Summary
PRRES20213052
Building Permit - Residential
Certificate of Occupancy
NEW DUPLEX
NEW DUPLEX - ROOF TRUSSES - UNFINISHED BASEMENT - UNCOVERED DECK
06/15/2021
06/15/2021
08/12/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Duplex $1,390.59 $1,390.59 Paid 06/15/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/15/2021
7232302-Residential Excise Tax Fee $2,154.24 $2,154.24 Paid 06/15/2021
8331507-Sewer Connection Fee $720.00 $720.00 Paid 06/15/2021
8331401-Water Tap Fee $7,162.00 $7,162.00 Paid 06/15/2021
8350015-Water Meter Fee $911.08 $911.08 Paid 06/15/2021
8331504-EFHB Middle Big Creek, Full $803.52 $803.52 Paid 10/22/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/28/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $100.00 $100.00 Paid 06/28/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 08/03/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/19/2021 8/19/2021 08/19/2021
Misc
Informational
08/19/2021
APPROVED PER DAVID P AINSWORTH 8/16/21
Underslab Plumbing Inspection - Residential Passed 9/17/2021 9/17/2021 09/17/2021
Misc
Informational
09/17/2021
3817, 3819 OK
Sewer Service Inspection - R Partial 10/14/2021 (11:00) 10/14/2021 10/14/2021
Misc
Informational
10/14/2021
3819 OK
Sewer Service Inspection - R Passed 10/19/2021 (8:00) 10/19/2021 10/19/2021
Sewer Service Inspection - R Failed 10/19/2021 10/19/2021
Misc
Corrective Action Required
10/19/2021
both sides of footing where the sewer was excavated is undermined provide engineers report on undermined footing.
Water Service Inspection - R Passed 10/25/2021 (10:00) 10/25/2021 10/25/2021
Misc
Informational
10/25/2021
3817 AND 3819 OK
Sewer Service Inspection - R Passed 11/3/2021 11/3/2021 11/03/2021
Misc
Resolved
11/03/2021
both sides of footing where the sewer was excavated is undermined provide engineers report on undermined footing.
Gas Service Inspection - Residential Passed 3/2/2022 3/2/2022 03/02/2022
Erosion Control Inspection Residential Failed 3/2/2022 3/2/2022 03/02/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/02/2022
DEFICIENT EROSION CONTROL INSTALLATION. -MAINTAIN SILT FENCE AT PERIMETER, MAINTAIN GRAVEL FILTER WITH MIN 6" LIFT OF 3/4" GRAVEL TO HOUSE, CLEAN DEBRIS FROM STREETS.
Electrical Service Inspection Failed 3/2/2022 3/2/2022 03/02/2022
Misc
Corrective Action Required
03/02/2022
-PROVIDE PERMANENT ADDRESS AT METER CAN AND DISCONNECT -PROVIDE UFER GROUND AT SERVICE
All Rough Inspection - Residential Failed 3/9/2022 3/9/2022 03/09/2022
Misc
Corrective Action Required
03/09/2022
UNIT 3817 -nail exterior sheathing at garage PFH per code R602.10.6.4 -nail all exterior sheathing per plans -clarify UL design for attic fire rated wall -top plate to top plate connection as required by code at east garage corner -fireblock between studs of soffit line 2x6 wall garage -anchor bolts to be in middle third of plate at garage -repair damaged fire rock at rated separation wall -fireblock vertical every 10’ between stud and fire rock at rated separation wall -No ridge vent or openings of 4’ fire rated play wood roof deck -screw all breakaway clips at firewall per detail, breakaway clip attachment and location per plans -(4) 2x studs packs at all girder truss bearing ends per plans -security blocking at deck door -fireblock tub trap 1st floor bath -Fireblock deadspace bed#2 closet -fireblock between studs at bed#2 closet wall, stair wall side -structural straps at all top plates bored 50% or more all interior load bearing walls and all exterior walls -(2) 2x12 header continuous corner to corner for CS-PF design at great room windows and master bed windows per plans, basement windows -nail exterior sheathing CS-PF all locations per plans -LIB bracing per plans at bed#2 wall -all truss lateral bracing per plans -add future vent for basement plumbing -cap future vent -add hot water heater circuit -secure SE cable above service panel -solid shim all trimmer studs cut short of headers throughout -solid shim all studs short of plate throughout -address all penetrations through fire rated wall at basement per plans, detail on page A7.1 UNIT 3819 SEE CORRECTIONS LIST ABOVE FOR 3817 AND ADDITIONAL CORRECTIONS LISTED BELOW -nail lib x bracing strap to top plate at great room -remove ties bundling NM at basement
Electrical Service Inspection Failed 3/9/2022 3/9/2022 03/09/2022
Misc
Corrective Action Required
03/09/2022
PROVIDE UFER GROUND AT SERVICE AS REQUIRED BY CODE E608.1.2
Rated Assembly Inspection Failed 3/9/2022 3/9/2022 03/09/2022
Misc
Corrective Action Required
03/09/2022
-clarify UL design for attic fire rated wall -repair damaged fire rock at rated separation wall -No ridge vent or openings of 4’ fire rated play wood roof deck -screw all breakaway clips at firewall per detail, breakaway clip attachment and location per plans
Electrical Service Inspection Failed 3/25/2022 3/25/2022 03/25/2022
Misc
Corrective Action Required
03/09/2022
PROVIDE UFER GROUND AT SERVICE AS REQUIRED BY CODE E608.1.2 PROVIDE ADDRESS NUMBERS ON DISCONNECT AND METER CAN
Rated Assembly Inspection Failed 3/25/2022 3/25/2022 03/25/2022
Misc
Corrective Action Required
03/25/2022
-firecaulk electric feeder cable penetration at rated wall rim joist basement -fire rated separation required between units at daylight wall basement R302.3 -repair any damaged sections of fire rock -firerock should be seated in c channel runner at roof deck, no gaps
All Rough Inspection - Residential Failed 3/25/2022 3/25/2022 03/25/2022
Misc
Corrective Action Required
03/25/2022
UNIT 3817: -nail exterior sheathing per plans -nail exterior sheathing at garage PFH per code -anchor bolts required to be within the middle third of bottom plate see garage -dbl top plate requires min 24” offset between plate breaks - see garage -address top plate connection to tie wall together per code right of great room window corner -trimmer studs overnotched at great room window CS-PF -CS-PF bracing design at great room and master bed per plans -security blocking required at deck door -(4) 2X stud packs required at all girder truss bearing ends per plans -secure electrical box to wall at master bedroom -Fireblock all tub traps -solid shim all trimmer studs short of header throughout -structural straps at all top plates bored 50% or more all interior load bearing walls and all exterior walls -install all nuts on anchor bolts at basement -sister 2x6 to studs at basement daylight walls that are overnotched around anchor bolts -basement window CS-PF bracing per plans, (2) 2x12 header continuous corner to corner -firecaulk electric feeder cable penetration at rated wall rim joist basement -fire rated separation required between units at daylight wall basement R302.3 -all truss lateral bracing per plans UNIT 3819: -nail exterior sheathing per plans -nail exterior sheathing PFH at garage per code -repair any damaged sections of fire rock -firerock should be seated in c channel runner at roof deck, no gaps -address top plate connection to tie wall together per code left of great room window corner -(4) 2X stud packs required at all girder truss bearing ends per plans, replace studs that have been overnotched around electrical -secure electrical box to wall at master bedroom -security blocking at deck door -CS-PF bracing design at great room and master bed per plans -structural straps at all top plates bored 50% or more all interior load bearing walls and all exterior walls -solid shim all trimmer studs cut short of header throughout -trimmer studs overnotched at great room window CS-PF -all truss lateral bracing per plans -firecaulk electric feeder cable penetration at rated wall rim joist basement -fire rated separation required between units at daylight wall basement R302.3 -sister 2x6 to studs at basement daylight walls that are overnotched around anchor bolts -(3) studs at wall corner, nailed off, anchor bolt plate -anchor bolts within 12” of plate break at basement -CS-PF bracing per plans at basement window, (2) 2x12 header continuous corner to corner
Electrical Service Inspection Not Ready 4/6/2022 4/6/2022 04/06/2022
Misc
Corrective Action Required
03/25/2022
PROVIDE UFER GROUND AT SERVICE AS REQUIRED BY CODE E608.1.2
All Rough Inspection - Residential Failed 4/7/2022 4/7/2022 04/07/2022
Misc
Corrective Action Required
03/25/2022
UNIT 3817: -nail exterior sheathing per plans -nail exterior sheathing at garage PFH per code -have engineer address north side garage wall with expansion bolts anchor bolts due to bolts not being in middle third of plate and bottom plate over foundation wall -address top plate connection to tie wall together per code right of great room window corner -CS-PF bracing design at great room and master bed per plans, nail exterior sheathing per plans -structural straps at all top plates bored 50% or more all interior load bearing walls and all exterior walls -basement window CS-PF bracing per plans, (2) 2x12 header continuous corner to corner UNIT 3819: -nail exterior sheathing per plans -address top plate connection to tie wall together per code left of great room window corner -CS-PF bracing design at great room and master bed per plans, nail exterior sheathing per plans -structural straps at all top plates bored 50% or more all interior load bearing walls and all exterior walls -CS-PF bracing per plans at basement window, (2) 2x12 header continuous corner to corner
Rated Assembly Inspection Passed 4/7/2022 4/7/2022 04/07/2022
Misc
Resolved
04/07/2022
All Rough Inspection - Residential Passed 4/12/2022 4/12/2022 04/12/2022
Misc
Resolved
04/12/2022
Electrical Service Inspection Failed 4/26/2022 4/26/2022 04/26/2022
Misc
Corrective Action Required
04/06/2022
- E3608.1.2 CONCRETE ENCASED ELECTRODE NOT LESS THAN 20' ENCASED BY AT LEAST 2" OF CONCRETE SHALL BE LOCATED HORIZONTALLY WITHIN THAT PORTION OF CONCRETE FOUNDATION OR FOOTING THAT IS WITHIN DIRECT CONTACT WITH THE EARTH OR WITHIN VERTICAL FOUNDATIONS OR STRUCTURAL COMPONENTS OR MEMBERS THAT ARE IN DIRECT CONACT WITH THE EARTH -GEC FROM UFER MUST LAND ON FIRST DISCONNECT NEUTRAL BAR NOT SUB PANELS ON INTERIOR
Driveway Inspection Partial 5/9/2022 5/9/2022 05/09/2022
Misc
Informational
05/09/2022
This is a fourplex unit. On 5.9.2022 I performed a driveway inspection for units 3817 and 3819 SW Walsh Drive and pass the subgrade to pour concrete.
Sidewalk Inspection Partial 5/9/2022 5/9/2022 05/09/2022
Misc
Informational
05/09/2022
This is a fourplex unit. On 5.9.2022 I performed a sidewalk inspection for units 3817 and 3819 SW Walsh Drive and pass the subgrade to pour concrete.
Electrical Service Inspection Passed 6/20/2022 6/20/2022 06/20/2022
Misc
Resolved
06/20/2022
Driveway Inspection Passed 6/23/2022 6/23/2022 06/23/2022
Misc
Informational
06/23/2022
6.23.2022 Driveway appears to be compliant
Sidewalk Inspection Passed 6/23/2022 6/23/2022 06/23/2022
Misc
Informational
05/09/2022
This is a fourplex unit. On 5.9.2022 I performed a sidewalk inspection for units 3817 and 3819 SW Walsh Drive and pass the subgrade to pour concrete. This is a fourplex. On 6.23.2022 Sidewalk appears to be compliant.
Occupancy Inspection - Codes Residential Failed 6/24/2022 6/24/2022 06/24/2022
Misc
Corrective Action Required
06/24/2022
-Resolve all outstanding inspection fees -Final grade and sod -Splash blocks -Provide perm address labels at meter can and disconnects 3817 -hot/neutral reversed at master bath outlet -mark all breaker locations at panel -AFCI protection all breaker locations per code -blank off unused breaker locations at panel -remove mold from rock at basement stair wall 3819 -provide hammer arrestor at dishwasher -mark all breaker locations at panel -AFCI protection all breaker locations per code -blank off unused breaker locations at panel -provide breaker lockout hot water heater
Water Service Inspection - R Passed 6/27/2022 (8:45) 6/27/2022 06/27/2022
Occupancy Inspection - Codes Residential Failed 6/27/2022 6/27/2022 06/27/2022
Miscellaneous Correction
Corrective Action Required
06/27/2022
-Final grade, splash blocks, sump extension -Raise meter pit to grade, ensure 14"-18" to top of meter 3817-NO ACCESS 3819- -Wall receptacles not to eceed 5.5' from finished floor per E3901.9 in garage -Garage door to be self closing and latching -Provide hammer arrestor at dishwasher -Stairs vary greater than 3/8" at top riser to main floor -Secure handrail at basement landing -Provide (2) 1/2" through bolts at all post to beam connections at deck -Flood light at exterior to be non accessible light source or above 8' -Obtain lawn irrigation permit and backflow certification -Seal top of meter can and disconnects
Occupancy Inspection - Codes Residential Temporary C of O 6/29/2022 6/29/2022 06/29/2022
Miscellaneous Correction
Corrective Action Required
06/27/2022
-Final grade and sod, splash blocks, sump extension -obtain lawn irrigation system permit 3817 and 3819 ok for TCO, TCO EXPIRES 7/29/22
Occupancy Inspection - Codes Residential Failed 7/20/2022 7/20/2022 07/20/2022
Miscellaneous Correction
Corrective Action Required
06/29/2022
3817&3819 -obtain lawn irrigation system permit -permanent addresses meter can and disconnects -set sewer tracer box to grade 3817 and 3819 ok for TCO, TCO EXPIRES 7/29/22 3817 -Sump pump extension -Handrail required at deck stairs -Provide landing at deck stairs flight (13 1/4” drop to grade) 3819 -Sump pump extension
Occupancy Inspection - Codes Residential Ready for Temp CO 8/2/2022 08/02/2022
Miscellaneous Correction
Corrective Action Required
07/20/2022
3817&3819 -obtain lawn irrigation system permit -permanent addresses meter can and disconnects -set sewer tracer box to grade **3817 and 3819 ok for TCO, TCO EXTENSION REQUEST REC AND APPROVED 8/2/22** 3817 -Sump pump extension -Handrail required at deck stairs -Provide landing at deck stairs flight (13 1/4” drop to grade) 3819 -Sump pump extension
Occupancy Inspection - Codes Residential Temporary C of O 08/03/2022
Miscellaneous Correction
Corrective Action Required
08/02/2022
3817&3819 -obtain lawn irrigation system permit -permanent addresses meter can and disconnects -set sewer tracer box to grade **3817 and 3819 ok for TCO, TCO EXTENSION REQUEST REC AND APPROVED 8/2/22** 3817 -Sump pump extension -Handrail required at deck stairs -Provide landing at deck stairs flight (13 1/4” drop to grade) 3819 -Sump pump extension
Erosion Control Inspection Residential Passed 08/12/2022
Plot Plan Inspection Passed 08/12/2022
Occupancy Inspection - Codes Residential Full C of O 8/12/2022 8/12/2022 08/12/2022
Miscellaneous Correction
Resolved
08/12/2022
3817&3819 **3817 and 3819 ok for TCO, TCO EXTENSION REQUEST REC AND APPROVED 8/2/22** 3817 -Sump pump extension -Handrail required at deck stairs -Provide landing at deck stairs flight (13 1/4” drop to grade) 3819 -Sump pump extension
Documents & Images
Date Uploaded File Type Document Name
06/15/2021 OS #23 - PERMIT APP
06/15/2021 Approved Plans APPROVED TRUSS DRAWINGS
06/15/2021 Approved Plans APPROVED TRUSS LAYOUT
06/15/2021 Permit Codes Residential Plan Review
06/15/2021 Receipt Receipt for transaction:2021-004442
08/17/2021 M L Crose 3817 & 3819 SW Walsh Dr LSMO Twin Honedew Lot 23 P 2021-3052 3rd Party Footing Inspection Report 8-16-21
08/19/2021 Letter INSPECTION SUMMARY
08/24/2021 Permit DS Building Permit
09/17/2021 Letter INSPECTION SUMMARY
10/14/2021 Letter INSPECTION SUMMARY
10/19/2021 Letter INSPECTION SUMMARY
10/19/2021 Letter INSPECTION SUMMARY
10/20/2021 23 Osage-Undermined FTNG
10/22/2021 Receipt Receipt for transaction: 2021-008192
10/25/2021 Letter INSPECTION SUMMARY
11/02/2021 23 Osage-AB3 Confirmation
11/03/2021 Letter INSPECTION SUMMARY
03/02/2022 Letter INSPECTION SUMMARY
03/02/2022 Letter INSPECTION SUMMARY
03/02/2022 Letter INSPECTION SUMMARY
03/09/2022 Letter INSPECTION SUMMARY
03/09/2022 Letter INSPECTION SUMMARY
03/09/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
04/06/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/08/2022 23 osage letter
04/12/2022 Letter INSPECTION SUMMARY
04/26/2022 Letter INSPECTION SUMMARY
05/09/2022 Letter INSPECTION SUMMARY
05/09/2022 Letter INSPECTION SUMMARY
06/20/2022 Letter INSPECTION SUMMARY
06/21/2022 Approved Plans APPROVED PLANS
06/21/2022 Approved Plans APPROVED PLOT PLAN
06/23/2022 Letter INSPECTION SUMMARY
06/24/2022 Letter INSPECTION SUMMARY
06/24/2022 Letter INSPECTION SUMMARY
06/27/2022 Letter INSPECTION SUMMARY
06/27/2022 Letter INSPECTION SUMMARY
06/28/2022 Receipt Receipt for transaction:2022-005207
06/29/2022 Letter Codes Temporary Certificate of Occupancy
06/29/2022 LOT 23 MINOR PLAT SEAL
06/30/2022 Plot Plan approved plot plan
07/19/2022 23 Osage Letter #2
07/20/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter OS 23 A and B Extension Request Form
08/03/2022 Receipt Receipt for transaction:2022-006328
08/03/2022 Letter Codes Temporary Certificate of Occupancy
08/12/2022 Letter INSPECTION SUMMARY
08/12/2022 Letter INSPECTION SUMMARY
08/12/2022 Letter Codes Final Certificate of Occupancy
08/12/2022 Letter Field Certificate of Occupancy
12/20/2022 TCO request form for OS model home (OS25A)
12/20/2022 TCO request form for OS28
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home