Summary
PRRES20210695
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - FINISHED AND UNFINISHED BASEMENT - UNCOVERED DECK
02/22/2021
02/24/2021
08/22/2021
12/03/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 02/25/2021 02/23/2021
Brandon Kalwei
Rear yard dimension
Corrective Action Required
02/23/2021

The rear yard demision(s) must be provided on the plot plan.
Sidewalks
Corrective Action Required
02/23/2021

Sidewalks with dimensions must be provided on the plot plan.
Basement egress
Corrective Action Required
02/23/2021

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan.
Basement opening elevations
Corrective Action Required
02/23/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. Has MBOE on MDP, cannot find on plot plan
Residential Plan Review Approved 02/25/2021 02/23/2021
Brandon Kalwei
07 Identify emergency escape openings from bedrooms
Corrective Action Required
02/23/2021

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) egress needed for bedroom #4
Plot Plan Review Rejected 02/24/2021 02/22/2021
Brandon Kalwei
Rear yard dimension
Corrective Action Required
02/22/2021

The rear yard demision(s) must be provided on the plot plan.
Sidewalks
Corrective Action Required
02/22/2021

Sidewalks with dimensions must be provided on the plot plan.
Basement egress
Corrective Action Required
02/22/2021

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan.
Basement opening elevations
Corrective Action Required
02/22/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. Has MBOE on MDP, cannot find on plot plan
Residential Plan Review Rejected 02/24/2021 02/22/2021
Brandon Kalwei
07 Identify emergency escape openings from bedrooms
Corrective Action Required
02/22/2021

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) egress needed for bedroom #4
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $872.90 $872.90 Paid 02/23/2021
8331507-Sewer Connection Fee $360.00 $360.00 Paid 02/23/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 02/23/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 02/23/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 02/23/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 02/23/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/26/2021 (11:30) 3/26/2021 03/26/2021
Misc
Informational
03/26/2021
UFER LOCATED FOUNDATION WALL REAR OF GARAGE
Underslab Plumbing Inspection - Residential Passed 4/20/2021 4/20/2021 04/20/2021
Gas Service Inspection - Residential Passed 6/17/2021 6/17/2021 06/17/2021
All Rough Inspection - Residential Failed 6/17/2021 6/17/2021 06/17/2021
Miscellaneous Correction
Corrective Action Required
06/17/2021
: PFH PORTAL FRAME, TRUSSES PORCH & COVERED PATIO ONLY : PFH Portal frame fasten top plate to header with 2 rows of 16D sinkers 3" OC per plan Spliced edges shall occur over and be nailed to common blocking within middle 24" of wall mid height one row of 3" OC Porch ok to cover lid Patio ok to cover lid
Sewer Service Inspection - R Passed 6/21/2021 (11:15) 6/21/2021 06/21/2021
Water Service Inspection - R Passed 6/25/2021 06/25/2021
Electrical Service Inspection Passed 7/9/2021 7/9/2021 07/09/2021
All Rough Inspection - Residential Failed 7/9/2021 7/9/2021 07/09/2021
Miscellaneous Correction
Corrective Action Required
06/17/2021
: PFH PORTAL FRAME, TRUSSES PORCH & COVERED PATIO ONLY : PFH Portal frame fasten top plate to header with 2 rows of 16D sinkers 3" OC per plan Spliced edges shall occur over and be nailed to common blocking within middle 24" of wall mid height one row of 3" OC Porch ok to cover lid Patio ok to cover lid
Miscellaneous Correction
Corrective Action Required
07/09/2021
Provide solid blocking at sheathing break garage at front stoop Provide 1 roof vent at covered de k per plan Nail studs at foyer Nail studs at intersecting wall Corners of braced wall panels Nail sheathing per code bed #2 Seal gap at top plate double wall laundry Seal dead space master water closet Provide anchor bolt end of plate at patio door Provide boca plate bed #3 closet Fire block vertical to horizontal bed # 4 west of window Tighten anchor bolts basement Seal gaps in fire blocking north wall Address 6 x 6 cedar post NOT full height continuous
All Rough Inspection - Residential Passed 7/14/2021 7/14/2021 07/14/2021
Miscellaneous Correction
Resolved
07/14/2021
: PFH PORTAL FRAME, TRUSSES PORCH & COVERED PATIO ONLY : PFH portal frame ok to cover Porch ok to cover lid Patio ok to cover lid
Miscellaneous Correction
Resolved
07/14/2021
Driveway Inspection Partial 7/26/2021 7/26/2021 07/26/2021
Misc
Informational
07/26/2021
Forms were placed and aggregate was present and compacted. Told them to stop washing out on the curbs. He told me he would clean it up. RP 7-26-21
Driveway Inspection Passed 7/30/2021 7/30/2021 07/30/2021
Misc
Informational
07/26/2021
Forms were placed and aggregate was present and compacted. Told them to stop washing out on the curbs. He told me he would clean it up. RP 7-26-21
Misc
Informational
07/30/2021
Finished driveway meets LS and ADA specs. RP 7-30-21
Sidewalk Inspection Failed 8/3/2021 08/03/2021
Misc
Corrective Action Required
08/03/2021
Forms were placed and aggregate was present and compacted. Water meter is located in the middle of the forms. Plumber needs to dig it back up and relocate it outside of the sidewalk. I talked with Mark Harding about the water meter and passed the info on to Jared from Summit Homes. RP 8-3-21
Water Service Inspection - R Passed 8/6/2021 08/06/2021
Sidewalk Inspection Partial 8/12/2021 8/12/2021 08/12/2021
Misc
Corrective Action Required
08/03/2021
Forms were placed and aggregate was present and compacted. Water meter is located in the middle of the forms. Plumber needs to dig it back up and relocate it outside of the sidewalk. I talked with Mark Harding about the water meter and passed the info on to Jared from Summit Homes. RP 8-3-21
Misc
Corrective Action Required
08/12/2021
Forms were placed and aggregate was present and compacted. Water meter was moved out of the sidewalk but will need to be raised. RP 8-12-21
Sidewalk Inspection Failed 8/23/2021 8/23/2021 08/23/2021
Misc
Corrective Action Required
08/12/2021
Forms were placed and aggregate was present and compacted. Water meter is located in the middle of the forms. Plumber needs to dig it back up and relocate it outside of the sidewalk. I talked with Mark Harding about the water meter and passed the info on to Jared from Summit Homes. RP 8-3-21
Misc
Corrective Action Required
08/12/2021
Forms were placed and aggregate was present and compacted. Water meter was moved out of the sidewalk but will need to be raised. RP 8-12-21
Misc
Corrective Action Required
08/23/2021
Sidewalk has different spacing for all 4 panels. Also has indentations and rough finish. Need to remove and replace. RP 8-23-21
Erosion Control Inspection Residential Failed 9/10/2021 09/10/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/10/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE UNTIL SOD COMPLETE -
Occupancy Inspection - Codes Residential Failed 9/10/2021 9/10/2021 09/10/2021
Miscellaneous Correction
Corrective Action Required
09/10/2021
Sidewalk inspection pending Provide sod & splash blocks Provide engineering on retaining wall over 4' Maintain silt fence until sod complete Address 6x6 cedar post covered deck not continuous per plan Obtain lawn irrigation permit & submit back flow certification Seal exterior light fixtures Seal exterior penetrations @ gas meter Seal top of AC disconnect & meter can Provide self closing & self latching door garage to dwelling Remove construction debris from yard & garage Tighten & shear off set screw back flow device at water shut off Complete concrete pad at deck stairs Provide step at patio slab 14" to 24" to grade Provide 6" clearance finished grade to wood siding Exterior drain tiles shall discharge 36" from foundation Provide gutters & downspouts
Occupancy Inspection - Codes Residential Temporary C of O 9/15/2021 9/15/2021 09/15/2021
Miscellaneous Correction
Corrective Action Required
09/10/2021
Sidewalk inspection pending Provide engineering on retaining wall over 4' Address 6x6 cedar post covered deck not continuous per plan Obtain lawn irrigation permit & submit back flow certification Seal exterior light fixtures ( rear patio) Remove construction debris from yard & patio Provide step at patio slab 14" to 24" to grade Provide 6" clearance finished grade to wood siding Exterior drain tiles shall discharge 36" from foundation Repair broken PVC @ sump discharge
Plot Plan Inspection Passed 9/15/2021 09/15/2021
Sidewalk Inspection Failed 10/7/2021 10/7/2021 10/07/2021
Misc
Corrective Action Required
08/23/2021
Forms were placed and aggregate was present and compacted. Water meter is located in the middle of the forms. Plumber needs to dig it back up and relocate it outside of the sidewalk. I talked with Mark Harding about the water meter and passed the info on to Jared from Summit Homes. RP 8-3-21
Misc
Corrective Action Required
08/23/2021
Forms were placed and aggregate was present and compacted. Water meter was moved out of the sidewalk but will need to be raised. RP 8-12-21
Misc
Corrective Action Required
08/23/2021
Sidewalk has different spacing for all 4 panels. Also has indentations and rough finish. Need to remove and replace. RP 8-23-21
Misc
Corrective Action Required
10/07/2021
Spoke Jarod at Summit Homes and let him know that all 4 panels need to be ripped out and replaced.
Occupancy Inspection - Codes Residential Failed 11/12/2021 11/12/2021 11/11/2021
Misc
Corrective Action Required
09/15/2021
PROVIDE ACCESS TO BACK YARD FOR INSPECTION Sidewalk inspection pending Address 6x6 cedar post covered deck not continuous per plan Obtain lawn irrigation permit & submit back flow certification Seal exterior light fixtures ( rear patio) Remove construction debris from yard & patio Provide step at patio slab 14" to 24" to grade Provide 6" clearance finished grade to wood siding Exterior drain tiles shall discharge 36" from foundation Repair broken PVC @ sump discharge
Occupancy Inspection - Codes Residential Failed 11/16/2021 11/16/2021 11/16/2021
Misc
Corrective Action Required
11/11/2021
PROVIDE ACCESS TO BACK YARD FOR INSPECTION -Sidewalk inspection pending -Address 6x6 cedar post covered deck not continuous per plan -Obtain lawn irrigation permit & submit back flow certification } -Exterior drain tiles shall discharge 36" from foundation Repair broken and extend PVC @ sump discharge
Occupancy Inspection - Codes Residential Failed 11/24/2021 11/24/2021 11/24/2021
Misc
Corrective Action Required
11/16/2021
-Sidewalk inspection pending submit back flow certification
Sidewalk Inspection Passed 11/29/2021 11/29/2021
Misc
Corrective Action Required
10/07/2021
Forms were placed and aggregate was present and compacted. Water meter is located in the middle of the forms. Plumber needs to dig it back up and relocate it outside of the sidewalk. I talked with Mark Harding about the water meter and passed the info on to Jared from Summit Homes. RP 8-3-21
Misc
Corrective Action Required
10/07/2021
Forms were placed and aggregate was present and compacted. Water meter was moved out of the sidewalk but will need to be raised. RP 8-12-21
Misc
Corrective Action Required
10/07/2021
Sidewalk has different spacing for all 4 panels. Also has indentations and rough finish. Need to remove and replace. RP 8-23-21
Misc
Corrective Action Required
10/07/2021
Spoke Jarod at Summit Homes and let him know that all 4 panels need to be ripped out and replaced.
Misc
Informational
11/29/2021
Damaged panels have been replaced. Sidewalk meets LS and ADA specs. RP 11-29-21
Occupancy Inspection - Codes Residential Full C of O 12/3/2021 12/3/2021 12/03/2021
Misc
Resolved
12/03/2021
Documents & Images
Date Uploaded File Type Document Name
02/22/2021 Application Form APPLICATION
02/22/2021 51 WOODSIDE RIDGE ROOF LAYOUT
02/22/2021 W2 #51 - Charlotte - Tuscan - Sheets- signed
02/22/2021 2646690 RF SEALS 02162021
02/22/2021 LOT 51 FINAL
02/22/2021 Letter Codes Residential Plan Review
02/22/2021 Approved Plans APPROVED TRUSS DRAWINGS
02/22/2021 Approved Plans APPROVED TRUSS LAYOUT
02/23/2021 Plot Plan APPROVED PLOT PLAN
02/23/2021 Approved Plans APPROVED PLANS
02/23/2021 Receipt Receipt for transaction:2021-000861
02/24/2021 Letter DS Building Permit
03/26/2021 Letter INSPECTION SUMMARY
04/20/2021 Letter INSPECTION SUMMARY
06/17/2021 Letter INSPECTION SUMMARY
06/17/2021 Letter INSPECTION SUMMARY
06/21/2021 Letter INSPECTION SUMMARY
06/21/2021 Letter INSPECTION SUMMARY
06/25/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
07/14/2021 Letter INSPECTION SUMMARY
07/26/2021 Letter INSPECTION SUMMARY
07/30/2021 Letter INSPECTION SUMMARY
08/03/2021 Letter INSPECTION SUMMARY
08/06/2021 Letter INSPECTION SUMMARY
08/12/2021 Letter INSPECTION SUMMARY
08/23/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
09/15/2021 Letter Codes Temporary Certificate of Occupancy
09/15/2021 Letter INSPECTION SUMMARY
09/23/2021 51 Woodside Ridge Retaining Wall Letter - FINAL - Signed
09/24/2021 51 Woodside Ridge Retaining Wall Letter - FINAL - Signed
09/24/2021 51 Woodside Ridge Retaining Wall Letter - FINAL - Signed
10/07/2021 Letter INSPECTION SUMMARY
11/11/2021 Letter INSPECTION SUMMARY
11/16/2021 Letter INSPECTION SUMMARY
11/22/2021 51 Woodside Ridge Non-continuous deck post letter
11/24/2021 Letter INSPECTION SUMMARY
11/29/2021 Letter INSPECTION SUMMARY
12/03/2021 Letter Field Certificate of Occupancy
12/03/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home