Permit Application Status

PRRES20216160


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20216160
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
11/30/2021
12/02/2021
05/30/2022
09/28/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
michael@summithomeskc.com  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $630.00 $630.00 Paid 12/02/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 12/02/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 12/02/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 12/02/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 12/02/2021
9110078-Valuation Fee New Single Family $1,592.84 $1,592.84 Paid 12/02/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 09/28/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/30/2021 12/30/2021
Misc
Informational
12/30/2021
3RD PARTY FOOTING BY DEREK PEREZ @ EVERSTEAD SIGNED & SEALED BY BRADLEY HUXOL UFER LOCATED NEAR SOUTHWEST ( REAR LEFT) CORNER OF GARAGE FOUNDATION WALL
Sewer Service Inspection - R Passed 1/31/2022 01/31/2022
Water Service Inspection - R Passed 2/1/2022 02/01/2022
Erosion Control Inspection Residential Failed 2/10/2022 2/10/2022 02/10/2022
DCM5 ESC INSP DENIED
Corrective Action Required
02/10/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -MAINTAIN GRAVEL FILTER -EROSION CONTROL AT FRONT OF LOT NOT IN COMPLIANCE
Underslab Plumbing Inspection - Residential Failed 2/10/2022 2/10/2022 02/10/2022
Misc
Corrective Action Required
02/10/2022
INSPECTION DENIED DUE TO LACK OF EROSION CONTROL
Underslab Plumbing Inspection - Residential Passed 2/11/2022 2/11/2022 02/11/2022
Misc
Resolved
02/11/2022
Erosion Control Inspection Residential Failed 2/11/2022 02/11/2022
DCM5 ESC INSP DENIED
Corrective Action Required
02/10/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. - SPREAD GRAVEL FILTER AT DRIVEWAY -
Erosion Control Inspection Residential Failed 3/23/2022 03/23/2022
DCM5 ESC INSP DENIED
Corrective Action Required
02/11/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. - SPREAD GRAVEL FILTER AT DRIVEWAY -
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/23/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE -
Electrical Service Inspection Passed 5/25/2022 5/25/2022 05/25/2022
Gas Service Inspection - Residential Passed 5/25/2022 5/25/2022 05/25/2022
All Rough Inspection - Residential Failed 5/25/2022 5/25/2022 05/25/2022
Miscellaneous Correction
Corrective Action Required
05/25/2022
No pier inspection on record Missing H2.5s covered patio Provide 4x4 cedar post to ridge beam front porch per plan Replace blocking at stair landing Provide (4) 2x6 stud pack at stair landing per plan Solid block & nail sheathing per code at above Provide CS-PF bracing per plan dining room Strap corner dining room / garage no plate overlap Provide 3" SCH 40 column under LVL foyer per plan Provide hanger triple LVL room Provide hanger triple 2x10 above pantry door & nail triple from both sides Fire block dwv pantry Seal upward penetrations pantry (pex) Furr out HVAC at refrigerator Provide angle hanger 2x10 flex room Provide 2 nails in top bottom plates of LIBs garage Provide double joist hanger at cantilever near service panel Replace blocking at cantilever ( gas line ) Provide solid blocking between joist under kitchen island per plan Provide anchor bolts SCH 40 columns basement Provide hangers at header near furnace Seal upward penetration bath 2 / laundry Seal fb dead space master closet / HVAC Seal furr out at master shower Replace stud master closet Provide flashing above horizontal exterior trim above windows
Driveway Inspection Not Ready 6/7/2022 6/7/2022 06/07/2022
All Rough Inspection - Residential Failed 6/14/2022 6/14/2022 06/14/2022
Miscellaneous Correction
Corrective Action Required
05/25/2022
-No pier inspection on record -Missing H2.5s covered patio -Provide 4x4 cedar post to ridge beam front porch per plan -Replace blocking at cantilever ( gas line ) -Provide flashing above horizontal exterior trim above windows
Piers/Caissons Inspection - Residential Passed 06/20/2022
Misc
Informational
06/20/2022
THIRD PARTY INSPECTION PERFORMED
All Rough Inspection - Residential Passed 6/20/2022 6/20/2022 06/20/2022
Miscellaneous Correction
Resolved
06/20/2022
Driveway Inspection Partial 6/29/2022 6/29/2022 06/29/2022
Misc
Informational
06/29/2022
Driveway was framed up with aggregate in and compacted. 6/29/22 ES
Driveway Inspection Passed 7/8/2022 7/8/2022 07/08/2022
Misc
Informational
06/29/2022
Driveway was framed up with aggregate in and compacted. 6/29/22 ES Driveway meets LS spec. 7/8/22 ES
Plot Plan Inspection Failed 9/19/2022 09/19/2022
Miscellaneous Correction
Corrective Action Required
09/19/2022
MAINTAIN GUTTER BUDDY REMOVE SILT AND WEEDS REMOVE CONSTRUCTION DEBRIS PROVIDE FINAL GRADE
Plot Plan Inspection Passed 9/23/2022 09/23/2022
Miscellaneous Correction
Corrective Action Required
09/19/2022
MAINTAIN GUTTER BUDDY REMOVE SILT AND WEEDS
Occupancy Inspection - Codes Residential Failed 9/23/2022 9/23/2022 09/23/2022
Miscellaneous Correction
Corrective Action Required
09/23/2022
MAINTAIN GUTTER BUDDY REMOVE SILT AND WEEDS Clean steet, gutters of mud & gravel Provide guardrail front stoop over 30" to grade Tighten self closing hinges so garage door is self closing Water heater pressure relief valve discharge pipe to terminate not more than 6" and not less than 2 times pipe diameter above floor ( 2018 IRC P2804.6.1 (10) Lower water meter lid to grade level maintain 14" to 18" meter to lid
Occupancy Inspection - Codes Residential Full C of O 9/28/2022 9/28/2022 09/28/2022
Miscellaneous Correction
Resolved
09/28/2022
Documents & Images
Date Uploaded File Type Document Name
11/30/2021 W0 #122 - Permit App
11/30/2021 W0122
12/01/2021 Approved Plans Approved Drawings
12/01/2021 Approved Plans Approved Truss Layout
12/01/2021 Approved Plans Approved Truss Pacakge
12/01/2021 Permit Codes Residential Plan Review
12/02/2021 Plot Plan Approved Plot Plan
12/02/2021 Permit Codes Residential Plan Review
12/02/2021 Permit DS Building Permit
12/02/2021 Receipt Receipt for transaction:2021-009059
12/30/2021 122 Woodside Ridge-FTNG
12/30/2021 Letter INSPECTION SUMMARY
01/31/2022 Letter INSPECTION SUMMARY
02/01/2022 Letter INSPECTION SUMMARY
02/10/2022 Letter INSPECTION SUMMARY
02/10/2022 Letter INSPECTION SUMMARY
02/11/2022 Letter INSPECTION SUMMARY
02/11/2022 Letter INSPECTION SUMMARY
03/23/2022 Letter INSPECTION SUMMARY
05/25/2022 Letter INSPECTION SUMMARY
05/25/2022 Letter INSPECTION SUMMARY
05/25/2022 Letter INSPECTION SUMMARY
06/01/2022 122 Woodside Ridge Deck Piers
06/07/2022 Letter INSPECTION SUMMARY
06/14/2022 Letter INSPECTION SUMMARY
06/20/2022 Letter INSPECTION SUMMARY
06/20/2022 Letter INSPECTION SUMMARY
06/29/2022 Letter INSPECTION SUMMARY
07/08/2022 Letter INSPECTION SUMMARY
09/16/2022 Plot Plan Approved As Graded Plot Plan
09/19/2022 Letter INSPECTION SUMMARY
09/23/2022 Letter INSPECTION SUMMARY
09/23/2022 Letter INSPECTION SUMMARY
09/28/2022 Receipt Receipt for transaction:2022-007870
09/28/2022 Letter Codes Final Certificate of Occupancy
09/28/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home