Permit Application Status

PRRES20211027


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20211027
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - PARTIAL FINISHED BASEMENT - COVERED DECK
03/09/2021
03/16/2021
09/12/2021
06/15/2023
Locations
Contacts
IQ CONSTRUCTION, Address:P O BOX 6423, Phone:(816) 582-8100  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
SAFEHOUSE ELECTRIC COMPANY, Address:P O BOX 1833, Phone:(816) 935-8113  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
BSHELTON@IQHOMEBUILDERS.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/18/2021 03/16/2021
Kim Brennan
Deck location
Corrective Action Required
03/16/2021

Deck location, with dimensions to property lines must be provided on the plot plan. Please show this as a covered deck
Residential Plan Review Approved 03/18/2021 03/16/2021
Kim Brennan
Plot Plan Review Rejected 03/18/2021 03/16/2021
Kim Brennan
Deck location
Corrective Action Required
03/16/2021

Deck location, with dimensions to property lines must be provided on the plot plan. Please show this as a covered deck
Residential Plan Review Approved 03/18/2021 03/16/2021
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $967.01 $967.01 Paid 03/16/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 03/16/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 03/16/2021
8331507-Sewer Connection Fee $420.00 $420.00 Paid 03/16/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 03/16/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 03/16/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/20/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/20/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 01/20/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/31/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 09/28/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 10/21/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 05/19/2023
Outstanding Fees Amount Paid Owing Date Paid


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/19/2021 (3:00) 4/19/2021 04/19/2021
Erosion Control Inspection Residential Failed 04/19/2021
Misc
Corrective Action Required
04/19/2021
-Establish erosion control methods within 48 hours -immediate street cleanup required -no further inspections until issues are resolved
Miscellaneous Inspection Failed 04/19/2021
Misc
Corrective Action Required
04/19/2021
Post site address
Underslab Plumbing Inspection - Residential Failed 5/17/2021 5/17/2021 05/17/2021
Misc
Corrective Action Required
05/17/2021
Unable to determine code compliant installation, inspection area is underwater
Underslab Plumbing Inspection - Residential Passed 5/19/2021 5/19/2021 05/18/2021
Misc
Resolved
05/18/2021
Unable to determine code compliant installation, inspection area is underwater
Sewer Service Inspection - R Passed 5/24/2021 (1:45) 5/24/2021 05/24/2021
Water Service Inspection - R Partial 5/26/2021 05/25/2021
Misc
Informational
05/25/2021
Partial water approval from structure to metallic connection customer side of meter
Water Service Inspection - R Passed 05/26/2021
Misc
Resolved
05/26/2021
Partial water approval from structure to metallic connection customer side of meter
All Rough Inspection - Residential Partial 7/16/2021 7/16/2021 07/16/2021
Misc
Informational
07/16/2021
**7/16/21 - GARAGE PORTAL EXTERIOR OK TO COVER**
Erosion Control Inspection Residential Failed 08/03/2021
Misc
Resolved
08/03/2021
-Establish erosion control methods within 48 hours -immediate street cleanup required -no further inspections until issues are resolved
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/03/2021
8-3-21 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -ESTABLISH EROSION CONTROL AT PERIMETER OF LOT -POST ADDRESS -NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL IN COMPLIANCE
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/03/2021
8-3-21 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -ESTABLISH EROSION CONTROL AT PERIMETER OF LOT -POST ADDRESS -NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL IN COMPLIANCE
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/03/2021
8-3-21 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -ESTABLISH EROSION CONTROL AT PERIMETER OF LOT -POST ADDRESS -NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL IN COMPLIANCE
Piers/Caissons Inspection - Residential Failed 8/3/2021 (10:30) 8/3/2021 08/03/2021
Miscellaneous Correction
Corrective Action Required
08/03/2021
-MISSING 3RD INTERMEDIATE PIER PER PLANS -CLEAN LOOSE SOIL FROM BOTTOM OF PIER -ESTABLISH EROSION CONTROL AT PERIMETER OF LOT -POST ADDRESS -NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL IN COMPLIANCE
All Rough Inspection - Residential Not Ready 9/10/2021 9/10/2021 09/10/2021
Misc
Informational
07/16/2021
**7/16/21 - GARAGE PORTAL EXTERIOR OK TO COVER**
Miscellaneous Correction
Corrective Action Required
09/10/2021
NOT READY -Provide city approved, stamped plans on site for inspection
Electrical Service Inspection Failed 9/10/2021 9/10/2021 09/10/2021
Miscellaneous Correction
Corrective Action Required
09/10/2021
-Provide city approved, stamped plans on site for inspection
Gas Service Inspection - Residential Failed 9/10/2021 9/10/2021 09/10/2021
Miscellaneous Correction
Corrective Action Required
09/10/2021
-Provide city approved, stamped plans on site for inspection
All Rough Inspection - Residential Failed 9/13/2021 9/13/2021 09/13/2021
Misc
Informational
09/10/2021
**7/16/21 - GARAGE PORTAL EXTERIOR OK TO COVER**
Miscellaneous Correction
Corrective Action Required
09/10/2021
-Attic access garage -Protect service cable secured less than 1.25” from face of studs at panel -Identify ufer conductor and gas bond at both ends -Seal upward penetrations at powder room -Fireblock top of chase in garage -(4) studs for bearing at triple lvl in family room -2x6 wall to be 12” oc family room full height wall -4x4 parallam column between 1st and upper level per plans -Address location of upper level beam different than plans and missing upset beam for valley support -upward penetration at upstairs bath -(3) bearing studs at both upstairs bathrooms and solid block to beam below -Rafter ties at rafters over living room/ full height wall -seal plate penetrations and gaps at dead space bed 2 -FB gap at ceiling framing master bed north -Address roof bearing on non load bearing wall master closet -Fb ceiling line bed 3 south -Seal upward penetrations at kitchen -Support roof sheathing at valley in living room -Seal through floor penetration behind fridge -(3) 2x6 strut at lvl ridge beam at kitchen -(1) 14” and (2) 12” lvl ridge beam per plan -Support 2x6 rafters in living room per plan -Hangers at (3) 2x6 beam. -Seal plate penetration at living room East and south -FB beam web at entry -2x6 I brace at ridge beam covered deck -Support ridge beam at master bath -Clarify/supply number of bearing studs needed at steel beam at stairwell -(4) bearing studs required at stairwell/ lower living room -Fireblock dead space at basement closet/fur out wall -Fireblock top of fur out wall in closet and seal gaps at bathroom -Seal nm penetration in blocking between joists basement closet -Fireblock vertical 10’ oc max at fur out walls -Flash and install egress window -Seal upward penetrations at basement linen closet -Smoke detector inside and outside of basement bedroom -LIB per plan -Soffit vents per code
Gas Service Inspection - Residential Passed 9/13/2021 9/13/2021 09/13/2021
Miscellaneous Correction
Resolved
09/13/2021
-Provide city approved, stamped plans on site for inspection
Electrical Service Inspection Passed 9/13/2021 9/13/2021 09/13/2021
Miscellaneous Correction
Resolved
09/13/2021
-Provide city approved, stamped plans on site for inspection
All Rough Inspection - Residential Failed 9/27/2021 9/27/2021 09/27/2021
Misc
Informational
09/13/2021
**7/16/21 - GARAGE PORTAL EXTERIOR OK TO COVER**
Miscellaneous Correction
Corrective Action Required
09/13/2021
-Protect service cable secured less than 1.25” from face of studs at panel -Fireblock top of chase in garage-SEAL GAPS AND PENETRATIONS -(4) studs for bearing at triple lvl in family room -4x4 parallam column between 1st and upper level per plans -Address location of upper level beam different than plans and missing upset beam for valley support- -Rafter ties at rafters over living room/ full height wall-PROVIDE H2.5s OR RAFTER TIES PER PLAN -Address roof bearing on non load bearing wall master closet -Clarify/supply number of bearing studs needed at steel beam at stairwell -(1) 14” LVL, (2) 12” LVL ridge beam per plan or clarify with engineer -(4) bearing studs required at stairwell/ lower living room -Fireblock dead space at furout wall/ closet—SEE OUTSIDE OF CLOSET SW -Fireblock vertical 10’ oc max at fur out walls-SEAL STUD PENETRATIONS AT THE 10’ SEPARATIONS AND TOP AT WINDOW -Flash and install egress window -LIB per plan- missing CSPF at living room -Soffit vents per code
All Rough Inspection - Residential Not Ready 9/30/2021 9/30/2021 09/30/2021
Misc
Informational
09/27/2021
**7/16/21 - GARAGE PORTAL EXTERIOR OK TO COVER**
Miscellaneous Correction
Corrective Action Required
09/27/2021
-Fireblock top of chase in garage-SEAL GAPS AND PENETRATIONS-NOT DONE, SEE PEX AND GAS LINE -4x4 parallam column between 1st and upper level per plans -Rafter ties at rafters over living room/ full height wall-PROVIDE H2.5s OR RAFTER TIES PER PLAN-NOT DONE -(1) 14” LVL, (2) 12” LVL ridge beam per plan or clarify with engineer -LIB per plan- missing CSPF at living room -Soffit vents per code
All Rough Inspection - Residential Failed 10/13/2021 10/13/2021 10/13/2021
Misc
Resolved
10/13/2021
**7/16/21 - GARAGE PORTAL EXTERIOR OK TO COVER**
Miscellaneous Correction
Corrective Action Required
09/30/2021
-CSPF at living room-Complete nailing pattern at exterior-nail at rim joist and studs-see detail 1 on G4 **OK TO INSULATE
All Rough Inspection - Residential Passed 10/18/2021 10/18/2021 10/18/2021
Miscellaneous Correction
Resolved
10/18/2021
-CSPF at living room-Complete nailing pattern at exterior-nail at rim joist, header and studs-see detail 1 on G4 **OK TO INSULATE
Piers/Caissons Inspection - Residential Passed 10/22/2021 (9:45) 10/22/2021 10/22/2021
Miscellaneous Correction
Resolved
10/22/2021
-MISSING 3RD INTERMEDIATE PIER PER PLANS -CLEAN LOOSE SOIL FROM BOTTOM OF PIER -ESTABLISH EROSION CONTROL AT PERIMETER OF LOT -POST ADDRESS -NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL IN COMPLIANCE
Driveway Inspection Partial 11/22/2021 11/22/2021 11/22/2021
Misc
Informational
11/22/2021
On 11/22/2021 I performed a driveway inspection and pass the subgrade to pour concrete. Contractor: Magnum Conrete, LLC
Sidewalk Inspection Partial 12/8/2021 12/8/2021 12/08/2021
Misc
Informational
12/08/2021
On Wednesday 12.08.2021 I performed a sidewalk inspection and pass the sub-grade to pour concrete
Occupancy Inspection - Codes Residential Failed 1/21/2022 1/21/2022 01/21/2022
Misc
Corrective Action Required
01/21/2022
ESTABLISH AND MAINTAIN EROSION CONTROL UNTIL SOD IN IN PLACE -obtain irrigation permit -driveway and sidewalk inspection to be completed -final grade and sod -splash blocks and sump pump discharge to be 36” from foundation -check water meter and siding from ground at time of final grade and sod -guard rail at front stairs where over 30” , 36” out -security screws at front door strike plates -GFCI protection required for dishwasher -outlet left of sink in master bath hot/neutral reverse -security screws at both rear doors -deck post to beam connections requires (2) 1/2” through bolts -label all non GFCI protected outlets in unfinished spaces
Occupancy Inspection - Codes Residential Not Ready 1/26/2022 1/26/2022 01/26/2022
Misc
Corrective Action Required
01/21/2022
ESTABLISH AND MAINTAIN EROSION CONTROL UNTIL SOD IN IN PLACE -obtain irrigation permit -driveway and sidewalk inspection to be completed -final grade and sod -splash blocks and sump pump discharge to be 36” from foundation -check water meter and siding from ground at time of final grade and sod -guard rail at front stairs where over 30” , 36” out -security screws at front door strike plates -GFCI protection required for dishwasher -outlet left of sink in master bath hot/neutral reverse -security screws at both rear doors -deck post to beam connections requires (2) 1/2” through bolts -label all non GFCI protected outlets in unfinished spaces -Inspection denied no erosion control present. Mitch schwarz 1/26/22 10:40
Erosion Control Inspection Residential Failed 1/26/2022 1/26/2022 01/26/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
01/26/2022
8-3-21 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -ESTABLISH EROSION CONTROL AT PERIMETER OF LOT -POST ADDRESS -NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL IN COMPLIANCE
DCM3 ESC REQUIRED 2 DAY
Resolved
01/26/2022
8-3-21 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -ESTABLISH EROSION CONTROL AT PERIMETER OF LOT -POST ADDRESS -NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL IN COMPLIANCE
DCM3 ESC REQUIRED 2 DAY
Resolved
01/26/2022
8-3-21 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -ESTABLISH EROSION CONTROL AT PERIMETER OF LOT -POST ADDRESS -NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL IN COMPLIANCE
DCM5 ESC INSP DENIED
Corrective Action Required
01/26/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. Erosion control must be present and maintained until time of final sod.
Erosion Control Inspection Residential Partial 2/1/2022 02/01/2022
DCM5 ESC INSP DENIED
Resolved
02/01/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. Erosion control must be present and maintained until time of final sod.
Misc
Informational
02/01/2022
EROSION CONTROL BACK IN COMPLIANCE Mitchell Schwarz 02/01/2022 8:46 AM
Plot Plan Inspection Passed 2/1/2022 02/01/2022
Occupancy Inspection - Codes Residential Temporary C of O 2/1/2022 2/1/2022 02/01/2022
Misc
Corrective Action Required
01/26/2022
*TCO UNTIL 04/01/22* -obtain irrigation permit -driveway and sidewalk inspection to be completed -sod -splash blocks and sump pump discharge to be 36” from foundation -check water meter and siding from ground at time of sod -deck post to beam connections requires (2) 1/2” through bolts
Driveway Inspection Passed 9/12/2022 09/12/2022
Misc
Informational
11/22/2021
On 11/22/2021 I performed a driveway inspection and pass the subgrade to pour concrete. Contractor: Magnum Conrete, LLC 9-12-22 RH. Driveway meets LS and ADA specification.
Sidewalk Inspection Passed 9/12/2022 09/12/2022
Misc
Informational
12/08/2021
On Wednesday 12.08.2021 I performed a sidewalk inspection and pass the sub-grade to pour concrete 9-12-22 RH. Sidewalk meets LS and ADA specification.
Erosion Control Inspection Residential Passed 9/12/2022 09/12/2022
Misc
Resolved
09/12/2022
EROSION CONTROL BACK IN COMPLIANCE Mitchell Schwarz 02/01/2022 8:46 AM
Occupancy Inspection - Codes Residential Not Ready 9/12/2022 9/12/2022 09/12/2022
Misc
Corrective Action Required
02/01/2022
TCO EXPIRED! SUBMIT TCO EXTENSION FORM AND PAY FEES BEFORE FURTHER INSPETIONS *TCO UNTIL 04/01/22* -pay fees -address siding from ground at rear of home -deck post to beam connections requires (2) 1/2” through bolts
Occupancy Inspection - Codes Residential Ready for Temp CO 10/21/2022 10/21/2022 10/21/2022
Misc
Corrective Action Required
09/12/2022
-pay fees -address siding from ground at rear of home -deck post to beam connections requires (2) 1/2” through bolts
Occupancy Inspection - Codes Residential Temporary C of O 10/21/2022 10/21/2022
Misc
Corrective Action Required
10/21/2022
-address siding from ground at rear of home
Occupancy Inspection - Codes Residential Ready for Temp CO 11/21/2022 11/21/2022
Misc
Corrective Action Required
10/21/2022
-address siding from ground at rear of home
Occupancy Inspection - Codes Residential Failed 5/19/2023 5/19/2023 05/19/2023
Misc
Corrective Action Required
11/21/2022
-reestablish sod where grading fixed
Plot Plan Inspection Passed 05/25/2023
Misc
Informational
05/25/2023
Grading issue addressed
Occupancy Inspection - Codes Residential Full C of O 6/15/2023 6/15/2023 06/15/2023
Misc
Resolved
06/15/2023
-reestablish sod where grading fixed
Documents & Images
Date Uploaded File Type Document Name
03/09/2021 Application Form Permit Application and License Tax Form
03/16/2021 Approved Plans Approved Drawings
03/16/2021 Letter Codes Residential Plan Review
03/16/2021 Plot Plan Approved Plot Plan
03/16/2021 Receipt Receipt for transaction:2021-001318
03/16/2021 Letter DS Building Permit
04/19/2021 Letter INSPECTION SUMMARY
04/19/2021 Letter INSPECTION SUMMARY
04/19/2021 Letter INSPECTION SUMMARY
05/17/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
05/24/2021 Letter INSPECTION SUMMARY
05/25/2021 Letter INSPECTION SUMMARY
05/26/2021 Letter INSPECTION SUMMARY
07/16/2021 Letter INSPECTION SUMMARY
08/03/2021 Letter INSPECTION SUMMARY
08/03/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
09/13/2021 Letter INSPECTION SUMMARY
09/13/2021 Letter INSPECTION SUMMARY
09/13/2021 Letter INSPECTION SUMMARY
09/27/2021 Letter INSPECTION SUMMARY
09/28/2021 Rough-In Inspection
09/30/2021 Letter INSPECTION SUMMARY
10/13/2021 Letter INSPECTION SUMMARY
10/18/2021 Letter INSPECTION SUMMARY
10/22/2021 Letter INSPECTION SUMMARY
11/22/2021 Letter INSPECTION SUMMARY
12/08/2021 Letter INSPECTION SUMMARY
01/20/2022 Receipt Receipt for transaction:2022-000332
01/21/2022 Letter INSPECTION SUMMARY
01/26/2022 Letter INSPECTION SUMMARY
01/26/2022 Letter INSPECTION SUMMARY
01/31/2022 Receipt Receipt for transaction:2022-000538
02/01/2022 Letter Codes Temporary Certificate of Occupancy
02/01/2022 Letter INSPECTION SUMMARY
02/01/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter Codes 10 Day Letter
09/28/2022 Receipt Receipt for transaction:2022-007874
10/21/2022 2346 SW Old Port Rd - Extension Form
10/21/2022 Certificate/License Codes Temporary Certificate of Occupancy
10/21/2022 Receipt Receipt for transaction:2022-008429
10/21/2022 Certificate/License Codes Temporary Certificate of Occupancy
11/02/2022 2346 SW Old Port Rd - Code Modification Request
04/10/2023 Letter Codes 10 Day Letter
05/19/2023 Certificate/License Codes Temporary Certificate of Occupancy
05/19/2023 Receipt Receipt for transaction:2023-003478
05/19/2023 Letter INSPECTION SUMMARY
05/25/2023 Letter INSPECTION SUMMARY
06/15/2023 Letter Field Certificate of Occupancy
06/15/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home