Summary
PRRES20201458
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW SINGLE FAMILY UNFINISHED BASEMENT STOP WORK ORDER generated on 07/02/2020 12:00 AM by username 'Patrick Schonfeldt'. STOP WORK ORDER removed on 07/02/2020 12:00 AM by username 'Patrick Schonfeldt'.
06/03/2020
06/08/2020
04/07/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Not shown for privacy reasons.
Not shown for privacy reasons.
Not shown for privacy reasons.
Not shown for privacy reasons.
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/05/2020 06/05/2020
Steve Conrick
Residential Plan Review Approved 06/05/2020 06/05/2020
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,514.47 $1,514.47 Paid 06/08/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/08/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 06/08/2020
8331507-Sewer Connection Fee $600.00 $600.00 Paid 06/08/2020
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 06/08/2020
8350015-Water Meter Fee $425.02 $425.02 Paid 06/08/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/29/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/29/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed - Stop Work 07/02/2020
Misc
Corrective Action Required
07/02/2020
- Footing poured without inspection. If 3rd party inspection report must be submitted within 48 hours of inspection. Foundation walls have been poured and forms removed. Stop work order Issued
Footing Inspection - Residential Passed 07/02/2020
Misc
Corrective Action Required
07/02/2020
- Footing poured without inspection. If 3rd party inspection report must be submitted within 48 hours of inspection. Foundation walls have been poured and forms removed. Stop work order Issued
Underslab Plumbing Inspection - Residential Passed 9/23/2020 9/23/2020 09/23/2020
Erosion Control Inspection Residential Failed 10/12/2020
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/12/2020
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Sewer Service Inspection - R Passed 11/3/2020 (10:15) 11/3/2020 11/03/2020
Water Service Inspection - R Passed 11/4/2020 (9:00) 11/4/2020 11/04/2020
All Rough Inspection - Residential Not Ready 11/4/2020 11/4/2020 11/04/2020
Misc
Corrective Action Required
11/04/2020
INSPECTION DENIED - EROSION CONTROL REQUIRED AT FRONT OF LOT - CLEAN MUD AND GRAVEL IN STREET - CLEAN MUD AND GRAVEL FROM STORM INLET AT FRONT OF LOT
Erosion Control Inspection Residential Failed 11/4/2020 11/4/2020 11/04/2020
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/12/2020
- EROSION CONTROL REQUIRED AT FRONT OF LOT - CLEAN MUD AND GRAVEL IN STREET - CLEAN MUD AND GRAVEL FROM STORM INLET AT FRONT OF LOT
All Rough Inspection - Residential Not Ready 11/6/2020 11/6/2020 11/06/2020
Misc
Corrective Action Required
11/04/2020
INSPECTION DENIED - CLEAN EXTENSIVE MUD, DIRT, AND GRAVEL IN STREET - CLEAN MUD AND GRAVEL FROM STORM INLET AT FRONT OF LOT, MAINTAIN STORM INTLET PROTECTION
Erosion Control Inspection Residential Failed 11/6/2020 11/6/2020 11/06/2020
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
11/04/2020
- CLEAN EXTENSIVE MUD, DIRT, AND GRAVEL IN STREET - CLEAN MUD AND GRAVEL FROM STORM INLET AT FRONT OF LOT, MAINTAIN STORM INTLET PROTECTION
Electrical Service Inspection Passed 11/10/2020 11/10/2020 11/10/2020
Gas Piping Inspection - Residential Failed 11/10/2020 11/10/2020 11/10/2020
Misc
Corrective Action Required
11/10/2020
-Steel gas line to flex gas line coupling cannot be concealed at 1st floor bedroom closet wall -Gas pressure at 0 psi, must maintain 10 psi for 15 minutes
Gas Service Inspection - Residential Failed 11/10/2020 11/10/2020 11/10/2020
Misc
Corrective Action Required
11/10/2020
-Steel gas line to flex gas line coupling cannot be concealed at 1st floor bedroom closet wall -Gas pressure at 0 psi, must maintain 10 psi for 15 minutes
All Rough Inspection - Residential Failed 11/10/2020 11/10/2020 11/10/2020
Misc
Corrective Action Required
11/06/2020
-Garage anchor bolts in garage should be middle third of plate -Fireblock HVAC chase in garage -Fireblock above top plate garage -Joist hanger(s) above 1st floor bath, more than 4’ -Address over notch for DWV on floor joist above 1st floor bath -Structural straps at all exterior walls and interior load bearing walls top plates bored more than 50% -Nail dbl joists -Security blocking at backdoor, front door -Joist hangers above owner entry from garage, more than 4’ -Fireblock deadspace at refrigerator kitchen -Joist hangers at header in living room, more than 4’ -Stud to stud and abutting studs at intersecting wall corners (at braced wall panels) 12” oc nailing -EC#2 per plans -H2.5 straps at all hip trusses -(2) 2x10 joists from steel beam to bearing garage wall supported by (2) 2x4 per plans -Attach H2.5 straps to framing and not siding at covered patio -truss hangers per plans -Connect top plates at top stair landing at 2x6 to 2x4 wall -dbl truss girder supported at end by (2) studs, above front door N side -Support all DWV 48” oc, traps are not considered support -Complete DWV at laundry near HVAC chase -BOCCA protection plates at top and bottom plate laundry -Seal all top and bottom plate penetrations -Attic access 22” x 36” per plans -Fireblock deadspace at master bed entry -Truss bracing per plans -Joist hangers required at stair landing, over 4’ -Address cut floor joist above HVAC in basement -Steel gas line to flex gas line coupling cannot be concealed at 1st floor bedroom closet wall -Gas pressure at 0 psi, must maintain 10 psi for 15 minutes -Exterior sheathing to be fastened 6” oc edges & 12” field
All Rough Inspection - Residential Failed 11/17/2020 11/17/2020 11/17/2020
Misc
Corrective Action Required
11/10/2020
-Fireblock HVAC chase in garage -truss hangers per plans -Truss bracing per plans -Steel gas line to flex gas line coupling cannot be concealed at 1st floor bedroom closet wall OK TO INSULATE
All Rough Inspection - Residential Passed 11/19/2020 11/19/2020 11/19/2020
Misc
Resolved
11/19/2020
Gas Piping Inspection - Residential Passed 11/20/2020 11/20/2020 11/20/2020
Misc
Resolved
11/20/2020
Gas Service Inspection - Residential Failed 11/20/2020 11/20/2020 11/20/2020
Misc
Corrective Action Required
11/10/2020
- GAS PRESSURE AT 0 PSI, MUST MAINTAIN 10 PSI FOR 15 MINUTES
Gas Service Inspection - Residential Passed 12/4/2020 12/4/2020 12/04/2020
Misc
Resolved
12/04/2020
Driveway Inspection Partial 12/4/2020 (P.M.) 12/4/2020 12/04/2020
Misc
Informational
12/04/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 12/11/2020 12/11/2020 12/15/2020
Misc
Informational
12/04/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 1/29/2021 1/29/2021 01/29/2021
Misc
Corrective Action Required
01/29/2021
-Resolve outstanding inspection fee(s) before final c of o -Maintain erosion control on lot until sod is placed, address mud in street -Complete final grade and sod -splash blocks at all downspout and sump pump discharge locations, minimum 36” distance from foundation -Guardrail required at front porch, more than 30” from grade -R314.4 Interconnection required of all smoke detectors -Faceplate required on electrical receptacle in laundry
Erosion Control Inspection Residential Failed 01/29/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
11/06/2020
-Maintain erosion control on lot until sod is placed, address mud in street
Occupancy Inspection - Codes Residential Temporary C of O 2/3/2021 2/3/2021 02/03/2021
Misc
Corrective Action Required
01/29/2021
-Complete final grade and sod -splash blocks at all downspout and sump pump discharge locations, minimum 36” distance from foundation -Guardrail required at front porch, more than 30” from grade, R312.1.1 measured vertically to the floor or grade below at any point within 36 inches (914 mm) horizontally to the edge of the open side OK FOR TCO -TCO EXPIRES 2/24/21
Plot Plan Inspection Passed 04/07/2021
Occupancy Inspection - Codes Residential Full C of O 4/7/2021 4/7/2021 04/07/2021
Misc
Resolved
04/07/2021
Documents & Images
Date Uploaded File Type Document Name
06/03/2020 LOT 28 FINAL
06/03/2020 RT #28 - Bristol Ridge - French Country - Sheets- signed
06/03/2020 400281
06/03/2020 RT #28 - TRUSS LAYOUT
06/03/2020 RT #28 - PERMIT APP
06/03/2020 APPROVED RT #28 - TRUSS LAYOUT
06/03/2020 APPROVED 400281
06/05/2020 APPROVED RT #28 - Bristol Ridge - French Country - Sheets- signed
06/05/2020 APPROVED LOT 28 FINAL
06/08/2020 Receipt Receipt for transaction:2020-002744
06/08/2020 Letter DS Building Permit
07/02/2020 Letter Stop Work Order
07/02/2020 0813FD55-F0D8-4ED4-B474-9C79C4C5C249.jpeg
07/02/2020 EF61E8FD-A706-4E02-97C3-23B6AB9486DA.jpeg
07/02/2020 Engineer Report/Study Lot 28 Creekside at Raintree - Footing Inspection
07/02/2020 Engineer Report/Study Lot 28 Creekside at Raintree Soil Inspection
07/02/2020 Engineer Report/Study Lot 28 Creekside at Raintree Wall Inspection
07/02/2020 Letter INSPECTION SUMMARY
07/06/2020 Letter Lot 28 Creekside at Raintree - Footing Inspection
07/06/2020 Letter Lot 28 Creekside at Raintree Wall Inspection
07/06/2020 Letter Lot 28 Creekside at Raintree Soil Inspection
09/23/2020 Lot 28 Creekside at Raintree 2nd Footing Inspection
09/23/2020 Lot 28 Creekside at Raintree 2nd Wall Inspection
09/23/2020 Letter INSPECTION SUMMARY
10/12/2020 Letter INSPECTION SUMMARY
11/03/2020 Letter INSPECTION SUMMARY
11/04/2020 Letter INSPECTION SUMMARY
11/04/2020 Letter INSPECTION SUMMARY
11/04/2020 Letter INSPECTION SUMMARY
11/06/2020 Letter INSPECTION SUMMARY
11/06/2020 Letter INSPECTION SUMMARY
11/10/2020 Letter INSPECTION SUMMARY
11/10/2020 Letter INSPECTION SUMMARY
11/10/2020 Letter INSPECTION SUMMARY
11/10/2020 Letter INSPECTION SUMMARY
11/17/2020 Letter INSPECTION SUMMARY
11/19/2020 Letter INSPECTION SUMMARY
11/20/2020 Letter INSPECTION SUMMARY
11/20/2020 Letter INSPECTION SUMMARY
12/04/2020 Letter INSPECTION SUMMARY
12/04/2020 Letter INSPECTION SUMMARY
12/15/2020 Letter INSPECTION SUMMARY
01/29/2021 Letter INSPECTION SUMMARY
01/29/2021 Letter INSPECTION SUMMARY
01/29/2021 Receipt Receipt for transaction:2021-000470
02/03/2021 Letter INSPECTION SUMMARY
02/03/2021 Letter Codes Temporary Certificate of Occupancy
04/07/2021 Letter INSPECTION SUMMARY
04/07/2021 Letter Field Certificate of Occupancy
04/07/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home