Permit Application Status

PRRES20232902


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20232902
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
06/20/2023
06/27/2023
12/24/2023
05/01/2024
Locations
Contacts
MCGRAW HOMES INC, Address:902 SE WILLOW PL, Phone:(816) 985-6909  
Chad McGraw, Address:902 SE Willow Pl  
chad@mcgraw-homes.com  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
UNITED ELECTRIC COMPANY, Address:PO BOX 723, Phone:(816) 795-2744  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 06/27/2023
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 06/27/2023
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 06/27/2023
8331401-Water Tap Fee $3,730.00 $3,730.00 Paid 06/27/2023
8350015-Water Meter Fee $550.50 $550.50 Paid 06/27/2023
9110078-Valuation Fee New Single Family $1,704.08 $1,704.08 Paid 06/27/2023
Outstanding Fees Amount Paid Owing Date Paid
9110078-Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid


$50.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Passed 7/26/2023 07/26/2023
Footing Inspection - Residential Passed 07/26/2023
Informational
07/26/2023
FOOTING APPROVED BY ENGINEER
Sewer Service Inspection - R Passed 9/1/2023 (8:15) 9/1/2023 09/01/2023
Water Service Inspection - R Passed 9/5/2023 (10:30) 9/5/2023 09/05/2023
Piers/Caissons Inspection - Residential Failed 9/13/2023 9/13/2023 09/13/2023
Misc
Corrective Action Required
09/13/2023
Dig piers down to virgin soil. Min 26" diameter holes
Piers/Caissons Inspection - Residential Passed 9/15/2023 09/15/2023
Misc
Resolved
09/15/2023
Dig piers down to virgin soil. Min 26" diameter holes
Gas Service Inspection - Residential Passed 10/2/2023 10/2/2023 10/02/2023
Electrical Service Inspection Passed 10/2/2023 10/2/2023 10/02/2023
All Rough Inspection - Residential Failed 10/2/2023 10/2/2023 10/02/2023
Misc
Corrective Action Required
10/02/2023
-Nail corner studs w/16d@12” oc or equivalent nailing throughout -Provide full support for front stoop roof beam at both ends -Provide security blockings at garage exterior door -Install stud shoe for stud bored more than 40% and protect SE cable -Complete fur out for radon pipe and Fb as required -Protect wiring at pocket office -Strap top plates lapped less than 24” at bathroom shower -Support bottom of lvl valley rafter to lvl beam with approved device -Provide full support underneath roof struts to kitchen I beam -Fb stair/garage double stud wall vertically at max ten ft interval and Fb from roof; Fb fireplace space from roof -Provide engineer address for rafter nailing to wall top plates -Install roof beam above laundry & closet area per plan. Move roof struts to beam -Brace ends of roof beam from rotation -Provide full bearing for kitchen I beam support down to grade beam. See the gaps -Fb both basement bathroom wall space from ceiling space; correct west basement wall vertical fire blocking. Insulation must be tight -Nail corner studs per code in basement -Provide 3-studs corner in basement -Provide full support for triple 2x12 beam (under fireplace) at exterior wall -Engineer to address the triple 2x12 and double 2x12 under fireplace and hallway. Plan shows lvl beams -Engineer to address the (2)2x12 under kitchen/hall bearing wall (above basement closet). Plan calls for (4)9.25” lvl beam **DO NOT INSULATE
All Rough Inspection - Residential Failed 10/3/2023 10/3/2023 10/03/2023
Misc
Corrective Action Required
10/02/2023
-Complete fur out for radon pipe and Fb as required **Fb at top -Fb stair/garage double stud wall from roof **Foam openings at top -Fb fireplace space from roof -Provide engineer address for rafter nailing to wall top plates **Is there an equivalent 4-10d toe nailing of rafter to top plate? -Install roof beam above laundry & closet area per plan. Move roof struts to beam -Fb both basement bathroom wall space from ceiling space; correct west basement wall vertical fire blocking. Insulation must be tight -Engineer to address the triple 2x12 and double 2x12 under fireplace and hallway. Plan shows lvl beams -Engineer to address the (2)2x12 under kitchen/hall bearing wall (above basement closet). Plan calls for (4)9.25” lvl beam **OK TO INSULATE
All Rough Inspection - Residential Failed 10/6/2023 10/6/2023 10/06/2023
Misc
Corrective Action Required
10/03/2023
-Install roof beam above laundry & closet area per plan. Move roof struts to beam **install (3)2x4 stud support and each end of beam, have engineer address the installed (2)2x12 beam (instead of 9.25” lvl), and move support strut to this beam -Engineer to address the triple 2x12 and double 2x12 under fireplace and hallway. Plan shows lvl beams **also there’s a single joist between I beams above hall where the plan shows double lvl beam -Engineer to address the (2)2x12 under kitchen/hall bearing wall (above basement closet). Plan calls for (4)9.25” lvl beam or I beam **OK TO INSULATE
All Rough Inspection - Residential Passed 10/9/2023 10/9/2023 10/09/2023
Misc
Resolved
10/09/2023
-Install roof beam above laundry & closet area per plan. Move roof struts to beam **install (3)2x4 stud support and each end of beam, have engineer address the installed (2)2x12 beam (instead of 9.25” lvl), and move support strut to this beam -Engineer to address the triple 2x12 and double 2x12 under fireplace and hallway. Plan shows lvl beams **also there’s a single joist between I beams above hall where the plan shows double lvl beam **OK TO INSULATE
Driveway Inspection Partial 12/7/2023 12/7/2023 12/08/2023
Misc
Informational
12/08/2023
12-7-23 NS Site visited and it appears driveway meets city standards. will come back and check in a couple weeks for forms to be pulled.
Sidewalk Inspection Partial 12/13/2023 12/13/2023 12/13/2023
Misc
Informational
12/13/2023
NS 12-13-23 Site visited for a pre-pour. it appears to pass city standards will come back after the forms are pulled.
Driveway Inspection Passed 12/18/2023 12/18/2023 12/18/2023
Misc
Informational
12/08/2023
12-7-23 NS Site visited and it appears driveway meets city standards. will come back and check in a couple weeks for forms to be pulled. 12-18-23 Dustin A, Forms pulled. Passed
Sidewalk Inspection Partial 12/18/2023 12/18/2023 12/18/2023
Misc
Informational
12/13/2023
NS 12-13-23 Site visited for a pre-pour. it appears to pass city standards will come back after the forms are pulled. 12-18-23 Dustin A, SW not poured.
Sidewalk Inspection Passed 12/27/2023 12/27/2023 12/27/2023
Misc
Informational
12/18/2023
NS 12-13-23 Site visited for a pre-pour. it appears to pass city standards will come back after the forms are pulled. 12-18-23 Dustin A, SW not poured. 12-27-23 NS Site visited and it appears that the sidewalk meets city standards and ada passed
Occupancy Inspection - Codes Residential Failed 1/24/2024 1/24/2024 01/24/2024
Misc
Corrective Action Required
01/24/2024
-Exterior not inspected at this time -Final grade, sod, downspout and sump pump extension -Seal exterior wall penetrations; seal above meter, AC disconnect, seal exterior lights, etc -Secure AC whip within 12” of disconnect -Install tamper-proof caps at AC valves -Provide sewer tracer wire port at grade -Need a receptacle for basement island
Occupancy Inspection - Codes Residential Ready for Temp CO 2/1/2024 2/1/2024 02/01/2024
Misc
Corrective Action Required
01/24/2024
-Exterior not inspected at this time -Final grade, sod, downspout and sump pump extension -Seal exterior wall penetrations; seal above meter, AC disconnect, seal exterior lights, etc -Secure AC whip within 12” of disconnect -Install tamper-proof caps at AC valves -Provide sewer tracer wire port at grade
Occupancy Inspection - Codes Residential Full C of O 5/1/2024 5/1/2024 05/01/2024
Misc
Resolved
05/01/2024
-Exterior not inspected at this time -Final grade, sod, downspout and sump pump extension -Seal exterior wall penetrations; seal above meter, AC disconnect, seal exterior lights, etc -Secure AC whip within 12” of disconnect -Install tamper-proof caps at AC valves -Provide sewer tracer wire port at grade
Documents & Images
Date Uploaded File Type Document Name
06/20/2023 Lot 390 Building Permit App
06/20/2023 Lot 390 Excise Tax App
06/20/2023 LOT 390 FINAL
06/20/2023 DW Permit Plan 2028 Lot 390 Park Ridge 1528 NE Park Springs Terr 6-20-23
06/22/2023 Permit Codes Residential Plan Review
06/22/2023 Lot 390 License Tax App
06/22/2023 Lot 390 Park Ridge Building Permit App
06/27/2023 dw permit plan 2028 lot 390 park ridge 1520 ne park springs terr 6-27-23
06/27/2023 Permit Codes Residential Plan Review
06/27/2023 LOT 390 CITY
06/27/2023 Permit Codes Residential Plan Review
06/27/2023 Permit DS Building Permit
06/27/2023 Receipt Receipt for transaction:2023-004913
07/03/2023 Wilmoth 1520 NE Park Springs Ter Pl LS MO Subgrade & Footing Inspection Report 6-30-23
07/26/2023 Letter INSPECTION SUMMARY
07/26/2023 Letter INSPECTION SUMMARY
09/01/2023 Letter INSPECTION SUMMARY
09/05/2023 Letter INSPECTION SUMMARY
09/13/2023 Letter INSPECTION SUMMARY
09/15/2023 Letter INSPECTION SUMMARY
10/02/2023 Letter INSPECTION SUMMARY
10/02/2023 Letter INSPECTION SUMMARY
10/02/2023 Letter INSPECTION SUMMARY
10/03/2023 Letter INSPECTION SUMMARY
10/06/2023 Letter INSPECTION SUMMARY
10/09/2023 Letter INSPECTION SUMMARY
12/08/2023 Letter INSPECTION SUMMARY
12/13/2023 Letter INSPECTION SUMMARY
12/18/2023 Letter INSPECTION SUMMARY
12/18/2023 Letter INSPECTION SUMMARY
12/27/2023 Letter INSPECTION SUMMARY
01/24/2024 Letter INSPECTION SUMMARY
05/01/2024 Letter Field Certificate of Occupancy
05/01/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home