Permit Application Status

PRRES20200322


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20200322
Building Permit - Residential
Certificate of Occupancy
WYSS HOME BUILDING LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED PATIO SUSPENDED STOOP
02/12/2020
02/18/2020
07/20/2021
Locations
Contacts
WYSS HOME BUILDING LLC, Address:PO BOX 6620, Phone:(816) 820-0142  
WYSS HOME BUILDING LLC, Address:PO BOX 6620, Phone:(816) 820-0142  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
ROBERTSON PLUMBING LLC, Address:PO BOX 165, Phone:(816) 781-9340  
MCRWYSS@HOTMAIL.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 02/14/2020 02/18/2020
Kim Brennan
Basement egress
Corrective Action Required
02/12/2020

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan. Please provide this information for both basement egress wells.
Misc
Corrective Action Required
02/12/2020

Please explain the note on the plot plan regarding the swale as the MDP does not show a swale.
Miscellaneous Correction
Corrective Action Required
02/12/2020

Please explain the french drain notes on the north side of the lot or why they are needed
Residential Plan Review Approved 02/14/2020 02/18/2020
Kim Brennan
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
02/12/2020

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) No square footage shown for unfinished basement
10 Combustion air
Corrective Action Required
02/12/2020

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,401.13 $1,401.13 Paid 02/18/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 02/18/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 02/18/2020
8331507-Sewer Connection Fee $510.00 $510.00 Paid 02/18/2020
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 02/18/2020
8350015-Water Meter Fee $425.02 $425.02 Paid 02/18/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/25/2020 3/25/2020 at 3:15 PM 03/25/2020
Foundation Inspection - Residential Passed 4/6/2020 (10:00) 4/6/2020 at 10:15 AM 04/06/2020
Sewer Service Inspection - R Passed 5/8/2020 (8:00) 5/8/2020 at 9:00 AM 05/08/2020
Water Service Inspection - R Passed 5/11/2020 (11:15) 5/11/2020 at 11:25 AM 05/11/2020
Erosion Control Inspection Residential Failed 5/13/2020 05/13/2020
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/13/2020
DEFICIENT EROSION CONTROL INSTALLATION. INSTALL EROSION CONTROL ALONG THE STREET NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Failed 5/13/2020 5/13/2020 at 8:30 AM 05/13/2020
Misc
Corrective Action Required
05/13/2020
-COMPLETE INSTALLING THE UNDERFLOOR DRAIN TILES
Underslab Plumbing Inspection - Residential Passed 5/15/2020 5/14/2020 05/14/2020
Misc
Resolved
05/14/2020
-COMPLETE INSTALLING THE UNDERFLOOR DRAIN TILES
Suspended Slab Inspection Passed 8/10/2020 (9:00) 8/10/2020 at 8:50 AM 08/10/2020
Gas Service Inspection - Residential Passed 10/29/2020 10/29/2020 10/29/2020
Electrical Service Inspection Failed 11/3/2020 11/3/2020 11/03/2020
Misc
Corrective Action Required
11/03/2020
-Tighten SE cable connector -Remove bonding screw from the grounded bus bar
All Rough Inspection - Residential Failed 11/3/2020 11/3/2020 11/03/2020
Misc
Corrective Action Required
11/03/2020
FRAMING: -Nail garage portal brace wall per code -Fb b-vent and shelf space from roof -Provide collar ties at upper ridge -Block both deck doors 3 stud spaces out at strike plate height -Fb floor opening at front bedroom closet wall -Have engineer address the followings: exterior brace wall width at wall opening to rear porch not per plan; tall 2x4 gable wall with non-continuous studs at front bedroom -Provide full support for lvl point load carrying the I beam load outside master bedroom. The small I beam below not catching the point load. -Hallway in basement shall be min 36” in width between finished wall -Fb basement wall per code vertically at max ten ft interval -Weld some of the un-attached steel columns to the I beam PLUMBING: -Provide min 4-10d nails at each side of the wall top plate straps -Secure gas csst line at fireplace ** OK TO INSULATE
All Rough Inspection - Residential Failed 11/12/2020 11/12/2020 11/12/2020
Misc
Corrective Action Required
11/03/2020
-Nail garage portal brace wall per code **The sheathing is not nailed to the lvl headers. The sheathing is broken right below the lvl -Provide bracing per engineer letter ** OK TO ROCK
Electrical Service Inspection Passed 11/12/2020 11/12/2020 11/12/2020
Misc
Resolved
11/12/2020
-Tighten SE cable connector -Remove bonding screw from the grounded bus bar
Driveway Inspection Partial 2/3/2021 (A.M.) 2/3/2021 02/03/2021
Misc
Informational
02/03/2021
Driveway - forms and materials passed pre-inspection.
Driveway Inspection Passed 2/9/2021 2/9/2021 02/23/2021
Misc
Informational
02/03/2021
Driveway - forms and materials passed pre-inspection.
Misc
Informational
02/23/2021
Driveway - passed final inspection.
Erosion Control Inspection Residential Passed 05/14/2021
DCM2 ESC DEFICIENT INSTALLATION
Resolved
05/14/2021
DEFICIENT EROSION CONTROL INSTALLATION. INSTALL EROSION CONTROL ALONG THE STREET NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Failed 5/14/2021 5/14/2021 05/14/2021
Misc
Corrective Action Required
05/14/2021
-All rough not approved. See the remaining deficiencies -Sidewalk not approved on record -Obtain lawn irrigation permit and submit the backflow test report to city -As-graded plot plan is required prior to sodding -Final grade, sod, downspout and sump pump extensions. Make sure to fix drainage issue at north side of house -Make sure that the sewer tracer wire and port are installed and available at grade level -Seal exterior wall penetrations, seal above AC disconnect, meter, seal above front hose bibb, etc -Fasten ladders to window wells -Lag deck ledger to rim band; install deck stair guardrail and handrail -Complete enclosure around master bathroom shower -Exterior doors not compliant with security code -Install handrail for garage stair -Complete water service connection; install pressure reducer; secure pex to wall -Install backflow preventer at basement hose bibb -Close off open 3” pvc at water service -Complete bathrooms
All Rough Inspection - Residential Passed 05/17/2021
Misc
Resolved
05/17/2021
-Nail garage portal brace wall per code **The sheathing is not nailed to the lvl headers. The sheathing is broken right below the lvl -Provide bracing per engineer letter ** OK TO ROCK
Occupancy Inspection - Codes Residential Temporary C of O 5/17/2021 5/17/2021 05/17/2021
Misc
Corrective Action Required
05/14/2021
-Sidewalk not approved on record -As-graded plot plan is required prior to sodding -Final grade, sod, downspout and sump pump extensions. Make sure to fix drainage issue at north side of house -Make sure that the sewer tracer wire and port are installed and available at grade level -Seal exterior wall penetrations, seal above AC disconnect, meter, seal above front hose bibb, etc -Complete enclosure around master bathroom shower -Secure pex to wall; install backflow preventer at basement hose bibb -Complete bathrooms
Occupancy Inspection - Codes Residential Temporary C of O 5/18/2021 05/18/2021
Misc
Corrective Action Required
05/17/2021
-Install permanent address -Sidewalk not approved on record -As-graded plot plan is required prior to sodding -Final grade, sod, downspout and sump pump extensions. Make sure to fix drainage issue at north side of house -Make sure that the sewer tracer wire and port are installed and available at grade level -Seal exterior wall penetrations, seal above AC disconnect, meter, seal above front hose bibb, etc
Sidewalk Inspection Passed 05/18/2021
Misc
Informational
05/18/2021
Sidewalk - was not ready during the original inspection. Sidewalk appears to pass require
Plot Plan Inspection Passed 7/20/2021 07/20/2021
Occupancy Inspection - Codes Residential Full C of O 7/20/2021 07/20/2021
Misc
Resolved
07/20/2021
-As-graded plot plan is required prior to sodding -Final grade, sod, downspout and sump pump extensions. Make sure to fix drainage issue at north side of house -Make sure that the sewer tracer wire and port are installed and available at grade level -Seal exterior wall penetrations, seal above AC disconnect, meter, seal above front hose bibb, etc
Documents & Images
Date Uploaded File Type Document Name
02/12/2020 Letter Codes Residential Plan Review
02/18/2020 Receipt Receipt for transaction: 2020-000669
02/18/2020 Letter DS Building Permit
02/20/2020 Plot Plan DOC022020-02202020091432
03/25/2020 Letter INSPECTION SUMMARY
04/06/2020 Letter INSPECTION SUMMARY
05/11/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
05/14/2020 Letter INSPECTION SUMMARY
08/10/2020 Letter INSPECTION SUMMARY
10/29/2020 Letter INSPECTION SUMMARY
11/03/2020 Letter INSPECTION SUMMARY
11/03/2020 Letter INSPECTION SUMMARY
11/12/2020 Engineer Report/Study DW Structural Inspection Letter Lot 322 Park Ridge 2029 NE Bluestone Dr
11/12/2020 Letter INSPECTION SUMMARY
11/12/2020 Letter INSPECTION SUMMARY
02/03/2021 Letter INSPECTION SUMMARY
02/23/2021 Letter INSPECTION SUMMARY
05/14/2021 Letter INSPECTION SUMMARY
05/14/2021 Letter INSPECTION SUMMARY
05/17/2021 Letter INSPECTION SUMMARY
05/17/2021 Letter INSPECTION SUMMARY
05/17/2021 Letter INSPECTION SUMMARY
05/17/2021 Letter Codes Temporary Certificate of Occupancy
05/18/2021 Letter Codes Temporary Certificate of Occupancy
05/18/2021 Letter INSPECTION SUMMARY
07/19/2021 Plot Plan Approved As Graded Plot Plan
07/20/2021 Letter Codes Final Certificate of Occupancy
07/20/2021 Letter Field Certificate of Occupancy
07/20/2021 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home