Permit Application Status

PRRES20215139


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20215139
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW 3 OR 4 FAMILY
NEW FOUR-PLEX - ROOF TRUSSES - FINISHED AND UNFINISHED BASEMENT - UNCOVERED DECK
10/01/2021
10/22/2021
04/03/2022
11/07/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New 3 or 4 Family $3,058.66 $3,058.66 Paid 10/22/2021
8331504-EFHB Middle Big Creek, Full $1,607.04 $1,607.04 Paid 10/22/2021
8331507-Sewer Connection Fee $1,440.00 $1,440.00 Paid 10/22/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/22/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 10/22/2021
8331401-Water Tap Fee $14,620.00 $14,620.00 Paid 10/22/2021
8350015-Water Meter Fee $1,916.96 $1,916.96 Paid 10/22/2021
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 10/05/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 10/05/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 10/26/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/29/2021 11/29/2021 11/29/2021
Misc
Informational
11/29/2021
Ufer ground rods are located in back wall of garages as indicated in third party inspection report.
Underslab Plumbing Inspection - Residential Passed 12/22/2021 12/22/2021 12/22/2021
Sewer Service Inspection - R Partial 12/22/2021 (11:00) 12/22/2021 12/22/2021
Misc
Informational
12/22/2021
3723 ok
Sewer Service Inspection - R Partial 1/25/2022 01/25/2022
Misc
Informational
12/22/2021
3723,3727 ok
Sewer Service Inspection - R Passed 1/31/2022 01/31/2022
Misc
Informational
01/25/2022
3723,3727,3721,3725 ok
Water Service Inspection - R Passed 2/15/2022 (11:00) 2/15/2022 02/15/2022
Misc
Informational
02/15/2022
3721, 3723, 3725, 3727 OK
Erosion Control Inspection Residential Failed 2/15/2022 2/15/2022 02/15/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/15/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Electrical Service Inspection Failed 7/12/2022 07/12/2022
Misc
Corrective Action Required
07/12/2022
INSPECTION DENIED NO CITY STAMPED PLANS ON SITE AT INSPECTION
All Rough Inspection - Residential Not Ready 3/4/2022 7/12/2022 07/12/2022
Misc
Corrective Action Required
07/12/2022
INSPECTION DENIED NO CITY STAMPED PLANS ON SITE AT INSPECTION
Gas Service Inspection - Residential Failed 7/12/2022 07/12/2022
Misc
Corrective Action Required
07/12/2022
INSPECTION DENIED NO CITY STAMPED PLANS ON SITE AT INSPECTION
Rated Assembly Inspection Failed 7/12/2022 7/12/2022 07/12/2022
Misc
Corrective Action Required
07/12/2022
INSPECTION DENIED NO CITY STAMPED PLANS ON SITE AT INSPECTION
Gas Service Inspection - Residential Failed 7/14/2022 7/14/2022 07/14/2022
Misc
Informational
07/14/2022
Unit 3727 ok
Electrical Service Inspection Failed 7/14/2022 7/14/2022 07/14/2022
Misc
Corrective Action Required
07/12/2022
Unit 3727 interior ok
All Rough Inspection - Residential Failed 7/14/2022 7/14/2022 07/14/2022
Misc
Corrective Action Required
07/12/2022
-PROVIDE TRUSS PLANS BEFORE ANY FURTHER INSPECTION UNIT 3727 -Anchor bolts at PFH to be in middle third of plate with 2x2” x 3/16” plate washer -Nail all exterior corners and intersecting walls 12” oc -Provide engineer letter for field fix if joists bored closer than 2” at foyer -Seal plate penetrations at pex in pantry -Protect dryer duct at top plate penetration 2” below plate-fur out? -Relocate roof vent and repair fire rated sheathing at roof -Provide missing fasteners at stud shoes in bath 1 -Bocca plate bath 1 -Anchor bolts at plate break under stairs -Structural strap at overboard top plate in basement bath -Provide joist hanger at furnace -Holes bored in joists closer than 2” in basement bath -Missing anchor bolts at entire back wall -Support/ secure service cable -Relocate smoke detector currently in soffit bed 3 -Land electrical at stair soffit
Rated Assembly Inspection Failed 7/14/2022 7/14/2022 07/14/2022
Misc
Corrective Action Required
07/12/2022
UNIT 3727 Relocate roof vent and repair fire rated sheathing at roof
All Rough Inspection - Residential Failed 8/17/2022 8/17/2022 08/17/2022
Misc
Corrective Action Required
07/14/2022
3727-Roof vent in attic within 4’of fire wall. -Fur out laundry room for dryer vent , firestop at the top plate. -Nail electrical box right of slider. -Support gas line. -No elect to entry light . 3725 -Support HVAC pvc vent . -Move flex duct over attic access. -Fire stop fur out for laundry vent . 3723 -roof vents. - support HVAC 3721 - support HVAC - roof vents.
Gas Service Inspection - Residential Passed 8/17/2022 08/17/2022
Misc
Resolved
08/17/2022
Unit 3727 ok
Electrical Service Inspection Passed 8/17/2022 08/17/2022
Misc
Resolved
08/17/2022
Unit 3727 interior ok
Driveway Inspection Partial 8/22/2022 8/22/2022 08/22/2022
Misc
Informational
08/22/2022
8-22-22 RH. Driveway was formed up and aggregate was placed and compacted for units 12A-12D.
Sidewalk Inspection Partial 8/22/2022 8/22/2022 08/22/2022
Misc
Informational
08/22/2022
8-22-22 RH. Sidewalk was formed up and aggregate placed and compacted for units 12A-12D.
Rated Assembly Inspection Passed 8/22/2022 8/22/2022 08/22/2022
Misc
Resolved
08/22/2022
UNIT 3727 Relocate roof vent and repair fire rated sheathing at roof
All Rough Inspection - Residential Passed 8/22/2022 8/22/2022 08/22/2022
Misc
Resolved
08/22/2022
Rated Assembly Inspection Not Ready 9/1/2022 09/01/2022
Misc
Corrective Action Required
09/01/2022
-gb bracing not completed at all addressed
Rated Assembly Inspection Failed 9/2/2022 9/2/2022 09/02/2022
Misc
Corrective Action Required
09/01/2022
3721 dining room under window Not complete 3723 Ok 3725 - not complete 3727 -above basement stairs Wall on stairs to 2 floor - Under window both bedrooms
Rated Assembly Inspection Passed 9/6/2022 9/6/2022 09/06/2022
Misc
Resolved
09/06/2022
Piers/Caissons Inspection - Residential Partial 9/8/2022 9/8/2022 09/08/2022
Misc
Corrective Action Required
09/08/2022
UNIT 3127 OK
Piers/Caissons Inspection - Residential Partial 9/9/2022 9/9/2022 09/09/2022
Misc
Corrective Action Required
09/08/2022
UNIT 3721 OK UNIT 3723 OK
Piers/Caissons Inspection - Residential Partial 9/12/2022 (2:00) 9/12/2022 09/12/2022
Misc
Corrective Action Required
09/09/2022
UNIT 3721 OK UNIT 3723 OK UNIT 3725 OK
Piers/Caissons Inspection - Residential Passed 9/14/2022 (8:00) 9/14/2022 09/14/2022
Misc
Informational
09/14/2022
UNIT 3721 OK UNIT 3723 OK UNIT 3725 OK UNIT 3727 OK
Driveway Inspection Passed 10/11/2022 10/11/2022 10/11/2022
Misc
Informational
08/22/2022
8-22-22 RH. Driveway was formed up and aggregate was placed and compacted for units 12A-12D. 10-11-22 RH. Driveway meets LS and ADA specification.
Sidewalk Inspection Passed 10/11/2022
Misc
Informational
08/22/2022
8-22-22 RH. Sidewalk was formed up and aggregate placed and compacted for units 12A-12D. 10-11-22 RH. Sidewalk meets LS and ADA specification.
Erosion Control Inspection Residential Passed 10/21/2022 10/21/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
10/21/2022
Occupancy Inspection - Codes Residential Failed 10/21/2022 10/21/2022 10/21/2022
Misc
Corrective Action Required
10/21/2022
3721 sw maryville pl - Garage entry door needs to latch - Seal exterior penetrations , gas meter and sump discharge 3723 sw maryville pl - post address - Garage entry door needs to latch - Complete nosing on stairs to living room - Route drain line for humidifier
Occupancy Inspection - Codes Residential Failed 10/25/2022 10/25/2022 10/25/2022
Misc
Corrective Action Required
10/21/2022
-Uncover manhole MH7-2 at front of lot per plot plan -Sump pump 36” discharge from foundation -nail off all joist hangers at deck UNIT 3721 -provide anti siphon device at spigot mechanical room, shear off set screw head after tightening -provide pressure regulator main water line -hammer arrestor at dishwasher UNIT 3723 -provide anti siphon device at spigot mechanical room, shear off set screw head after tightening -provide pressure regulator main water line -hammer arrestor at dishwasher UNIT 3725 -post address -provide anti siphon device at spigot mechanical room, shear off set screw head after tightening -provide pressure regulator main water line -mark sump pump outlet not gfci protected -hammer arrestor at dishwasher -water meter covered with grade UNIT 3727 -post address -secure romex for light at sump pump mechanical to code -provide anti siphon device at spigot mechanical room, shear off set screw head after tightening -provide pressure regulator main water line -mark sump pump outlet not gfci protected -provide AFCI protection at kitchen circuits -hammer arrestor at dishwasher
Occupancy Inspection - Codes Residential Ready for Temp CO 10/26/2022 10/26/2022 10/26/2022
Misc
Corrective Action Required
10/25/2022
-Uncover manhole MH7-2 at front of lot per plot plan, raise to grade if necessary -Sump pump 36” discharge from foundation -nail off all joist hangers at deck UNIT 3721 INTERIOR OK UNIT 3723 -provide anti siphon device at spigot mechanical room, shear off set screw head after tightening -provide pressure regulator main water line -hammer arrestor at dishwasher UNIT 3725 INTERIOR OK UNIT 3727 -post address -secure romex for light at sump pump mechanical to code -provide anti siphon device at spigot mechanical room, shear off set screw head after tightening -provide pressure regulator main water line -mark sump pump outlet not gfci protected -provide AFCI protection at kitchen circuits -hammer arrestor at dishwasher
Occupancy Inspection - Codes Residential Failed 10/31/2022 10/31/2022 10/31/2022
Misc
Corrective Action Required
10/26/2022
-Uncover manhole MH7-2 at front of lot per plot plan, raise to grade if necessary, (CONTACT DEVELOPMENT SERVICES CONCERNING CHANGES TO MANHOLE LOCATIONS FROM DEVELOPMENT AGREEMENTS, REVISED PLOT PLAN WILL NEED TO BE SUBMITTED AND APPROVED) UNIT 3721 INTERIOR OK UNIT 3723 OK UNIT 3725 INTERIOR OK UNIT 3727 OK
Plot Plan Inspection Passed 11/7/2022 11/7/2022 11/07/2022
Occupancy Inspection - Codes Residential Full C of O 11/7/2022 11/7/2022 11/07/2022
Misc
Resolved
11/07/2022
Documents & Images
Date Uploaded File Type Document Name
10/01/2021 OS #12 - PERMIT APP
10/05/2021 Approved Plans APPROVED TRUSS LAYOUT
10/05/2021 Approved Plans APPROVED TRUSS PACKAGE
10/05/2021 Permit Codes Residential Plan Review
10/06/2021 Engineer Report/Study ENGINEER LETTER
10/22/2021 Plot Plan APPROVED PLOT PLAN
10/22/2021 Permit Codes Residential Plan Review
10/22/2021 Permit DS Building Permit
10/22/2021 Receipt Receipt for transaction:2021-008169
11/24/2021 M L Crose 3721 3723 3725 3727 SW Maryville PL LSMO Osage Lot 12 Clayton P 2021-5139 3rd Party Footing Inspection Report 11-18-21
11/29/2021 Letter INSPECTION SUMMARY
12/22/2021 Letter INSPECTION SUMMARY
12/22/2021 Letter INSPECTION SUMMARY
01/25/2022 Letter INSPECTION SUMMARY
01/27/2022 Approved Plans APPROVED PLANS
01/31/2022 Letter INSPECTION SUMMARY
02/15/2022 Letter INSPECTION SUMMARY
02/15/2022 Letter INSPECTION SUMMARY
07/07/2022 12 osage letter #2
07/12/2022 Letter INSPECTION SUMMARY
07/12/2022 Letter INSPECTION SUMMARY
07/12/2022 Letter INSPECTION SUMMARY
07/12/2022 Letter INSPECTION SUMMARY
07/14/2022 Letter INSPECTION SUMMARY
07/14/2022 Letter INSPECTION SUMMARY
07/14/2022 Letter INSPECTION SUMMARY
07/14/2022 Letter INSPECTION SUMMARY
08/17/2022 Letter INSPECTION SUMMARY
08/17/2022 Letter INSPECTION SUMMARY
08/17/2022 Letter INSPECTION SUMMARY
08/22/2022 Letter INSPECTION SUMMARY
08/22/2022 Letter INSPECTION SUMMARY
08/22/2022 Letter INSPECTION SUMMARY
08/22/2022 Letter INSPECTION SUMMARY
09/02/2022 Letter INSPECTION SUMMARY
09/02/2022 Letter INSPECTION SUMMARY
09/06/2022 Letter INSPECTION SUMMARY
09/08/2022 Letter INSPECTION SUMMARY
09/09/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
09/14/2022 Letter INSPECTION SUMMARY
10/05/2022 Receipt Receipt for transaction:2022-008049
10/11/2022 Letter INSPECTION SUMMARY
10/11/2022 Letter INSPECTION SUMMARY
10/21/2022 Letter INSPECTION SUMMARY
10/21/2022 Letter INSPECTION SUMMARY
10/25/2022 Letter INSPECTION SUMMARY
10/26/2022 Certificate/License Codes Temporary Certificate of Occupancy
10/26/2022 Receipt Receipt for transaction:2022-008531
10/31/2022 Letter INSPECTION SUMMARY
11/04/2022 LOT 11 CITY 11-3-22
11/04/2022 LOT 12 CITY 11-3-22
11/04/2022 Plot Plan approved plot plan
11/07/2022 Letter INSPECTION SUMMARY
11/07/2022 Letter Field Certificate of Occupancy
11/07/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home