informational
02/08/2024
3740 Fire separation wall passed screw pattern 3738 Fire separation wall on both sides passed screw pattern This is a partial pass only. Other units will be scheduled at a later date
Miscellaneous Correction
Informational
02/09/2024
All units passed for screw pattern
Piers/Caissons Inspection - Residential Partial 2/20/2024 2/20/2024 02/20/2024
Miscellaneous Correction
Informational
02/20/2024
Piers for back deck at 3740 passed. Other piers will be scheduled at a later date. This is a partial pass only
Piers/Caissons Inspection - Residential Partial 2/21/2024 2/21/2024 02/21/2024
Miscellaneous Correction
Informational
02/20/2024
Piers for back deck at 3740 passed. Other piers will be scheduled at a later date. This is a partial pass only
Miscellaneous Correction
Informational
02/21/2024
3738 back deck piers passed. So far 3738 and 3740 piers are the only ones that have passed inspection. Other piers will be scheduled at a later date. This is a partial pass only.
Sidewalk Inspection Partial 2/23/2024 2/23/2024 02/23/2024
Misc
Informational
02/23/2024
2-22-24 Dustin A, Sw is formed and aggregate is compacted. Slopes are to spec approved to pour
Piers/Caissons Inspection - Residential Partial 2/23/2024 2/23/2024 02/23/2024
Miscellaneous Correction
Informational
02/21/2024
Piers for back deck at 3740 passed. Other piers will be scheduled at a later date. This is a partial pass only
Miscellaneous Correction
Informational
02/21/2024
3738 back deck piers passed. So far 3738 and 3740 piers are the only ones that have passed inspection. Other piers will be scheduled at a later date. This is a partial pass only.
Miscellaneous Correction
Informational
02/23/2024
Piers passed for 3740, 3738 and 3736. Last pier will be scheduled for inspection at a later date. This is a partial pass only.
Piers/Caissons Inspection - Residential Passed 2/26/2024 2/26/2024 02/26/2024
Miscellaneous Correction
Informational
02/23/2024
Piers for back deck at 3740 passed. Other piers will be scheduled at a later date. This is a partial pass only
Miscellaneous Correction
Informational
02/23/2024
3738 back deck piers passed. So far 3738 and 3740 piers are the only ones that have passed inspection. Other piers will be scheduled at a later date. This is a partial pass only.
Miscellaneous Correction
Informational
02/23/2024
Piers passed for 3740, 3738 and 3736. Last pier will be scheduled for inspection at a later date. This is a partial pass only.
Sidewalk Inspection Passed 3/11/2024 3/11/2024 03/11/2024
Misc
Informational
03/11/2024
3-1-24 PS Sidewalk meets ADA and LS specs
Occupancy Inspection - Codes Residential Failed 3/14/2024 3/14/2024 03/14/2024
Misc
Informational
03/14/2024
-Unit 3740 TCO Passed, exterior not ready needs sod, splash blocks
Occupancy Inspection - Codes Residential Failed 3/15/2024 3/15/2024 03/15/2024
Misc
Informational
03/14/2024
-Unit 3740 TCO Passed, exterior not ready needs sod, splash blocks
Miscellaneous Correction
Corrective Action Required
03/15/2024
3738 SW Maryville. Occupancy -Front porch has a drop off of over 30 inches in height and needs fall protection installed —Seal penetrations in garage at ceiling Security light on back patio does not meet the 8 foot height requirement -Refrigerator and microwave need to be on a AFCI breaker -Exterior was not ready for inspection
Occupancy Inspection - Codes Residential Failed 3/19/2024 3/19/2024 03/19/2024
Misc
Informational
03/15/2024
-Unit 3740 TCO Passed, exterior not ready needs sod, splash blocks
Miscellaneous Correction
Resolved
03/19/2024
3738 SW Maryville. Occupancy -Front porch has a drop off of over 30 inches in height and needs fall protection installed —Seal penetrations in garage at ceiling Security light on back patio does not meet the 8 foot height requirement -Refrigerator and microwave need to be on a AFCI breaker -Exterior was not ready for inspection
Miscellaneous Correction
Informational
03/19/2024
3738 SW Maryville. Occupancy (2) -Front porch has a drop off of over 30 inches in height and needs fall protection installed -Exterior was not ready for inspection Passed for TCO only 3738 and 3740 SW Maryville both have passed for TCO only
Occupancy Inspection - Codes Residential Failed 3/20/2024 3/20/2024 03/20/2024
Misc
Informational
03/19/2024
-Unit 3740 TCO Passed, exterior not ready needs sod, splash blocks
Miscellaneous Correction
Informational
03/19/2024
3738 SW Maryville. Occupancy (2) -Front porch has a drop off of over 30 inches in height and needs fall protection installed -Exterior was not ready for inspection Passed for TCO only 3738 and 3740 SW Maryville both have passed for TCO only
Miscellaneous Correction
Corrective Action Required
03/20/2024
3736 SW Maryville. Occupancy Microwave and refrigerator bowed to have AFCI breakers installed 3734 garage to house self closing door will not fully shut and lock Seal garage ceiling at overhead garage door hanging brackets Entry to main living area hand rail on stairs does not go down to meet the tread nosing Handrail in basement does not meet the lower tread nosing Microwave and refrigerator needs AFCI breakers installed No code violation (furnace humidifier water line is not hooked up) Exterior of both units are not ready for inspection
Occupancy Inspection - Codes Residential Ready for Temp CO 3/25/2024 3/25/2024 03/25/2024
Misc
Informational
03/20/2024
-Unit 3740 TCO Passed, exterior not ready needs sod, splash blocks
Miscellaneous Correction
Informational
03/20/2024
3738 SW Maryville. Occupancy (2) -Front porch has a drop off of over 30 inches in height and needs fall protection installed -Exterior was not ready for inspection Passed for TCO only 3738 and 3740 SW Maryville both have passed for TCO only
Miscellaneous Correction
Resolved
03/25/2024
3736 SW Maryville. Occupancy Microwave and refrigerator bowed to have AFCI breakers installed 3734 garage to house self closing door will not fully shut and lock Seal garage ceiling at overhead garage door hanging brackets Entry to main living area hand rail on stairs does not go down to meet the tread nosing Handrail in basement does not meet the lower tread nosing Microwave and refrigerator needs AFCI breakers installed No code violation (furnace humidifier water line is not hooked up) Exterior of both units are not ready for inspection
Miscellaneous Correction
Corrective Action Required
03/25/2024
All units have passed for TCO only All units still need sod, splash pads and sump pump extensions installed
Plot Plan Inspection Failed 4/15/2024 04/15/2024
Miscellaneous Correction
Corrective Action Required
04/15/2024
-As built plot plan is required before sodding -Final grading is not completed -This is not a complete list
Miscellaneous Inspection Partial 4/15/2024 04/15/2024
Miscellaneous Correction
Informational
04/15/2024
Builder request a TCO extension, this is the first extension request. Request is granted First TCO expires 04/25/2024, the extension will expire 05/25/2024
Plot Plan Inspection Passed 4/24/2024 04/24/2024
Miscellaneous Correction
Resolved
04/24/2024
-As built plot plan is required before sodding -Final grading is not completed -This is not a complete list
Erosion Control Inspection Residential Passed 04/25/2024
Miscellaneous Correction
Informational
02/07/2024
Property erosion control is in place. Full erosion control must be maintained until CofO
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/25/2024
4-25-24 Dustin A, EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Full C of O 8/30/2024 9/3/2024 09/03/2024
Misc
Informational
03/25/2024
-Unit 3740 TCO Passed, exterior not ready needs sod, splash blocks
Miscellaneous Correction
Resolved
09/03/2024
3738 SW Maryville. Occupancy (2) -Front porch has a drop off of over 30 inches in height and needs fall protection installed -Exterior was not ready for inspection Passed for TCO only 3738 and 3740 SW Maryville both have passed for TCO only
Miscellaneous Correction
Resolved
09/03/2024
All units have passed for TCO only All units still need sod, splash pads and sump pump extensions installed
Erosion Control Inspection Residential Passed 9/3/2024 09/03/2024
Miscellaneous Correction
Informational
04/25/2024
Property erosion control is in place. Full erosion control must be maintained until CofO
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/25/2024
4-25-24 Dustin A, EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Documents & Images
Date Uploaded File Type Document Name
09/20/2023 OS # 15 - PERMIT APP
09/22/2023 Permit Codes Residential Plan Review
09/27/2023 Permit Codes Residential Plan Review
09/27/2023 Approved Plans APPROVED PLANS
09/28/2023 Approved Plans APPROVED TRUSS PACKAGE
09/28/2023 Approved Plans APPROVED TRUSS LAYOUT
10/04/2023 Permit Codes Residential Plan Review
10/05/2023 Permit DS Building Permit
10/05/2023 Receipt Receipt for transaction:2023-007544
10/12/2023 Plot Plan APPROVED PLOT PLAN
11/01/2023 M L Crose 3734 3736 3738 3740 SW Maryville PL LSMO Osage Lot 15 Clayton P 2023-4774 3rd Party Footing Inspection Report 11-1-23
11/02/2023 Letter INSPECTION SUMMARY
11/08/2023 Letter INSPECTION SUMMARY
11/09/2023 Letter INSPECTION SUMMARY
11/09/2023 Letter INSPECTION SUMMARY
11/10/2023 Letter INSPECTION SUMMARY
11/10/2023 Letter INSPECTION SUMMARY
11/10/2023 Letter INSPECTION SUMMARY
11/10/2023 Letter INSPECTION SUMMARY
11/13/2023 Letter INSPECTION SUMMARY
11/14/2023 Letter INSPECTION SUMMARY
11/14/2023 Letter INSPECTION SUMMARY
11/14/2023 Letter INSPECTION SUMMARY
11/15/2023 Letter INSPECTION SUMMARY
11/15/2023 Letter INSPECTION SUMMARY
11/16/2023 Letter INSPECTION SUMMARY
11/22/2023 Letter INSPECTION SUMMARY
01/08/2024 15 OSAGE LETTER
01/12/2024 I63002931_P230146-01
01/18/2024 Letter INSPECTION SUMMARY
01/26/2024 Letter INSPECTION SUMMARY
01/26/2024 Letter INSPECTION SUMMARY
01/26/2024 Letter INSPECTION SUMMARY
01/26/2024 Letter INSPECTION SUMMARY
01/26/2024 Letter INSPECTION SUMMARY
01/30/2024 Engineer Report/Study ENGINEER LETTER
01/31/2024 Letter INSPECTION SUMMARY
01/31/2024 Letter INSPECTION SUMMARY
02/01/2024 Letter INSPECTION SUMMARY
02/01/2024 Letter INSPECTION SUMMARY
02/01/2024 Letter INSPECTION SUMMARY
02/02/2024 Receipt Receipt for transaction:2024-000557
02/02/2024 Letter INSPECTION SUMMARY
02/06/2024 Letter INSPECTION SUMMARY
02/07/2024 Letter INSPECTION SUMMARY
02/08/2024 Letter INSPECTION SUMMARY
02/09/2024 Letter INSPECTION SUMMARY
02/20/2024 Letter INSPECTION SUMMARY
02/21/2024 Letter INSPECTION SUMMARY
02/23/2024 Letter INSPECTION SUMMARY
02/23/2024 Letter INSPECTION SUMMARY
02/26/2024 Letter INSPECTION SUMMARY
03/11/2024 Letter INSPECTION SUMMARY
03/14/2024 Letter INSPECTION SUMMARY
03/15/2024 Letter INSPECTION SUMMARY
03/19/2024 Letter INSPECTION SUMMARY
03/20/2024 Letter INSPECTION SUMMARY
03/25/2024 Certificate/License Codes Temporary Certificate of Occupancy
03/25/2024 Receipt Receipt for transaction:2024-001856
04/15/2024 Application Form EXTENSION REQUEST
04/15/2024 Letter INSPECTION SUMMARY
04/15/2024 Letter INSPECTION SUMMARY
04/23/2024 LOT 15 ASBUILT
04/23/2024 Plot Plan approved as graded plot plan
04/24/2024 Letter INSPECTION SUMMARY
04/25/2024 Letter Stop Work Order
04/25/2024 Letter Stop Work Order
04/25/2024 Letter INSPECTION SUMMARY
09/03/2024 Certificate/License Codes Temporary Certificate of Occupancy
09/03/2024 Certificate/License Codes Temporary Certificate of Occupancy
09/03/2024 Certificate/License Codes Temporary Certificate of Occupancy
09/03/2024 Certificate/License Codes Temporary Certificate of Occupancy
09/03/2024 Certificate/License Codes Temporary Certificate of Occupancy
09/03/2024 Receipt Receipt for transaction:2024-007413
09/03/2024 Letter Field Certificate of Occupancy
09/03/2024 Letter Codes Final Certificate of Occupancy
09/03/2024 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home