Summary
PRRES20215679
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - PARTIAL FINISHED BASEMENT - UNCOVERED PATIO STOP WORK ORDER generated on 05/06/2022 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 05/12/2022 12:00 AM by username 'Mitchell Schwarz'.
10/30/2021
11/24/2021
04/30/2022
04/24/2023
Locations
Contacts
ELEVATE DESIGN & BUILD LLC, Address:350 SW LONGVIEW BLVD, Phone:(816) 622-8826  
Elevate Design + Build , Address:350 Longview Blvd.   
R-MECH HEATING COOLING PLUMBING/RHODES HEATING COOLING PLUMBING AND ROOTER, Address:1425 AGNES AVE, Phone:(816) 920-5955  
ELECTRICAL CONNECTIONS, Address:20112 HOPS CREEK DR, Phone:(816) 838-6946  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
GLEN@elevatedesignbuildkc.com  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 11/24/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 11/24/2021
9110078-Valuation Fee New Single Family $1,322.77 $1,322.77 Paid 11/24/2021
8331507-Sewer Connection Fee $450.00 $450.00 Paid 11/24/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 11/24/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 11/24/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 05/09/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 05/09/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/07/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/21/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 12/05/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 04/20/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 04/21/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 04/21/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 04/21/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/27/2021 (8:15) 12/27/2021 12/27/2021
Misc
Informational
12/28/2021
3rd party
Sewer Service Inspection - R Passed 1/24/2022 (8:45) 1/24/2022 01/24/2022
Water Service Inspection - R Partial 1/24/2022 (8:45) 1/24/2022 01/24/2022
Underslab Plumbing Inspection - Residential Failed 1/25/2022 01/25/2022
Misc
Corrective Action Required
01/25/2022
-sump pump pit installed
Water Service Inspection - R Passed 1/25/2022 (1:15) 1/25/2022 01/25/2022
Underslab Plumbing Inspection - Residential Passed 1/28/2022 1/28/2022 01/28/2022
Misc
Resolved
01/28/2022
-sump pump pit installed
Erosion Control Inspection Residential Failed 5/3/2022 05/03/2022
DCM5 ESC INSP DENIED
Corrective Action Required
05/03/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -downed silt fence -maintain gravel filter
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/03/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
All Rough Inspection - Residential Not Ready 5/3/2022 5/3/2022 05/03/2022
Misc
Corrective Action Required
05/03/2022
inspection denied due to lack of erosion control
Erosion Control Inspection Residential Failed - Stop Work 5/6/2022 05/06/2022
DCM5 ESC INSP DENIED
Corrective Action Required
05/03/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -downed silt fence -maintain gravel filter
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/03/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM5 ESC INSP DENIED
Corrective Action Required
05/06/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. gravel filter still not in compliance Mitchell Schwarz 05/06/2022 1:11 PM
All Rough Inspection - Residential Failed 5/6/2022 5/6/2022 05/06/2022
Misc
Corrective Action Required
05/03/2022
inspection denied due to lack of erosion control Mitchell Schwarz 05/06/2022 1:10 PM
Erosion Control Inspection Residential Partial 5/12/2022 5/12/2022 05/12/2022
DCM5 ESC INSP DENIED
Resolved
05/12/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -downed silt fence -maintain gravel filter
DCM3 ESC REQUIRED 2 DAY
Resolved
05/12/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM5 ESC INSP DENIED
Resolved
05/12/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. gravel filter still not in compliance Mitchell Schwarz 05/06/2022 1:11 PM
Misc
Informational
05/12/2022
Erosion control back in compliance at time of inspection
Gas Service Inspection - Residential Passed 5/13/2022 5/13/2022 05/13/2022
Electrical Service Inspection Failed 5/13/2022 5/13/2022 05/13/2022
Misc
Corrective Action Required
05/13/2022
-Identify ufer conductor at both ends -Unable to vefiry ufer connection-possibly covered in garage?. This must be accessible
All Rough Inspection - Residential Not Ready 5/13/2022 5/13/2022 05/13/2022
Misc
Corrective Action Required
05/06/2022
This house is not ready and this list is incomplete. Complete all of these items and check house for common deficiencies before scheduling a re inspection -Uncover porch framing for inspection -Provide anchor bolt within 12” of plate break near beam stud pack -Addtess exterior wall top plate not overlapping 24” at garage: entry and garage by stairs -Anchor bolts per code at rear garage wall -Address joists bored closer than 2” to bottom of joist throughout garage -Support hip rafters at top in single car bay -Sister over notched studs at exterior garage wall all locations -30” of clearance required at attic access -Straps at both sides of cut out top plates for hvac need to extend 6” past cut out each direction and have min (4) 10d nails each side at all locations -Complete fireblocking at ceiling line in powder room -Fireblock soffit line at owner’s entry/ kitchen -Provide Bocca plates at dwv in kitchen/ owner’s entry -Protect nm less than 1.25” to face of framing bottom plate near fridge, near range, at studs at window, and THROUGHOUT -Secure electrical boxes at kitchen and fireplace -Bocca plate protection THROUGHOUT -Address holes in joists bored closer together than 2” and closer than 2” to bottom throughout kitchen-Check throughout the house as this is also above electrical panel, behind furnace and basement -Unable to find ufer connection, if this is in the garage and boxed out, be aware that this needs to be accessible
Electrical Service Inspection Passed 6/8/2022 6/8/2022 06/08/2022
Misc
Resolved
06/08/2022
-Identify ufer conductor at both ends -Unable to vefiry ufer connection-possibly covered in garage?. This must be accessible
All Rough Inspection - Residential Failed 6/8/2022 6/8/2022 06/08/2022
Misc
Corrective Action Required
05/13/2022
-top plate penetration between garage doors -Uncover porch framing for inspection -Address joists bored closer than 2” to bottom of joist throughout garage -Sister over notched studs at exterior garage wall all locations (sisters stud to be full length) -Fireblock soffit line at owner’s entry/ kitchen -fireblock hvac chase -Protect nm less than 1.25” to face of framing thorough out -Address holes in joists bored closer together than 2” and closer than 2” to bottom throughout kitchen -address rafters landing on blocks throughout -support dwv above 2nd floor hall bath -provide proper slope for dwv above 2nd story hall -
All Rough Inspection - Residential Not Ready 6/16/2022 6/16/2022 06/16/2022
Misc
Corrective Action Required
06/08/2022
-Uncover porch framing for inspection -Address joists bored closer than 2” to bottom of joist throughout garage -Sister over notched studs at exterior garage wall all locations (sisters stud to be full length) -fireblock hvac chase -Address holes in joists bored closer together than 2” and closer than 2” to bottom throughout kitchen
All Rough Inspection - Residential Passed 6/21/2022 6/21/2022 06/21/2022
Misc
Resolved
06/21/2022
Driveway Inspection Partial 7/20/2022 7/20/2022 07/20/2022
Misc
Informational
07/20/2022
On 7.20.2022 I conducted a driveway inspection and passed the subgrade to pour concrete
Driveway Inspection Passed 8/31/2022 8/31/2022 07/21/2022
Misc
Informational
07/20/2022
On 7.20.2022 I conducted a driveway inspection and passed the subgrade to pour concrete 7.21.2022 Driveway appears to be in compliance
Plot Plan Inspection Passed 10/18/2022 10/18/2022
Occupancy Inspection - Codes Residential Failed 10/18/2022 10/18/2022 10/18/2022
Misc
Corrective Action Required
10/18/2022
-sod -splash blocks and sump pump discharge to extend 36” from foundation -label all non GFCI outlets in unfinished spaces -lock out for hot water heater breaker -water heater relief valve pipe to code P2804.6.1 of irc
Occupancy Inspection - Codes Residential Ready for Temp CO 12/2/2022 12/2/2022 12/02/2022
Misc
Corrective Action Required
10/18/2022
-sod -splash blocks and sump pump discharge to extend 36” from foundation
Occupancy Inspection - Codes Residential Failed 1/4/2023 01/04/2023
Misc
Corrective Action Required
12/02/2022
TCO extension form to be submitted -sod -splash blocks and sump pump discharge to extend 36” from foundation
Erosion Control Inspection Residential Passed 04/21/2023
Misc
Resolved
04/21/2023
Erosion control back in compliance at time of inspection
Occupancy Inspection - Codes Residential Failed 4/21/2023 4/21/2023 04/21/2023
Misc
Corrective Action Required
01/04/2023
Pay fees
Occupancy Inspection - Codes Residential Full C of O 4/24/2023 04/24/2023
Misc
Resolved
04/24/2023
Pay fees
Documents & Images
Date Uploaded File Type Document Name
10/30/2021 License Tax Application
10/30/2021 Residental Permit Application
11/01/2021 Permit Codes Residential Plan Review
11/17/2021 21-11-17 - HF 048 - Review Comment Response
11/18/2021 Plot Plan Approved Plot Plan
11/23/2021 Approved Plans APPROVED DRAWINGS
11/23/2021 Permit Codes Residential Plan Review
11/24/2021 Permit DS Building Permit
11/24/2021 Receipt Receipt for transaction:2021-008930
12/25/2021 48 Hook Farms-FTNG
12/29/2021 Letter INSPECTION SUMMARY
01/24/2022 Letter INSPECTION SUMMARY
01/24/2022 Letter INSPECTION SUMMARY
01/25/2022 Letter INSPECTION SUMMARY
01/28/2022 Letter INSPECTION SUMMARY
01/28/2022 Letter INSPECTION SUMMARY
05/03/2022 Letter INSPECTION SUMMARY
05/03/2022 Letter INSPECTION SUMMARY
05/06/2022 Letter INSPECTION SUMMARY
05/06/2022 Letter Stop Work Order
05/06/2022 Letter INSPECTION SUMMARY
05/09/2022 Receipt Receipt for transaction:2022-003079
05/12/2022 Letter INSPECTION SUMMARY
05/13/2022 Letter INSPECTION SUMMARY
05/13/2022 Letter INSPECTION SUMMARY
05/13/2022 Letter INSPECTION SUMMARY
06/07/2022 2036 SW Wheatfield Ct Letter - signed
06/07/2022 Receipt Receipt for transaction:2022-004441
06/08/2022 Letter INSPECTION SUMMARY
06/13/2022 48 Hook Letter
06/16/2022 Letter INSPECTION SUMMARY
06/16/2022 Letter INSPECTION SUMMARY
06/21/2022 Receipt Receipt for transaction:2022-004919
06/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
10/18/2022 Letter INSPECTION SUMMARY
10/18/2022 Letter INSPECTION SUMMARY
12/05/2022 Certificate/License Codes Temporary Certificate of Occupancy
12/05/2022 Receipt Receipt for transaction:2022-009290
04/20/2023 Certificate/License Codes Temporary Certificate of Occupancy
04/20/2023 Receipt Receipt for transaction:2023-002267
04/21/2023 Letter INSPECTION SUMMARY
04/21/2023 Letter INSPECTION SUMMARY
04/21/2023 Letter INSPECTION SUMMARY
04/21/2023 Certificate/License Codes Temporary Certificate of Occupancy
04/21/2023 Certificate/License Codes Temporary Certificate of Occupancy
04/21/2023 Certificate/License Codes Temporary Certificate of Occupancy
04/21/2023 Receipt Receipt for transaction:2023-002314
04/24/2023 Letter Codes Final Certificate of Occupancy
04/24/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home