Permit Application Status

PRRES20220253


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20220253
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. ROOF TRUSSES. COVERED PATIO.
01/19/2022
01/26/2022
06/15/2023
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
AJ@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $600.00 $600.00 Paid 01/26/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 01/26/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 01/26/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 01/26/2022
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 01/26/2022
9110078-Valuation Fee New Single Family $1,620.70 $1,620.70 Paid 01/26/2022
8331504-EFHB Middle Big Creek, Full $669.60 $669.60 Paid 01/26/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 11/22/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 12/14/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 01/03/2023
9110080-3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 06/12/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Passed 4/13/2022 4/13/2022 04/13/2022
Sewer Service Inspection - R Passed 6/17/2022 6/17/2022 06/17/2022
Water Service Inspection - R Passed 6/20/2022 (10:30) 6/20/2022 06/20/2022
Erosion Control Inspection Residential Failed 6/20/2022 6/20/2022 06/20/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
06/20/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Failed 9/1/2022 9/1/2022 09/01/2022
Miscellaneous Correction
Corrective Action Required
09/01/2022
No Bering for sill plate corner single garage bay Missing anchor washer and nuts garage Fire block penetrations top plate single garage bay Fire block penetration top plate garage double bay Sill plate not supported corner double bay garage at door Missing sill plate double bay garage Fire block top of all fir outs in garage Fire block soffit ends garage Support and complete gas line in flex room Solid block cantilever over windows dining room Security blocking for exterior doors Anchor steel column at first floor stairs Fire block gaps around ductwork at stairs top and bottom Fire block penetration nm bottom plate at stairs Fireplace not mounted Fire block top of chase near sliding door main floor Unable to inspect framing of patio cover Provide window bedroom 3 Fireplace upstairs not complete Fire block bottom gaps around ductwork sitting room Fire block ductwork gaps bedroom 2 Missing joist hanger basement at cantilever by electrical panel Solid block cantilever basement
Electrical Service Inspection Passed 9/23/2022 9/23/2022 09/23/2022
Gas Service Inspection - Residential Failed 9/23/2022 9/23/2022 09/23/2022
Misc
Corrective Action Required
09/23/2022
-Complete all gas lines, fireplace master bed, pressure test after all gas lines complete
All Rough Inspection - Residential Failed 9/23/2022 9/23/2022 09/23/2022
Miscellaneous Correction
Corrective Action Required
09/01/2022
-provide engineer letter on footing, only foundation engineer report provided -Fire block penetrations top plate single garage bay -Fire block penetration top plate garage double bay -fireblock plumbing fur outs garage -Fire block fur down soffit ends garage -Support and complete gas line in flex room -provide joist hangers at joist to header connection HVAC chase garage wall -nail off joist hangers throughout -address dbl 2x10 overbored fand bored less than 2” from end of header for HVAC duct at kitchen load bearing wall -fireblock vertical to horizontal at chase great room windows -Fire block gaps around ductwork at stairs top and bottom -Fire block penetration nm bottom plate at stairs -Fire block top of chase near sliding door main floor -Unable to inspect framing of patio cover (remove cover for inspection at rear, on front covered porch plans state 2x10 ridge, support ridge both ends, provide ridge straps, install joist hangers at rafters toe nailed to ledger) -Fireplace master bed not complete -Fire block bottom gaps around ductwork sitting room -Fire block ductwork gaps bedroom 2 -solid block all sheathing breaks front entry wall -continuous studs front entry walls -snow block 2nd floor East bed -address dbl 2x10 cut for HVAC above furnace
Footing Inspection - Residential Passed 10/18/2022 10/18/2022 10/18/2022
Misc
Corrective Action Required
10/18/2022
FOOTING APPROVED PER BRADLEY HUXOL 3/9/22
Gas Service Inspection - Residential Passed 10/18/2022 10/18/2022 10/18/2022
Misc
Resolved
10/18/2022
All Rough Inspection - Residential Not Ready 10/18/2022 10/18/2022 10/18/2022
Miscellaneous Correction
Corrective Action Required
09/23/2022
10/18/22 - NOT READY FOR INSPECTION, ADDRESS ALL CORRECTIONS BEFORE REINSPECTION -Fire block penetrations top plate single garage bay (not addressed) -Fire block penetration top plate garage double bay (not addressed) -nail off joist hangers throughout (not addressed) -address dbl 2x10 overbored and bored less than 2” from end of header for HVAC duct at kitchen load bearing wall (not addressed) -fireblock vertical to horizontal at chase great room windows (not addressed) -Unable to inspect framing of patio cover (remove cover for inspection at rear, on front covered porch plans state 2x10 ridge, support ridge both ends, provide ridge straps, install joist hangers at rafters toe nailed to ledger) (covered at reinspect not addressed) -continuous studs front entry walls (not addressed) -Seal floor penetration at master bed fireplace -address dbl 2x10 cut for HVAC above furnace (not addressed)
Occupancy Inspection - Codes Residential Failed 11/23/2022 11/23/2022 11/23/2022
Misc
Corrective Action Required
11/23/2022
NOT READY FOR AN OCCUPANCY INSPECTION
All Rough Inspection - Residential Failed 11/28/2022 11/28/2022 11/28/2022
Miscellaneous Correction
Corrective Action Required
10/18/2022
-Unable to inspect framing of front porch (remove cover for inspection,front covered porch plans state 2x10 ridge, support ridge both ends, provide ridge straps, install joist hangers at rafters toe nailed to ledger) (covered at reinspect not addressed) -address dbl 2x10 cut for HVAC above furnace (run and secure moved electrical behind header)
Driveway Inspection Partial 12/15/2022 12/15/2022 12/15/2022
Misc
Informational
12/15/2022
12-15-22 RH. Driveway is formed up and aggregate is placed and compacted. Contractor is planning to pour approach at 2pm. They were informed they cannot pour approach with frozen Subgrade and may have to blanket approach to get temperatures. Contractor had blankets to cover concrete.
All Rough Inspection - Residential Not Ready 12/19/2022 12/19/2022 12/19/2022
Miscellaneous Correction
Corrective Action Required
11/28/2022
12/19/22 - HOUSE HAS BEEN INSULATED WITHOUT APPROVAL, NOTE THAT INSULATION AND ROCK ARE NOT ALLOWED BEFORE PASS OF ALL ROUGH INSPECTION OR APPROVAL FROM THE BUILDING INSPECTIOR, THIS IS NOW THE 5TH ALL ROUGH INSPECTION PERFORMED ON THIS HOUSE, FEES ADDED, DO NOT ROCK -Unable to inspect framing of front porch (remove cover for inspection,front covered porch plans state 2x10 ridge, support ridge both ends, provide ridge straps, install joist hangers at rafters toe nailed to ledger) COVER HAS BEEN REMOVED, ROOF FRAMING NOT TO ENGINEERED PLANS
Driveway Inspection Partial 12/22/2022 12/22/2022 12/27/2022
Misc
Informational
12/15/2022
12-15-22 RH. Driveway is formed up and aggregate is placed and compacted. Contractor is planning to pour approach at 2pm. They were informed they cannot pour approach with frozen Subgrade and may have to blanket approach to get temperatures. Contractor had blankets to cover concrete. 12-27-22 RH. Driveway meets LS specification.
All Rough Inspection - Residential Failed 1/4/2023 1/4/2023 01/04/2023
Miscellaneous Correction
Corrective Action Required
12/19/2022
-REPLACE LIGHT BOX AND LAND NM AT FRONT COVERED PORCH REMOVED FOR FRAMING CORRECTION, SEE HANGING NM ON INTERIOR SIDE OF DOOR FRONT ENTRY
All Rough Inspection - Residential Passed 6/6/2023 06/06/2023
Miscellaneous Correction
Resolved
06/06/2023
-REPLACE LIGHT BOX AND LAND NM AT FRONT COVERED PORCH REMOVED FOR FRAMING CORRECTION, SEE HANGING NM ON INTERIOR SIDE OF DOOR FRONT ENTRY
Occupancy Inspection - Codes Residential Failed 6/6/2023 6/6/2023 06/06/2023
Misc
Resolved
06/06/2023
NOT READY FOR AN OCCUPANCY INSPECTION
Miscellaneous Correction
Corrective Action Required
06/06/2023
- Vertical boards in the garage above the overhead doors need to be sealed - Basement a/c supply duct has two broken support hangers - One 2 inch plumbing line in basement has the support hangers upside down - Hot water line in the basement along the west wall is not within its support bracket - Smoke detector in basement still has a cover on it - Sump pump discharge pipe is not attached outside - More gravel is needed in the escape exit window well. Gravel to ladder rung is over 18 inches in height - Address numbers are not close enough to the exterior light to be properly illuminated - Sod netting is covering the irrigation system bases and water meter and could not be inspected
Occupancy Inspection - Codes Residential Failed 6/9/2023 6/9/2023 06/09/2023
Miscellaneous Correction
Corrective Action Required
06/06/2023
- Vertical boards in the garage above the overhead doors need to be sealed - Hot water line in the basement along the west wall is not within its support bracket - Sod netting is covering the water meter and could not be inspected 06/09/2023 - Top of a/c disconnect outside is not sealed (missed on initial inspection) - Irrigation permit is required for system already installed - Driveway final inspection was never passed - pay all outstanding fees associated with permit
Plot Plan Inspection Passed 6/9/2023 06/09/2023
Erosion Control Inspection Residential Passed 6/9/2023 06/09/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
06/20/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Piers/Caissons Inspection - Residential Passed 6/9/2023 06/09/2023
Miscellaneous Correction
Informational
06/09/2023
Third party signed off on piers 03/25/2022
Occupancy Inspection - Codes Residential Failed 6/14/2023 6/14/2023 06/14/2023
Miscellaneous Correction
Corrective Action Required
06/09/2023
06/14/2023 - Irrigation permit is required for system already installed - Driveway final inspection was never passed (must be completed) - pay all outstanding fees ( if any) associated with permit
Driveway Inspection Passed 6/14/2023 6/14/2023 06/14/2023
Misc
Informational
12/27/2022
12-15-22 RH. Driveway is formed up and aggregate is placed and compacted. Contractor is planning to pour approach at 2pm. They were informed they cannot pour approach with frozen Subgrade and may have to blanket approach to get temperatures. Contractor had blankets to cover concrete. 12-27-22 RH. Driveway meets LS specification. 6-14-23 BR Driveway is concreted to LS specification.
Occupancy Inspection - Codes Residential Full C of O 6/15/2023 6/15/2023 06/15/2023
Miscellaneous Correction
Resolved
06/15/2023
06/14/2023 - Irrigation permit is required for system already installed - Driveway final inspection was never passed (must be completed) - pay all outstanding fees ( if any) associated with permit
Documents & Images
Date Uploaded File Type Document Name
01/19/2022 RR #103 - PERMIT APP
01/24/2022 Approved Plans APPROVED DRAWINGS
01/24/2022 Approved Plans APPROVED TRUSS LAYOUT
01/24/2022 Approved Plans APPROVED TRUSS PACKAGE
01/24/2022 Plot Plan APPROVED PLOT PLAN
01/24/2022 Permit Codes Residential Plan Review
01/26/2022 Permit DS Building Permit
01/26/2022 Receipt Receipt for transaction:2022-000443
04/12/2022 103 Reserve at Stoney Creek FDTN
04/12/2022 103 Reserve at Stoney Creek FDTN
04/13/2022 Letter INSPECTION SUMMARY
06/17/2022 Letter INSPECTION SUMMARY
06/20/2022 Letter INSPECTION SUMMARY
06/20/2022 Letter INSPECTION SUMMARY
09/01/2022 Letter INSPECTION SUMMARY
09/23/2022 Letter INSPECTION SUMMARY
09/23/2022 Letter INSPECTION SUMMARY
09/23/2022 Letter INSPECTION SUMMARY
10/10/2022 103 Reserve at Stoney Creek FTNG
10/18/2022 Letter INSPECTION SUMMARY
10/18/2022 Letter INSPECTION SUMMARY
10/18/2022 Letter INSPECTION SUMMARY
11/22/2022 Receipt Receipt for transaction:2022-009103
11/23/2022 Letter INSPECTION SUMMARY
11/28/2022 Letter INSPECTION SUMMARY
12/14/2022 Receipt Receipt for transaction:2022-009501
12/15/2022 Letter INSPECTION SUMMARY
12/19/2022 Letter INSPECTION SUMMARY
12/27/2022 Letter INSPECTION SUMMARY
01/03/2023 Receipt Receipt for transaction:2023-000012
05/24/2023 Letter Codes 140 Day Letter
06/06/2023 Letter INSPECTION SUMMARY
06/06/2023 Letter INSPECTION SUMMARY
06/09/2023 Letter INSPECTION SUMMARY
06/09/2023 Letter INSPECTION SUMMARY
06/09/2023 Letter INSPECTION SUMMARY
06/09/2023 Letter INSPECTION SUMMARY
06/12/2023 Receipt Receipt for transaction:2023-004266
06/14/2023 Letter INSPECTION SUMMARY
06/14/2023 Letter INSPECTION SUMMARY
06/15/2023 Letter Codes Final Certificate of Occupancy
06/15/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home