Permit Application Status

PRRES20212569


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20212569
Building Permit - Residential
Certificate of Occupancy
HUNT MIDWEST RESIDENTIAL LLC
NEW SINGLE FAMILY
NEW HOUSE - SUSPENDED SLAB - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
05/19/2021
06/22/2021
11/17/2021
10/13/2022
Locations
Contacts
Olympus Custom Homes Inc, Address:1611 Ashton Circle  
BRUCE@OLYMPUSCUSTOMHOMES.COM  
HUNT MIDWEST RESIDENTIAL LLC, Address:8300 NE UNDERGROUND DR  
BUCKNER'S HEATING & COOLING LLC, Address:8576 N GREEN HILLS RD, Phone:(816) 436-1244  
Rivercrest Electric LLC, Address:PO Box 366  
Carlyle Plumbing, Inc, Address:120 LODWICK LN, Phone:(816) 792-8228  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/22/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 06/22/2021
8331507-Sewer Connection Fee $600.00 $600.00 Paid 06/22/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 06/22/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 06/22/2021
9110078-Valuation Fee New Single Family $1,701.93 $1,701.93 Paid 06/22/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 09/12/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 09/12/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 09/19/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/9/2021 (1:15) 8/9/2021 08/09/2021
Foundation Inspection - Residential Passed 9/8/2021 9/8/2021 09/08/2021
Underslab Plumbing Inspection - Residential Failed 10/6/2021 10/06/2021
Misc
Corrective Action Required
10/06/2021
4" MAIN CLEANOUT REQUIRED
Underslab Plumbing Inspection - Residential Passed 10/13/2021 10/13/2021 10/13/2021
Misc
Resolved
10/13/2021
4" MAIN CLEANOUT REQUIRED
Miscellaneous Inspection Passed 3/4/2022 03/04/2022
Misc
Informational
03/04/2022
Spoke with Bruce who informed me of supply issues and will be needing a permit extension. Mitchell Schwarz 03/04/2022 7:17 AM
Gas Service Inspection - Residential Passed 3/18/2022 03/18/2022
Electrical Service Inspection Failed 3/18/2022 03/18/2022
Misc
Corrective Action Required
03/18/2022
complete all electrical
All Rough Inspection - Residential Failed 3/18/2022 03/18/2022
Misc
Corrective Action Required
03/18/2022
-pfh to be completed per plans/design -provide blocking for sheathing breaks in garage -anchor bolts to be in the middle 1/3 of bottom plate -address corner studs over bored at E corner garage -nail all intersecting wall corners 12” OC -provide attic access for space above single car garage -fire block back garage wall into soffit -seal bottom plate penetration for EV electrical -fire block furr out for laundry -seal holes in laundry bottom plate -stud shoe for dwv at laundry -strike plates required back of steps garage entry -midway strap all dwv 2” or smaller in diameter -address dwv at master bath exterior wall over bored studs -fire block hvac chase master bath -complete framing for master tub -closet in master bath pan off return air and fire block ceiling line -fire block dead space left of master bath entry -complete fireplace installation -provide stud pack per plans at S great room wall -provide LIB per plans. (If using Gb method please indicate) -provide documentation for welds throughout -fire block right and left of dining room window -stud packs required per plans at dining room entry -seal penetrations in top plate above front door -sold block sheathing breaks bed 5 -protect all NM with in 6ft of attic access bed 4 closet -provide strike plates as needed bed 2 -solid block 48” on center under kitchen island per plans -solid block at cantilever basement -provide stud packs per plans at office and stairs -fire block back of stairwell, bottom of stairwell dead space 3 places -fire block vertically , horizontally every 10’ though out basement -fire block all soffit ends as needed -complete electrical -complete bath exhaust -address top plate boated threw for gas service -anchor all steal columns -provide stud packs per plans at unfinished basement back door -revise plans to show new location of bathroom in basement -seal hold in floor for tub above sump pump -support csst at T in soffit -un able to inspect covered deck/front patio. Remove sheathing
Erosion Control Inspection Residential Failed 3/18/2022 03/18/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/18/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Electrical Service Inspection Failed 4/4/2022 4/4/2022 04/04/2022
Misc
Corrective Action Required
03/18/2022
complete all electrical in under slab room
All Rough Inspection - Residential Failed 4/4/2022 4/4/2022 04/04/2022
Misc
Corrective Action Required
03/18/2022
-pfh to be completed per plans/design (uncover sheathing, anchor bolt to be of correct size, strapping at single car) -nail all intersecting wall corners 12” OC -provide attic access for space above single car garage (protect NM with in 6’ of attic access) -fire block furr out for laundry -midway strap all dwv 2” or smaller in diameter -all Let in bracing to be to code and plans -protect all NM with in 6ft of attic access bed 4 closet -solid block 48” on center under kitchen island per plans (must extend at least one joist bay past island above) -solid block at cantilever basement -fire block back of stairwell into soffit in basement -fire block vertically , horizontally every 10’ though out basement -fire block all soffit ends as needed (seal around beam) -complete electrical -un able to inspect covered deck/front patio. Remove sheathing
Electrical Service Inspection Not Ready 4/15/2022 04/15/2022
Misc
Corrective Action Required
04/04/2022
complete all electrical in under slab room
All Rough Inspection - Residential Failed 4/15/2022 04/15/2022
Misc
Corrective Action Required
04/04/2022
*Okay to insulate do not cover any items still needing inspection. * -pfh to be completed per plans/design (anchor bolt to be of correct size) -protect all NM with in 6ft of attic access bed 4 closet -complete electrical in unfinished area
Electrical Service Inspection Not Ready 4/20/2022 4/20/2022 04/20/2022
Misc
Corrective Action Required
04/15/2022
complete all electrical in under slab room
All Rough Inspection - Residential Passed 4/20/2022 4/20/2022 04/20/2022
Misc
Resolved
04/20/2022
Sewer Service Inspection - R Passed 5/17/2022 (2:00) 5/17/2022 05/17/2022
Water Service Inspection - R Partial 5/17/2022 05/17/2022
Misc
Informational
05/17/2022
pex ran from foundation roughly 20'
Water Service Inspection - R Failed 5/19/2022 (1:00) 5/19/2022 05/19/2022
Misc
Resolved
05/19/2022
pex ran from foundation roughly 20'
Misc
Corrective Action Required
05/19/2022
-Meter be 14”-18” from top of meter to pit ring and lid -copper must extend 10’ out of meter well before switching to pex
Water Service Inspection - R Failed 5/20/2022 (8:00) 5/20/2022 05/20/2022
Misc
Corrective Action Required
05/19/2022
-Meter be 14”-18” from top of meter to pit ring and lid -no gravel in meter pit
Water Service Inspection - R Passed 5/20/2022 05/20/2022
Misc
Resolved
05/20/2022
-Meter be 14”-18” from top of meter to pit ring and lid -no gravel in meter pit
Driveway Inspection Partial 6/22/2022 6/22/2022 06/22/2022
Misc
Informational
06/22/2022
On Wednesday 6.23.2022 I performed a driveway inspection and pass the sub-grade to pour concrete.
Erosion Control Inspection Residential Failed 8/3/2022 08/03/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
08/03/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/03/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. maintain erosion control and overgrown vegitation.
Electrical Service Inspection Passed 9/1/2022 9/1/2022 09/01/2022
Misc
Resolved
09/01/2022
complete all electrical in under slab room
Piers/Caissons Inspection - Residential Failed 9/1/2022 09/01/2022
Misc
Corrective Action Required
09/01/2022
address deck piers not inspected
Erosion Control Inspection Residential Failed 9/1/2022 09/01/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
09/01/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. maintain erosion control and overgrown vegitation.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/01/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
09/01/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Piers/Caissons Inspection - Residential Passed 9/13/2022 09/13/2022
Misc
Resolved
09/13/2022
address deck piers not inspected
Plot Plan Inspection Passed 9/13/2022 09/13/2022
Erosion Control Inspection Residential Failed 9/13/2022 09/13/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
09/13/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Resolved
09/13/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
09/13/2022
Erosion control to remain in compliance until sod is in place
Occupancy Inspection - Codes Residential Failed 9/13/2022 9/13/2022 09/13/2022
Misc
Corrective Action Required
09/13/2022
-address pending driveway inspection -obtain lawn irrigation permit -sod -splash blocks and sump pump discharge to extend 36” from foundation -seal all exterior penetrations -meter to be 14-18” from lid to top of meter -install spindles throughout home for inspection -GFCI protection for out under kitchen sink -spark rings at kitchen outlets where required by code -install security screws at rear door -handrail at deck stairs -deck steps to comply with code section -GFCI outlet in garage entry bath -outlet at garage entry, unfinished area left of water heater to be GFCI protected or labeled non GFCI and switches to single receptacle outlet -window fall protection for all up stairs bed rooms windows that require -afci breaker for living room sub panel -(2) 1/2” through bolts at each deck post to beam connection -address deck post to be contentious full height per plans -GFCI protection required at basement bathroom
Occupancy Inspection - Codes Residential Failed 9/16/2022 9/16/2022 09/16/2022
Misc
Corrective Action Required
09/13/2022
-address pending driveway inspection -obtain lawn irrigation permit -sod -splash blocks and sump pump discharge to extend 36” from foundation -outlet at garage entry, and unfinished area left of water heater to be GFCI protected or labeled non GFCI and switches to single receptacle outlet
Occupancy Inspection - Codes Residential Ready for Temp CO 9/19/2022 9/19/2022 09/19/2022
Misc
Corrective Action Required
09/16/2022
-address pending driveway inspection -obtain lawn irrigation permit -sod -splash blocks and sump pump discharge to extend 36” from foundation
Occupancy Inspection - Codes Residential Temporary C of O 9/19/2022 09/19/2022
Misc
Corrective Action Required
09/19/2022
-address pending driveway inspection -obtain lawn irrigation permit -sod -splash blocks and sump pump discharge to extend 36” from foundation
Erosion Control Inspection Residential Passed 10/13/2022 10/13/2022
Misc
Resolved
10/13/2022
Erosion control to remain in compliance until sod is in place
Driveway Inspection Passed 10/13/2022 10/13/2022
Misc
Informational
06/22/2022
On Wednesday 6.23.2022 I performed a driveway inspection and pass the sub-grade to pour concrete. 10-13-22 RH. Driveway meets LS specification.
Occupancy Inspection - Codes Residential Full C of O 10/13/2022 10/13/2022 10/13/2022
Misc
Resolved
10/13/2022
-address pending driveway inspection
Documents & Images
Date Uploaded File Type Document Name
05/19/2021 Application Form excise tax
05/19/2021 Application Form APPLICATION
05/21/2021 2021_05_17_21-207 Lot 745 Eagle Creek_Permit Set_Sealed
05/21/2021 lot 745 Eagle Creek Plot plan
05/21/2021 Permit Codes Residential Plan Review
05/27/2021 Revised PLANS Lot 745 Eagle Creek_2353 SW Hickory Ln
05/27/2021 Revised Plot plan lot 745 Eagle Creek, 2353 SW Hickory Ln
05/28/2021 Approved Plans APPROVED PLANS
05/28/2021 Plot Plan APPROVED PLOT PLAN
05/28/2021 Permit Codes Residential Plan Review
06/22/2021 Permit DS Building Permit
06/22/2021 Receipt Receipt for transaction:2021-004795
08/09/2021 Letter INSPECTION SUMMARY
09/08/2021 Letter INSPECTION SUMMARY
10/06/2021 Letter INSPECTION SUMMARY
10/13/2021 Letter INSPECTION SUMMARY
03/02/2022 Letter Codes 140 Day Letter
03/04/2022 Letter INSPECTION SUMMARY
03/18/2022 Letter INSPECTION SUMMARY
03/18/2022 Letter INSPECTION SUMMARY
03/18/2022 Letter INSPECTION SUMMARY
03/18/2022 Letter INSPECTION SUMMARY
03/18/2022 Letter INSPECTION SUMMARY
03/25/2022 2022_03_25_Olympus Custom Homes_Lot 745 Eagle Creek_LL Changes Letter
03/28/2022 2353 Sw Hickory Weld Certificate doc
04/04/2022 Letter INSPECTION SUMMARY
04/04/2022 Letter INSPECTION SUMMARY
04/15/2022 Letter INSPECTION SUMMARY
04/15/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
05/17/2022 Letter INSPECTION SUMMARY
05/17/2022 Letter INSPECTION SUMMARY
05/19/2022 Letter INSPECTION SUMMARY
05/20/2022 Letter INSPECTION SUMMARY
05/20/2022 Letter INSPECTION SUMMARY
05/20/2022 Letter INSPECTION SUMMARY
06/22/2022 Letter INSPECTION SUMMARY
08/03/2022 Letter INSPECTION SUMMARY
09/01/2022 Letter INSPECTION SUMMARY
09/01/2022 Letter INSPECTION SUMMARY
09/01/2022 Letter INSPECTION SUMMARY
09/12/2022 Eagle Creek, Lot 745 - deck piers & porch (1)
09/12/2022 Receipt Receipt for transaction:2022-007452
09/13/2022 Letter INSPECTION SUMMARY
09/13/2022 Letter INSPECTION SUMMARY
09/13/2022 Letter INSPECTION SUMMARY
09/13/2022 Letter INSPECTION SUMMARY
09/14/2022 2022_09_14_Olympus Custom Homes_21-207 Lot 745 Eagle Creek_Deck Post Fix
09/16/2022 Letter INSPECTION SUMMARY
09/19/2022 Receipt Receipt for transaction:2022-007626
09/19/2022 Letter Codes Temporary Certificate of Occupancy
10/13/2022 Letter INSPECTION SUMMARY
10/13/2022 Letter Codes Final Certificate of Occupancy
10/13/2022 Letter Field Certificate of Occupancy
10/13/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home