Permit Application Status

PRRES20213583


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213583
Building Permit - Residential
Certificate of Occupancy
NEW DUPLEX
NEW DUPLEX - UNFINISHED BASEMENT - UNCOVERED DECK
07/12/2021
07/13/2021
01/09/2022
08/09/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JASONH@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Duplex $2,015.24 $2,015.24 Paid 07/13/2021
8331507-Sewer Connection Fee $900.00 $900.00 Paid 07/13/2021
8331401-Water Tap Fee $7,310.00 $7,310.00 Paid 07/13/2021
8350015-Water Meter Fee $958.48 $958.48 Paid 07/13/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 07/13/2021
7232302-Residential Excise Tax Fee $2,154.24 $2,154.24 Paid 07/13/2021
8331504-EFHB Middle Big Creek, Full $1,004.40 $1,004.40 Paid 10/22/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/28/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/28/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/28/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/28/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/28/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 08/03/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/24/2021 8/24/2021 08/24/2021
Misc
Informational
08/24/2021
APPROVED PER DAVID AINSWORTH 8/18/21
Underslab Plumbing Inspection - Residential Failed 9/17/2021 9/17/2021 09/17/2021
Misc
Corrective Action Required
09/17/2021
COMPLETE WASTE LINE TO FOOTING ON 3825 AND 3823
Underslab Plumbing Inspection - Residential Passed 9/21/2021 9/21/2021 09/21/2021
Misc
Resolved
09/21/2021
Sewer Service Inspection - R Partial 10/19/2021 (1:00) 10/19/2021 10/19/2021
Misc
Informational
10/19/2021
3823 OK
Footing Inspection - Residential Failed 10/19/2021 10/19/2021 10/19/2021
Misc
Corrective Action Required
10/19/2021
FOOTING HAS BEEN UNDERMINED ALONG RIGHT SIDE OF HOUSE FOR SEWER LINE TRENCH, SUBMIT ENGINEER REPORT
Water Service Inspection - R Partial 10/25/2021 (10:00) 10/25/2021 10/25/2021
Misc
Informational
10/25/2021
3823 OK 3825 OK
Sewer Service Inspection - R Passed 11/1/2021 (9:30) 11/1/2021 11/01/2021
Misc
Informational
10/19/2021
3823, 3825 OK
Footing Inspection - Residential Passed 11/3/2021 11/3/2021 11/03/2021
Misc
Resolved
11/03/2021
FOOTING HAS BEEN UNDERMINED ALONG RIGHT SIDE OF HOUSE FOR SEWER LINE TRENCH, SUBMIT ENGINEER REPORT
Water Service Inspection - R Passed 11/3/2021 11/03/2021
Misc
Informational
10/25/2021
3823 OK 3825 OK
Erosion Control Inspection Residential Failed 3/2/2022 3/2/2022 03/02/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/02/2022
DEFICIENT EROSION CONTROL INSTALLATION. -MAINTAIN GRAVEL FILTER TO HOUSE, USE MIN. 6" LIFT OF MIN. 3/4" GRAVEL, CLEAN DEBRIS FROM STREET
Gas Service Inspection - Residential Not Ready 3/2/2022 3/2/2022 03/02/2022
Misc
Corrective Action Required
03/02/2022
-NO PRESSURE AT GAUGE -METALLIC LINE MUST BE BONDED TO GROUNDING ELECTRODE SYSTEM
Electrical Service Inspection Failed 3/9/2022 3/9/2022 03/09/2022
Misc
Corrective Action Required
03/09/2022
PROVIDE UFER GROUND AT SERVICE AS REQUIRED BY CODE E3608.1.2
Gas Service Inspection - Residential Failed 3/9/2022 3/9/2022 03/09/2022
Misc
Corrective Action Required
03/02/2022
3823 - GAS PRESSURE 0 PSI, MUST MAINTAIN 10 PSI FOR TEST 3825 - PRESSURE OK
All Rough Inspection - Residential Failed 3/9/2022 3/9/2022 03/09/2022
Misc
Corrective Action Required
03/09/2022
UNIT 3825 -nail exterior Sheathing for garage PFH per plans/R602.10.6.4 -nail exterior sheathing per plans -fur down at HVAC garage to allow for insulation -remove fur down soffit corner at garage rated wall against studs, will need to pre rock 1/2” rock per plans to maintain UL rating -fireblock between top plate and rock at air gap -fireblock vertical every 10’ between stud and fire rock at air gap throughout -fireblock Plumbing/HVAC at fur out garage wall -seal top plate penetrations -1st floor 1/2 bath -add structural straps at all top plates bored 50% or more on all exterior walls and interior load bearing walls -solid shim all trimmer studs short of header and studs short of top or bottom plate throughout -LIB bracing all locations per plans -(2) 2x4 trimmers at (2)2x10 header garage door per plans -repair damaged sections of fire rock at 2nd floor also cannot scab on smart siding to repair damaged sections of rated fire rock -edges of fire rock are required to be seated in the H channel studs per plans -breakaway clip spacing and attachment per plans -fire rock must extend to roof decking in C channel per plans -clarify UL design for attic fire rated wall -No openings, vents or gaps in fire rated plywood at roof deck within 4’ of fire rated wall -fireblock at top plate between furring strips at rear stair wall 2nd floor -address penetrations through firewall at basement, see detail on page A7.1 of plans -1/2” rock will need to be prerocked when approved at 2nd floor bath at tub against fire rated separation wall, rock cont on wall per UL design -confirm 1/2” rock placement at dbl wall 2nd floor bath at fire rated wall to maintain listed UL requirements and code -fire rated separation required between units at daylight wall basement R302.3 UNIT 3823 -See above corrections list from 3825 and additional corrections listed below -solid block all sheathing breaks at step flashing -provide electrical receptacle at unfinished basement -provide future plumbing vent at basement
Rated Assembly Inspection Failed 3/9/2022 3/9/2022 03/09/2022
Misc
Corrective Action Required
03/09/2022
-remove fur down soffit corner at garage rated wall against studs, will need to pre rock 1/2” rock per plans to maintain UL rating -repair damaged sections of fire rock at 2nd floor also cannot scab on smart siding to repair damaged sections of rated fire rock -edges of fire rock are required to be seated in the H channel studs per plans -breakaway clip spacing and attachment per plans -fire rock must extend to roof decking in C channel per plans -clarify UL design for attic fire rated wall -No openings, vents or gaps in fire rated plywood at roof deck within 4’ of fire rated wall -address penetrations through firewall at basement, see detail on page A7.1 of plans -1/2” rock will need to be prerocked when approved at 2nd floor bath at tub against fire rated separation wall, rock cont on wall per UL design -confirm 1/2” rock placement at dbl wall 2nd floor bath at fire rated wall to maintain listed UL requirements and code -fire rated separation required between units at daylight wall basement R302.3
All Rough Inspection - Residential Not Ready 3/25/2022 3/25/2022 03/25/2022
Misc
Corrective Action Required
03/09/2022
3/25/22 - INSPECTION DENIED, NOT READY CORRECTIONS NOT ADDRESSED, ADDRESS ALL CORRECTIONS AND SCHEUDLE INSPECTION UNIT 3825 -nail exterior Sheathing for garage PFH per plans/R602.10.6.4 -nail exterior sheathing per plans -fur down at HVAC garage to allow for insulation -remove fur down soffit corner at garage rated wall against studs, will need to pre rock 1/2” rock per plans to maintain UL rating -fireblock between top plate and rock at air gap -fireblock vertical every 10’ between stud and fire rock at air gap throughout -fireblock Plumbing/HVAC at fur out garage wall -seal top plate penetrations -1st floor 1/2 bath -add structural straps at all top plates bored 50% or more on all exterior walls and interior load bearing walls -solid shim all trimmer studs short of header and studs short of top or bottom plate throughout -LIB bracing all locations per plans -(2) 2x4 trimmers at (2)2x10 header garage door per plans -repair damaged sections of fire rock at 2nd floor also cannot scab on smart siding to repair damaged sections of rated fire rock -edges of fire rock are required to be seated in the H channel studs per plans -breakaway clip spacing and attachment per plans -fire rock must extend to roof decking in C channel per plans -clarify UL design for attic fire rated wall -No openings, vents or gaps in fire rated plywood at roof deck within 4’ of fire rated wall -fireblock at top plate between furring strips at rear stair wall 2nd floor -address penetrations through firewall at basement, see detail on page A7.1 of plans -1/2” rock will need to be prerocked when approved at 2nd floor bath at tub against fire rated separation wall, rock cont on wall per UL design -confirm 1/2” rock placement at dbl wall 2nd floor bath at fire rated wall to maintain listed UL requirements and code -fire rated separation required between units at daylight wall basement R302.3 UNIT 3823 -See above corrections list from 3825 and additional corrections listed below -solid block all sheathing breaks at step flashing -provide electrical receptacle at unfinished basement -provide future plumbing vent at basement
Rated Assembly Inspection Failed 3/25/2022 3/25/2022 03/25/2022
Misc
Corrective Action Required
03/09/2022
3/25/22 - INSPECTION DENIED, NOT READY CORRECTIONS NOT ADDRESSED, ADDRESS ALL CORRECTIONS AND SCHEUDLE INSPECTION -remove fur down soffit corner at garage rated wall against studs, will need to pre rock 1/2” rock per plans to maintain UL rating -repair damaged sections of fire rock at 2nd floor also cannot scab on smart siding to repair damaged sections of rated fire rock -edges of fire rock are required to be seated in the H channel studs per plans -breakaway clip spacing and attachment per plans -fire rock must extend to roof decking in C channel per plans -clarify UL design for attic fire rated wall -No openings, vents or gaps in fire rated plywood at roof deck within 4’ of fire rated wall -address penetrations through firewall at basement, see detail on page A7.1 of plans -1/2” rock will need to be prerocked when approved at 2nd floor bath at tub against fire rated separation wall, rock cont on wall per UL design -confirm 1/2” rock placement at dbl wall 2nd floor bath at fire rated wall to maintain listed UL requirements and code -fire rated separation required between units at daylight wall basement R302.3
Electrical Service Inspection Failed 3/25/2022 3/25/2022 03/25/2022
Misc
Corrective Action Required
03/09/2022
PROVIDE UFER GROUND AT SERVICE AS REQUIRED BY CODE E3608.1.2 ADDRESS NUMBERS ON DISCONNECT AND METER CAN
Gas Service Inspection - Residential Not Ready 3/29/2022 3/29/2022 03/29/2022
Misc
Corrective Action Required
03/09/2022
3823 - GAS PRESSURE 0 PSI, MUST MAINTAIN 10 PSI FOR TEST 3825 - PRESSURE OK
Erosion Control Inspection Residential Partial 3/29/2022 3/29/2022 03/29/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
03/29/2022
DEFICIENT EROSION CONTROL INSTALLATION. -MAINTAIN GRAVEL FILTER TO HOUSE, USE MIN. 6" LIFT OF MIN. 3/4" GRAVEL, CLEAN DEBRIS FROM STREET
Misc
Corrective Action Required
03/29/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Electrical Service Inspection Failed 4/6/2022 4/6/2022 04/06/2022
Misc
Corrective Action Required
03/25/2022
PROVIDE UFER GROUND AT SERVICE AS REQUIRED BY CODE E3608.1.2
Gas Service Inspection - Residential Not Ready 4/6/2022 4/6/2022 04/06/2022
Misc
Corrective Action Required
03/29/2022
3823 - GAS PRESSURE 0 PSI, MUST MAINTAIN 10 PSI FOR TEST 3825 - PRESSURE OK
All Rough Inspection - Residential Not Ready 4/7/2022 4/7/2022 04/07/2022
Misc
Corrective Action Required
03/25/2022
4/7/22 - NOT READY FOR INSPECTION, CORRECT DEFICIENCIES BEFORE RESCHEDULING UNIT 3825 -nail exterior Sheathing for garage PFH per plans/R602.10.6.4 -nail exterior sheathing per plans -fireblock between top plate and rock at air gap -fireblock vertical every 10’ between stud and fire rock at air gap throughout -fireblock Plumbing/HVAC at fur out garage wall -LIB bracing all locations per plans -(2) 2x4 trimmers at (2)2x10 header garage door per plans -repair damaged sections of fire rock at 2nd floor also cannot scab on smart siding to repair damaged sections of rated fire rock -edges of fire rock are required to be seated in the H channel studs per plans -breakaway clip spacing and attachment per plans -fire rock must extend to roof decking in C channel per plans -address penetrations through firewall at basement, see detail on page A7.1 of plans -fire rated separation required between units at daylight wall basement R302.3 UNIT 3823 nail exterior Sheathing for garage PFH per plans/R602.10.6.4 -nail exterior sheathing per plans -fur down at HVAC garage to allow for insulation -fireblock between top plate and rock at air gap -fireblock vertical every 10’ between stud and fire rock at air gap throughout -fireblock Plumbing/HVAC at fur out garage wall -seal top plate penetrations -1st floor 1/2 bath -add structural straps at all top plates bored 50% or more on all exterior walls and interior load bearing walls -solid shim all trimmer studs short of header and studs short of top or bottom plate throughout -LIB bracing all locations per plans -(2) 2x4 trimmers at (2)2x10 header garage door per plans -repair damaged sections of fire rock at 2nd floor also cannot scab on smart siding to repair damaged sections of rated fire rock -edges of fire rock are required to be seated in the H channel studs per plans -breakaway clip spacing and attachment per plans -fire rock must extend to roof decking in C channel per plans -fireblock at top plate between furring strips at rear stair wall 2nd floor -address penetrations through firewall at basement, see detail on page A7.1 of plans -fire rated separation required between units at daylight wall basement R302.3 -solid block all sheathing breaks at step flashing -provide electrical receptacle at unfinished basement -provide future plumbing vent at basement
Rated Assembly Inspection Failed 4/7/2022 4/7/2022 04/07/2022
Misc
Corrective Action Required
03/25/2022
UNIT 3825 -fireblock between top plate and rock at air gap -fireblock vertical every 10’ between stud and fire rock at air gap throughout -repair damaged sections of fire rock at 2nd floor also cannot scab on smart siding to repair damaged sections of rated fire rock -edges of fire rock are required to be seated in the H channel studs per plans -breakaway clip spacing and attachment per plans -fire rock must extend to roof decking in C channel per plans -address penetrations through firewall at basement, see detail on page A7.1 of plans -fire rated separation required between units at daylight wall basement R302.3 UNIT 3823 -fireblock between top plate and rock at air gap -fireblock vertical every 10’ between stud and fire rock at air gap throughout -repair damaged sections of fire rock at 2nd floor also cannot scab on smart siding to repair damaged sections of rated fire rock -edges of fire rock are required to be seated in the H channel studs per plans -breakaway clip spacing and attachment per plans -fire rock must extend to roof decking in C channel per plans -fireblock at top plate between furring strips at rear stair wall 2nd floor -address penetrations through firewall at basement, see detail on page A7.1 of plans -fire rated separation required between units at daylight wall basement R302.3
Gas Service Inspection - Residential Passed 4/27/2022 4/27/2022 04/27/2022
Misc
Resolved
04/27/2022
Rated Assembly Inspection Failed 4/27/2022 4/27/2022 04/27/2022
Misc
Corrective Action Required
04/07/2022
UNIT 3825 ok UNIT 3823 -repair damaged sections of fire rock at 2nd floor- see master bed, laundry, bath -fire rock must extend to roof decking in C channel per plans
All Rough Inspection - Residential Failed 4/27/2022 4/27/2022 04/27/2022
Misc
Corrective Action Required
04/07/2022
UNIT 3825 ok UNIT 3823 -repair damaged sections of fire rock at 2nd floor- see master bed, laundry, bath -fire rock must extend to roof decking in C channel per plans
Electrical Service Inspection Failed 4/27/2022 4/27/2022 04/27/2022
Misc
Corrective Action Required
04/06/2022
- E3608.1.2 CONCRETE ENCASED ELECTRODE NOT LESS THAN 20' ENCASED BY AT LEAST 2" OF CONCRETE SHALL BE LOCATED HORIZONTALLY WITHIN THAT PORTION OF CONCRETE FOUNDATION OR FOOTING THAT IS WITHIN DIRECT CONTACT WITH THE EARTH OR WITHIN VERTICAL FOUNDATIONS OR STRUCTURAL COMPONENTS OR MEMBERS THAT ARE IN DIRECT CONACT WITH THE EARTH -GEC FROM UFER MUST LAND ON FIRST DISCONNECT NEUTRAL BAR NOT SUB PANELS ON INTERIOR
Rated Assembly Inspection Passed 4/28/2022 4/28/2022 04/28/2022
Misc
Resolved
04/28/2022
All Rough Inspection - Residential Passed 4/28/2022 4/28/2022 04/28/2022
Misc
Resolved
04/28/2022
Driveway Inspection Partial 5/11/2022 5/11/2022 05/11/2022
Misc
Informational
05/11/2022
On 5.11.2022 I performed a driveway inspection and pass the sub-grade to pour concrete
Sidewalk Inspection Partial 5/11/2022 5/11/2022 05/11/2022
Misc
Informational
05/11/2022
On 5.11.2022 I performed a sidewalk inspection and pass the sub-grade to pour concrete
Electrical Service Inspection Failed 5/26/2022 5/26/2022 05/26/2022
Misc
Corrective Action Required
04/27/2022
5/2622 - INSPECTION DENIED, POST ADDRESS BEFORE ANY FURTHER INSPECTIONS - E3608.1.2 CONCRETE ENCASED ELECTRODE NOT LESS THAN 20' ENCASED BY AT LEAST 2" OF CONCRETE SHALL BE LOCATED HORIZONTALLY WITHIN THAT PORTION OF CONCRETE FOUNDATION OR FOOTING THAT IS WITHIN DIRECT CONTACT WITH THE EARTH OR WITHIN VERTICAL FOUNDATIONS OR STRUCTURAL COMPONENTS OR MEMBERS THAT ARE IN DIRECT CONACT WITH THE EARTH -GEC FROM UFER MUST LAND ON FIRST DISCONNECT NEUTRAL BAR NOT SUB PANELS ON INTERIOR
Electrical Service Inspection Passed 6/2/2022 6/2/2022 06/02/2022
Misc
Resolved
06/02/2022
Piers/Caissons Inspection - Residential Failed 6/7/2022 (9:00) 6/7/2022 06/07/2022
Misc
Corrective Action Required
06/07/2022
(2) 16" x 36" PIERS PER PLANS
Piers/Caissons Inspection - Residential Passed 6/9/2022 (10:45) 6/9/2022 06/09/2022
Misc
Resolved
06/09/2022
(2) 16" x 36" PIERS PER PLANS
Driveway Inspection Passed 6/23/2022 6/23/2022 06/23/2022
Misc
Informational
05/11/2022
On 5.11.2022 I performed a driveway inspection and pass the sub-grade to pour concrete On 6.23.2022 the driveway appears to be compliant.
Sidewalk Inspection Passed 6/23/2022 6/23/2022 06/23/2022
Misc
Informational
05/11/2022
On 5.11.2022 I performed a sidewalk inspection and pass the sub-grade to pour concrete On 6.23.2022 the sidewalk appears to be compliant
Occupancy Inspection - Codes Residential Failed 6/24/2022 6/24/2022 06/24/2022
Misc
Corrective Action Required
06/24/2022
NOT READY FOR INSPECTION
Occupancy Inspection - Codes Residential Failed 6/27/2022 6/27/2022 06/27/2022
Misc
Resolved
06/27/2022
NOT READY FOR INSPECTION
Misc
Corrective Action Required
06/27/2022
Maintain erosion control until sod is in place. 3823 Final grade (provide as graded plot plan) -sod -splash blocks and sump pump discharge to extend 36” from foundation -check water meter at time of final grade and sod -secure ac whip within 12” of disconnect -seal all exterior penetrations -garage entry door must be self closing and latching -outlets in garage must comply with code section E3901.9 of the irc 3825 Final grade (provide as graded plot plan) -sod -splash blocks and sump pump discharge to extend 36” from foundation -check water meter at time of final grade and sod -garage entry door must be self closing and latching -outlets in garage must comply with code section E3901.9 of the irc
Occupancy Inspection - Codes Residential Temporary C of O 6/28/2022 6/28/2022 06/28/2022
Misc
Corrective Action Required
06/27/2022
Maintain erosion control until sod is in place. 3823 Final grade (provide as graded plot plan) -sod -splash blocks and sump pump discharge to extend 36” from foundation -check water meter at time of final grade and sod 3825 Final grade (provide as graded plot plan) -sod -splash blocks and sump pump discharge to extend 36” from foundation -check water meter at time of final grade and sod **3823 AND 3825 OK FOR TCO, TCO EXPIRES 7/28/22
Water Service Inspection - R Passed 7/1/2022 07/01/2022
Water Service Inspection - R Passed 7/6/2022 (11:00) 7/6/2022 07/06/2022
Occupancy Inspection - Codes Residential Failed 7/21/2022 7/21/2022 07/21/2022
Misc
Corrective Action Required
06/28/2022
-permanent addresses meter can and disconnects -submit as graded plot plan for review and approval -splash blocks and sump pump discharge to extend 36” from foundation -provide gravel base water meter pit -handrail required at deck stairs -provide landing at deck stair flight **3823 AND 3825 OK FOR TCO, TCO EXPIRES 7/28/22
Plot Plan Inspection Passed 8/1/2022 8/1/2022 08/01/2022
Occupancy Inspection - Codes Residential Ready for Temp CO 8/2/2022 08/02/2022
Misc
Corrective Action Required
07/21/2022
-permanent addresses meter can and disconnects -submit as graded plot plan for review and approval -splash blocks and sump pump discharge to extend 36” from foundation -provide gravel base water meter pit -handrail required at deck stairs -provide landing at deck stair flight **3823 AND 3825 OK FOR TCO, TCO EXTENSION REQUEST REC AND APPROVED 8/2/22**
Occupancy Inspection - Codes Residential Temporary C of O 08/03/2022
Misc
Corrective Action Required
08/02/2022
-permanent addresses meter can and disconnects -submit as graded plot plan for review and approval -splash blocks and sump pump discharge to extend 36” from foundation -provide gravel base water meter pit -handrail required at deck stairs -provide landing at deck stair flight **3823 AND 3825 OK FOR TCO, TCO EXTENSION REQUEST REC AND APPROVED 8/2/22**
Erosion Control Inspection Residential Passed 8/9/2022 8/9/2022 08/09/2022
Misc
Resolved
08/09/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Occupancy Inspection - Codes Residential Full C of O 8/9/2022 8/9/2022 08/09/2022
Misc
Resolved
08/09/2022
Documents & Images
Date Uploaded File Type Document Name
07/12/2021 Application Form OS #22 - PERMIT APP
07/13/2021 Permit Codes Residential Plan Review
07/13/2021 Approved Plans Approved Truss Layout
07/13/2021 Approved Plans Approved Truss Package
07/13/2021 Permit Codes Residential Plan Review
07/13/2021 Permit DS Building Permit
07/13/2021 Receipt Receipt for transaction:2021-005594
08/23/2021 3823 & 3825 SW Walsh Dr LSMO Osage Lot 22 Clayton Properties P 2021-3583 3rd Party Footing Inspection Report 8-18-21
08/24/2021 Letter INSPECTION SUMMARY
09/17/2021 Letter INSPECTION SUMMARY
09/21/2021 Letter INSPECTION SUMMARY
10/19/2021 Letter INSPECTION SUMMARY
10/19/2021 Letter INSPECTION SUMMARY
10/20/2021 22 Osage-Undermined FTNG
10/22/2021 Receipt Receipt for transaction: 2021-008192
10/25/2021 Letter INSPECTION SUMMARY
11/01/2021 Letter INSPECTION SUMMARY
11/02/2021 22 Osage-AB3 Confirmation
11/03/2021 Letter INSPECTION SUMMARY
11/03/2021 Letter INSPECTION SUMMARY
01/31/2022 Approved Plans Approved Drawings
03/02/2022 Letter INSPECTION SUMMARY
03/02/2022 Letter INSPECTION SUMMARY
03/09/2022 Letter INSPECTION SUMMARY
03/09/2022 Letter INSPECTION SUMMARY
03/09/2022 Letter INSPECTION SUMMARY
03/09/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
04/06/2022 Letter INSPECTION SUMMARY
04/06/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/27/2022 Letter INSPECTION SUMMARY
04/27/2022 Letter INSPECTION SUMMARY
04/27/2022 Letter INSPECTION SUMMARY
04/27/2022 Letter INSPECTION SUMMARY
04/27/2022 Letter INSPECTION SUMMARY
04/28/2022 Letter INSPECTION SUMMARY
04/28/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/26/2022 Letter INSPECTION SUMMARY
06/02/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
06/09/2022 Letter INSPECTION SUMMARY
06/21/2022 LOT 22 FINAL 6-21-22
06/21/2022 Approved Plans Approved Drawings
06/24/2022 Letter INSPECTION SUMMARY
06/27/2022 Letter INSPECTION SUMMARY
06/27/2022 Letter INSPECTION SUMMARY
06/27/2022 Letter INSPECTION SUMMARY
06/28/2022 Receipt Receipt for transaction:2022-005208
06/28/2022 Letter Codes Temporary Certificate of Occupancy
06/29/2022 LOT 22 MINOR PLAT SEAL
06/30/2022 Plot Plan Approved Plot Plan
07/01/2022 Letter INSPECTION SUMMARY
07/06/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/28/2022 Plot Plan Approved As Graded Plot Plan
08/01/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter OS 22 A and B Extension Request Form
08/03/2022 Receipt Receipt for transaction:2022-006329
08/03/2022 Letter Codes Temporary Certificate of Occupancy
08/09/2022 Letter INSPECTION SUMMARY
08/09/2022 Letter Field Certificate of Occupancy
08/09/2022 Letter Codes Final Certificate of Occupancy
01/29/2024 LOT 22 ASBUILT
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home