Permit Application Status

PRRES20162250


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20162250
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW SINGLE FAMILY COVERED DECK FINISHED BASEMENT
09/02/2016
09/19/2016
01/02/2018
Locations
Contacts
D AND D BUILDING INC, Address:PO BOX 7014, Phone:(816) 491-2125  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 09/15/2016
Jonathon Hilton
Plot Plan Review Rejected 09/09/2016
James Fletchall
Residential Plan Review Approved 09/07/2016 09/08/2016
Jonathon Hilton
Plot Plan Review (P&D) Approved 09/07/2016 09/06/2016
Jennifer Thompson
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $997.70 $997.70 Paid 09/19/2016
8331507-Sewer Connection Fee $540.00 $540.00 Paid 09/19/2016
Water Tap Fee $3,310.00 $3,310.00 Paid 09/19/2016
Water Meter Fee $405.36 $405.36 Paid 09/19/2016
Right of Way Permit Fee $75.00 $75.00 Paid 09/19/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/23/2016 (2:30) 9/23/2016 09/23/2016
Underslab Plumbing Inspection - Residential Passed 10/18/2016 10/18/2016 10/18/2016
Sewer Service Inspection - R Passed 10/24/2016 (2:30) 10/24/2016 10/24/2016
Water Service Inspection - R Passed 10/25/2016 (1:00) 10/25/2016 10/25/2016
Gas Service Inspection - Residential Passed 1/31/2017 1/31/2017 01/31/2017
Electrical Service Inspection Passed 2/9/2017 2/9/2017 02/09/2017
All Rough Inspection - Residential Failed 2/9/2017 2/9/2017 02/09/2017
Misc
Corrective Action Required
02/08/2017
****CLEAN STREET AND RESTORE EROSION CONTROL FRAMING: -HAVE PLAN ON SITE. CHECK CS-PF WALL AT REAR DINING AND MASTER BED -MASTER CLOSET WALL NOT BEARING WALL -FIREBLOCKING: FB ALL FLOOR PENETRATIONS; FB FIREPLACE SPACE FROM ROOF WITH 3/4" SHEATHING; FB BASEMENT WALL SPACE FROM CEILING FURDONW SPACE AND VERTICALLY EVERY TEN FT OR LESS; FB BASEMENT FIREPLACE SPACE FROM HORIZONTAL SPACE. FIREBLOCK WITH APPROVED MATERIAL. 1/2" SHEATHING IS NOT APPROVED; -ALL EXTERIOR DOORS: FILL IN GAPS AT HINGES AND STRIKE PLATES PER LS SECURITY CODE; BLOCK DOOR STUDS 3 STUD SPACES OUT OR TO CORNER -HAVE ENGINEER ADDRESS FIX FOR OVER-NOTCHED JOIST ABOVE WET BAR -TOE NAIL ALL JOISTS TO SILL AND TOP PLATES WITH 3-8D NAILS -ANCHOR SHORT PLATE AT REAR BASEMENT BED CLOSET MECHANICAL: -FASTEN FIREPLACE TO FRAMING -LOWER SUPPLY AIR TO CEILING LEVEL AT BATH NEAR WET BAR PLUMBING: -CONNECT GAS TO FIREPLACE -SUPPORT DRAIN PIPE NO MORE THAN 4FT INTERVAL OUTSIDE BASEMENT BEDS ELECTRICAL: -WALL RECEPTACLE SPACING NOT COMPLIANT IN MASTER BEDROOM -WIRING RUNNING ACROSS CEILING JOISTS WITHIN SIX FT OF ATTIC ACCESS SHALL BE PROTECTED WITH RUNNING BOARD ***OK TO INSULATE
All Rough Inspection - Residential Failed 2/10/2017 2/10/2017 02/10/2017
Misc
Corrective Action Required
02/09/2017
****CLEAN STREET AND RESTORE EROSION CONTROL FRAMING: -FRAME PER PLAN-CS-PF WALLS AT FRONT BED, REAR DINING, AND MASTER BED -BRACE INTERIOR WALLS PER PLAN -MASTER CLOSET WALL NOT BEARING WALL -FIREBLOCKING: FB ALL FLOOR PENETRATIONS; FB FIREPLACE SPACE FROM ROOF WITH 3/4" SHEATHING; FB BASEMENT WALL SPACE FROM CEILING FURDONW SPACE AND VERTICALLY EVERY TEN FT OR LESS; FB BASEMENT FIREPLACE SPACE FROM HORIZONTAL SPACE. FIREBLOCK WITH APPROVED MATERIAL. 1/2" SHEATHING IS NOT APPROVED; -ALL EXTERIOR DOORS: FILL IN GAPS AT HINGES AND STRIKE PLATES PER LS SECURITY CODE; BLOCK DOOR STUDS 3 STUD SPACES OUT OR TO CORNER -HAVE ENGINEER ADDRESS FIX FOR OVER-NOTCHED JOIST ABOVE WET BAR -TOE NAIL ALL JOISTS TO SILL AND TOP PLATES WITH 3-8D NAILS -ANCHOR SHORT PLATE AT REAR BASEMENT BED CLOSET MECHANICAL: -FASTEN FIREPLACE TO FRAMING -LOWER SUPPLY AIR TO CEILING LEVEL AT BATH NEAR WET BAR PLUMBING: -CONNECT GAS TO FIREPLACE -SUPPORT DRAIN PIPE NO MORE THAN 4FT INTERVAL OUTSIDE BASEMENT BEDS ELECTRICAL: -WALL RECEPTACLE SPACING NOT COMPLIANT IN MASTER BEDROOM -WIRING RUNNING ACROSS CEILING JOISTS WITHIN SIX FT OF ATTIC ACCESS SHALL BE PROTECTED WITH RUNNING BOARD ***OK TO INSULATE
Suspended Slab Inspection Passed 02/14/2017
All Rough Inspection - Residential Failed 2/14/2017 2/14/2017 02/14/2017
Misc
Corrective Action Required
02/10/2017
FRAMING: -FRAME PER PLAN-CS-PF WALLS AT FRONT BED, REAR DINING, AND MASTER BED **SEE DETAIL OF A/4 -BRACE INTERIOR WALLS PER PLAN -FIREBLOCKING: FB FIREPLACE SPACE FROM ROOF WITH 3/4" SHEATHING; FB BASEMENT WALL SPACE FROM CEILING FURDONW SPACE AND VERTICALLY EVERY TEN FT OR LESS; FB BASEMENT FIREPLACE SPACE FROM HORIZONTAL SPACE. FIREBLOCK WITH APPROVED MATERIAL. 1/2" SHEATHING IS NOT APPROVED; **COMMENT: FIBERGLASS INSULATION USED AS FIREBLOCKING MATERIAL MUST FILL THE WHOLE DEPTH OF FURRED OUT WALL. IT ALSO MUST BE SECURED IN PLACE SO THAT IT WILL NOT FALL OFF DURING THE LIFETIME OF THE BUILDING -ALL EXTERIOR DOORS: FILL IN GAPS AT HINGES AND STRIKE PLATES PER LS SECURITY CODE -HAVE ENGINEER ADDRESS FIX FOR OVER-NOTCHED JOIST ABOVE WET BAR ***OK TO INSULATE
All Rough Inspection - Residential Partial 2/16/2017 2/16/2017 02/16/2017
Misc
Corrective Action Required
02/14/2017
-FRAME PER PLAN-CS-PF WALLS AT FRONT BED, REAR DINING, AND MASTER BED -HAVE ENGINEER ADDRESS FIX FOR OVER-NOTCHED JOIST ABOVE WET BAR **ENGINEER LETTER REQUIRED FOR THE ABOVE FIXES. ROCK AT OWN RISK
Driveway Inspection Partial 3/14/2017 3/14/2017 03/14/2017
PW-Misc
Informational
03/14/2017
The approach is good, rock is in and compacted. The driveway in the approach/ROW was 39 ft wide. I told them it can only be 36 ft. They said they would make it 36.Steve Robbins 03/14/2017 3:54 PM
Driveway Inspection Partial 3/27/2017 03/27/2017
PW-Misc
Informational
03/14/2017
The approach is good, rock is in and compacted. The driveway in the approach/ROW was 39 ft wide. I told them it can only be 36 ft. They said they would make it 36.Steve Robbins 03/14/2017 3:54 PM
PW-Misc
Informational
03/27/2017
I drove by the job sight and they still havent poured the approach yet.Steve Robbins 03/27/2017 3:55 PM
Sidewalk Inspection Passed 4/12/2017 4/12/2017 04/12/2017
All Rough Inspection - Residential Passed 04/19/2017
Misc
Resolved
04/19/2017
-FRAME PER PLAN-CS-PF WALLS AT FRONT BED, REAR DINING, AND MASTER BED -HAVE ENGINEER ADDRESS FIX FOR OVER-NOTCHED JOIST ABOVE WET BAR **ENGINEER LETTER REQUIRED FOR THE ABOVE FIXES. ROCK AT OWN RISK
Occupancy Inspection - Codes Residential Failed 4/19/2017 4/19/2017 04/19/2017
Misc
Corrective Action Required
04/19/2017
-DRIVEWAY NOT APPROVED ON RECORD -DECK PIERS WERE NOT INSPECTED AND APPROVED -OBTAIN LAWN IRRIGATION PERMIT -FINAL GRADE, SOD, SPLASHBLOCKS -EXPOSE SEWER TRACER BOX -SEAL EXTERIOR: ALL WALL PENETRATIONS, ABOVE METER AND AC DISCONNECT, ALL EXTERIOR LIGHTS -AC UNGROUNDED AC CONDUCTORS WITH APPROVED COLOR -COMPLETE OUTDOOR ELECTRICAL AT GRILL; UNDERGROUND CONDUCTORS SHALL BE RATED FOR WET LOCATION -INSTALL FLOOD LIGHT TO ILLUMINATE THE BACKYARD -ANCHOR THE COLUMNS IN SPACE UNDER SUSPENDED GARAGE -EXPOSE THE LIGHT SWITCH FOR UNDER-STOOP LIGHT -INSTALL AT LEAST ONE RECEPTACLE IN EACH SEPARATE UNFINISHED BASEMENT PORTION -INSTALL BREAKER LOCK FOR OVEN AND COOKTOP -RECEPTACLE WITHIN SIX FT OF THE WET BAR SINK MUST BE GFCI -ALL EXTERIOR DOORS (EXCEPT THE FRONT ENTRY DOOR) MUST HAVE SECURITY STRIKE PLATE WITH 3" SCREWS SCREWED INTO THE STUDS -THE FRONT BASEMENT BED CLOSET LIGHT MUST HAVE MIN. 12" CLEARANCE -INSTALL 2 LIGHTS IN MASTER BATH; INSTALL COVER PLATE FOR ENTRY CEILING LIGHT -GARAGE AND PANTRY-GARAGE DOORS SHALL BE SELF-CLOSING -ALL GARAGE RECEPTACLES MUST BE GFCI; SUPPORT ALL RECEPTACLE YOKES
Driveway Inspection Passed 4/13/2017 04/21/2017
PW-Misc
Informational
03/27/2017
The approach is good, rock is in and compacted. The driveway in the approach/ROW was 39 ft wide. I told them it can only be 36 ft. They said they would make it 36.Steve Robbins 03/14/2017 3:54 PM
PW-Misc
Informational
03/27/2017
I drove by the job sight and they still havent poured the approach yet.Steve Robbins 03/27/2017 3:55 PM
Occupancy Inspection - Codes Residential Failed 6/28/2017 6/28/2017 06/28/2017
Misc
Corrective Action Required
04/19/2017
-DECK PIERS WERE NOT INSPECTED AND APPROVED **HAVE YOUR ENGINEER TO APPROVE THE PIERS AND SEND US A LETTER APPROVING THE PIERS -OBTAIN LAWN IRRIGATION PERMIT -EXPOSE SEWER TRACER BOX -INSTALL FLOOD LIGHT TO ILLUMINATE THE BACKYARD -ALL EXTERIOR DOORS (EXCEPT THE FRONT ENTRY DOOR) MUST HAVE SECURITY STRIKE PLATE WITH 3" SCREWS SCREWED INTO THE STUDS -GARAGE AND PANTRY-GARAGE DOORS ARE REQUIRED TO BE SELF-CLOSING
Occupancy Inspection - Codes Residential Failed 8/2/2017 8/2/2017 08/02/2017
Misc
Corrective Action Required
06/28/2017
-DECK PIERS WERE NOT INSPECTED AND APPROVED **HAVE YOUR ENGINEER TO APPROVE THE PIERS AND SEND US A LETTER APPROVING THE PIERS
Occupancy Inspection - Codes Residential Full C of O 1/2/2018 1/2/2018 at 8:35 AM 01/02/2018
Misc
Resolved
01/02/2018
-DECK PIERS WERE NOT INSPECTED AND APPROVED **HAVE YOUR ENGINEER TO APPROVE THE PIERS AND SEND US A LETTER APPROVING THE PIERS
Documents & Images
Date Uploaded File Type Document Name
09/19/2016 Receipt Receipt for transaction: 2016-005996
09/19/2016 Letter Codes Building Permit
09/19/2016 Plot Plan DOC091916-004
09/19/2016 Engineer Report/Study DOC091916-005
09/19/2016 Engineer Report/Study DOC091916
09/23/2016 Letter Inspection Summary
10/18/2016 Letter Inspection Summary
10/24/2016 Letter Inspection Summary
10/25/2016 Letter Inspection Summary
11/03/2016 Engineer Report/Study DOC110316-010
01/31/2017 Letter Inspection Summary
02/09/2017 Letter Inspection Summary
02/10/2017 Letter Inspection Summary
02/14/2017 Letter Inspection Summary
02/16/2017 Letter Inspection Summary
03/07/2017 Engineer Report/Study 16-008-28 Field Modifications Letter
03/14/2017 Letter PW-Daily Inspection Summary
03/27/2017 Letter PW-Daily Inspection Summary
04/12/2017 Letter PW-Daily Inspection Summary
04/19/2017 Letter Inspection Summary
04/21/2017 Letter Inspection Summary
06/28/2017 Letter Inspection Summary
08/02/2017 Letter Inspection Summary
12/18/2017 inspection report 20172250
01/02/2018 Letter Field Certificate of Occupancy
01/04/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home