Permit Application Status

PRRES20200162


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20200162
Building Permit - Residential
Certificate of Occupancy
BERNIE F MCARDLE & SHANNON M MCARDLE
NEW SINGLE FAMILY
NEW SINGLE FAMILY PARTIALLY FINISHED BASEMENT COVERED DECK
01/23/2020
02/04/2020
07/21/2020
02/27/2024
Locations
Contacts
D AND D BUILDING INC, Address:PO BOX 7014, Phone:(816) 491-2125  
DANDDBUILDING@GMAIL.COM  
TEAGUE ELECTRIC CONSTRUCTION INC, Address:12425 W 92ND ST, Phone:(913) 529-4600  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
BERNIE F MCARDLE & SHANNON M MCARDLE, Address:1709 SW 27TH ST  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 01/27/2020 01/23/2020
Steve Conrick
Legal description
Corrective Action Required
01/23/2020

The legal description, including plat or phase number and lot number, and street address must be provided on the plot plan. Incorrect street address
Miscellaneous Correction
Corrective Action Required
01/23/2020

Pool will need to be approved through seperate permit. Remove from plot plan.
Residential Plan Review Approved 01/27/2020 01/23/2020
Steve Conrick
Plot Plan Review Rejected 01/27/2020 01/23/2020
Steve Conrick
Legal description
Corrective Action Required
01/23/2020

The legal description, including plat or phase number and lot number, and street address must be provided on the plot plan. Incorrect street address
Miscellaneous Correction
Corrective Action Required
01/23/2020

Pool will need to be approved through seperate permit. Remove from plot plan.
Residential Plan Review Approved 01/27/2020 01/23/2020
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,200.17 $1,200.17 Paid Not payable online 02/04/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid Not payable online 02/04/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid Not payable online 02/04/2020
8331507-Sewer Connection Fee $510.00 $510.00 Paid Not payable online 02/04/2020
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid Not payable online 02/04/2020
8350015-Water Meter Fee $425.02 $425.02 Paid Not payable online 02/04/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/14/2021
Outstanding Fees Amount Paid Owing Date Paid
9110080-Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid


$75.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/25/2020 (2:00) 2/25/2020 02/25/2020
Underslab Plumbing Inspection - Residential Passed 3/6/2020 3/6/2020 03/06/2020
Sewer Service Inspection - R Passed 3/23/2020 (1:00) 3/23/2020 03/23/2020
Water Service Inspection - R Passed 3/24/2020 3/24/2020 03/24/2020
Erosion Control Inspection Residential Failed 7/21/2020 07/21/2020
DCM2 ESC DEFICIENT INSTALLATION
Resolved
07/21/2020
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/21/2020
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
07/24/2020
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Piers/Caissons Inspection - Residential Passed 8/3/2020 (1:00) 8/3/2020 08/03/2020
Misc
Informational
08/03/2020
(2) 24 X 36 COVERED DECK PIERS
Miscellaneous Inspection Passed 8/7/2020 8/7/2020 08/07/2020
Misc
Informational
08/07/2020
-CHECK LOAD BEARING VALUE OF STUDS TO SUPPORT UPSTAIRS LOAD -PAN OFF/ SEAL DEAD SPACE
Electrical Service Inspection Failed 9/2/2020 9/2/2020 09/02/2020
Misc
Corrective Action Required
09/02/2020
-PROVIDE APPROVED, CITY STAMPED PLANS
Electrical Service Inspection Failed 9/2/2020 09/02/2020
Misc
Corrective Action Required
09/02/2020
-PROVIDE APPROVED, CITY STAMPED PLANS
Gas Service Inspection - Residential Failed 9/2/2020 9/2/2020 09/02/2020
Miscellaneous Correction
Corrective Action Required
09/02/2020
Gas Service Inspection - Residential Failed 9/2/2020 09/02/2020
Miscellaneous Correction
Corrective Action Required
09/02/2020
_PROVIDE APPROVED, CITY STAMPED PLANS
All Rough Inspection - Residential Failed 9/2/2020 9/2/2020 09/02/2020
Miscellaneous Correction
Corrective Action Required
09/02/2020
-PROVIDE APPROVED, CITY STAMPED PLANS
Electrical Service Inspection Passed 9/3/2020 09/03/2020
Misc
Resolved
09/03/2020
-PROVIDE APPROVED, CITY STAMPED PLANS
Gas Service Inspection - Residential Failed 9/3/2020 09/03/2020
Miscellaneous Correction
Corrective Action Required
09/02/2020
-NO PRESSURE ON GAUGE AT INSPECTION -BOND GAS LINE
All Rough Inspection - Residential Failed 9/3/2020 09/03/2020
Miscellaneous Correction
Corrective Action Required
09/02/2020
-ATTACH BEAM TO TOP OF COLUMNS IN GARAGE -MISSING 5/8” ANCHOR BOLTS AND WASHERS IN PORTAL FRAMING AT GARAGE -COMPLETE FRAMING OF NEW DOORWAY IN GARAGE -PROVIDE MIDPOINT STRAP ON ALL DWV 2” OR SMALLER PER CODE -PROTECTION PLATE DRYER VENT AT BOTTOM PLATE -PROVIDE HANGERS OR 1 1/2” BEARING FOR RAFTERS OVER ENTRY -PROVIDE HANGERS FOR JOISTS OVER ENTRY -SEAL PENETRATION IN WALL BY FIREPLACE -STRAP TOP PLATE AT EXTERIOR WALLS OF ENTRY/ GARAGE AND ENTRY/ BEDROOM -SEAL DEAD SPACE AT DOUBLE WALL AT STAIRS TO PREVENT VERTICAL TO HORIZONTAL FIRE SPREAD -PROVIDE DOUBLE BEARING STUD FOR BEAM BEHIND FIREPLACE -PROVIDE HANGER OR 1 1/2’” BEARING FOR STRUT SUPPORTING RIDGE LANDING ON FACE OF LVL IN GREAT ROOM -SEAL HOLE IN SUB FLOOR AT RANGE -SEAL PENETRATIONS IN TOP PLATE OF FUR OUT WALL BY PANELS -PROVIDE VERTICAL FIRESTOP IN BASEMENT BATH OFF OF STORAGE ROOM FUR OUT WALL WHERE GREATER THAT 10’ HORIZONTAL -ADDRESS MISSING STEEL COLUMNS PER PLANS THROUGHOUT -FIRESTOP DEAD SPACE IN BASEMENT FIREPLACE -COMPLETE 3” O.C. NAILING PATTERN OF EXTERIOR SHEATHING OF CF-PF WALL AT BREAKFAST AREA -ADDRESS MISSING DOUBLE LVLS AT HEADERS REQUIRED PER HEADER SCHEDULE -ADDRESS SINGLE LVL HEADERS USED IN PLACE OF DOUBLE 2X10 HEADERS REQUIRED PER HEADER SCHEDULE -ADDRESS ALL HEADERS TO BEAR ON MINIMUM OF (2) 2X4 PER FRAMING NOTES -BOND GAS LINE -NO PRESSURE ON GAS GAUGE AT TIME OF INSPECTION
Gas Service Inspection - Residential Failed 9/11/2020 9/11/2020 09/11/2020
Miscellaneous Correction
Corrective Action Required
09/03/2020
-NO PRESSURE ON GAUGE AT INSPECTION -BOND GAS LINE
Gas Service Inspection - Residential Failed 9/14/2020 9/14/2020 09/14/2020
Miscellaneous Correction
Corrective Action Required
09/11/2020
-NO PRESSURE ON GAUGE AT INSPECTION
All Rough Inspection - Residential Failed 9/14/2020 9/14/2020 09/14/2020
Miscellaneous Correction
Corrective Action Required
09/03/2020
-ATTACH BEAM TO TOP OF COLUMNS IN GARAGE -COMPLETE FRAMING OF NEW DOORWAY IN GARAGE- MINIMUM OF (2) 2X4 BEARING STUDS REQUIRED PER PLANS -PROVIDE HANGERS OR 1 1/2” BEARING FOR RAFTERS OVER ENTRY -PROVIDE HANGERS FOR JOISTS OVER ENTRY -SEAL DEAD SPACE AT DOUBLE WALL AT STAIRS TO PREVENT VERTICAL TO HORIZONTAL FIRE SPREAD- USE APPROVED MATERIALS PER R302.11.1 -PROVIDE HANGER OR 1 1/2’” BEARING FOR STRUT SUPPORTING RIDGE LANDING ON FACE OF LVL IN GREAT ROOM -PROVIDE VERTICAL FIRESTOP IN BASEMENT BATH OFF OF STORAGE ROOM FUR OUT WALL WHERE GREATER THAN 10’ HORIZONTAL -ADDRESS MISSING STEEL COLUMNS PER PLANS THROUGHOUT AND IN ACCORDANCE WITH SUBMITTED ENGINEERED LETTER -FIRESTOP DEAD SPACE IN BASEMENT FIREPLACE- USE APPROVED MATERIALS PER R302.11. FIREBLOCKING REQUIRED BETWEEN FLOORS AND JOST SPACES PER R1003.19- -ADDRESS MISSING DOUBLE LVLS AT HEADERS REQUIRED PER HEADER SCHEDULE -ADDRESS SINGLE LVL HEADERS USED IN PLACE OF DOUBLE 2X10 HEADERS REQUIRED PER HEADER SCHEDULE -ADDRESS ALL HEADERS TO BEAR ON MINIMUM OF (2) 2X4 PER FRAMING NOTES -NO PRESSURE ON GAS GAUGE AT TIME OF INSPECTION
Gas Service Inspection - Residential Passed 9/16/2020 9/16/2020 09/16/2020
Miscellaneous Correction
Resolved
09/16/2020
-NO PRESSURE ON GAUGE AT INSPECTION
All Rough Inspection - Residential Failed 9/16/2020 9/16/2020 09/16/2020
Miscellaneous Correction
Corrective Action Required
09/14/2020
-PROVIDE ADEQUATE EROSION CONTROL AND CLEAN UP TRASH AND DEBRIS FROM STREETS BEFORE FURTHER SIGNS INSPECTION - MINIMUM OF (2) 2X4 BEARING STUDS REQUIRED PER PLANS -PROVIDE HANGERS OR 1 1/2” BEARING FOR RAFTERS OVER ENTRY -PROVIDE HANGERS FOR JOISTS OVER ENTRY -SEAL DEAD SPACE AT DOUBLE WALL AT STAIRS TO PREVENT VERTICAL TO HORIZONTAL FIRE SPREAD- USE APPROVED MATERIALS PER R302.11.1 -PROVIDE HANGER OR 1 1/2’” BEARING FOR STRUT SUPPORTING RIDGE LANDING ON FACE OF LVL IN GREAT ROOM -PROVIDE VERTICAL FIRESTOP IN BASEMENT BATH OFF OF STORAGE ROOM FUR OUT WALL WHERE GREATER THAN 10’ HORIZONTAL -FIRESTOP DEAD SPACE IN BASEMENT FIREPLACE- USE APPROVED MATERIALS PER R302.11. FIREBLOCKING REQUIRED BETWEEN FLOORS AND JOST SPACES PER R1003.19- -ADDRESS MISSING DOUBLE LVLS AT HEADERS REQUIRED PER HEADER SCHEDULE -ADDRESS SINGLE LVL HEADERS USED IN PLACE OF DOUBLE 2X10 HEADERS REQUIRED PER HEADER SCHEDULE -ADDRESS ALL HEADERS TO BEAR ON MINIMUM OF (2) 2X4 PER FRAMING NOTES
Erosion Control Inspection Residential Failed 9/16/2020 09/16/2020
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/21/2020
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/16/2020
-EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -CLEAN SITE AND STREETS OF DEBRIS -PROVIDE ADEQUATE EROSION CONTROL AT PERIMETER OF LOT AND MAINTAIN GRAVEL FILTER
All Rough Inspection - Residential Not Ready 9/21/2020 9/21/2020 09/21/2020
Miscellaneous Correction
Corrective Action Required
09/16/2020
-PROVIDE ADEQUATE EROSION CONTROL AND CLEAN UP TRASH AND DEBRIS FROM STREETS BEFORE FURTHER INSPECTION - MINIMUM OF (2) 2X4 BEARING STUDS REQUIRED PER PLANS -PROVIDE HANGERS OR 1 1/2” BEARING FOR RAFTERS OVER ENTRY -PROVIDE HANGERS FOR JOISTS OVER ENTRY -SEAL DEAD SPACE AT DOUBLE WALL AT STAIRS TO PREVENT VERTICAL TO HORIZONTAL FIRE SPREAD- USE APPROVED MATERIALS PER R302.11.1 -PROVIDE HANGER OR 1 1/2’” BEARING FOR STRUT SUPPORTING RIDGE LANDING ON FACE OF LVL IN GREAT ROOM -PROVIDE VERTICAL FIRESTOP IN BASEMENT BATH OFF OF STORAGE ROOM FUR OUT WALL WHERE GREATER THAN 10’ HORIZONTAL -FIRESTOP DEAD SPACE IN BASEMENT FIREPLACE- USE APPROVED MATERIALS PER R302.11. FIREBLOCKING REQUIRED BETWEEN FLOORS AND JOST SPACES PER R1003.19- -ADDRESS MISSING DOUBLE LVLS AT HEADERS REQUIRED PER HEADER SCHEDULE -ADDRESS SINGLE LVL HEADERS USED IN PLACE OF DOUBLE 2X10 HEADERS REQUIRED PER HEADER SCHEDULE -ADDRESS ALL HEADERS TO BEAR ON MINIMUM OF (2) 2X4 PER FRAMING NOTES
Misc
Corrective Action Required
09/21/2020
9/21/20- Inspection denied due to lack of compliance with site inspection on 9/16/20
Gas Service Inspection - Residential Failed 9/21/2020 9/21/2020 09/21/2020
Misc
Corrective Action Required
09/21/2020
Inspection denied due to lack of compliance of site inspection on 9/16/20
All Rough Inspection - Residential Failed 9/24/2020 9/24/2020 09/24/2020
Miscellaneous Correction
Corrective Action Required
09/21/2020
-PROVIDE ADEQUATE EROSION CONTROL AND CLEAN UP TRASH AND DEBRIS FROM STREETS BEFORE FURTHER INSPECTION - MINIMUM OF (2) 2X4 BEARING STUDS REQUIRED PER PLANS -PROVIDE HANGERS OR 1 1/2” BEARING FOR RAFTERS OVER ENTRY -PROVIDE HANGERS FOR JOISTS OVER ENTRY -SEAL DEAD SPACE AT DOUBLE WALL AT STAIRS TO PREVENT VERTICAL TO HORIZONTAL FIRE SPREAD- USE APPROVED MATERIALS PER R302.11.1 -PROVIDE HANGER OR 1 1/2’” BEARING FOR STRUT SUPPORTING RIDGE LANDING ON FACE OF LVL IN GREAT ROOM -PROVIDE VERTICAL FIRESTOP IN BASEMENT BATH OFF OF STORAGE ROOM FUR OUT WALL WHERE GREATER THAN 10’ HORIZONTAL -FIRESTOP DEAD SPACE IN BASEMENT FIREPLACE- USE APPROVED MATERIALS PER R302.11. FIREBLOCKING REQUIRED BETWEEN FLOORS AND JOST SPACES PER R1003.19- -ADDRESS MISSING DOUBLE LVLS AT HEADERS REQUIRED PER HEADER SCHEDULE -ADDRESS SINGLE LVL HEADERS USED IN PLACE OF DOUBLE 2X10 HEADERS REQUIRED PER HEADER SCHEDULE -ADDRESS ALL HEADERS TO BEAR ON MINIMUM OF (2) 2X4 PER FRAMING NOTES
Misc
Corrective Action Required
09/21/2020
9/21/20- Inspection denied due to lack of compliance with site inspection on 9/16/20 9/24/20- Inspection denied. Immediate cleanup of street required and city approved plans required to be on site for all inspections
All Rough Inspection - Residential Passed 9/29/2020 9/29/2020 09/29/2020
Miscellaneous Correction
Resolved
09/29/2020
-PROVIDE ADEQUATE EROSION CONTROL AND CLEAN UP TRASH AND DEBRIS FROM STREETS BEFORE FURTHER INSPECTION - MINIMUM OF (2) 2X4 BEARING STUDS REQUIRED PER PLANS -PROVIDE HANGERS OR 1 1/2” BEARING FOR RAFTERS OVER ENTRY -PROVIDE HANGERS FOR JOISTS OVER ENTRY -SEAL DEAD SPACE AT DOUBLE WALL AT STAIRS TO PREVENT VERTICAL TO HORIZONTAL FIRE SPREAD- USE APPROVED MATERIALS PER R302.11.1 -PROVIDE HANGER OR 1 1/2’” BEARING FOR STRUT SUPPORTING RIDGE LANDING ON FACE OF LVL IN GREAT ROOM -PROVIDE VERTICAL FIRESTOP IN BASEMENT BATH OFF OF STORAGE ROOM FUR OUT WALL WHERE GREATER THAN 10’ HORIZONTAL -FIRESTOP DEAD SPACE IN BASEMENT FIREPLACE- USE APPROVED MATERIALS PER R302.11. FIREBLOCKING REQUIRED BETWEEN FLOORS AND JOST SPACES PER R1003.19- -ADDRESS MISSING DOUBLE LVLS AT HEADERS REQUIRED PER HEADER SCHEDULE -ADDRESS SINGLE LVL HEADERS USED IN PLACE OF DOUBLE 2X10 HEADERS REQUIRED PER HEADER SCHEDULE -ADDRESS ALL HEADERS TO BEAR ON MINIMUM OF (2) 2X4 PER FRAMING NOTES
Misc
Partial Correction
09/29/2020
erosion control installed on east side of structure shall be installed to the furthest point of land disturbance. Compliance required within 2 days.
Gas Service Inspection - Residential Failed 9/29/2020 9/29/2020 09/29/2020
Misc
Corrective Action Required
09/21/2020
-Minimum 10 psi for 15 minutes required for gas piping pressure test -Complete appliance exhaust piping
Occupancy Inspection - Codes Residential Failed 1/12/2021 1/12/2021 01/12/2021
Miscellaneous Correction
Corrective Action Required
01/12/2021
-All fees must be paid in full -Only partial approval sidewalk and driveway, contact development services to resolve this issue -Provide gutters and downspouts -Downspouts and sump piping to discharge minimum 36 inches from foundation -Complete sod installation -Remove trash and construction debris from site -Remove trash and debris from stormwater box inlet -Remove debris from Street -Complete exterior façade -Irrigation permit required -Complete HVAC installation -Identify white insulated Conductors to be used as current carrying Conductors at both points of termination, condensing unit circuits -Exterior receptacles exposed to the elements require in use covers -complete electrical installation, NM conductors prohibited to be exposed outdoors or in exterior raceways. Conductors must be wet location rated, deck area -complete low voltage installation -provide proper bearing of deck joists at ledger connections -Retaining walls exceeding 4’ in height measured from the bottom of the footing to the top of the wall require professional design -Handrail required at front stoop -Provide secondary locking device at sliding glass door -All exterior receptacles require GFCI protection, deck -Receptacles in laundry area require GFCI protection -Label single receptacle dedicated circuits in unfinished areas as non-GFCI protected -Complete plumbing installation of all fixtures, basement bathrooms -Provide return air path from basement bedroom -Complete installation of safety glazed shower doors -Receptacles in unfinished area require GFCI protection, electrical panel room -Branch circuits that supply 120-volt, single-phase, 15- and 20- ampere outlets installed in kitchens, family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sun- rooms, recreations rooms, closets, hallways, laundry areas and similar rooms or areas shall be AFCI protected -GFCI protection of dishwasher circuit required -Provide breaker lockout device for hardwired appliances not in sight of panel
Sidewalk Inspection Passed 10/8/2020 (P.M.) 10/8/2020 01/14/2021
Misc
Informational
01/14/2021
On Thursday, 1-14-2021. A sidewalk inspection was completed and passed city specifications.
Driveway Inspection Passed 10/8/2020 (P.M.) 10/8/2020 01/19/2021
Misc
Informational
01/14/2021
On. Thursday, 1-14-2021. A driveway inspection was completed an passed city standards.
Occupancy Inspection - Codes Residential Temporary C of O 1/19/2021 1/19/2021 01/19/2021
Miscellaneous Correction
Corrective Action Required
01/12/2021
-Complete sod installation -Complete HVAC installation, exterior equipment -provide proper bearing of deck joists at ledger connections -Permanent handrail required at front stoop TCO VALID THROUGH 02/19/21
Occupancy Inspection - Codes Residential Temporary C of O 2/22/2021 02/22/2021
Miscellaneous Correction
Corrective Action Required
01/19/2021
-Complete sod installation -Complete HVAC installation, exterior equipment -provide proper bearing of deck joists at ledger connections -Permanent handrail required at front stoop TCO EXTENSION VALID THROUGH 03/19/21 DUE TO WEATHER CONDITIONS
Miscellaneous Inspection Partial 3/19/2021 03/18/2021
Misc
Informational
03/18/2021
Partial pool bonding approval, from pool equipment pad location to southwest corner of house
Erosion Control Inspection Residential Passed 05/18/2021
DCM3 ESC REQUIRED 2 DAY
Resolved
05/18/2021
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/18/2021
-EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -CLEAN SITE AND STREETS OF DEBRIS -PROVIDE ADEQUATE EROSION CONTROL AT PERIMETER OF LOT AND MAINTAIN GRAVEL FILTER
Occupancy Inspection - Codes Residential Failed 05/18/2021
Miscellaneous Correction
Corrective Action Required
02/22/2021
-Complete sod installation -Complete HVAC installation, exterior equipment -provide proper bearing of deck joists at ledger connections -Permanent handrail required at front stoop TCO EXTENSION VALID THROUGH 03/19/21 DUE TO WEATHER CONDITIONS
Miscellaneous Correction
Corrective Action Required
05/18/2021
The temporary certificate of occupancy has expired at this address. If remaining correction items are complete please schedule an occupancy inspection. If remaining correction items are not complete a permit extension request must be submitted in writing with the expected date of completion.
Sidewalk Inspection Partial 5/27/2022 5/27/2022 05/27/2022
Misc
Informational
05/27/2022
On 5.27.2022 I performed a sidewalk inspection for a single sidewalk 4x4 of sidewalk was installed to complete the construction to the property line. I passed the inspection to pour concrete.
Plot Plan Inspection Passed 8/4/2022 08/04/2022
Occupancy Inspection - Codes Residential Failed 8/4/2022 08/04/2022
Miscellaneous Correction
Resolved
08/04/2022
-Complete sod installation -Complete HVAC installation, exterior equipment -provide proper bearing of deck joists at ledger connections -Permanent handrail required at front stoop TCO EXTENSION VALID THROUGH 03/19/21 DUE TO WEATHER CONDITIONS
Miscellaneous Correction
Resolved
08/04/2022
The temporary certificate of occupancy has expired at this address. If remaining correction items are complete please schedule an occupancy inspection. If remaining correction items are not complete a permit extension request must be submitted in writing with the expected date of completion.
Misc
Corrective Action Required
08/04/2022
address pending sidewalk inspection
Sidewalk Inspection Passed 8/5/2022 8/5/2022 08/05/2022
Misc
Informational
05/27/2022
On 5.27.2022 I performed a sidewalk inspection for a single sidewalk 4x4 of sidewalk was installed to complete the construction to the property line. I passed the inspection to pour concrete. 8-5-22 RH. Sidewalk meets LS and ADA Specification.
Documents & Images
Date Uploaded File Type Document Name
01/23/2020 Letter Codes Residential Plan Review
02/04/2020 Receipt Receipt for transaction: 2020-000439
02/04/2020 Letter DS Building Permit
02/11/2020 Plot Plan DOC021020-02102020104033
02/25/2020 Letter INSPECTION SUMMARY
03/06/2020 Letter INSPECTION SUMMARY
03/23/2020 Letter INSPECTION SUMMARY
03/24/2020 Letter INSPECTION SUMMARY
07/21/2020 Letter INSPECTION SUMMARY
07/24/2020 Letter INSPECTION SUMMARY
08/03/2020 Letter INSPECTION SUMMARY
08/07/2020 Letter INSPECTION SUMMARY
09/02/2020 Letter INSPECTION SUMMARY
09/02/2020 Letter INSPECTION SUMMARY
09/03/2020 Letter INSPECTION SUMMARY
09/03/2020 Letter INSPECTION SUMMARY
09/03/2020 Letter INSPECTION SUMMARY
09/03/2020 Letter INSPECTION SUMMARY
09/03/2020 Letter INSPECTION SUMMARY
09/03/2020 Letter INSPECTION SUMMARY
09/03/2020 Letter INSPECTION SUMMARY
09/10/2020 2020_09_04_1709 SW 27th St_DD_Report_Sealed
09/11/2020 Letter INSPECTION SUMMARY
09/14/2020 Letter INSPECTION SUMMARY
09/14/2020 Letter INSPECTION SUMMARY
09/16/2020 Letter INSPECTION SUMMARY
09/16/2020 Letter INSPECTION SUMMARY
09/16/2020 Letter INSPECTION SUMMARY
09/21/2020 Letter INSPECTION SUMMARY
09/21/2020 Letter INSPECTION SUMMARY
09/24/2020 Letter INSPECTION SUMMARY
09/29/2020 Letter INSPECTION SUMMARY
09/29/2020 Letter INSPECTION SUMMARY
01/12/2021 Letter INSPECTION SUMMARY
01/14/2021 Receipt Receipt for transaction:2021-000228
01/19/2021 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/19/2021 Letter Codes Temporary Certificate of Occupancy
01/19/2021 Letter INSPECTION SUMMARY
02/02/2021 Engineer Report/Study Deck engineer report
02/22/2021 Letter Codes Temporary Certificate of Occupancy
03/18/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
05/27/2022 Letter INSPECTION SUMMARY
08/04/2022 Letter INSPECTION SUMMARY
08/04/2022 Letter INSPECTION SUMMARY
08/05/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home