Summary
PRRES20163205
Building Permit - Residential
Certificate of Occupancy
SILVERSTONE DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY HOME PARTIAL FINISHED BASEMENT COVERED DECK
12/14/2016
01/12/2017
10/30/2017
Locations
Contacts
SILVERSTONE DEVELOPMENT LLC, Address:PO BOX 219119  
DAVE RICHARDS HOMEBUILDING INC, Address:605 SW US HIGHWAY 40 #414, Phone:(816) 365-8034  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review (P&D) Approved 12/16/2016 12/19/2016
Jonathon Hilton
Plot Plan Review (P&D) Approved 12/16/2016 12/19/2016
Jonathon Hilton
Residential Plan Review Approved 12/16/2016 12/16/2016
Jonathon Hilton
Plot Plan Review Approved 12/16/2016 12/15/2016
Jonathon Smith
Plot Plan Review (P&D) Rejected 12/16/2016 12/14/2016
Jennifer Thompson
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $895.73 $895.73 Paid 01/12/2017
8331507-Sewer Connection Fee $360.00 $360.00 Paid 01/12/2017
Water Tap Fee $3,310.00 $3,310.00 Paid 01/12/2017
Water Meter Fee $405.36 $405.36 Paid 01/12/2017
Right of Way Permit Fee $75.00 $75.00 Paid 01/12/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/18/2017 (11:00) 1/18/2017 01/18/2017
Sewer Service Inspection - R Passed 2/16/2017 (1:00) 2/16/2017 02/16/2017
Water Service Inspection - R Partial 2/17/2017 (8:00) 2/17/2017 02/17/2017
Water Service Inspection - R Passed 2/17/2017 (2:00) 2/17/2017 02/17/2017
Underslab Plumbing Inspection - Residential Passed 2/21/2017 2/21/2017 02/21/2017
Gas Service Inspection - Residential Passed 5/11/2017 5/11/2017 05/11/2017
Electrical Service Inspection Failed 5/11/2017 5/11/2017 05/11/2017
Misc
Corrective Action Required
05/11/2017
-PROVIDE LADDER ON SITE TO INSPECT THE GROUNDING CONNECTION TO UFER REBAR
All Rough Inspection - Residential Failed 5/11/2017 5/11/2017 05/11/2017
Misc
Corrective Action Required
05/11/2017
***INSPECTION DENIED. NO PLAN ON SITE ***TOO MANY DEFICIENCIES. HAVE ALL YOUR SUBS RE-CHECK ALL THEIR WORKS
All Rough Inspection - Residential Failed 5/12/2017 5/12/2017 05/12/2017
Misc
Corrective Action Required
05/11/2017
FRAMING: -NAIL SIDING PER CODE. TO SILL PLATE @ 6" OC -INSTALL FLASHING AT STOOP; ABOVE ALL EXTERIOR TRIMS -GARAGE PORTAL BRACE WALLS: SEAM IN SHEATHING SHALL BE WITHIN 24" OF THE WALL MID-HEIGHT; YOU HAVE A SEAM THAT IS JUST BELOW THE HEADER; SEAM SHALL BE BLOCKED AND NAILED PER CODE; STRAP THE INNER SIDE OF THE PORTAL PER DETAIL. SEE PLAN -INSTALL COLLAR TIES AT INTERVAL NO MORE THAN 4 FT -BRACE INTERIOR WALLS PER PLAN -FIREBLOCKING: FB FIREPLACE SPACE, FB ALL BASEMENT WALL FROM JOIST SPACE AND CEILING FURDOWN AND SOFFIT SPACE; FIRESTOP ALL FLOOR/CEILING PENETRATIONS -SUPPORT HIPS ABOVE FRONT BED -NAIL ALL HANGERS THROUGHOUT -OVERNOTCHED JOIST BELOW FRONT BATH TOILET -EXPOSE THE FLOOR SPACE UNDER THE LAUNDRY DRAIN PLUMBING: -INSTALL STUD SHOE AT LAUNDRY -IN BASEMENT BATH, INSTALL STUD SHOES FOR ALL BEARING WALL STUDS BORED MORE THAN 40% ELECTRICAL: -INSTALL FLOOD LIGHT AT REAR -STUD AT PANEL BORED MORE THAN 40% SHALL BE REINFORCED WITH A STUD SHOE -WIRING RUNNING ACROSS JOISTS AND STUDDINGS WITHIN SIX FT OF ATTIC ACCESS MUST BE PROTECTED -PROTECT WIRING AT REAR BASEMENT WALL NEAR STAIR WHERE SECURED ALONG STUD WITHIN 1.25" OF NAILING SURFACE -PROVIDE WALL RECEPTACLE SPACING PER CODE NEAR WET BAR ***OK TO INSULATE
Electrical Service Inspection Passed 5/12/2017 5/12/2017 05/12/2017
Misc
Resolved
05/12/2017
-PROVIDE LADDER ON SITE TO INSPECT THE GROUNDING CONNECTION TO UFER REBAR
All Rough Inspection - Residential Failed 5/16/2017 5/16/2017 05/16/2017
Misc
Corrective Action Required
05/12/2017
FRAMING: -GARAGE PORTAL BRACE WALLS: SEAM IN SHEATHING SHALL BE WITHIN 24" OF THE WALL MID-HEIGHT; YOU HAVE A SEAM THAT IS JUST BELOW THE HEADER; SEAM SHALL BE BLOCKED AND NAILED PER CODE; STRAP THE INNER SIDE OF THE PORTAL PER DETAIL. SEE PLAN -FIREBLOCKING: FB FIREPLACE SPACE -EXPOSE THE FLOOR SPACE UNDER THE LAUNDRY DRAIN **OVERNOTCHED DOUBLE JOIST. ELECTRICAL: -WIRING RUNNING ACROSS STUDDINGS WITHIN SIX FT OF ATTIC ACCESS MUST BE PROTECTED ***OK TO INSULATE
All Rough Inspection - Residential Failed 5/18/2017 5/18/2017 05/18/2017
Misc
Corrective Action Required
05/16/2017
FRAMING: -GARAGE PORTAL BRACE WALLS: SEAM IN SHEATHING SHALL BE WITHIN 24" OF THE WALL MID-HEIGHT; YOU HAVE A SEAM THAT IS JUST BELOW THE HEADER; SEAM SHALL BE BLOCKED AND NAILED PER CODE; STRAP THE INNER SIDE OF THE PORTAL PER DETAIL. SEE PLAN **THE ROOFER CUT THE SHEATHING TO INSERT THE FLASHING. THIS REALLY COMPROMISE THE SHEARING CAPACITY OF THE BRACE WALL. YOU CAN HAVE THE ENGINEER ADDRESS FIX FOR THIS ***OK TO ROCK, EXCEPT AT THE GARAGE PORTAL WALLS. LEAVE THESE AREAS OPEN
Driveway Inspection Passed 6/5/2017 6/5/2017 06/05/2017
Sidewalk Inspection Passed 6/5/2017 6/5/2017 06/05/2017
All Rough Inspection - Residential Failed 6/7/2017 6/7/2017 06/07/2017
Misc
Corrective Action Required
05/18/2017
FRAMING: -GARAGE PORTAL BRACE WALLS: SEAM IN SHEATHING SHALL BE WITHIN 24" OF THE WALL MID-HEIGHT; YOU HAVE A SEAM THAT IS JUST BELOW THE HEADER; SEAM SHALL BE BLOCKED AND NAILED PER CODE; STRAP THE INNER SIDE OF THE PORTAL PER DETAIL. SEE PLAN **THE ROOFER CUT THE SHEATHING TO INSERT THE FLASHING. THIS REALLY COMPROMISE THE SHEARING CAPACITY OF THE BRACE WALL. YOU CAN HAVE THE ENGINEER ADDRESS FIX FOR THIS ***OK TO ROCK, EXCEPT AT THE GARAGE PORTAL WALLS. LEAVE THESE AREAS OPEN
All Rough Inspection - Residential Passed 6/9/2017 6/9/2017 06/09/2017
Misc
Resolved
06/09/2017
FRAMING: -GARAGE PORTAL BRACE WALLS: SEAM IN SHEATHING SHALL BE WITHIN 24" OF THE WALL MID-HEIGHT; YOU HAVE A SEAM THAT IS JUST BELOW THE HEADER; SEAM SHALL BE BLOCKED AND NAILED PER CODE; STRAP THE INNER SIDE OF THE PORTAL PER DETAIL. SEE PLAN **THE ROOFER CUT THE SHEATHING TO INSERT THE FLASHING. THIS REALLY COMPROMISE THE SHEARING CAPACITY OF THE BRACE WALL. YOU CAN HAVE THE ENGINEER ADDRESS FIX FOR THIS ***Repairs appear to have been made per Engineer's Letter. ***OK TO ROCK, EXCEPT AT THE GARAGE PORTAL WALLS. LEAVE THESE AREAS OPEN
Piers/Caissons Inspection - Residential Passed 8/18/2017 (2:00) 8/18/2017 08/18/2017
Occupancy Inspection - Codes Residential Failed 8/25/2017 8/25/2017 08/25/2017
Misc
Corrective Action Required
08/25/2017
-FINAL GRADE, SOD, ROOF GUTTER/DOWNSPOUTS/ SPLASHBLOCKS -EXPOSE SEWER TRACER BOX -EXPOSE WATER METER ****NOT READY FOR INSPECTION. ELECTRICAL NOT READY, STILL PAINTING INSIDE, ELECTRICAL OUTLETS COVERED, ETC
Occupancy Inspection - Codes Residential Failed 8/28/2017 8/28/2017 08/28/2017
Misc
Corrective Action Required
08/25/2017
-FINAL GRADE, SOD, SPLASHBLOCKS -EXPOSE SEWER TRACER BOX -ESTABLISH GAS SERVICE -SEAL EXTERIOR WALL PENETRATIONS, ABOVE AC DISCONNECT AND METER, ETC -COOKTOP: INSTALL FMC CONNECTOR AT BOX ABD SECURE FMC WITHIN 12" OF BOX AND COOKTOP -RECEPTACLE WITHIN SIX FT OF THE WET BAR SINK MUST BE GFCI-PROTECTED -WHERE'S THE UFER GROUNDING CONNECTION? -REMOVE ALL SMOKE ALARM COVERS
Occupancy Inspection - Codes Residential Temporary C of O 8/29/2017 8/28/2017 08/28/2017
Misc
Corrective Action Required
08/28/2017
-FINAL GRADE, SOD, SPLASHBLOCKS -EXPOSE SEWER TRACER BOX -ESTABLISH GAS SERVICE -SEAL EXTERIOR WALL PENETRATIONS, ABOVE AC DISCONNECT AND METER, ETC -COOKTOP: INSTALL FMC CONNECTOR AT BOX ABD SECURE FMC WITHIN 12" OF BOX AND COOKTOP -RECEPTACLE WITHIN SIX FT OF THE WET BAR SINK MUST BE GFCI-PROTECTED -WHERE'S THE UFER GROUNDING CONNECTION? -REMOVE ALL SMOKE ALARM COVERS
Occupancy Inspection - Codes Residential Temporary C of O 8/29/2017 8/29/2017 08/29/2017
Misc
Corrective Action Required
08/28/2017
-FINAL GRADE, SOD, SPLASHBLOCKS -EXPOSE SEWER TRACER BOX -EXPOSE THE SUMP PUMP DISCHARGE
Occupancy Inspection - Codes Residential Failed 9/28/2017 9/28/2017 at 9:10 AM 09/28/2017
Misc
Corrective Action Required
08/29/2017
-EXPOSE SEWER TRACER BOX
Occupancy Inspection - Codes Residential Full C of O 10/30/2017 at 9:40 AM 10/30/2017
Misc
Corrective Action Required
09/28/2017
-EXPOSE SEWER TRACER BOX
Documents & Images
Date Uploaded File Type Document Name
01/12/2017 Receipt Receipt for transaction: 2017-000108
01/12/2017 Letter Codes Building Permit
01/13/2017 Plot Plan DOC011317-004
01/18/2017 Letter Inspection Summary
02/16/2017 Letter Inspection Summary
02/17/2017 Letter Inspection Summary
02/17/2017 Letter Inspection Summary
02/21/2017 Letter Inspection Summary
05/11/2017 Letter Inspection Summary
05/12/2017 Letter Inspection Summary
05/16/2017 Letter Inspection Summary
05/18/2017 Letter Inspection Summary
06/05/2017 Letter Inspection Summary
06/07/2017 Letter Inspection Summary
06/09/2017 Letter Inspection Summary
06/15/2017 Engineer Report/Study DOC061517-009
08/18/2017 Letter Inspection Summary
08/25/2017 Letter Inspection Summary
08/28/2017 Letter Inspection Summary
08/28/2017 Letter Codes Temporary Certificate of Occupancy
08/29/2017 Letter Codes Temporary Certificate of Occupancy
09/28/2017 Letter Inspection Summary
10/30/2017 Letter Field Certificate of Occupancy
10/31/2017 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: