FIRST CHOICE CUSTOM HOMES LLC, Address:PO BOX 860072, Phone:(913) 449-8935  
DENNIS@FIRSTCHOICEHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ADVANCED ELECTRICAL LLC, Address:PO BOX 1573, Phone:(816) 347-8187  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK ST, Phone:(913) 829-8213  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $945.01 $945.01 Paid 05/21/2021
Right of Way Permit Fee $80.00 $80.00 Paid 05/21/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 05/21/2021
8331504-EFHB Middle Big Creek, Full $435.24 $435.24 Paid 05/21/2021
8331507-Sewer Connection Fee $390.00 $390.00 Paid 05/21/2021
Water Tap Fee $3,581.00 $3,581.00 Paid 05/21/2021
Water Meter Fee $455.54 $455.54 Paid 05/21/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/1/2021 (3:00) 7/1/2021 07/01/2021
Underslab Plumbing Inspection - Residential Passed 8/13/2021 8/13/2021 08/13/2021
Sewer Service Inspection - R Passed 8/25/2021 (10:00) 8/25/2021 08/25/2021
Water Service Inspection - R Passed 8/27/2021 (1:00) 8/27/2021 08/27/2021
Piers/Caissons Inspection - Residential Passed 12/16/2021 (1:00) 12/16/2021 12/16/2021
All Rough Inspection - Residential Failed 12/27/2021 12/27/2021 12/27/2021
Misc
Corrective Action Required
12/27/2021
UNABLE TO INSPECT COMPLETE 3" OC NAILING PATTERN OF SHEATHING TO PORTAL HEADER WITH EYEBROW ABOVE GARAGE DOOR
All Rough Inspection - Residential Failed 1/4/2022 1/4/2022 01/04/2022
Misc
Corrective Action Required
12/27/2021
-GARAGE PORTAL EXTERIOR OK TO COVER
All Rough Inspection - Residential Failed 3/24/2022 3/24/2022 03/24/2022
Misc
Corrective Action Required
01/04/2022
INSPECTION DENIED ADDRESS EROSION CONTROL AT REAR OF LOT, SILT FENCE DOWN AND THERE IS MUD IN ALLEY REPAIR AND MATAIN SILT FENCE CLEAN ALL MUD FROM ALLEY
Erosion Control Inspection Residential Failed 3/24/2022 3/24/2022 03/24/2022
Misc
Corrective Action Required
03/24/2022
INSPECTION DENIED ADDRESS EROSION CONTROL AT REAR OF LOT, SILT FENCE DOWN AND THERE IS MUD IN ALLEY REPAIR AND MATAIN SILT FENCE CLEAN ALL MUD FROM ALLEY
Electrical Service Inspection Passed 4/5/2022 4/5/2022 04/05/2022
Gas Service Inspection - Residential Failed 4/5/2022 4/5/2022 04/05/2022
Misc
Corrective Action Required
04/05/2022
GAS LINE BOND REQUIRED **PRESSURE OK**
All Rough Inspection - Residential Failed 4/5/2022 4/5/2022 04/05/2022
Misc
Corrective Action Required
03/24/2022
-trimmer studs garage PFH dbl car notched at anchor bolt, not full bearing -fireblock at furred wall stair wall top plate, open to attic space on garage wall -protection plate bottom plate pex for fridge kitchen pantry -fireblock great room fireplace at master bedroom closet wall, will be open to attic space in fireplace cavity -seal gas line floor penetration fireplace -solid block flashing sheathing breaks -provide nail protection plate at pex ceiling joist penetration master shower -provide stud shoes at DWV stud bores exterior wall 1st floor front biath -provide structural straps at all top plates bored 50% or more all interior load bearing walls and all exterior walls, straps min 1 1/2” wide, 16 gauge, with (4) 10D nails each side of strap and strap must span 6” each side of bore -seal top plate penetration for DWV 1st floor front bath -fireblock tub traps -support hip at kitchen as shown on plans -secure CSST gas line along joist at least 3” from end of joist see basement bedroom closet -20 amp circuit required at wet bar -have engineer address bores less than 2” from end of joist at multiple joists, see pex basement bath and wet bar, electrical at den and basement bedroom -have engineer address dbl 2x10 joist bored less 2” from end of joist at basement mech room -correct NM electrical to code for home run at basement bath wall, more than (3) NM through same bore, NM bundled at studs -all SCH 40 steel columns to be 3.5” per and -move the ceiling light box and smoke box at basement bed hall to ceiling line -add joist hangers to joist connection to dbl rim above basement bedroom egress window -nail all exterior sheathing per plans -unable to inspect covered deck framing with lid installed
Erosion Control Inspection Residential Partial 4/5/2022 4/5/2022 04/05/2022
Misc
Corrective Action Required
03/24/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Gas Service Inspection - Residential Passed 4/21/2022 4/21/2022 04/21/2022
Misc
Resolved
04/21/2022
All Rough Inspection - Residential Failed 4/21/2022 4/21/2022 04/21/2022
Misc
Corrective Action Required
04/05/2022
-provide stud shoes at DWV stud bores exterior wall 1st floor front bath -20 amp circuit required at wet bar, countertop receptacles placement per IRC E3901.4.1/NEC 210.52(C)(1) -have engineer address bores less than 2” from end of joist at multiple joists, see pex basement bath and wet bar, electrical at den and basement bedroom (repair per submitted engineer letter to install LSTA24 straps at bores, repair all locations throughout basement) -have engineer address dbl 2x10 joist bored less 2” from end of joist at basement mech room DWV (the submitted engineer letter only addresses the electrical bores and doesn’t call out this one for DWV) **OK TO INSULATE**
Erosion Control Inspection Residential Partial 4/21/2022 04/21/2022
Misc
Corrective Action Required
04/05/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
All Rough Inspection - Residential Passed 5/5/2022 5/5/2022 05/05/2022
Misc
Resolved
05/05/2022
Erosion Control Inspection Residential Partial 05/05/2022
Misc
Corrective Action Required
04/21/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Driveway Inspection Partial 6/13/2022 06/13/2022
Misc
Informational
06/13/2022
On 6.13.2022 Monday I performed a driveway inspection and pass the subgrade to pour concrete.
Sidewalk Inspection Partial 6/13/2022 06/13/2022
Misc
Informational
06/13/2022
On 6.13.2022 Monday I performed a sidewalk inspection and pass the sub-grade to pour concrete.
Plot Plan Inspection Passed 8/23/2022 08/23/2022
Occupancy Inspection - Codes Residential Failed 11/9/2022 11/9/2022 11/09/2022
Misc
Corrective Action Required
11/09/2022
DOOR LOCKED, NO LOCK BOX CODE PROVIDED, NO INTERIOR INSPECTION PERFORMED, EXTERIOR ITEMS ONLY -final driveway and sidewalk inspections required, contact development services to schedule -provide sod -provide gutters and downspouts -splash blocks -provide gravel base at egress well -light fixture at rear patio less than 8’ from patio must be sealed tamper resistant sealed type fixture -provide (2) 1/2” through bolts each post/beam connection and deck -nail off joist hangers at deck
Occupancy Inspection - Codes Residential Failed 11/11/2022 11/11/2022 11/11/2022
Misc
Corrective Action Required
11/09/2022
-provide secondary lock at rear slider -Kitchen counter outlet testing hot/neutral reverse -provide spark rings or adjust boxes at kitchen counter outlets -garage door must be self closing -label all breakers at service panel -AFCI protection at washer circuit -provide security screws at basement walkout, (2) 3” screws each hinge and strike plate -final driveway and sidewalk inspections required, contact development services to schedule -provide sod -provide gutters and downspouts -splash blocks -provide gravel base at egress well -light fixture at rear patio less than 8’ from patio must be sealed tamper resistant sealed type fixture -provide (2) 1/2” through bolts each post/beam connection and deck -nail off joist hangers at deck
Driveway Inspection Passed 11/15/2022 11/15/2022
Misc
Informational
06/13/2022
On 6.13.2022 Monday I performed a driveway inspection and pass the subgrade to pour concrete. 11-15-22 RH. Driveway meets LS and ADA specification.
Sidewalk Inspection Passed 11/15/2022 11/15/2022
Misc
Informational
06/13/2022
On 6.13.2022 Monday I performed a sidewalk inspection and pass the sub-grade to pour concrete. 11-15-22 RH. Sidewalk meets LS and ADA specification.
Occupancy Inspection - Codes Residential Failed 4/7/2023 4/7/2023 04/07/2023
Misc
Corrective Action Required
11/11/2022
-garage door must be self closing (it will not close shut and lock) -outlet plate in utility room is not installed -provide security screws at basement walkout, (2) 3” screws each hinge and strike plate -water sprinkler permit is required for system already installed
Erosion Control Inspection Residential Passed 4/7/2023 04/07/2023
Misc
Resolved
04/07/2023
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Occupancy Inspection - Codes Residential Failed 4/11/2023 4/11/2023 04/11/2023
Misc
Corrective Action Required
04/07/2023
-provide security screws at basement walkout, (2) 3” screws each hinge -water sprinkler permit is required for system already installed
Irrigation Inspection Passed 4/12/2023 04/12/2023
Occupancy Inspection - Codes Residential Full C of O 4/12/2023 4/12/2023 04/12/2023
Misc
Resolved
04/12/2023
-provide security screws at basement walkout, (2) 3” screws each hinge -water sprinkler permit is required for system already installed
Documents & Images
Date Uploaded File Type Document Name
05/12/2021 Application Form Permit Application
05/12/2021 Application Form License Tax Form
05/13/2021 Approved Plans Approved Drawings
05/13/2021 Permit Codes Residential Plan Review
05/21/2021 Plot Plan Approved Plot Plan
05/21/2021 Permit Codes Residential Plan Review
05/21/2021 Permit DS Building Permit
05/21/2021 Receipt Receipt for transaction:2021-003380
07/01/2021 Letter INSPECTION SUMMARY
08/13/2021 Letter INSPECTION SUMMARY
08/25/2021 Letter INSPECTION SUMMARY
08/27/2021 Letter INSPECTION SUMMARY
12/16/2021 Letter INSPECTION SUMMARY
12/27/2021 Letter INSPECTION SUMMARY
01/04/2022 Letter INSPECTION SUMMARY
03/24/2022 Letter INSPECTION SUMMARY
03/24/2022 Letter INSPECTION SUMMARY
04/05/2022 Letter INSPECTION SUMMARY
04/05/2022 Letter INSPECTION SUMMARY
04/05/2022 Letter INSPECTION SUMMARY
04/05/2022 Letter INSPECTION SUMMARY
04/13/2022 1828 SW Sage Canyon Rd Sprinkler ROW LS
04/13/2022 1828 SW Sage Canyon Approved Plot Plan
04/20/2022 DW LETTER McKinley Cottage 1828 SW Sage Canyon Rd
04/21/2022 Letter INSPECTION SUMMARY
04/21/2022 Letter INSPECTION SUMMARY
04/21/2022 Letter INSPECTION SUMMARY
05/03/2022 DW ROUGH IN ITEM #2 McKinley Cottage 1828 SW Sage Canyon Rd 5-2-22
05/05/2022 Letter INSPECTION SUMMARY
05/05/2022 Letter INSPECTION SUMMARY
06/13/2022 Letter INSPECTION SUMMARY
06/13/2022 Letter INSPECTION SUMMARY
08/22/2022 Plot Plan Approved As Graded Plot Plan
08/23/2022 Letter INSPECTION SUMMARY
11/09/2022 Letter INSPECTION SUMMARY
11/11/2022 Letter INSPECTION SUMMARY
11/15/2022 Letter INSPECTION SUMMARY
11/15/2022 Letter INSPECTION SUMMARY
04/04/2023 Letter Codes 140 Day Letter
04/07/2023 Letter INSPECTION SUMMARY
04/07/2023 Letter INSPECTION SUMMARY
04/11/2023 Letter INSPECTION SUMMARY
04/12/2023 Letter INSPECTION SUMMARY
04/12/2023 Letter Field Certificate of Occupancy
04/12/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home