Permit Application Status

PRRES20220238


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20220238
Building Permit - Residential
Certificate of Occupancy
FROEHLICH CONSTRUCTION LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK - SUSPENDED SLAB
01/19/2022
02/14/2022
07/19/2022
07/06/2023
Locations
Contacts
KC CUSTOM HOMES, Address:406 NW DONOVAN RD, Phone:(816) 564-5149  
FROEHLICH CONSTRUCTION LLC, Address:209 SW LEWIS CT  
Steve Froehlich, Address:406 NW Donovan Rd  
GREEN FIELD ENERGY GROUP INC, Address:5 SW 4TH ST, Phone:(816) 524-5616  
THE SOLAR GUYS, Address:6114 MO-9 HWY STE C1, Phone:(913) 424-2112  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,244.63 $1,244.63 Paid 02/14/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 02/14/2022
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 02/14/2022
8331507-Sewer Connection Fee $450.00 $450.00 Paid 02/14/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 02/14/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 02/14/2022
9110078-Valuation Fee New Single Family $61.19 $61.19 Paid 05/12/2023
$1,305.82
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/31/2022 (2:30) 3/31/2022 03/31/2022
Misc
Informational
03/31/2022
Ufer located south foundation wall about 3' from front of house
Sewer Service Inspection - R Passed 4/21/2022 (10:30) 4/21/2022 04/21/2022
Water Service Inspection - R Passed 04/22/2022
Underslab Plumbing Inspection - Residential Passed 5/9/2022 5/9/2022 05/09/2022
Erosion Control Inspection Residential Failed 5/9/2022 05/09/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/09/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER CLEAN STREET
Piers/Caissons Inspection - Residential Passed 5/31/2022 05/31/2022
Misc
Informational
05/31/2022
3RD PARTY BY CHRISTOPHER VEITH @ APEX SIGNED AND SEALED BY CLAYTON HESS STRUCTURAL BASEMENT OVERDIG & DECK PIERS (3) 24x36
All Rough Inspection - Residential Failed 12/28/2022 12/28/2022 12/28/2022
Misc
Corrective Action Required
12/28/2022
-uncover pfh exterior nailing to header for inspection -missing washer and nut at anchor bolts for pfh -nail all exterior wall corners to code -complete all bath fans -fireblock mast closet N wall to ceiling space -fireblock master bath N wall to ceiling space -over notched lvl ridge NE master bed -fire block fire place to ceiling space left side -provide straps at covered deck structural ridge per plans -fireblock N living room wall to ceiling space -fireblock dead space to ceiling space at kitchen right of fridge -provide better support for furr down above bar area -fireblock bar area wall space to ceiling space(seal gaps, penetrations, around beam) -fireblock furr down ends at beam in basement -provide support for furr down above bed 4 closet -fire block into bed 4 closet furr down -seal penetrations into return air joist space above basement sinks -provide support for furr down in bed 3 -fireblock into furr down bed 3 seal all gaps and penetrations -missing nails in hangers basement stairwell wall -nail exterior sheathing to code
Electrical Service Inspection Passed 12/28/2022
All Rough Inspection - Residential Failed 1/10/2023 1/10/2023 01/10/2023
Misc
Corrective Action Required
12/28/2022
-fireblock mast closet N wall to ceiling space-NOT DONE -over notched lvl ridge NE master bed-UNCOVER AND PROVIDE ENGINEER REPORT -provide straps at covered deck structural ridge per plans-NO PLAN ON SITE -fireblock dead space to ceiling space at kitchen right of fridge-NOT DONE -fireblock bar area wall space to ceiling space(seal gaps, penetrations, around beam)-SEAL GAPS -fireblock furr down ends at beam in basement -fire block into bed 4 closet furr down-INCOMPLETE -seal penetrations into return air joist space above basement sinks-NOT DONE *OK TO INSULATE-DO NOT COVER INSPECTION ITEMS
All Rough Inspection - Residential Failed 1/20/2023 01/20/2023
Misc
Corrective Action Required
01/10/2023
-over notched lvl ridge NE master bed-UNCOVER AND PROVIDE ENGINEER REPORT . No report found. -provide straps at covered deck structural ridge per plans-NO PLAN ON SITE, rafters and ridge covered at inspection. no post supporting end of ridge. provide Engineers letter for framed area, or uncover to inspect straps. also need letter from Eng that no post is required. -fireblock bar area wall space to ceiling space(seal gaps, penetrations, around beam)-SEAL GAPS -fireblock furr down ends at beam in basement , need to seal around the ends of the Ibeam where meet the soffit, Fire block vertical to horizontal to beam ends.
All Rough Inspection - Residential Passed 1/25/2023 1/25/2023 01/25/2023
Misc
Resolved
01/25/2023
-provide straps at covered deck structural ridge per plans-NO PLAN ON SITE, rafters and ridge covered at inspection. no post supporting end of ridge. provide Engineers letter for framed area, or uncover to inspect straps. also need letter from Eng that no post is
Gas Service Inspection - Residential Passed 1/26/2023 1/26/2023 01/26/2023
Driveway Inspection Partial 1/27/2023 1/27/2023 01/27/2023
Misc
Informational
01/27/2023
1-27-23 PS Forms are in place and aggregate has been compacted, ok to pour
Driveway Inspection Passed 2/3/2023 2/3/2023 02/03/2023
Misc
Informational
01/27/2023
1-27-23 PS Forms are in place and aggregate has been compacted, ok to pour 2-3-23 PS Driveway meets LS specifications
Erosion Control Inspection Residential Failed 2/22/2023 02/22/2023
DCM2 ESC DEFICIENT INSTALLATION
Resolved
02/22/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER CLEAN STREET
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/22/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/22/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/22/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Failed 5/11/2023 5/11/2023 05/11/2023
Misc
Corrective Action Required
05/11/2023
- Pay outstanding fees - Obtain an irrigation permit and submit back flow certification - seal DWV in garage - Provide box extension ( spark ring) at kitchen and bar outlets - Tighten and break off screw on back flow preventer at water main shut off spigot - Cap floor DWV bear water main - Label all non Gfci outlets in basement - Provide joist hangers for double and triple joists under deck Provide (2) 1/2” through bolts for each post to beam connections - Missing nails in deck joists hangers - Complete outlet near a/ c compressor - Provide anti tampering caps on a/ c compressor
Plot Plan Inspection Passed 5/11/2023 05/11/2023
Erosion Control Inspection Residential Passed 5/11/2023 05/11/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/11/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Resolved
05/11/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Resolved
05/11/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Failed 6/14/2023 6/14/2023 06/14/2023
Misc
Corrective Action Required
05/11/2023
- Pay outstanding fees - Provide anti tampering caps on a/ c compressor
Occupancy Inspection - Codes Residential Full C of O 7/6/2023 7/6/2023 07/06/2023
Misc
Resolved
07/06/2023
- Pay outstanding fees - Provide anti tampering caps on a/ c compressor
Documents & Images
Date Uploaded File Type Document Name
01/19/2022 SF-7027 (LOT 117WR)
01/19/2022 Permit Application
01/19/2022 Excise Tax Application
01/20/2022 Permit Codes Residential Plan Review
01/21/2022 Plot Plan Approved Plot Plan
02/02/2022 Approved Plans Approved Drawings
02/02/2022 Permit Codes Residential Plan Review
02/14/2022 Permit DS Building Permit
02/14/2022 Receipt Receipt for transaction: 2022-000800
03/31/2022 Letter INSPECTION SUMMARY
04/21/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/27/2022 Approved Plans Approved Suspended Slab drawing
05/09/2022 Letter INSPECTION SUMMARY
05/09/2022 Letter INSPECTION SUMMARY
05/31/2022 Pier inspection report
05/31/2022 Letter INSPECTION SUMMARY
10/18/2022 Letter Codes 140 Day Letter
12/28/2022 Letter INSPECTION SUMMARY
12/28/2022 Letter INSPECTION SUMMARY
01/10/2023 Letter INSPECTION SUMMARY
01/20/2023 Letter INSPECTION SUMMARY
01/20/2023 Lot 117 Engineering report for inspection
01/25/2023 Letter INSPECTION SUMMARY
01/26/2023 Letter INSPECTION SUMMARY
01/27/2023 Letter INSPECTION SUMMARY
02/03/2023 Letter INSPECTION SUMMARY
02/22/2023 Letter INSPECTION SUMMARY
05/10/2023 Plot Plan APPROVED AS GRADED PLOT PLAN
05/11/2023 Letter INSPECTION SUMMARY
05/11/2023 Letter INSPECTION SUMMARY
05/11/2023 Letter INSPECTION SUMMARY
05/12/2023 Receipt Receipt for transaction:2023-003168
07/06/2023 Letter Codes Final Certificate of Occupancy
07/06/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home