Permit Application Status

PRRES20212885


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20212885
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
06/03/2021
06/14/2021
12/11/2021
06/13/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $360.00 $360.00 Paid 06/14/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/14/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/14/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 06/14/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 06/14/2021
9110078-Valuation Fee New Single Family $885.79 $885.79 Paid 06/14/2021
8331504-EFHB Middle Big Creek, Full $401.76 $401.76 Paid 10/22/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 04/25/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/2/2021 9/2/2021 09/02/2021
Misc
Informational
09/02/2021
APPROVED PER DAVID P AINSWORTH 8/25/21
Underslab Plumbing Inspection - Residential Passed 10/15/2021 10/15/2021 10/15/2021
Sewer Service Inspection - R Passed 12/20/2021 12/20/2021 12/20/2021
Water Service Inspection - R Passed 1/5/2022 (10:45) 1/5/2022 01/05/2022
Gas Service Inspection - Residential Passed 1/19/2022 1/19/2022 01/19/2022
Electrical Service Inspection Failed 1/19/2022 1/19/2022 01/19/2022
Misc
Corrective Action Required
01/19/2022
-Install clamp listed for rebar to GEC at UFER, separation of dissimilar metals
All Rough Inspection - Residential Failed 1/19/2022 1/19/2022 01/19/2022
Misc
Corrective Action Required
01/19/2022
-30” vertical clearance required at attic access garage -protect NM within 6’ of attic access -seal all top and bottom plate penetrations throughout -secure vertical DWV 2” or less at mid point -ensure proper slope of DWV span across trusses in attic -security blocking at rear door and front door -install window great room -protection plate at SE cable front bedroom -(4) stud pack at girder truss bearing ends per plans, studs in place have been overnotched -CS-PF bracing at great room windows per plans, tension straps and nail exterior sheathing per design, (2) 2x12 header per plans -address overbored floor joist for DWV basement, pex bored less than 2” from end of joist -address joists bored less than 2” from end of joist for NM near service panel basement -add circuit for electric water heather -nail all exterior sheathing per plans, nails missed studs several locations throughout -Install clamp listed for rebar to GEC at UFER, separation of dissimilar metals
Electrical Service Inspection Passed 1/28/2022 1/28/2022 01/28/2022
Misc
Resolved
01/28/2022
-Install clamp listed for rebar to GEC at UFER, separation of dissimilar metals
All Rough Inspection - Residential Passed 1/28/2022 1/28/2022 01/28/2022
Misc
Resolved
01/28/2022
Driveway Inspection Partial 3/1/2022 03/01/2022
Misc
Informational
03/01/2022
On 3.1.2022 Tuesday I performed a driveway inspection and pass the subgrade to pour concrete at the time of this inspection
Sidewalk Inspection Partial 4/7/2022 4/7/2022 04/07/2022
Misc
Informational
04/07/2022
On Thursday 4.7.2022 I performed a driveway inspection and pass the subgrade to pour concrete
Driveway Inspection Passed 04/22/2022
Misc
Informational
03/01/2022
On 3.1.2022 Tuesday I performed a driveway inspection and pass the subgrade to pour concrete at the time of this inspection
Sidewalk Inspection Passed 4/22/2022 4/22/2022 04/22/2022
Misc
Informational
04/07/2022
On Thursday 4.7.2022 I performed a driveway inspection and pass the subgrade to pour concrete
Erosion Control Inspection Residential Failed 04/22/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/22/2022
4/22/22 EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -PROVIDE EROSION CONTROL AT PERIMETER AND MAINTAIN UNTIL SOD IS IN PLACE. CLEAN DEBRIS FROM STREETS
Occupancy Inspection - Codes Residential Not Ready 4/22/2022 4/22/2022 04/22/2022
Misc
Corrective Action Required
04/22/2022
-House not ready -Pay all fees before occupancy -Provide/ maintain erosion control at perimeter and clean debris from streets before any further inspections. Straw wattles need to be undamaged, extend to protect the entire area, and installed correctly if being used as BMP -Sidewalk and driveway inspections still pending -Obtain lawn irrigation permit and backflow certification -Provide GFCI protection at garage receptacles, exterior receptacles, laundry receptacle, unfinished basement receptacle -Provide non combustible attic access cover -Label dedicated non GFCI receptacles -Provide graspable handrail in garage -Complete stairs and gaurdrail at patio -Provide security screws in back door -Provide AFCI protection per NEC210.12 -Repair split floor joist above sump pump -Complete electrical at water heater -Seal all penetrations at exterior
Occupancy Inspection - Codes Residential Failed 4/26/2022 4/26/2022 04/26/2022
Misc
Corrective Action Required
04/22/2022
-Obtain lawn irrigation permit and backflow certification -Provide GFCI protection at patio receptacle and basement sump pump receptacle -final grade and sod -splash blocks all downspout and sump pump locations, min 36” discharge from foundation -complete guardrail back patio
Occupancy Inspection - Codes Residential Temporary C of O 4/27/2022 4/27/2022 04/27/2022
Misc
Corrective Action Required
04/26/2022
-Obtain lawn irrigation permit and backflow certification -final grade and sod -splash blocks all downspout and sump pump locations, min 36” discharge from foundation -complete guardrail back patio **OK FOR TCO - TCO EXPIRES 5/25/22**
Erosion Control Inspection Residential Failed 4/27/2022 4/27/2022 04/27/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/27/2022
Misc
Corrective Action Required
04/27/2022
RE ESTABLISH AND MAINTAIN EROSION CONTROL ON LOT UNTIL SOD IS PLACED
Occupancy Inspection - Codes Residential Temporary C of O 5/26/2022 05/26/2022
Misc
Corrective Action Required
04/27/2022
-Obtain lawn irrigation permit and backflow certification -final grade and sod -splash blocks all downspout and sump pump locations, min 36” discharge from foundation -complete guardrail back patio -Correct water meter issues
Water Service Inspection - R Passed 6/9/2022 (10:45) 6/9/2022 06/09/2022
Erosion Control Inspection Residential Passed 06/13/2022
Misc
Resolved
06/13/2022
Plot Plan Inspection Passed 06/13/2022
Piers/Caissons Inspection - Residential Passed 06/13/2022
Occupancy Inspection - Codes Residential Full C of O 6/13/2022 6/13/2022 06/13/2022
Misc
Resolved
06/13/2022
Documents & Images
Date Uploaded File Type Document Name
06/03/2021 OS #38 -Revised Wildflower - Farmhouse - Sheets- signed
06/03/2021 OS #38 - PERMIT APP
06/14/2021 Approved Plans APPROVED PLOT PLAN
06/14/2021 Approved Plans APPROVED TRUSS DRAWINGS
06/14/2021 Approved Plans APPROVED TRUSS LAYOUT
06/14/2021 Permit Codes Residential Plan Review
06/14/2021 Approved Plans APPROVED PLANS
06/14/2021 Permit Codes Residential Plan Review
06/14/2021 Permit DS Building Permit
06/14/2021 Receipt Receipt for transaction:2021-004406
09/01/2021 M L Crose 2114 SW Rutherford Dr LSMO Clayton Permit 2021-2885 3rd Party Footing Inspection Report 8-25-21
09/02/2021 Letter INSPECTION SUMMARY
10/15/2021 Letter INSPECTION SUMMARY
10/22/2021 Receipt Receipt for transaction: 2021-008192
12/20/2021 Letter INSPECTION SUMMARY
01/05/2022 Letter INSPECTION SUMMARY
01/19/2022 Letter INSPECTION SUMMARY
01/19/2022 Letter INSPECTION SUMMARY
01/19/2022 Letter INSPECTION SUMMARY
01/28/2022 38 Osage Field Issue Letter
01/28/2022 Letter INSPECTION SUMMARY
01/28/2022 Letter INSPECTION SUMMARY
03/01/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/25/2022 Receipt Receipt for transaction:2022-002360
04/25/2022 38 Osage Field Issue Letter#2
04/26/2022 Letter INSPECTION SUMMARY
04/27/2022 Letter Codes Temporary Certificate of Occupancy
04/27/2022 Letter INSPECTION SUMMARY
05/26/2022 Letter Codes Temporary Certificate of Occupancy
05/26/2022 Email Osage Single Family Water Meters and TCO's
06/09/2022 Letter INSPECTION SUMMARY
06/13/2022 Letter Codes Final Certificate of Occupancy
06/13/2022 Letter Field Certificate of Occupancy
06/13/2022 Letter INSPECTION SUMMARY
06/13/2022 Letter INSPECTION SUMMARY
06/13/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home