Permit Application Status

PRRES20193668


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20193668
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW SINGLE FAMILY
12/23/2019
01/10/2020
06/24/2020
08/30/2021
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
ASHLEY@NEWMARKHOMESKC.COM  
CLASS ONE ELECTRIC INC, Address:PO BOX 24343, Phone:(913) 915-1767  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 01/14/2020 01/10/2020
Development Center
Lot elevations
Corrective Action Required
01/10/2020

Existing and finish elevations at all property corners must be provided on the plot plan. Just want to confirm that the ne property corner is being raised. if this brings the lot out of the flood plain we will need a loma
Basement opening elevations
Corrective Action Required
01/10/2020

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. Correct MBOE
100-year floodplain
Corrective Action Required
01/10/2020

100-year floodplain, where applicable, must be shown on the plot plan. (Foundation elevation certificate required prior to occupancy)
As-graded plot plan
Corrective Action Required
01/10/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. add note "AS GRADED PLOT PLAN IS REQUIRED PRIOR TO SODDING."
Residential Plan Review Approved 01/14/2020 01/10/2020
Development Center
03 Two (2) plot plans
Corrective Action Required
01/10/2020

Two (2) plot plans Print to scale (2)
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
01/10/2020

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315)
Plot Plan Review Rejected 12/27/2019 12/27/2019
Steve Conrick
Lot elevations
Corrective Action Required
12/27/2019

Existing and finish elevations at all property corners must be provided on the plot plan. Just want to confirm that the ne property corner is being raised. if this brings the lot out of the flood plain we will need a loma
Basement opening elevations
Corrective Action Required
12/27/2019

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. Correct MBOE
100-year floodplain
Corrective Action Required
12/27/2019

100-year floodplain, where applicable, must be shown on the plot plan. (Foundation elevation certificate required prior to occupancy)
As-graded plot plan
Corrective Action Required
12/27/2019

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. add note "AS GRADED PLOT PLAN IS REQUIRED PRIOR TO SODDING."
Residential Plan Review Rejected 12/27/2019 12/27/2019
Steve Conrick
03 Two (2) plot plans
Corrective Action Required
12/27/2019

Two (2) plot plans Print to scale (2)
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
12/27/2019

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315)
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,351.45 $1,351.45 Paid 01/10/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 01/10/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 01/10/2020
8331507-Sewer Connection Fee $540.00 $540.00 Paid 01/10/2020
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 01/10/2020
8350015-Water Meter Fee $425.02 $425.02 Paid 01/10/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 2/11/2020 (2:30) 2/11/2020 02/11/2020
Misc
Corrective Action Required
02/11/2020
Post address on job site - Provide erosion control - Provide engineer report & 3rd party inspection for drilled piers -
Piers/Caissons Inspection - Residential Passed 2/14/2020 02/14/2020
Footing Inspection - Residential Passed 2/14/2020 02/14/2020
Misc
Corrective Action Required
02/11/2020
Post address on job site - Provide erosion control - Provide engineer report & 3rd party inspection for drilled piers -
Underslab Plumbing Inspection - Residential Failed 4/14/2020 4/14/2020 at 7:25 AM 04/14/2020
PLUMBING
Corrective Action Required
04/14/2020
- BASEMENT WATER COVERED PUMP OUT RECALL WHEN READY -
Sewer Service Inspection - R Passed 4/30/2020 (1:30) 4/30/2020 04/30/2020
Underslab Plumbing Inspection - Residential Passed 5/6/2020 5/6/2020 05/06/2020
PLUMBING
Resolved
05/06/2020
Water Service Inspection - R Passed 5/8/2020 5/8/2020 at 1:16 PM 05/08/2020
Electrical Service Inspection Passed 9/8/2020 9/8/2020 09/08/2020
Gas Piping Inspection - Residential Passed 9/8/2020 9/8/2020 09/08/2020
All Rough Inspection - Residential Failed 9/8/2020 9/8/2020 09/08/2020
Miscellaneous Correction
Corrective Action Required
09/08/2020
-POST ADDRESS -PFG NOT COMPLETE- MISSING DOUBLE BOTTOM PLATE, TENSION STRAPS AND NUTS ON ANCHOR BOLTS -TIGHTEN ANCHOR BOLTS IN GARAGE -ADDRESS OVER-NOTCHED STUDS IN GARAGE -ADD ANCHOR BOLT IN PLATE WHERE BOLTS GREATER THAN 6’ OC -ADD ANCHOR BOLT IN PLATE BREAK WITHIN 12” -FIRE BLOCK DUCT CHASE IN GARAGE -STRAP ALL VERTICAL DWV 2” AND SMALLER AT MIDPOINT PER CODE -FIREBLOCK DEAD SPACE IN KITCHEN -PROTECT DWV AT BOTTOM PLATE BY FRONT DOOR -PROVIDE SECURITY BLOCKS AT BACK DOOR -FIRE BLOCK DEAD SPACE AT DUCT CHASE IN BED 2 -MISSING TRIPLE 2X8 BEAM ABOVE ENTRY -MISSING DOUBLE 2X4 BEARING STUDS IN BED 4 -MISSING TRIPLE 2X4 BEARING STUDS IN OWNER’S CLOSET WINDOW WALL -PROVIDE SOLID BLOCKING BETWEEN JOISTS UNDER ISLAND PER PLANS -INSULATE AND BLOCK CANTILEVER IN BASEMENT -COMPLETE PLUMBING -NAIL BOTTOM PLATES IN BASEMENT PER CODE -ADDRESS BEAM CONNECTIONS IN KITCHEN AND DINING THAT ARE WELDED INSTEAD OF BOLTED PER PLANS -NAIL EXTERIOR SHEATHING PER PLANS -PATCH HOLE IN SUBFLOOR IN MASTER BATH
Gas Service Inspection - Residential Passed 9/11/2020 9/11/2020 09/11/2020
All Rough Inspection - Residential Failed 9/11/2020 9/11/2020 09/11/2020
Miscellaneous Correction
Corrective Action Required
09/08/2020
**DO NOT INSULATE** -POST ADDRESS BEFORE NEXT INSPECTION -CORRECT OVER-NOTCHED STUD IN GARAGE -SEAL GAPS IN FIRE BLOCK AT DUCT CHASE IN GARAGE -PATCH HOLE IN SUB FLOOR BY ENTRY DOOR-NOT PRESENT ON PREVIOUS INSPECTION -SEAL GAPS IN FIRE BLOCK AT DEAD SPACE AT DUCT CHASE IN BED 2 -SEAL HOLES IN SUB FLOOR IN MASTER BATH NOT PRESENT DURING LAST INSPECTION -ADDRESS BEAM CONNECTIONS IN KITCHEN AND DINING THAT ARE WELDED INSTEAD OF BOLTED PER PLANS -COMPLETE PLUMBING IN MASTER BATH
Erosion Control Inspection Residential Failed 09/16/2020
Misc
Corrective Action Required
09/16/2020
-Deficient erosion control installation, shall be in compliance within two days. No further inspections until complete -Street cleanup required immediately. No further inspections until complete -Remove trash from site -Remove overgrown weeds and vegetation -Provide building address
All Rough Inspection - Residential Failed 9/17/2020 9/17/2020 09/17/2020
Miscellaneous Correction
Corrective Action Required
09/11/2020
-INSPECTION DENIED DUE TO LACK OF ADDRESS AND DEFICIENT EROSION CONTROL- **DO NOT INSULATE** -POST ADDRESS BEFORE NEXT INSPECTION -CORRECT OVER-NOTCHED STUD IN GARAGE -SEAL GAPS IN FIRE BLOCK AT DUCT CHASE IN GARAGE -PATCH HOLE IN SUB FLOOR BY ENTRY DOOR-NOT PRESENT ON PREVIOUS INSPECTION -SEAL GAPS IN FIRE BLOCK AT DEAD SPACE AT DUCT CHASE IN BED 2 -SEAL HOLES IN SUB FLOOR IN MASTER BATH NOT PRESENT DURING LAST INSPECTION -ADDRESS BEAM CONNECTIONS IN KITCHEN AND DINING THAT ARE WELDED INSTEAD OF BOLTED PER PLANS -COMPLETE PLUMBING IN MASTER BATH
Miscellaneous Correction
Corrective Action Required
09/17/2020
FROM FAILED EROSION CONTROL INSPECTION 9/16/20: -Deficient erosion control installation, shall be in compliance within two days. No further inspections until complete -Street cleanup required immediately. No further inspections until complete -Remove trash from site -Remove overgrown weeds and vegetation -Provide building address
All Rough Inspection - Residential Passed 9/21/2020 9/21/2020 09/21/2020
Miscellaneous Correction
Corrective Action Required
09/17/2020
Miscellaneous Correction
Resolved
09/21/2020
FROM FAILED EROSION CONTROL INSPECTION 9/16/20: -Deficient erosion control installation, shall be in compliance within two days. No further inspections until complete -Street cleanup required immediately. No further inspections until complete -Remove trash from site -Remove overgrown weeds and vegetation -Provide building address
Erosion Control Inspection Residential Passed 9/21/2020 9/21/2020 09/29/2020
Misc
Resolved
09/29/2020
-Deficient erosion control installation, shall be in compliance within two days. No further inspections until complete -Street cleanup required immediately. No further inspections until complete -Remove trash from site -Remove overgrown weeds and vegetation -Provide building address
Driveway Inspection Passed 12/1/2020 (P.M.) 12/1/2020 12/01/2020
Misc
Informational
12/01/2020
On Tuesday, 12-01-2020. I conducted a driveway inspection and passed the subgrade and forming to pour concrete.
Sidewalk Inspection Passed 12/1/2020 (P.M.) 12/1/2020 12/01/2020
Misc
Informational
12/01/2020
On Tuesday, 12-01-2020. I inspected 4” sidewalk sub grade and forms and found that it passed inspection to pour walk.
Erosion Control Inspection Residential Failed 01/07/2021
Misc
Corrective Action Required
09/21/2020
-Deficient erosion control installation, shall be in compliance within two days. No further inspections until complete -Street cleanup required immediately. No further inspections until complete -Remove trash from site -Remove overgrown weeds and vegetation -Provide building address
Misc
Informational
01/07/2021
1-7-21 3:48pm The silt fence is down on the north side of the site. This needs corrected ASAP. There is a creek on the same side.
Occupancy Inspection - Codes Residential Failed 2/8/2021 2/8/2021 02/08/2021
Misc
Corrective Action Required
02/08/2021
-Maintain erosion control methods until sod is in place -Provide foundation elevation certificate for review/approval -Provide final grade and an as graded plot plan for review/approval -Unable to locate water meter, ensure lid is accessible at grade and meter is 14-18 inches below lid -Provide sod -Complete building façade -Provide building address. Minimum 4 inch height, half inch stroke, on contrasting background and in illuminated area -Provide gutters and downspouts -Downspouts and sump piping to discharge minimum 36 inches from foundation -Seal top and sides of exterior lighting exposed to the elements -Remove trash and construction debris from site -Provide Basement egress window well ladder -Identify white insulated conductors to be used as current carrying conductors at both points of termination, AC circuit -Secure raceway within 12 inches of box, AC disconnect -complete interior guardrail installation -Complete safety glazed shower door installation -Install all outlet plate covers -Install weatherstripping at garage/dwelling separation door
Occupancy Inspection - Codes Residential Failed 2/11/2021 2/11/2021 02/11/2021
Misc
Corrective Action Required
02/08/2021
-Maintain erosion control methods until sod is in place -Provide foundation elevation certificate for review/approval, prior to occupancy -Provide final grade and an as graded plot plan for review/approval -Unable to locate water meter, ensure lid is accessible at grade and meter is 14-18 inches below lid -Provide sod -Complete building façade -Provide gutters and downspouts -Downspouts and sump piping to discharge minimum 36 inches from foundation -Seal top and sides of exterior lighting exposed to the elements
Plot Plan Inspection Passed 7/19/2021 07/19/2021
Occupancy Inspection - Codes Residential Full C of O 8/30/2021 8/30/2021 08/30/2021
Misc
Resolved
08/30/2021
Erosion Control Inspection Residential Passed 8/30/2021 8/30/2021 08/30/2021
Misc
Resolved
08/30/2021
Misc
Resolved
08/30/2021
Documents & Images
Date Uploaded File Type Document Name
12/27/2019 Letter Codes Residential Plan Review
01/10/2020 Receipt Receipt for transaction: 2020-000133
01/10/2020 Letter DS Building Permit
01/10/2020 Plot Plan DOC011020-003
02/11/2020 Letter INSPECTION SUMMARY
02/12/2020 Engineer Report/Study 1905 SW RIVER RUN DR_PIER PLAN_2-3-20
02/12/2020 Engineer Report/Study 1905 SW River Run Dr_PIER INSP_2020-02-10
02/13/2020 Engineer Report/Study 1905 SW River Run Dr_FTG INSP_2020-02-11
02/14/2020 Letter INSPECTION SUMMARY
02/14/2020 Letter INSPECTION SUMMARY
04/14/2020 Letter INSPECTION SUMMARY
04/30/2020 Letter INSPECTION SUMMARY
05/06/2020 Letter INSPECTION SUMMARY
05/08/2020 Letter INSPECTION SUMMARY
05/18/2020 1905 SW River Run Dr_BAS SLAB INSP_2020-05-08
09/08/2020 Letter INSPECTION SUMMARY
09/08/2020 Letter INSPECTION SUMMARY
09/08/2020 Letter INSPECTION SUMMARY
09/11/2020 Letter INSPECTION SUMMARY
09/11/2020 Letter INSPECTION SUMMARY
09/16/2020 Letter INSPECTION SUMMARY
09/17/2020 Letter INSPECTION SUMMARY
09/17/2020 2020_09_15_1905 SW River Run Drive_Weld Letter
09/21/2020 2020_09_15_1905 SW River Run Drive_Weld Letter (1)
09/21/2020 Letter INSPECTION SUMMARY
09/21/2020 Letter INSPECTION SUMMARY
09/29/2020 Letter INSPECTION SUMMARY
09/29/2020 Letter INSPECTION SUMMARY
01/07/2021 Letter INSPECTION SUMMARY
01/07/2021 Letter INSPECTION SUMMARY
01/07/2021 Letter INSPECTION SUMMARY
02/08/2021 Letter INSPECTION SUMMARY
02/11/2021 Letter INSPECTION SUMMARY
06/24/2021 signed copy as built grading lot 9
06/24/2021 Signed FEMA cert_ lot 9
07/16/2021 Plot Plan approved as graded plot plan
07/19/2021 Letter INSPECTION SUMMARY
08/30/2021 Letter Field Certificate of Occupancy
08/30/2021 Letter Codes Final Certificate of Occupancy
08/30/2021 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home