PRRES20202014
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSS - UNFINISHED BASEMENT - COVERED DECK
07/21/2020
07/27/2020
05/14/2021
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
Reliable Mechanical Services, Inc. , Address:1025 W Couchman Dr.  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 07/23/2020 07/27/2020
Dylan Eppert
As-graded plot plan
Corrective Action Required
07/23/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Planning Review (RES) Approved 07/27/2020 07/23/2020
Jennifer Thompson
Residential Plan Review Approved 07/23/2020 07/23/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,356.07 $1,356.07 Paid 07/27/2020
8331507-Sewer Connection Fee $600.00 $600.00 Paid 07/27/2020
Water Tap Fee $3,581.00 $3,581.00 Paid 07/27/2020
Water Meter Fee $455.54 $455.54 Paid 07/27/2020
Right of Way Permit Fee $80.00 $80.00 Paid 07/27/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 07/27/2020
3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 05/12/2021
3rd and Subsequent Inspection Fee (Per Hour) $150.00 $150.00 Paid 05/12/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Piers/Caissons Inspection - Residential Passed 8/12/2020 8/12/2020 08/12/2020
Footing Inspection - Residential Passed 8/13/2020 8/13/2020 08/13/2020
Underslab Plumbing Inspection - Residential Passed 9/16/2020 9/16/2020 09/16/2020
Sewer Service Inspection - R Passed 12/1/2020 12/01/2020
Water Service Inspection - R Passed 12/2/2020 (11:30) 12/2/2020 12/02/2020
Erosion Control Inspection Residential Failed 12/04/2020
Misc
Corrective Action Required
12/04/2020
-Erosion control requires continuous maintenance. Repair/reestablish within two business days -Maintain gravel filter at Drive -Immediate Street clean up required -No further inspections until complete
All Rough Inspection - Residential Failed 12/4/2020 12/4/2020 12/04/2020
Misc
Corrective Action Required
12/04/2020
Inspection denied. Electrical contractors on site and not ready for inspection
Electrical Service Inspection Passed 12/7/2020 12/7/2020 12/07/2020
Gas Piping Inspection - Residential Passed 12/7/2020 12/7/2020 12/07/2020
Gas Service Inspection - Residential Passed 12/7/2020 12/7/2020 12/07/2020
All Rough Inspection - Residential Failed 12/7/2020 12/7/2020 12/07/2020
Misc
Corrective Action Required
12/07/2020
-Fireblock all tub and shower traps -protection plates at pex, top and bottom plates in pantry -Joist hanger to header at box out for chase in pantry, joist over 4’, interior side of chase non load bearing -1” clearace from combustibles required for b vent, pantry chase -Fireblock chases in living room, seal gaps in Fireblock -Seal unused top plates bores, 1st floor front bed -EC#2 per plans 1st floor -Nail H2.5 straps at covered deck to rim framing and not siding -Cannot verify all trusses and hangers at front porch -Hole bores through joist less than 2” from end of member for pex, E corner basement and NW corner basement (pex also crimped at bore) -Tighten all anchor bolts in basement -(2) 2x10 floor joists, E side basement per plans, (2) locations missing per plans -(2) 1 3/4” x 9 1/4” lvl headers at basement windows per plans -(3) 2x10 floor joist per plans, W side cantilever per plans -Attic access requires 30” clearance measured vertical from the ceiling framing -Nail sheathing per plans- 6” edge, 12” field -Bolt outer ply of rim to ledger at deck and add angel clip to inner ply -Provide (2) bolts per post/rim connection at deck
All Rough Inspection - Residential Failed 12/10/2020 12/10/2020 12/10/2020
Misc
Corrective Action Required
12/07/2020
-Seal unused top plates bores, 1st floor front bed -Cannot verify all trusses and hangers at front porch -Hole bores through joist less than 2” from end of member for pex, E corner basement and NW corner basement (pex also crimped at bore) -Attic access requires 30” clearance measured vertical from the ceiling framing -Nail sheathing per plans- 6” edge, 12” field -Bolt outer ply of rim to ledger at deck and add angel clip to inner ply -Provide (2) bolts per post/rim connection at deck
All Rough Inspection - Residential Failed 12/11/2020 12/11/2020 12/11/2020
Misc
Corrective Action Required
12/10/2020
-Hole bores through joist less than 2” from end of member for pex, E corner basement and NW corner basement (pex also crimped at bore -Bolt outer ply of rim to ledger at deck and add angel clip to inner ply -Provide (2) bolts per post/rim connection at deck
All Rough Inspection - Residential Failed 12/14/2020 12/14/2020 12/14/2020
Misc
Corrective Action Required
12/11/2020
-Hole bores through joist less than 2” from end of member for pex, NW corner basement (pex also crimped at bore) near sump pump
All Rough Inspection - Residential Passed 12/15/2020 12/15/2020 12/15/2020
Misc
Resolved
12/15/2020
-Hole bores through joist less than 2” from end of member for pex, NW corner basement (pex also crimped at bore) near sump pump
Occupancy Inspection - Codes Residential Failed 2/24/2021 2/24/2021 02/24/2021
Misc
Corrective Action Required
02/24/2021
-Final driveway inspection required, contact development services to schedule -As graded plot plan required prior to sodding, submit for review -Sod -Guardrail required at front porch, more than 30” from grade -Gutters and downspouts required -Splash blocks at all downspout and sump pump discharge locations, minimum 36” discharge from foundation -Seal all penetrations in siding, seal along top of meter can and AC disconnect
Driveway Inspection Passed 1/21/2021 03/03/2021
Misc
Informational
01/21/2021
On Thursday, 1-21-2021. I performed a drive approach inspection that passed city standards to pour concrete.
Occupancy Inspection - Codes Residential Failed 3/4/2021 3/4/2021 03/04/2021
Misc
Corrective Action Required
02/24/2021
-As graded plot plan required prior to sodding, submit for review -Sod -Guardrail required at front porch, more than 30” from grade -Splash blocks at all downspout and sump pump discharge locations, minimum 36” discharge from foundation
Occupancy Inspection - Codes Residential Failed 3/17/2021 3/17/2021 03/17/2021
Misc
Corrective Action Required
03/04/2021
INSPECTION DENIED -EROSION CONTROL SILT FENCE IS REQUIRED UNTIL SOD IS PLACED. RE ESTABLISH SILT FENCE BEFORE RESCHEDULING INSPECITON -As graded plot plan required prior to sodding, submit for review -Sod -Guardrail required at front porch, more than 30” from grade -Splash blocks at all downspout and sump pump discharge locations, minimum 36” discharge from foundation
Erosion Control Inspection Residential Failed 3/17/2021 3/17/2021 03/17/2021
Misc
Resolved
03/17/2021
-Erosion control requires continuous maintenance. Repair/reestablish within two business days -Maintain gravel filter at Drive -Immediate Street clean up required -No further inspections until complete
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/17/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -EROSION CONTROL SILT FENCE IS REQUIRED UNTIL SOD IS PLACED. RE ESTABLISH SILT FENCE BEFORE RESCHEDULING INSPECITON
Plot Plan Inspection Passed 3/31/2021 03/31/2021
Occupancy Inspection - Codes Residential Temporary C of O 4/2/2021 4/2/2021 04/02/2021
Misc
Corrective Action Required
03/17/2021
-Sod
Erosion Control Inspection Residential Passed 05/10/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/10/2021
Occupancy Inspection - Codes Residential Temporary C of O 5/10/2021 5/10/2021 05/10/2021
Misc
Corrective Action Required
04/02/2021
-ADD SPLASH BLOCK OR EXTENSION TO SUMP PUMP DISCHARGE, 36" DISCHARGE FROM FOUNDATION -RESOLVE ALL OUTSTANDING INSPECTION FEE(S) BEFORE FINAL C OF O **OK FOR TCO - TCO EXPIRES 5/24/21**
Occupancy Inspection - Codes Residential Full C of O 5/14/2021 5/14/2021 05/14/2021
Misc
Resolved
05/14/2021
Documents & Images
Date Uploaded File Type Document Name
07/21/2020 HT #43 - PERMIT APPLICATION
07/21/2020 LOT 43 FINAL
07/21/2020 400379
07/21/2020 HT #43 - TRUSS LAYOUT
07/21/2020 HT #43 - Canterbury - Modern Farm House - Sheets- signed
07/23/2020 Specifications APPROVED TRUSS PACKAGE
07/23/2020 Drawing approved truss layout
07/23/2020 Plans APPROVED HOUSE PLANS
07/23/2020 APPROVED ELEVATIONS
07/23/2020 Letter Codes Residential Plan Review
07/27/2020 Plot Plan APPROVED PLOT PLAN
07/27/2020 Receipt Receipt for transaction:2020-004718
07/27/2020 Letter DS Building Permit
08/12/2020 Lot 43 Hawthorne Ridge drilled pier corrected address
08/12/2020 Letter INSPECTION SUMMARY
08/13/2020 Lot 43 Hawthorne Ridge footing
08/13/2020 Letter INSPECTION SUMMARY
08/24/2020 Lot 43 Hawthorne Ridge Wall Inspection
09/16/2020 Letter INSPECTION SUMMARY
12/01/2020 Letter INSPECTION SUMMARY
12/02/2020 Letter INSPECTION SUMMARY
12/04/2020 Letter INSPECTION SUMMARY
12/04/2020 Letter INSPECTION SUMMARY
12/07/2020 Letter INSPECTION SUMMARY
12/07/2020 Letter INSPECTION SUMMARY
12/07/2020 Letter INSPECTION SUMMARY
12/07/2020 Letter INSPECTION SUMMARY
12/10/2020 Letter INSPECTION SUMMARY
12/11/2020 Letter INSPECTION SUMMARY
12/14/2020 Letter INSPECTION SUMMARY
12/15/2020 Letter INSPECTION SUMMARY
02/24/2021 Letter INSPECTION SUMMARY
03/04/2021 Letter INSPECTION SUMMARY
03/17/2021 Letter INSPECTION SUMMARY
03/17/2021 Letter INSPECTION SUMMARY
03/29/2021 LOT 43 ASBUILT
03/29/2021 Plot Plan approved as graded plot plan
03/31/2021 Letter INSPECTION SUMMARY
04/02/2021 Letter Codes Temporary Certificate of Occupancy
05/10/2021 Letter INSPECTION SUMMARY
05/10/2021 Letter Codes Temporary Certificate of Occupancy
05/12/2021 Receipt Receipt for transaction:2021-002894
05/14/2021 Letter Field Certificate of Occupancy
05/14/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home