Permit Application Status

PRRES20212347


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20212347
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ENG. FLOOR SYSTEM - FINISHED AND UNFINISHED BASEMENT - COVERED DECK UPDATED ADDRESS, IT IS 146 NW AMBERSHAM DR. PLANS DO NOT HAVE CORRECT ADDRESS, OK TO INSPECT Brandon Kalwei 06/18/2021 8:24 AM
05/07/2021
06/09/2021
11/06/2021
02/09/2023
Locations
Contacts
KC CUSTOM HOMES, Address:406 NW DONOVAN RD, Phone:(816) 564-5149  
Steve Froehlich, Address:406 NW Donovan Rd  
STEVE@KC-CUSTOMHOMES.COM  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
THE SOLAR GUYS, Address:6114 MO-9 HWY STE C1, Phone:(913) 424-2112  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
Not shown for privacy reasons.
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $570.00 $570.00 Paid 06/09/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/09/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 06/09/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 06/09/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 06/09/2021
9110078-Valuation Fee New Single Family $1,220.45 $1,220.45 Paid 06/09/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 03/31/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/10/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/17/2021 (11:30) 6/17/2021 06/17/2021
Misc
Informational
06/17/2021
UFER LOCATED SOUTH FOUNDATION WALL 2' FROM FRONT CORNER
Underslab Plumbing Inspection - Residential Passed 8/18/2021 8/18/2021 08/17/2021
Misc
Corrective Action Required
08/17/2021
LOT 96 2003 KILLARNEY SPRAY PAINTED ON FOUNDATION 146 AMBERSHAM ADDRESS ON PERMIT
Sewer Service Inspection - R Passed 9/1/2021 09/01/2021
Water Service Inspection - R Passed 9/7/2021 (1:00) 9/7/2021 09/07/2021
Erosion Control Inspection Residential Failed 9/7/2021 09/07/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/07/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER - - STREET CLEANUP REQUIRED -
Erosion Control Inspection Residential Failed 2/15/2022 2/15/2022 02/15/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/07/2021
**9-7-22 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER - - STREET CLEANUP REQUIRED -
DCM5 ESC INSP DENIED
Corrective Action Required
02/15/2022
**2-15-22 REQUESTED INSPECTION DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -PROVIDE EROSION CONTROL METHODS AT PERIMETER OF LOT, GRAVEL FILTER WITH MIN 6" OF LIFT OF 3/4" GRAVEL, PROTECT SWALE IN BACK, CLEAN SILT FROM STREET. EROSION CONTROL TO BE COMPLIANT WITHIN 2 BUSINESS DAYS
All Rough Inspection - Residential Failed 2/15/2022 2/15/2022 02/15/2022
Miscellaneous Correction
Corrective Action Required
02/15/2022
**2-15-22 REQUESTED INSPECTION DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -PROVIDE EROSION CONTROL METHODS AT PERIMETER OF LOT, GRAVEL FILTER WITH MIN 6" OF LIFT OF 3/4" GRAVEL, PROTECT SWALE IN BACK, CLEAN SILT FROM STREET. EROSION CONTROL TO BE COMPLIANT WITHIN 2 BUSINESS DAYS. NO INSPECTIONS WILL BE PERFORMED UNTIL IN COMPLIANCE
Gas Service Inspection - Residential Failed 2/22/2022 02/22/2022
Misc
Corrective Action Required
02/22/2022
NO GAS LINE INSTALLED PROVIDE GAUGE & MIN 10 PSI FOR 15 MINUTES
Electrical Service Inspection Passed 2/22/2022 02/22/2022
All Rough Inspection - Residential Failed 2/22/2022 2/22/2022 02/22/2022
Miscellaneous Correction
Resolved
02/22/2022
**2-15-22 REQUESTED INSPECTION DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -PROVIDE EROSION CONTROL METHODS AT PERIMETER OF LOT, GRAVEL FILTER WITH MIN 6" OF LIFT OF 3/4" GRAVEL, PROTECT SWALE IN BACK, CLEAN SILT FROM STREET. EROSION CONTROL TO BE COMPLIANT WITHIN 2 BUSINESS DAYS. NO INSPECTIONS WILL BE PERFORMED UNTIL IN COMPLIANCE
Miscellaneous Correction
Corrective Action Required
02/22/2022
-Provide 2 rows 16d sinkers 3” oc at top plate to header at pfh per detail -Protect nm at garage corner less than 1.25” to face of stud -Support hip and ridge at 2 car bay -Address rafters not connected to ceiling joists at garage -Fireblock tops dead spaces at garage/stairwell and use approved materials at ceiling line -Address double 2x10 at single car bay/double bay walkway taper cut greater than 1/4th depth -Fireblock ceiling line at single car bay window -Provide anchor bolt at end of plate in single car bay back wall -Anchor bolts to be in middle third of plate in single car bay -Address walls not connected at top plate at kitchen/single car garage -Provide lateral restraint for all ceiling joists above walls -Provide lateral restraint for double LVL at entry -Land electrical at powder room ceiling -Provide proper slope at dwv in attic space -Provide attic access per code -LIB per plans -Protect nm less than 1.25” to face of stud in laundry -Support hip rafters at top in great room -Seal top plate penetration at breakfast -Solid block and nail horizontal seams at exterior sheathing throughout -Protect electrical and seal bottom plate penetrations at master closet -Address over notched ceiling joists at master closet front corners -Address valley rafter not bearing 75% -Support hip and ridge at master closet -Use approved materials for ceiling line fireblocking throughout -Seal plate and floor penetrations in master shower/tub -Fireblock ceiling line at master shower/tub -Protect nm in master vanity less than 1.25” to face of stud -Address double LVLs taper cut greater than 1/4 and master bed -Address rafters over notched at master bed window -Identify ufer at both points of termination -Secure att 2” and smaller dwv at midpoint -Use specified hangers at I joist to LVL at mechanical room -Protect nm at top plate in bed 2 bath -Address over notched studs at exterior basement wall bed 2 -Complete fur downs at hvac bed 2 -Fireblock ceiling line basement bath/stairs -Fireblock dead space at basement powder room -Complete doorway to closed off powder room -Address floor joists with no bearing wall support south stair wall -Nail exterior sheathing -Provide CS-PF wall bracing per plan breakfast nook & great room ( 11 1/4 header per plan ) -Install missing doors -Provide electrical nail guard behind master bed door & master vanity -Expose covered deck & porch for inspection -Anchor bolts shall be in middle 1/3 the width plate -Provide 4" bath exhaust per code -Replaced damaged bath exhaust flex in Bed 2 bath basement -Provide clearance can light to DWV basement bath 2 -Provide anchor bolt within 12" of plate break Bed 2 south wall -Provide soffit HVAC duct work bed 2 -Address notched LVL header basement sliding glass door
Gas Service Inspection - Residential Failed 3/16/2022 03/16/2022
Misc
Corrective Action Required
02/22/2022
PROVIDE BOND GAS LINE PRESSURE STEADY AT 20 PSI
All Rough Inspection - Residential Not Ready 3/16/2022 3/16/2022 03/16/2022
Miscellaneous Correction
Corrective Action Required
02/22/2022
-Provide 2 rows 16d sinkers 3” oc at top plate to header at pfh per detail ( NOT DONE ) -Protect nm at garage corner less than 1.25” to face of stud 9 NOT DONE ) -Fireblock tops dead spaces at garage/stairwell and use approved materials at ceiling line : NOT DONE: ( 2018 IRC R302.11.1 FIREBLOCKING MATERIALS ) -Fireblock ceiling line at single car bay window ( NOT DONE ) -Land electrical at powder room ceiling ( not done ) -Protect nm less than 1.25” to face of stud in laundry ( not done ) -Protect electrical at master closet (NOT DONE SOUTH WALL ) -Address valley rafter not bearing 75% ( NO ENGINEERS LETTER) -Support hip and ridge at master closet ( no engineers letter )! -Use approved materials for ceiling line fireblocking throughout ( not done ) -Fireblock ceiling line at master shower/tub ( not done ) -Address double LVLs taper cut greater than 1/4 and master bed ( no engineers letter ) -Address rafters over notched at master bed window ( No engineer letter ) -Identify ufer at both points of termination ( green tape ) -Protect nm at top plate in bed 2 bath south wall (Not done ) -Provide CS-PF wall bracing per plan breakfast nook & great room ( 11 1/4 header per plan ) : engineer to address header : -Install Front door -Provide electrical nail guard behind master bed door & master vanity ( not done) -Expose covered deck & porch for inspection -Provide clearance can light to DWV basement bath 2 ( provide shield ) -Provide soffit HVAC duct work bed 2 ( fire block at ceiling line )
Gas Service Inspection - Residential Passed 4/1/2022 04/01/2022
Misc
Resolved
04/01/2022
All Rough Inspection - Residential Passed 4/1/2022 4/1/2022 04/01/2022
Miscellaneous Correction
Resolved
04/01/2022
Driveway Inspection Partial 4/13/2022 4/13/2022 04/13/2022
Misc
Informational
04/13/2022
Forms were placed and aggregate was present and compacted. Combined, the 2 driveways were over 36 feet wide. Dan removed the wings and now we are under 34 feet wide. RP 4-13-22
Piers/Caissons Inspection - Residential Failed 4/14/2022 (2:00) 4/14/2022 04/14/2022
Misc
Corrective Action Required
04/14/2022
ADDRESS GRADE BEAM AT COVERED DECK PIERS SHOWN ON CITY APPROVED PLANS
Piers/Caissons Inspection - Residential Passed 4/15/2022 04/15/2022
Misc
Informational
04/15/2022
(3) 24 x 36 COVERED DECK PIERS ADDRESS UNCOVERED DECK NOT ON CITY APPROVED PLANS (2) 24 X 36 PIERS NOT ON PLANS
Sidewalk Inspection Partial 4/18/2022 4/18/2022 04/18/2022
Misc
Informational
04/18/2022
Forms were placed and aggregate was present and compacted. RP 4-18-22
Driveway Inspection Passed 4/22/2022 4/22/2022 04/22/2022
Misc
Informational
04/13/2022
Forms were placed and aggregate was present and compacted. Combined, the 2 driveways were over 36 feet wide. Dan removed the wings and now we are under 34 feet wide. RP 4-13-22
Misc
Informational
04/22/2022
Finished driveways meet LS and ADA specs. RP 4-22-22
Sidewalk Inspection Passed 4/29/2022 4/29/2022 05/10/2022
Misc
Informational
04/18/2022
Forms were placed and aggregate was present and compacted. RP 4-18-22
Misc
Informational
05/10/2022
Sidewalk meets LS and Ada specs. 5/10/22 ES
Erosion Control Inspection Residential Failed 2/18/2022 10/11/2022 10/11/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/15/2022
**9-7-22 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER - - STREET CLEANUP REQUIRED -
DCM5 ESC INSP DENIED
Corrective Action Required
02/15/2022
**2-15-22 REQUESTED INSPECTION DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -PROVIDE EROSION CONTROL METHODS AT PERIMETER OF LOT, GRAVEL FILTER WITH MIN 6" OF LIFT OF 3/4" GRAVEL, PROTECT SWALE IN BACK, CLEAN SILT FROM STREET. EROSION CONTROL TO BE COMPLIANT WITHIN 2 BUSINESS DAYS
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/11/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE UNTIL SOD COMPLETE
Erosion Control Inspection Residential Passed 12/30/2022 12/30/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
12/30/2022
**9-7-22 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER - - STREET CLEANUP REQUIRED -
DCM5 ESC INSP DENIED
Resolved
12/30/2022
**2-15-22 REQUESTED INSPECTION DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -PROVIDE EROSION CONTROL METHODS AT PERIMETER OF LOT, GRAVEL FILTER WITH MIN 6" OF LIFT OF 3/4" GRAVEL, PROTECT SWALE IN BACK, CLEAN SILT FROM STREET. EROSION CONTROL TO BE COMPLIANT WITHIN 2 BUSINESS DAYS
DCM2 ESC DEFICIENT INSTALLATION
Resolved
12/30/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE UNTIL SOD COMPLETE
Occupancy Inspection - Codes Residential Failed 12/30/2022 12/30/2022 12/30/2022
Misc
Corrective Action Required
12/30/2022
-obtain lawn irrigation permit -security screws at rear doors 2 per hinge and strike plate -spark rings at counter top outlets where required in kitchen and prep kitchen -lable all non GFCI receptacles in unfinished spaces -GFCI outlet in single car garage nearest garage door will not reset -spark rings right and left of basement slider -secondary locking device at rear sliders -provide fire protection for engineered I-joist in unfinished spaces per section R302.13 -provide lock outs for breakers on hardwired appliances in kitchen and water heater -provide missing hangers at deck joists -provide missing nails at deck joist hangers -provide (2) 1/2” through bolts at each deck post to beam connection -siding from grade to be 6” see S side of house -sump pump discharge to extend 36” from foundation -deck stairs great than 7 3/4” see bottom step -provide engineering inspection and design for retaining wall over 4’ -provide as built plot plan -secure A/c whip up off of ground -bring water meter to grade (must maintain 14”-18” from meter to lid
Occupancy Inspection - Codes Residential Failed 1/6/2023 1/6/2023 01/06/2023
Misc
Corrective Action Required
12/30/2022
-obtain lawn irrigation permit -security screws at rear doors 2 per hinge and strike plate -provide fire protection for engineered I-joist in unfinished spaces per section R302.13 -provide lock outs for breakers on hardwired appliances in kitchen and water heater -provide engineering inspection and design for retaining wall over 4’ -provide as built plot plan DO NOT OCCUPY
Occupancy Inspection - Codes Residential Temporary C of O 1/10/2023 1/10/2023 01/10/2023
Misc
Corrective Action Required
01/06/2023
-provide engineering inspection and design for retaining wall over 4’ -provide as built plot plan
Plot Plan Inspection Passed 2/9/2023 02/09/2023
Occupancy Inspection - Codes Residential Full C of O 2/9/2023 02/09/2023
Misc
Resolved
02/09/2023
-provide engineering inspection and design for retaining wall over 4’ -provide as built plot plan
Documents & Images
Date Uploaded File Type Document Name
05/10/2021 Permit Codes Residential Plan Review
05/10/2021 Permit Codes Residential Plan Review
05/10/2021 Permit Codes Residential Plan Review
05/10/2021 Application Form APPLICATION
05/10/2021 Application Form excise tax
05/24/2021 Approved Plans APPROVED TRUSS LAYOUT
06/02/2021 Approved Plans APPROVED PLANS
06/02/2021 Permit Codes Residential Plan Review
06/09/2021 Permit DS Building Permit
06/09/2021 Receipt Receipt for transaction:2021-004206
06/17/2021 Letter INSPECTION SUMMARY
06/18/2021 Approved Plans approved joist layout
06/18/2021 Plot Plan APPROVED UPDATED PLOT PLAN
08/17/2021 Letter INSPECTION SUMMARY
09/01/2021 Letter INSPECTION SUMMARY
09/07/2021 Letter INSPECTION SUMMARY
09/07/2021 Letter INSPECTION SUMMARY
09/22/2021 Letter DS Building Permit
02/15/2022 Letter INSPECTION SUMMARY
02/15/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
02/23/2022 Letter INSPECTION SUMMARY
02/23/2022 Letter INSPECTION SUMMARY
03/10/2022 96 Woodside Ridge Driveway Revision
03/10/2022 Engineering Report for Inspection Deficiencies
03/16/2022 Letter INSPECTION SUMMARY
03/16/2022 Letter INSPECTION SUMMARY
03/24/2022 Plot Plan APPROVED PLOT PLAN
03/30/2022 Engineering Framing Inspection Letter
03/31/2022 Receipt Receipt for transaction:2022-001797
04/01/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
04/13/2022 Letter INSPECTION SUMMARY
04/14/2022 Letter INSPECTION SUMMARY
04/15/2022 Deck Pier Letter
04/15/2022 Letter INSPECTION SUMMARY
04/18/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
09/27/2022 Letter Codes 140 Day Letter
10/11/2022 Letter INSPECTION SUMMARY
12/30/2022 Letter INSPECTION SUMMARY
12/30/2022 Letter INSPECTION SUMMARY
01/06/2023 Letter INSPECTION SUMMARY
01/10/2023 Certificate/License Codes Temporary Certificate of Occupancy
01/10/2023 Receipt Receipt for transaction:2023-000155
01/10/2023 Certificate/License Codes Temporary Certificate of Occupancy
01/13/2023 McEntire Retaining Wall Engineering
01/13/2023 Approved Plans approved retaining wall drawings
01/20/2023 SF-7020 (McEntire) 2 REV 1-12-23
01/20/2023 Plot Plan APPROVED AS BUILT PLOT PLAN
02/09/2023 Letter INSPECTION SUMMARY
02/09/2023 Letter Field Certificate of Occupancy
02/09/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home