Permit Application Status

PRRES20216531


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20216531
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE. ROOF TRUSSES. ROOF TRUSSES. FINISHED/UNFINISHED BASEMENT. COVERED DECK. STOP WORK ORDER generated on 03/07/2022 12:00 AM by username 'Patrick Schonfeldt'. STOP WORK ORDER removed on 03/08/2022 12:00 AM by username 'Patrick Schonfeldt'.
12/29/2021
01/04/2022
06/28/2022
07/07/2023
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
AJ@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $420.00 $420.00 Paid 01/04/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 01/04/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 01/04/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 01/04/2022
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 01/04/2022
9110078-Valuation Fee New Single Family $1,092.37 $1,092.37 Paid 01/04/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/21/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 06/21/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 06/21/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 06/21/2023
9110080-3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 06/21/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Not Ready 3/7/2022 3/7/2022 03/07/2022
Misc
Corrective Action Required
03/07/2022
INSPECTION DENIED FOOTING POURED WITHOUT INSPECTION
Footing Inspection - Residential Failed - Stop Work 3/7/2022 3/7/2022 03/07/2022
Misc
Corrective Action Required
03/07/2022
FOOTING POURED WITHOUT INSPECTION ENGINEER REPORT REQUIRED TO BE UPLOADED TO PERMIT WITHIN 48 HOURS OF INSPECTION
Footing Inspection - Residential Passed 3/8/2022 3/8/2022 03/08/2022
Misc
Corrective Action Required
03/07/2022
APPROVED PER BRADLEY HUXOL 1/28/22
Underslab Plumbing Inspection - Residential Failed 3/10/2022 3/10/2022 03/10/2022
Misc
Corrective Action Required
03/07/2022
NO INSPECTION PERFORMED UNABLE TO INSPECT UNDERSLAB PLUMBING WITH SNOW COVER, RESCHEDULE WHEN CONDITIONS ALLOW FOR INSPECTION
Underslab Plumbing Inspection - Residential Passed 3/15/2022 3/15/2022 03/15/2022
Misc
Resolved
03/15/2022
Erosion Control Inspection Residential Partial 3/15/2022 3/15/2022 03/15/2022
Misc
Corrective Action Required
03/15/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Sewer Service Inspection - R Passed 4/6/2022 (1:00) 4/6/2022 04/06/2022
Water Service Inspection - R Partial 4/7/2022 4/7/2022 04/07/2022
Water Service Inspection - R Passed 4/8/2022 (11:15) 4/8/2022 04/08/2022
Erosion Control Inspection Residential Failed 4/8/2022 4/8/2022 04/08/2022
Misc
Resolved
04/08/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/08/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Not Ready 9/7/2022 9/7/2022 09/07/2022
Misc
Corrective Action Required
09/07/2022
-MAINTAIN WEEDS AND VEGEATION ON LOT -NO CITY STAMPED PLANS ON SITE AT TIME OF INSPECTION
Electrical Service Inspection Failed 9/7/2022 9/7/2022 09/07/2022
Misc
Corrective Action Required
09/07/2022
-MAINTAIN WEEDS AND VEGEATION ON LOT -NO CITY STAMPED PLANS ON SITE AT TIME OF INSPECTION
Gas Service Inspection - Residential Failed 9/7/2022 9/7/2022 09/07/2022
Misc
Corrective Action Required
09/07/2022
-MAINTAIN WEEDS AND VEGEATION ON LOT -NO CITY STAMPED PLANS ON SITE AT TIME OF INSPECTION
Electrical Service Inspection Passed 10/7/2022 10/7/2022 10/07/2022
Misc
Resolved
10/07/2022
-MAINTAIN WEEDS AND VEGEATION ON LOT -NO CITY STAMPED PLANS ON SITE AT TIME OF INSPECTION
Gas Service Inspection - Residential Passed 10/7/2022 10/7/2022 10/07/2022
Misc
Resolved
10/07/2022
-MAINTAIN WEEDS AND VEGEATION ON LOT -NO CITY STAMPED PLANS ON SITE AT TIME OF INSPECTION
All Rough Inspection - Residential Failed 10/7/2022 10/7/2022 10/07/2022
Misc
Corrective Action Required
09/07/2022
-no approved truss plans and drawings on site, unable to verify -solid block all sheathing breaks -exterior sheathing at garage, master bedroom, great room, front bedroom short of top plate and edge not nailed to plate per code -nail all butting and intersecting corners 12” oc -seal all top plate penetrations at garage -have engineer with truss manufacturer address broken truss in garage -seal HVAC plate penetration at master closet -fireblock all tub traps -bocca protection plates at DWV must protect at the plate and either 2” above bottom plate or 2” below top plate -address top plate corner lap connection at master bed exterior wall to great room wall, different plate heights -seal gas line floor penetration at fireplace -have engineer address dining room exterior walls, corners not tied together, headers cut and notched, missing king studs -CS-PF bracing design at dining room exterior wall per plans -fireblock between plates at dbl wall kitchen -front entry exterior wall top plates not lapped at corners -provide truss hood downs at both plies of girder trusses -provide full bearing for front covered porch beams at front bedroom and garage -provide truss hold downs at front covered porch -provide approved truss hold downs at covered deck trusses or provide documentation on screws installed showing rating for use on trusses -trusses modified above foyer, provide documentation from truss manufacturer -gable trusses have been cut and modified, provide documentation from truss manufacturer -address broken trusses above great room -solid shim all trimmer studs cut short of headers throughout -provide (4) 2x4 stud packs at front bedroom girder bearing points per plans -provide joist hanger at sgl to trpl beam connection at basement stair wall -provide anchor bolts within 12” of plate break at basement -fireblock vertical to horizontal at furred down soffit ends finished basement -fireblock vertically between studs and foundation/framing every 10’ at finished basement -solid block between joists at cantilevers -provide full length trimmer studs at basement bedroom window -missing stud basement bedroom closet, spacing more than 24” oc -solid block between joists every 48” oc at kitchen island per plans -(2) 1/2” through bolts each post/beam connection at deck -nail off all joist hangers at deck -nail exterior sheathing at garage portal PFH per plans/IRC R602.10.6.2 -nail all exterior sheathing per plans
All Rough Inspection - Residential Not Ready 12/15/2022 12/15/2022 12/15/2022
Misc
Corrective Action Required
10/07/2022
-Have approved truss plans on site for inspection, unable to confirm trusses or any repairs made from received engineer letters, the truss plans on site are scattered throughout the great room, details and layout should be complete and in order, make all repairs per engineer letters -have engineer with truss manufacturer address broken truss in garage -great room exterior wall sheathing not nailed to top plate per code -address top plate corner lap connection at master bed exterior wall to great room wall, different plate heights, (make correction per engineer letter) -have engineer address dining room exterior walls, corners not tied together, headers cut and notched, missing king studs (nail Jack stud at king stud and provide CS-PF tension straps at Jack studs) -fireblock between plates at dbl wall kitchen (not done) -provide truss hood downs at both plies of girder trusses (approved fasteners only) -trusses modified above foyer, provide documentation from truss manufacturer -gable trusses have been cut and modified, provide documentation from truss manufacturer -address broken trusses above great room -solid shim all trimmer studs cut short of headers throughout -provide anchor bolts within 12” of plate break at basement -provide full length trimmer studs at basement bedroom window -(2) 1/2” through bolts each post/beam connection at deck -nail all exterior sheathing per plans
All Rough Inspection - Residential Failed 12/16/2022 12/16/2022 12/16/2022
Misc
Corrective Action Required
12/15/2022
-great room exterior wall sheathing not nailed to top plate per code -provide anchor bolts within 12” of plate break at basement -nail all exterior sheathing per plans
All Rough Inspection - Residential Not Ready 12/27/2022 12/27/2022 12/27/2022
Misc
Corrective Action Required
12/16/2022
-great room exterior wall sheathing not nailed to top plate per code -nail all exterior sheathing per plans
All Rough Inspection - Residential Passed 12/30/2022 12/30/2022 12/30/2022
Misc
Resolved
12/30/2022
Driveway Inspection Partial 2/2/2023 2/2/2023 02/02/2023
Misc
Informational
02/02/2023
2-2-23 PS forms are in place and aggregate has been compacted, ok to pour
Sidewalk Inspection Partial 2/2/2023 2/2/2023 02/02/2023
Misc
Informational
02/02/2023
2-2-23 PS forms are in place and aggregate has been compacted, ok to pour
Sidewalk Inspection Passed 2/9/2023 2/9/2023 02/09/2023
Misc
Informational
02/09/2023
2-9-23 PS Sidewalk meets LS and ADA specifications
Driveway Inspection Passed 2/9/2023 2/9/2023 02/09/2023
Misc
Informational
02/02/2023
2-2-23 PS forms are in place and aggregate has been compacted, ok to pour 2-9-23 PS Driveway meets LS and ADA specifications
Occupancy Inspection - Codes Residential Failed 6/22/2023 6/22/2023 06/22/2023
Miscellaneous Correction
Corrective Action Required
06/22/2023
- Dishwasher is not on a GFCI breaker - House to garage door self closing hinge is not working - Vertical boards at ceiling in garage need to be sealed - Top is A/C disconnect needs to be sealed - Two 6x6 porch post supporting the stair platform need (2) 1/2 inch through bolts installed
Piers/Caissons Inspection - Residential Passed 6/22/2023 06/22/2023
Misc
Informational
06/22/2023
Signed off by third party at the time of footing
Erosion Control Inspection Residential Passed 6/22/2023 06/22/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
06/22/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Plot Plan Inspection Passed 6/22/2023 06/22/2023
Occupancy Inspection - Codes Residential Failed 6/30/2023 6/30/2023 06/30/2023
Miscellaneous Correction
Corrective Action Required
06/22/2023
- Dishwasher is not on a GFCI breaker - House to garage door self closing hinge is not working - Top is A/C disconnect needs to be sealed - tighten every all through deck post nuts
Occupancy Inspection - Codes Residential Full C of O 7/7/2023 7/7/2023 07/07/2023
Miscellaneous Correction
Resolved
07/07/2023
- Dishwasher is not on a GFCI breaker - House to garage door self closing hinge is not working - Top is A/C disconnect needs to be sealed - tighten every all through deck post nuts
Documents & Images
Date Uploaded File Type Document Name
12/29/2021 RR #95 - PERMIT APP
12/30/2021 Approved Plans APPROVED DRAWINGS
12/30/2021 Approved Plans APPROVED TRUSS LAYOUT
12/30/2021 Approved Plans APPROVED TRUSS PACKAGE
12/30/2021 Permit Codes Residential Plan Review
01/03/2022 Plot Plan APPROVED PLOT PLAN
01/03/2022 Permit Codes Residential Plan Review
01/04/2022 Permit DS Building Permit
01/04/2022 Receipt Receipt for transaction:2022-000030
03/07/2022 Letter INSPECTION SUMMARY
03/07/2022 Letter Stop Work Order
03/08/2022 95 Reserve at Stoney Creek Drilled Pier
03/08/2022 95 Reserve at Stoney Creek FTNG
03/08/2022 95 Reserve at Stoney Creek FDTN
03/08/2022 95 Reserve at Stoney Creek Subgrade
03/08/2022 Letter INSPECTION SUMMARY
03/10/2022 Letter INSPECTION SUMMARY
03/15/2022 Letter INSPECTION SUMMARY
03/15/2022 Letter INSPECTION SUMMARY
04/06/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/08/2022 Letter INSPECTION SUMMARY
04/08/2022 Letter INSPECTION SUMMARY
09/07/2022 Letter INSPECTION SUMMARY
09/07/2022 Letter INSPECTION SUMMARY
09/07/2022 Letter INSPECTION SUMMARY
10/07/2022 Letter INSPECTION SUMMARY
10/07/2022 Letter INSPECTION SUMMARY
10/07/2022 Letter INSPECTION SUMMARY
10/20/2022 95 Reserve at Stone Creek - 221018
10/20/2022 Letter APPROVED TRUSS LETTER
10/20/2022 Letter APPROVED TRUSS LETTER
10/20/2022 Letter APPROVED TRUSS LETTER
12/15/2022 Letter INSPECTION SUMMARY
12/16/2022 Letter INSPECTION SUMMARY
12/27/2022 Letter INSPECTION SUMMARY
12/29/2022 95 Reserve at stoney creek letter #2
12/30/2022 Letter INSPECTION SUMMARY
02/02/2023 Letter INSPECTION SUMMARY
02/02/2023 Letter INSPECTION SUMMARY
02/09/2023 Letter INSPECTION SUMMARY
02/09/2023 Letter INSPECTION SUMMARY
06/21/2023 Receipt Receipt for transaction:2023-004704
06/22/2023 Letter INSPECTION SUMMARY
06/22/2023 Letter INSPECTION SUMMARY
06/22/2023 Letter INSPECTION SUMMARY
06/22/2023 Letter INSPECTION SUMMARY
06/30/2023 Letter INSPECTION SUMMARY
07/07/2023 Letter Codes Final Certificate of Occupancy
07/07/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home