Permit Application Status

PRRES20214054


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20214054
Building Permit - Residential
Certificate of Occupancy
SILVERSTONE DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW HOUSE - PARTIAL FINISHED BASEMENT - COVERED DECK
08/04/2021
08/09/2021
02/01/2022
09/28/2022
Locations
Contacts
NICK ZVACEK CONSTRUCTION LLC, Address:1009 INDUSTRIAL DR, Phone:(816) 213-7204  
SILVERSTONE DEVELOPMENT LLC, Address:PO BOX 346  
Nick Zvacek, Address:1009 Industrial Drive, Phone:(816) 325-3440  
COMFORT SYSTEMS HTG/CLG, Address:17232 BEL-RAY PL, Phone:(816) 322-1013  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
JEFF.BOEHM@ZVACEKCONSTRUCTION.COM  
Leah Chaney, Address:1009 Industrial Drive  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/09/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 08/09/2021
8331507-Sewer Connection Fee $570.00 $570.00 Paid 08/09/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 08/09/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 08/09/2021
9110078-Valuation Fee New Single Family $1,370.10 $1,370.10 Paid 08/09/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 09/28/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 09/28/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 09/28/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 09/28/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/24/2021 08/24/2021
Informational
08/24/2021
FOOTING APPROVED BY ENGINEER
Underslab Plumbing Inspection - Residential Passed 10/1/2021 10/1/2021 10/01/2021
Sewer Service Inspection - R Passed 10/7/2021 10/07/2021
Water Service Inspection - R Partial 10/7/2021 10/07/2021
Piers/Caissons Inspection - Residential Passed 10/8/2021 10/08/2021
Erosion Control Inspection Residential Failed 10/13/2021 10/13/2021 10/13/2021
Misc
Corrective Action Required
10/13/2021
EROSION CONTROL NEEDS TO BE PUT IN PLACE
Water Service Inspection - R Passed 10/14/2021 (1:00) 10/14/2021 10/14/2021
Erosion Control Inspection Residential Passed 10/21/2021 10/21/2021 10/20/2021
Misc
Resolved
10/20/2021
EROSION CONTROL NEEDS TO BE PUT IN PLACE
Misc
Informational
10/20/2021
10-20-21 AN contractor has put silt fencing in place to control erosion.
Misc
Informational
10/20/2021
10-20-21 AN contractor has put silt fencing in place to control erosion.
All Rough Inspection - Residential Failed 2/2/2022 2/2/2022 02/02/2022
Misc
Corrective Action Required
02/02/2022
-Protect wiring within 6 ft of attic access above 3rd car garage -Provide min two 1/2” anchors for garage column -Support 3” drain in garage soffit at max 4 ft -Provide full support for double joists at garage/laundry wall -Fb duct chase at master bathroom shower from ceiling space; Fb dead spaces in master bathroom from joist and soffit space -Pan off return air space from dead space between laundry and master bathroom -Nail corner studs per code 16d@12” oc or equivalent nailing -Land roof load above master bedroom to bearing wall per plan; install triple 2x12 ceiling beam -Fb gaps at top of fireplace space -Plan calls for double 11-7/8” LVL beam at rear great room wall. Currently triple 2x10 installed. Have engineer verify beam size -Install deck door -Fb 2nd fl duct chase from roof -At 2nd fl bathroom, staple wiring min 1.25” away from stud nailing surface -Install hanger for bedroom 2 ceiling beam connection near window -Install triple 2x10 at basement per plan (under master closet). Provide full support at exterior wall end -Solid block underneath all point loads at laundry wall down to I beam below -Block cantilevered joists -Fb gaps at vertical fire blockings. Use 3/4” sheathing for fire blocking; vertical fire blockings must be no more than ten ft apart, including wall space above windows. -Security blocking for basement walkout door -Pan off return air space above basement rec rm/bedroom wall from soffit space -Install 4” duct for basement bathroom fan -Fb basement bedroom 4 wall from closet soffit -Protect water line at bedroom 4 closet wall top plate **OK TO INSULATE
Electrical Service Inspection Passed 2/2/2022 2/2/2022 02/02/2022
Gas Service Inspection - Residential Passed 2/2/2022 2/2/2022 02/02/2022
Misc
Resolved
02/02/2022
All Rough Inspection - Residential Failed 2/9/2022 2/9/2022 02/09/2022
Misc
Corrective Action Required
02/02/2022
-Provide min two 1/2” anchors for garage column -Support 3” drain in garage soffit at max 4 ft -Provide full support for double joists at garage/laundry wall -Fb duct chase at master bathroom shower from ceiling space; Fb dead spaces in master bathroom from joist and soffit space -Pan off return air space from dead space between laundry and master bathroom -Nail corner studs per code 16d@12” oc or equivalent nailing -Land roof load above master bedroom to bearing wall per plan; install triple 2x12 ceiling beam -Fb gaps at top of fireplace space -Plan calls for double 11-7/8” LVL beam at rear great room wall. Currently triple 2x10 installed. Have engineer verify beam size -Install deck door -Fb 2nd fl duct chase from roof -At 2nd fl bathroom, staple wiring min 1.25” away from stud nailing surface -Install hanger for bedroom 2 ceiling beam connection near window -Install triple 2x10 at basement per plan (under master closet). Provide full support at exterior wall end -Solid block underneath all point loads at laundry wall down to I beam below -Block cantilevered joists -Fb gaps at vertical fire blockings. Use 3/4” sheathing for fire blocking; vertical fire blockings must be no more than ten ft apart, including wall space above windows. -Security blocking for basement walkout door -Pan off return air space above basement rec rm/bedroom wall from soffit space -Install 4” duct for basement bathroom fan -Fb basement bedroom 4 wall from closet soffit -Protect water line at bedroom 4 closet wall top plate **OK TO INSULATE **2/9/22-THIS IS A 2ND FAILED INSPECTION
Driveway Inspection Partial 2/15/2022 2/15/2022 02/15/2022
Misc
Informational
02/15/2022
2-15-22 AN forms are in place and aggregate is present and compacted.no sidewalk
All Rough Inspection - Residential Not Ready 2/16/2022 2/16/2022 02/16/2022
Misc
Corrective Action Required
02/09/2022
-Provide min two 1/2” anchors for garage column -Support 3” drain in garage soffit at max 4 ft -Fb duct chase at master bathroom shower from ceiling space; Fb dead spaces in master bathroom from joist and soffit space -Nail corner studs per code 16d@12” oc or equivalent nailing -Land roof load above master bedroom to bearing wall per plan; install triple 2x12 ceiling beam -Plan calls for double 11-7/8” LVL beam at rear great room wall. Currently triple 2x10 installed. Have engineer verify beam size -Install deck door per security code. Shim gap at strike plate side and security block at strike plate height -At 2nd fl bathroom, staple wiring min 1.25” away from stud nailing surface -Install triple 2x10 at basement per plan (under master closet). Provide full support at exterior wall end -Solid block underneath all point loads at laundry wall down to I beam below -Block cantilevered joists -Fb gaps at vertical fire blockings. Use 3/4” sheathing for fire blocking; vertical fire blockings must be no more than ten ft apart, including wall space above windows. -Security blocking for basement walkout door at strike plate height; fill in gap at hinges and strike plate side with solid wood per security code -Fb basement bedroom 4 wall from closet soffit -Protect water line at bedroom 4 closet wall top plate **OK TO INSULATE **2/9/22-THIS IS A 2ND FAILED INSPECTION **2/16/22-REINSPECTION FEE ASSESSED
All Rough Inspection - Residential Not Ready 2/22/2022 2/22/2022 02/22/2022
Misc
Corrective Action Required
02/16/2022
-Support 3” drain in garage soffit at max 4 ft -Provide triple ceiling beam above master bedroom per plan. This beam is supposed to carry roof load, not the master bedroom/closet wall, which is not a bearing wall. -Plan calls for double 11-7/8” LVL beam at rear great room wall. Currently triple 2x10 installed. Have engineer verify beam size -Install deck door per security code. Shim gap at strike plate side and security block at strike plate height -At 2nd fl bathroom, staple wiring min 1.25” away from stud nailing surface **bedroom 3/bathroom wall -Install triple 2x10 at basement per plan (under master closet). Provide full support at exterior wall end -Fb gaps at vertical fire blockings. Use 3/4” sheathing for fire blocking; vertical fire blockings must be no more than ten ft apart, including wall space above windows. **fb gaps at vertical fire blockings. Use 3/4” sheathing or other approved material -Security blocking for basement walkout door at strike plate height; fill in gap at hinges and strike plate side with solid wood per security code -Fb basement bedroom 4 wall from closet soffit **pack insulation in gap -Protect water line at bedroom 4 closet wall top plate **not done **OK TO INSULATE **2/9/22-THIS IS A 2ND FAILED INSPECTION **2/16/22-REINSPECTION FEE ASSESSED **2/22/22-REINSPECTION FEE ASSESSED
All Rough Inspection - Residential Not Ready 2/25/2022 2/25/2022 02/25/2022
Misc
Corrective Action Required
02/22/2022
-Plan calls for double 11-7/8” LVL beam at rear great room wall. Currently triple 2x10 installed. **An outer 2x10 was replaced by a 9.5” lvl ply. Have engineer ok/address this -Install triple 2x10 at basement per plan (under master closet). Provide full support at exterior wall end **Provide full stud support for beam at exterior wall; reinstall electrical -Fb gaps at vertical fire blockings. Use 3/4” sheathing for fire blocking; vertical fire blockings must be no more than ten ft apart, including wall space above windows. **fb gaps at vertical fire blockings. Use 3/4” sheathing or other approved material -Security blocking for basement walkout door at strike plate height; fill in gap at hinges and strike plate side with solid wood per security code -Fb basement bedroom 4 wall from closet soffit **pack insulation in gap **OK TO INSULATE **2/9/22-THIS IS A 2ND FAILED INSPECTION **2/16/22-REINSPECTION FEE ASSESSED **2/22/22-REINSPECTION FEE ASSESSED **2/25/22-REINSPECTION FEE ASSESSED
Driveway Inspection Passed 2/25/2022 2/25/2022 02/28/2022
Misc
Informational
02/15/2022
2-15-22 AN forms are in place and aggregate is present and compacted.no sidewalk
Misc
Informational
02/28/2022
2-28-22 AN driveway looks good and has expansion joints at curb and right of way
All Rough Inspection - Residential Not Ready 3/1/2022 3/1/2022 03/01/2022
Misc
Corrective Action Required
02/25/2022
-Fb gaps at vertical fire blockings. Use 3/4” sheathing for fire blocking; vertical fire blockings must be no more than ten ft apart, including wall space above windows. **fb gaps at vertical fire blockings. Use 3/4” sheathing or other approved material **Look at the gaps at top and bottom of the vertical fire blockings. Please close these gaps with proper material, like insulation, etc -Fb basement bedroom 4 wall from closet soffit **pack insulation in gap **OK TO INSULATE **2/9/22-THIS IS A 2ND FAILED INSPECTION **2/16/22-REINSPECTION FEE ASSESSED **2/22/22-REINSPECTION FEE ASSESSED **2/25/22-REINSPECTION FEE ASSESSED **3/1/22-REINSPECTION FEE ASSESSED
All Rough Inspection - Residential Passed 3/4/2022 3/4/2022 03/04/2022
Misc
Informational
03/04/2022
**OK TO ROCK **2/9/22-THIS IS A 2ND FAILED INSPECTION **2/16/22-REINSPECTION FEE ASSESSED **2/22/22-REINSPECTION FEE ASSESSED **2/25/22-REINSPECTION FEE ASSESSED **3/1/22-REINSPECTION FEE ASSESSED
Erosion Control Inspection Residential Failed 03/23/2022
Misc
Corrective Action Required
03/23/2022
3-23-22 AN silt fence needs to be repaired
Erosion Control Inspection Residential Passed 3/28/2022 3/28/2022 03/29/2022
Misc
Resolved
03/29/2022
3-23-22 AN silt fence needs to be repaired
Misc
Informational
03/29/2022
3-29-22 AN erosion control issue has been resolved.
Occupancy Inspection - Codes Residential Failed 9/19/2022 9/19/2022 09/19/2022
Misc
Corrective Action Required
09/19/2022
-Obtain lawn irrigation permit and submit backflow valve test report to city -are-inspection fees must be paid in full prior to any occupancy -As-graded plot plan is required -Provide sewer tracer wire port at grade -Garage door not self-closing -2nd fl rear bathroom receptacle not gfci-protected -Stair to basement, provide min 6’8” headroom clearance from light above stair, or install luminaire no more than 4” protruding from wall -Screw the basement exterior door embedded jamb brace into studs -Install sump pump cover -Support lawn irrigation pex line every 32” horizontally -Fb floor at master bathroom tub trap above sump pump -Install airtight cap for the sewer clean out
Occupancy Inspection - Codes Residential Failed 9/27/2022 9/27/2022 09/27/2022
Misc
Corrective Action Required
09/19/2022
-Obtain lawn irrigation permit and submit backflow valve test report to city -All not-ready-inspection fees must be paid in full prior to any occupancy -Provide sewer tracer wire port at grade -Install airtight plug for the sewer clean out. The clean out plug must conform to requirements of IRC P3005.2.6. The plug must have a raised square head, a countersunk square head, or a counter sunk slotted head
Plot Plan Inspection Passed 9/27/2022 09/27/2022
Occupancy Inspection - Codes Residential Full C of O 9/28/2022 9/28/2022 09/28/2022
Misc
Resolved
09/28/2022
-Obtain lawn irrigation permit and submit backflow valve test report to city
Documents & Images
Date Uploaded File Type Document Name
08/04/2021 Lot 152 Residental Permit Application_1
08/04/2021 Lot 152 License_Tax_Application
08/05/2021 Approved Plans Approved Drawings
08/05/2021 Permit Codes Residential Plan Review
08/05/2021 Plot Plan Approved Plot Plan
08/05/2021 Permit Codes Residential Plan Review
08/09/2021 Permit DS Building Permit
08/09/2021 Receipt Receipt for transaction: 2021-006325
08/23/2021 M L Crose 4716 NE Freehold Dr LSMO Monticello Lot 152 NZC Permit 2021-4054 3rd Party Footing Inspection Report 8-19-21
08/24/2021 Letter INSPECTION SUMMARY
09/21/2021 Approved Plans Approved Revised Drawings
10/01/2021 Letter INSPECTION SUMMARY
10/07/2021 Letter INSPECTION SUMMARY
10/07/2021 Letter INSPECTION SUMMARY
10/08/2021 Letter INSPECTION SUMMARY
10/13/2021 Letter INSPECTION SUMMARY
10/14/2021 Letter INSPECTION SUMMARY
10/20/2021 Letter INSPECTION SUMMARY
10/25/2021 Letter INSPECTION SUMMARY
02/02/2022 Letter INSPECTION SUMMARY
02/02/2022 Letter INSPECTION SUMMARY
02/02/2022 Letter INSPECTION SUMMARY
02/02/2022 Letter INSPECTION SUMMARY
02/09/2022 Letter INSPECTION SUMMARY
02/15/2022 Letter INSPECTION SUMMARY
02/16/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
02/25/2022 Letter INSPECTION SUMMARY
02/28/2022 Letter INSPECTION SUMMARY
03/01/2022 Letter INSPECTION SUMMARY
03/04/2022 Letter INSPECTION SUMMARY
03/23/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
09/19/2022 Letter INSPECTION SUMMARY
09/27/2022 Plot Plan Approved As Graded Plot Plan
09/27/2022 Letter INSPECTION SUMMARY
09/27/2022 Letter INSPECTION SUMMARY
09/28/2022 Receipt Receipt for transaction: 2022-007861
09/28/2022 Letter Codes Final Certificate of Occupancy
09/28/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home