Permit Application Status

PRRES20213997


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213997
Building Permit - Residential
Certificate of Occupancy
JOHN KNOX VILLAGE
NEW DUPLEX
NEW DUPLEX - UNFINISHED BASEMENT - THREE SEASON ROOM WAITING FOR PLOT PLAN AND MINOR PLAT TO BE RECORDED
08/02/2021
10/04/2021
02/05/2022
08/26/2022
Locations
Contacts
JOHN KNOX VILLAGE, Address:400 NW MURRAY RD, Phone:(816) 347-2855  
MSMITH@JKV.ORG  
JOHN KNOX VILLAGE, Address:400 NW MURRAY RD  
LARRY HARKRADER CONSTRUCTION, Address:401 NW MURRAY RD, Phone:(816) 607-7191  
  
  
  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Duplex $1,557.94 $1,557.94 Paid 10/04/2021
$565.76
Residential Excise Tax Fee $565.76 $565.76 Paid 08/03/2021
$565.76
8331507-Sewer Connection Fee $720.00 $720.00 Paid 10/04/2021
Not Ready Inspection Fee $50.00 $50.00 Paid 07/14/2022
Temporary Occupancy Fee $50.00 $50.00 Paid 08/02/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/26/2021 10/26/2021
Misc
Informational
10/26/2021
BOTH UFERS LOCATED WEST FOUNDATION WALL
Underslab Plumbing Inspection - Residential Partial 11/30/2021 11/30/2021
Misc
Informational
11/30/2021
- PARTIAL FLOOR DRAINS & INTERIOR DRAIN TILE IN BASEMENT BOTH UNITS COMPLETE OK TO COVER - - FLOOR DRAIN IN GARAGE NOT COMPLETE AT THIS TIME -
Water Service Inspection - R Partial 12/15/2021 (10:15) 12/15/2021 12/15/2021
Misc
Informational
12/15/2021
PROVIDE ADDRESS PARTIAL WATER FOUNDATION TO EAST GARAGE BOTH UNITS NO METER PIT AT HTIS TIME
Sewer Service Inspection - R Partial 12/15/2021 (10:15) 12/15/2021 12/15/2021
Misc
Informational
12/15/2021
PROVIDE ADDRESS PARTIAL WEST UNIT FOUNDATION PAST EAST UNIT GARAGE NO SEWER LINES COMPLETE ON EAST UNIT
Sewer Service Inspection - R Partial 12/16/2021 (10:45) 12/16/2021 12/16/2021
Misc
Informational
12/15/2021
PROVIDE ADDRESS PARTIAL WEST UNIT & EAST UNIT RUN TO FOUNDATION WALL EAST SIDE NEED TO COMPLETE TO MAIN
Sewer Service Inspection - R Passed 12/16/2021 12/16/2021
Misc
Informational
12/16/2021
PROVIDE ADDRESS WEST UNIT & EAST UNIT RUN TO FOUNDATION WALL EAST SIDE COMPLETE TO MAIN
Water Service Inspection - R Passed 12/17/2021 (10:30) 12/17/2021 12/17/2021
Misc
Informational
12/15/2021
PROVIDE ADDRESS PARTIAL WATER FOUNDATION TO EAST GARAGE BOTH UNITS. ONE METER PIT FOR BOTH UNITS
Underslab Plumbing Inspection - Residential Passed 4/4/2022 4/4/2022 04/04/2022
Misc
Informational
11/30/2021
- PARTIAL FLOOR DRAINS & INTERIOR DRAIN TILE IN BASEMENT BOTH UNITS COMPLETE OK TO COVER - - 4/4/22 FLOOR DRAINS IN GARAGES -
Electrical Service Inspection Failed 5/11/2022 05/11/2022
Miscellaneous Correction
Corrective Action Required
05/11/2022
Derate feeder cables in attic for ambient temperatures ( 2017 NEC 310.15 ) Provide meter can/ disconnect Land SEC cables in meter can
All Rough Inspection - Residential Failed 5/11/2022 5/11/2022 05/11/2022
Miscellaneous Correction
Corrective Action Required
05/11/2022
:: Unit B West :: Provide ufer access garage Provide anchor bolts SCH 40 columns Fire block tub traps Provide LIBs or have GB method inspected with rated assembly Seal upward penetrations near service panel Provide nail guard NM kitchen/ dining & seasonal room Secure gas line fireplaces Seal penetrations fireplace Seal upwards ard penetration left of fireplace Address rafters landing on blocks (ceiling joist rafter connection) Seal floor penetration laundry room Complete B vent to roof Strap B vent laundry Seal upward penetration master closet Seal upward penetration master bath Address rated wall at master vanity shower ( Whats the plan? no prerock) Provide 2 9 1/4 LVLS at basement nitch per plan :: Unit A East code :: • Anchor bolts SCH 40 columns • Provide (2) 9 1/4 LVLs at basement nitch per plan • Address rafters landing on blocks • LIBs or Gyp method • Secure gas line fireplace • Seal penetrations fireplace • Seal upward penetration living room • Seal upward penetration pvc master • Fire block furr out master vanity • Protection plates kitchen above service panel
Gas Service Inspection - Residential Passed 5/13/2022 05/13/2022
Misc
Informational
05/13/2022
UNITS A & B APPROVED
All Rough Inspection - Residential Not Ready 5/13/2022 5/13/2022 05/13/2022
Miscellaneous Correction
Corrective Action Required
05/11/2022
:: Unit B West :: Provide ufer access garage (COF) Provide LIBs or have GB method inspected with rated assembly screw pattern Provide nail guard NM kitchen ( corner near service panel ) & seasonal room ( corner & under window) Address rated wall at master vanity shower ( Whats the plan? no prerock) Provide (2) 9 1/4 LVLS at basement nitch per plan : INSTALLED (2) TJ210 ENGINEER TO ADDRESS : :: Unit A East side :: • Provide (2) 9 1/4 LVLs at basement nitch per plan ( Engineer to address ) • LIBs or Gyp method ( screw pattern rated assembly)
All Rough Inspection - Residential Failed 5/16/2022 5/16/2022 05/16/2022
Miscellaneous Correction
Corrective Action Required
05/13/2022
:: Unit B West :: Provide ufer access garage (COF) Provide LIBs or have GB method inspected with rated assembly screw pattern Provide (2) 9 1/4 LVLS at basement nitch per plan : INSTALLED (2) LSL JOIST ENGINEER TO ADDRESS : :: Unit A East side :: • Provide (2) 9 1/4 LVLs at basement nitch per plan ( Engineer to address (2) LSL joist installed • LIBs or Gyp method ( screw pattern rated assembly) :: Ok to insulate & Sheetrock ::
Rated Assembly Inspection Partial 5/20/2022 5/20/2022 05/20/2022
Misc
Corrective Action Required
05/20/2022
UNIT A 1ST LAYER 5/8 TYPE X SCREW PATTERN WALLS & RAFTERS APPROVED : NEED TO CHECK SCREW PATTERN GB METHOD AT LIBs WITH 2ND LAYER UNIT B 1ST LAYER 5/8 TYPE X SCREW PATTERN WALLS & RAFTERS APPROVED : NEED TO CHECK SCREW PATTERN ON GB METHOD AT LIBs WITH 2ND LAYER
Electrical Service Inspection Partial 5/20/2022 5/20/2022 05/20/2022
Miscellaneous Correction
Corrective Action Required
05/11/2022
Derate feeder cables in attic for ambient temperatures ( 2017 NEC 310.15 ) OK TO RELEASE METERS UNITS A & B
Rated Assembly Inspection Partial 5/23/2022 5/23/2022 05/23/2022
Misc
Corrective Action Required
05/20/2022
UNIT A 1ST LAYER 5/8 TYPE X SCREW PATTERN WALLS & RAFTERS APPROVED UNIT A 2ND LAYER 5/8 TYPE X SCREW PATTERN & FIRE CAULK : NEED TO CHECK SCREW PATTERN GB METHOD AT LIBs WITH 2ND LAYER UNIT B 1ST LAYER 5/8 TYPE X SCREW PATTERN WALLS & RAFTERS APPROVED UNIT B 2ND LAYER 5/8 TYPE X SCREW PATTERN & FIRE CAULK : NEED TO CHECK SCREW PATTERN ON GB METHOD AT LIBs WITH 2ND LAYER
Rated Assembly Inspection Passed 5/25/2022 05/25/2022
Misc
Corrective Action Required
05/23/2022
UNIT A 1ST LAYER 5/8 TYPE X SCREW PATTERN WALLS & RAFTERS APPROVED UNIT A 2ND LAYER 5/8 TYPE X SCREW PATTERN & FIRE CAULK : SCREW PATTERN GB METHOD AT LIBs APPROVED UNIT B 1ST LAYER 5/8 TYPE X SCREW PATTERN WALLS & RAFTERS APPROVED UNIT B 2ND LAYER 5/8 TYPE X SCREW PATTERN & FIRE CAULK : SCREW PATTERN ON GB METHOD AT LIBs APPROVED :
All Rough Inspection - Residential Failed 5/25/2022 5/25/2022 05/25/2022
Miscellaneous Correction
Corrective Action Required
05/16/2022
:: Unit B West :: Provide ufer access garage (COF) Provide (2) 9 1/4 LVLS at basement nitch per plan : INSTALLED (2) LSL JOIST ENGINEER TO ADDRESS : :: Unit A East side :: • Provide (2) 9 1/4 LVLs at basement nitch per plan ( Engineer to address (2) LSL joist installed :: Ok to insulate & Sheetrock :: - SCREW PATTERN GB METHOD INLO LIBs APPROVED
Erosion Control Inspection Residential Passed 07/01/2022
Occupancy Inspection - Codes Residential Failed 7/1/2022 7/1/2022 07/01/2022
Misc
Corrective Action Required
07/01/2022
605 nw redbud unit A Electrical service inspection failed and needs re inspection AFCI protection required provide engineers letter to address (2) LSL joist installed at basement nitch when plans call for an LVL Splash blocks Provide sod Attach AC whip within 12” of disconnect No GFCI protection on any garage outlets Provide spark rings on kitchen counter outlets Missing outlet covers and incomplete electrical box in kitchen GFCI outlet in hall bathroom wired incorrectly will not trip and shows open neutral Outlet in laundry not GFCI protected Outlets in master bathroom incomplete And GFCI not working Basement outlets are not GFCI protected Label non gfci outlets Unit B outlet on front porch dead Outlets in garage not GFCI protected Outlet in hall bathroom missing cover Laundry room not GFCI protected Master bathroom outlets not complete Outlets and switches in kitchen incomplete Sod and splash blocks GFCI protected outlets required in basement Label non gfci outlets Add gravel to Egress window pit Provide engineers letter for (2) 9 1/4” LSL at basement nitch when plan calls for LVLS
Occupancy Inspection - Codes Residential Failed 7/6/2022 7/6/2022 07/06/2022
Misc
Corrective Action Required
07/01/2022
605 nw redbud unit A Electrical service inspection failed and needs re inspection provide engineers letter to address (2) LSL joist installed at basement nitch when plans call for an LVL Splash blocks Provide sod Island outlet not gfci protected E3902.9 Laundry areas. 125-volt, single-phase, 15- and 20- ampere receptacles installed in laundry areas shall have ground- fault circuit-interrupter protection for personnel. [210.8(A)(9)] E3902.10 Kitchen dishwasher branch circuit. Ground-fault circuit-interrupter protection shall be provided for outlets that supply dishwashers in dwelling unit locations. [210.8(D)] No GFCI protection on dishwasher Outlet in laundry not GFCI protected Unit B E3902.9 Laundry areas. 125-volt, single-phase, 15- and 20- ampere receptacles installed in laundry areas shall have ground- fault circuit-interrupter protection for personnel. [210.8(A)(9)] E3902.10 Kitchen dishwasher branch circuit. Ground-fault circuit-interrupter protection shall be provided for outlets that supply dishwashers in dwelling unit locations. [210.8(D)] Outlets at Island not gfci protected Outlet at dishwasher not gfci protected Laundry room not GFCI protected Sod and splash blocks Provide engineers letter for (2) 9 1/4” LSL at basement nitch when plan calls for LVLS
Occupancy Inspection - Codes Residential Failed 7/8/2022 7/8/2022 07/08/2022
Misc
Corrective Action Required
07/06/2022
605 nw redbud unit A Electrical service inspection failed and needs re inspection provide engineers letter to address (2) LSL joist installed at basement nitch when plans call for an LVL Splash blocks Provide sod Island outlet not gfci protected E3902.9 Laundry areas. 125-volt, single-phase, 15- and 20- ampere receptacles installed in laundry areas shall have ground- fault circuit-interrupter protection for personnel. [210.8(A)(9)] E3902.10 Kitchen dishwasher branch circuit. Ground-fault circuit-interrupter protection shall be provided for outlets that supply dishwashers in dwelling unit locations. [210.8(D)] No GFCI protection on dishwasher Outlet in laundry not GFCI protected Unit B E3902.9 Laundry areas. 125-volt, single-phase, 15- and 20- ampere receptacles installed in laundry areas shall have ground- fault circuit-interrupter protection for personnel. [210.8(A)(9)] E3902.10 Kitchen dishwasher branch circuit. Ground-fault circuit-interrupter protection shall be provided for outlets that supply dishwashers in dwelling unit locations. [210.8(D)] Outlets at Island not gfci protected Outlet at dishwasher not gfci protected Laundry room not GFCI protected Sod and splash blocks Provide engineers letter for (2) 9 1/4” LSL at basement nitch when plan calls for LVLS
Misc
Corrective Action Required
07/08/2022
inspection denied untill the rough-in and electrical have been addressed. The note to Mike Weisenborn , Mike is a project manger and is not a building inspector or the manager of building inspections. . contact Mark harding at 969-1216 Note" We are trying to resolve the derating issue but apparently there are no smaller 150amp breakers period. This is the first time we have ever had to do this. We have a call in to Mike Wisenborn and are waiting on how he recommends us resolving this issue." MARK HARDING 07/08/2022 7:38 AM
All Rough Inspection - Residential Passed 7/14/2022 07/14/2022
Miscellaneous Correction
Resolved
07/14/2022
:: Unit B West :: Provide ufer access garage (COF) Provide (2) 9 1/4 LVLS at basement nitch per plan : INSTALLED (2) LSL JOIST ENGINEER TO ADDRESS : :: Unit A East side :: • Provide (2) 9 1/4 LVLs at basement nitch per plan ( Engineer to address (2) LSL joist installed :: Ok to insulate & Sheetrock :: - SCREW PATTERN GB METHOD INLO LIBs APPROVED
Electrical Service Inspection Failed 7/14/2022 07/14/2022
Miscellaneous Correction
Corrective Action Required
05/20/2022
Derate feeder cables in attic for ambient temperatures ( 2017 NEC 310.15 ) OK TO RELEASE METERS UNITS A & B UNIT A NEEDS DERATED UNIT B IS COMPLETE
Occupancy Inspection - Codes Residential Failed 7/14/2022 7/14/2022 07/14/2022
Misc
Corrective Action Required
07/08/2022
605 nw redbud unit A -Electrical service inspection failed and needs re inspection -Splash blocks Provide sod Unit B -Sod and splash blocks
Misc
Corrective Action Required
07/14/2022
inspection denied untill the rough-in and electrical have been addressed. The note to Mike Weisenborn , Mike is a project manger and is not a building inspector or the manager of building inspections. . contact Mark harding at 969-1216 Note" We are trying to resolve the derating issue but apparently there are no smaller 150amp breakers period. This is the first time we have ever had to do this. We have a call in to Mike Wisenborn and are waiting on how he recommends us resolving this issue." MARK HARDING 07/08/2022 7:38 AM
Electrical Service Inspection Passed 07/15/2022
Miscellaneous Correction
Informational
07/15/2022
Derate feeder cables in attic for ambient temperatures ( 2017 NEC 310.15 ) OK TO RELEASE METERS UNITS A & B UNIT A at disconnect outside UNIT B IS COMPLETE
Occupancy Inspection - Codes Residential Ready for Temp CO 7/15/2022 7/15/2022 07/15/2022
Misc
Corrective Action Required
07/14/2022
605 nw redbud unit A -Splash blocks Provide sod Unit B -Sod and splash blocks TCO for both A & B units
Misc
Resolved
07/15/2022
Occupancy Inspection - Codes Residential Temporary C of O 08/02/2022
Misc
Corrective Action Required
07/15/2022
605 nw redbud unit A -Splash blocks Provide sod Unit B -Sod and splash blocks
Plot Plan Inspection Passed 08/26/2022
Occupancy Inspection - Codes Residential Full C of O 8/26/2022 8/26/2022 08/26/2022
Misc
Resolved
08/26/2022
Documents & Images
Date Uploaded File Type Document Name
08/02/2021 Application Form Permit Application
08/04/2021 2021_07_14 JKV Duplex_Permit Sets_Sealed
08/06/2021 Permit Codes Residential Plan Review
08/09/2021 Permit Codes Residential Plan Review
08/09/2021 Permit Codes Residential Plan Review
08/09/2021 Permit Codes Residential Plan Review
09/21/2021 excise tax 605 redbud
09/21/2021 Plot Plan Approved Plot Plan
09/27/2021 City-L-092721
09/27/2021 Approved Plans Approved Drawings
09/27/2021 Permit Codes Residential Plan Review
10/04/2021 Permit DS Building Permit
10/04/2021 Receipt Receipt for transaction:2021-007768
10/26/2021 Letter INSPECTION SUMMARY
11/30/2021 Letter INSPECTION SUMMARY
12/15/2021 Letter INSPECTION SUMMARY
12/15/2021 Letter INSPECTION SUMMARY
12/16/2021 Letter INSPECTION SUMMARY
12/16/2021 Letter INSPECTION SUMMARY
12/17/2021 Letter INSPECTION SUMMARY
04/04/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/13/2022 Letter INSPECTION SUMMARY
05/13/2022 Letter INSPECTION SUMMARY
05/16/2022 Letter INSPECTION SUMMARY
05/20/2022 Letter INSPECTION SUMMARY
05/20/2022 Letter INSPECTION SUMMARY
05/23/2022 Letter INSPECTION SUMMARY
05/25/2022 Letter INSPECTION SUMMARY
05/25/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter INSPECTION SUMMARY
07/06/2022 Letter INSPECTION SUMMARY
07/08/2022 Letter INSPECTION SUMMARY
07/11/2022 2022_07_06_605 NW Redbud Dr Framing
07/14/2022 Receipt Receipt for transaction:2022-005761
07/14/2022 Letter INSPECTION SUMMARY
07/14/2022 Letter INSPECTION SUMMARY
07/14/2022 Letter INSPECTION SUMMARY
07/15/2022 Letter INSPECTION SUMMARY
08/02/2022 Receipt Receipt for transaction:2022-006316
08/02/2022 Letter Codes Temporary Certificate of Occupancy
08/26/2022 Letter INSPECTION SUMMARY
08/26/2022 Letter Field Certificate of Occupancy
08/26/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home