Summary
PRRES20191516
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK/UNCOVERED DECK
06/11/2019
06/13/2019
12/14/2020
Locations
Contacts
DAVE RICHARDS HOMEBUILDING INC, Address:605 SW US HIGHWAY 40 #414, Phone:(816) 365-8034  
BLUE VALLEY HEATING & COOLING LLC, Address:P O BOX 241, Phone:(816) 867-5122  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
DAVE@DAVERICHARDSHOMES.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/13/2019 06/12/2019
Steve Conrick
As-graded plot plan
Corrective Action Required
06/12/2019

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. *Add "AS-GRADED PLOT PLAN IS REQUIRED PRIOR TO SODDING." in a bubble.
Residential Plan Review Approved 06/13/2019 06/12/2019
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,012.80 $1,012.80 Paid 06/13/2019
Right of Way Permit Fee $80.00 $80.00 Paid 06/13/2019
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/13/2019
8331507-Sewer Connection Fee $420.00 $420.00 Paid 06/13/2019
Water Tap Fee $3,409.00 $3,409.00 Paid 06/13/2019
Water Meter Fee $408.37 $408.37 Paid 06/13/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 7/2/2019 (10:45) 7/2/2019 at 12:45 PM 07/02/2019
Water Service Inspection - R Partial 7/2/2019 07/02/2019
Underslab Plumbing Inspection - Residential Passed 7/18/2019 7/18/2019 at 9:50 AM 07/18/2019
Water Service Inspection - R Passed 7/24/2019 (2:15) 7/24/2019 at 2:15 PM 07/24/2019
All Rough Inspection - Residential Partial 8/9/2019 8/9/2019 at 8:50 AM 08/09/2019
Informational
08/09/2019
GARAGE PORTAL WALL FRAMING ONLY-OK
Erosion Control Inspection Residential Failed 8/28/2019 08/28/2019
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/28/2019
DEFICIENT EROSION CONTROL INSTALLATION. RESTORE EROSION CONTROL ALONG STREET NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Electrical Service Inspection Failed 8/28/2019 8/28/2019 08/28/2019
Misc
Corrective Action Required
08/28/2019
-BOND THE METAL FITTING BETWEEN THE METER AND SERVICE DISCONNECT WITH BONDING BUSHING, LOCKNUT, ETC. BONDING JUMPER SHALL BE THE SAME SIZE AT GROUNDING ELECTRODE CONDUCTOR -DRIVE THE GROUNDING ROD TO GROUND
Gas Service Inspection - Residential Passed 8/28/2019 8/28/2019 08/28/2019
All Rough Inspection - Residential Failed 8/28/2019 8/28/2019 at 8:00 AM 08/28/2019
Misc
Corrective Action Required
08/28/2019
NOT READY. NO PLAN ON SITE
Electrical Service Inspection Failed 8/29/2019 08/29/2019
Misc
Corrective Action Required
08/28/2019
-BOND THE METAL FITTING BETWEEN THE METER AND SERVICE DISCONNECT WITH BONDING BUSHING, LOCKNUT, ETC. BONDING JUMPER SHALL BE THE SAME SIZE AT GROUNDING ELECTRODE CONDUCTOR -DRIVE THE GROUNDING ROD TO GROUND
All Rough Inspection - Residential Failed 8/29/2019 8/29/2019 at 10:35 AM 08/29/2019
Misc
Corrective Action Required
08/28/2019
FRAMING: -Anchor sill plates within 12” of break in garage and basement -Fb all floor/ceiling penetrations -Support top of hip&valley rafters above pantry -Nail corner studs per code -Fb main floor wall from roof; Fb fireplace space with 3/4” sheathing or approved material -Install (3)2x4 stud support for lvl beam at foyer wall -Furdown for R-30 insulation above master bathroom -Install roof purlin support at max 4 ft interval above master bathroom -Support roof above stoop -Complete framing at bedroom window -Insulate first, then solidblock cantilevered joists above bearing wall -Fb basement wall per code -Provide solid support under foyer lvl point load ELECTRICAL: -Complete wiring to electrical fireplace -Electrical inside return air space above basement bottom stair landing and bathroom -Provide an outdoor receptacle at rear of house, reachable from and within 6.5 ft of grade -Protect wiring running across joist bottom MECHANICAL: -Complete thermostat control circuit PLUMBING: -Install roof flashing for vent pipes -Vent connection cannot be lower than tub trap weir -Protect plumbing in rear basement bedroom closet **DO NOT INSULATE
Electrical Service Inspection Passed 9/4/2019 9/4/2019 09/04/2019
Misc
Resolved
09/04/2019
-BOND THE METAL FITTING BETWEEN THE METER AND SERVICE DISCONNECT WITH BONDING BUSHING, LOCKNUT, ETC. BONDING JUMPER SHALL BE THE SAME SIZE AT GROUNDING ELECTRODE CONDUCTOR -DRIVE THE GROUNDING ROD TO GROUND
All Rough Inspection - Residential Failed 9/4/2019 9/4/2019 at 8:45 AM 09/04/2019
Misc
Corrective Action Required
08/29/2019
FRAMING: -Anchor sill plates within 12” of break in basement -Install (3)2x4 stud support for lvl beam at foyer wall **Complete electrical -Complete framing at bedroom window **Complete electrical -Insulate first, then solidblock cantilevered joists above bearing wall -Fb basement wall per code **Fb wall vertically at ten ft or less interval; fb wall from ceiling furdown space -Provide solid support under foyer lvl point load **OK TO INSULATE
All Rough Inspection - Residential Failed 9/9/2019 9/9/2019 at 10:20 AM 09/09/2019
Misc
Corrective Action Required
09/04/2019
FRAMING: -Insulate first, then solidblock cantilevered joists above bearing wall -Provide solid support under foyer lvl point load **OK TO INSULATE
All Rough Inspection - Residential Failed 9/10/2019 9/10/2019 at 8:50 AM 09/10/2019
Misc
Corrective Action Required
09/09/2019
FRAMING: -Insulate first, then solidblock cantilevered joists above bearing wall
All Rough Inspection - Residential Passed 9/13/2019 9/13/2019 at 9:05 AM 09/13/2019
Misc
Resolved
09/13/2019
FRAMING: -Insulate first, then solidblock cantilevered joists above bearing wall
Driveway Inspection Partial 9/24/2019 09/24/2019
Misc
Informational
09/24/2019
Driveway forms and materials passed pre-inspection.
Driveway Inspection Passed 09/25/2019
Misc
Informational
09/24/2019
Driveway forms and materials passed pre-inspection.
Misc
Informational
09/25/2019
Driveway - passed final inspection.
Erosion Control Inspection Residential Failed 10/22/2019 10/22/2019
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/28/2019
DEFICIENT EROSION CONTROL INSTALLATION. RESTORE EROSION CONTROL ALONG STREET NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM5 ESC INSP DENIED
Corrective Action Required
10/22/2019
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -------------------------------------- Swale at rear yard needs to be Corrected and silt fence established. Contact Steve Robbins or Mark Harding retaining wall needs to be approved prior to final CofO
Occupancy Inspection - Codes Residential Failed 3/30/2020 3/30/2020 at 1:05 PM 03/30/2020
Misc
Corrective Action Required
03/30/2020
**REPAIR EROSION CONTROL AT SIDE AND REAR OF LOT -Install address -As-graded plot plan is required prior to sodding -Final grade, sod, downspout extensions -Seal exterior wall penetrations, seal any wall protrusion -Secure AC whip; Id ungrounded conductors with proper color -Install tamper proof caps at AC valves -Install box extension for floor receptacle box -Install secondary locks for all slide door -Secure cooktop FMC within 12” of j-box -Provide gfci protection for dish washer and laundry outlets per NEC 210.8(A) and (D) -Access needed for garage receptacle -Receptacle at wet bar sink keeps tripping -Anchor basement column -All 15-20 amp outlets in kitchen, living room, laundry must be afci-protected -Locate and make accessible the sewer clean out
Misc
Corrective Action Required
04/09/2020
NO TCO OR C OF O AS PER MARK HARDING AND DAN HARPER UNTIL SWALE HAS BEEN REPAIRED CLEANED AND INSPECTED.
Occupancy Inspection - Codes Residential Failed 4/15/2020 4/15/2020 at 10:05 AM 04/15/2020
Misc
Corrective Action Required
03/30/2020
**REPAIR EROSION CONTROL AT SIDE AND REAR OF LOT -Install address -As-graded plot plan is required prior to sodding -Final grade, sod, downspout extensions -Seal exterior wall penetrations, seal any wall protrusion -Install tamper proof caps at AC valves -Install secondary locks for all slide door **Bottom mounted bolt assy or pin -Anchor basement column -All 15-20 amp outlets in kitchen, living room, laundry must be afci-protected **freezer and fireplace breakers -Locate and make accessible the sewer clean out
Misc
Corrective Action Required
04/09/2020
NO TCO OR C OF O AS PER MARK HARDING AND DAN HARPER UNTIL SWALE HAS BEEN REPAIRED CLEANED AND INSPECTED.
Plot Plan Inspection Passed 4/17/2020 04/17/2020
Occupancy Inspection - Codes Residential Temporary C of O 4/17/2020 4/17/2020 at 9:15 AM 04/17/2020
Misc
Corrective Action Required
04/15/2020
-Sod -Seal exterior wall penetrations, seal any wall protrusion -Install tamper proof caps at AC valves -Locate and make accessible the sewer clean out
Misc
Corrective Action Required
04/15/2020
NO TCO OR C OF O AS PER MARK HARDING AND DAN HARPER UNTIL SWALE HAS BEEN REPAIRED CLEANED AND INSPECTED.
Occupancy Inspection - Codes Residential Failed 4/22/2020 4/22/2020 at 9:15 AM 04/22/2020
Misc
Corrective Action Required
04/17/2020
-Locate and make accessible the sewer clean out -Dont cover the sewer tracer port. Expose it
Misc
Corrective Action Required
04/17/2020
NO TCO OR C OF O AS PER MARK HARDING AND DAN HARPER UNTIL SWALE HAS BEEN REPAIRED CLEANED AND INSPECTED.
Occupancy Inspection - Codes Residential Temporary C of O 4/23/2020 4/23/2020 at 9:30 AM 04/23/2020
Misc
Resolved
04/23/2020
-Locate and make accessible the sewer clean out -Dont cover the sewer tracer port. Expose it
Misc
Corrective Action Required
04/22/2020
NO TCO OR C OF O AS PER MARK HARDING AND DAN HARPER UNTIL SWALE HAS BEEN REPAIRED CLEANED AND INSPECTED.
Erosion Control Inspection Residential Passed 12/14/2020
DCM2 ESC DEFICIENT INSTALLATION
Resolved
04/22/2020
DEFICIENT EROSION CONTROL INSTALLATION. RESTORE EROSION CONTROL ALONG STREET NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM5 ESC INSP DENIED
Resolved
12/14/2020
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -------------------------------------- Swale at rear yard needs to be Corrected and silt fence established. Contact Steve Robbins or Mark Harding retaining wall needs to be approved prior to final CofO
Occupancy Inspection - Codes Residential Full C of O 6/22/2020 12/14/2020
Misc
Resolved
12/14/2020
NO TCO OR C OF O AS PER MARK HARDING AND DAN HARPER UNTIL SWALE HAS BEEN REPAIRED CLEANED AND INSPECTED.
Documents & Images
Date Uploaded File Type Document Name
06/12/2019 Letter Codes Residential Plan Review
06/13/2019 Receipt Receipt for transaction: 2019-003640
06/13/2019 Letter Codes Building Permit
06/13/2019 Plot Plan DOC061319-06132019140018
06/24/2019 Engineer Report/Study Garys Fndn 4713 NE Saratoga Ct Lee's Summit Mo Footing Forming and Reinforcement 6-20-19
07/02/2019 Letter INSPECTION SUMMARY
07/02/2019 Letter INSPECTION SUMMARY
07/18/2019 Letter INSPECTION SUMMARY
07/24/2019 Letter INSPECTION SUMMARY
08/09/2019 Letter INSPECTION SUMMARY
08/28/2019 Letter INSPECTION SUMMARY
08/28/2019 Letter INSPECTION SUMMARY
08/28/2019 Letter INSPECTION SUMMARY
08/28/2019 Letter INSPECTION SUMMARY
08/29/2019 Letter INSPECTION SUMMARY
08/29/2019 Letter INSPECTION SUMMARY
09/04/2019 Letter INSPECTION SUMMARY
09/04/2019 Letter INSPECTION SUMMARY
09/09/2019 Letter INSPECTION SUMMARY
09/10/2019 Letter INSPECTION SUMMARY
09/13/2019 Letter INSPECTION SUMMARY
09/25/2019 Letter INSPECTION SUMMARY
10/22/2019 Letter INSPECTION SUMMARY
12/16/2019 Engineer Report/Study 4713 NE Saratoga Ct_Lot 97 Monticello Final_2019.12.09_Wall_LSMO_Pat Cochran Concrete
03/30/2020 Letter INSPECTION SUMMARY
04/15/2020 Letter INSPECTION SUMMARY
04/17/2020 Plot Plan M-97-AS-GRADED
04/17/2020 Letter INSPECTION SUMMARY
04/17/2020 Letter Codes Temporary Certificate of Occupancy
04/22/2020 Letter INSPECTION SUMMARY
04/23/2020 Letter Codes Temporary Certificate of Occupancy
12/14/2020 Letter INSPECTION SUMMARY
12/14/2020 Email RE 4713 NE SARATOGA CT
12/14/2020 Letter Codes Final Certificate of Occupancy
12/14/2020 Letter Field Certificate of Occupancy
12/14/2020 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home