Permit Application Status

PRRES20131163


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20131163
Building Permit - Residential
Certificate of Occupancy
JOHN KNOX VILLAGE
NEW DUPLEX
DUPLEX
06/11/2013
11/15/2013
08/15/2014
Locations
Contacts
LARRY HARKRADER CONSTRUCTION, Address:401 NW MURRAY RD, Phone:(816) 607-7191  
AFC HEATING AND COOLING, Address:824 NW MAIN ST , Phone:(816) 347-8388  
S & L ELECTRIC INC, Address:1301 S POWELL, Phone:(816) 796-6859  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
JOHN KNOX VILLAGE, Address:400 NW MURRAY RD  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 06/13/2013 06/27/2013
Codes Admin
Plot Plan Review Approved 06/17/2013 06/26/2013
Gene Williams, P.E.
Plot Plan Review (P&D) Approved 06/17/2013 06/25/2013
Jennifer Thompson
Plot Plan Review Rejected 06/13/2013 06/13/2013
Gene Williams, P.E.
Corrective Action Required
06/13/2013

Not sealed by a design professional, encroachment into an existing easment, no existing and proposed elevations of the lot corners, building corners, garage elevations, etc. Need to go down the list of required items which are too numerous to list here.
Plot Plan Review (P&D) Rejected 06/13/2013 06/13/2013
Jennifer Thompson
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Duplex $893.79 $893.79 Paid 11/15/2013
$893.79
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/4/2013 (1:45) 12/4/2013 at 12:00 AM 12/04/2013
Sewer Service Inspection - R Passed 2/10/2014 (11:30) 2/10/2014 at 12:00 AM 02/10/2014
Water Service Inspection - R Partial 2/10/2014 (4:00) 2/10/2014 at 12:00 AM 02/10/2014
Misc
Partial Correction
02/10/2014
OK TO COVER WHEN READY WATER SERVICE LINE INSTALLATION FROM BOTH BUILDING ENTRIES TO NEAR METER LOCATION. FOOTING DRAIN DAMAGED AT UNIT "A" TO BE REPAIRED.
Water Service Inspection - R Passed 2/11/2014 2/11/2014 at 12:00 AM 02/11/2014
Misc
Resolved
02/11/2014
OK TO COVER WHEN READY WATER SERVICE LINE INSTALLATION FROM BOTH BUILDING ENTRIES TO NEAR METER LOCATION. FOOTING DRAIN DAMAGED AT UNIT "A" TO BE REPAIRED.
Underslab Plumbing Inspection - Residential Passed 2/12/2014 2/12/2014 at 12:00 AM 02/12/2014
All Rough Inspection - Residential Partial 2/27/2014 2/27/2014 at 12:00 AM 02/27/2014
Misc
Partial Correction
02/27/2014
SILL PLATES AND ANCHOR BOLTS COMPLETE & APPROVED.
All Rough Inspection - Residential Failed 4/29/2014 4/29/2014 at 12:00 AM 04/29/2014
Misc
Resolved
04/29/2014
SILL PLATES AND ANCHOR BOLTS COMPLETE & APPROVED.
Misc
Corrective Action Required
04/29/2014
UNITS A & B: STUD SHOES REQUIRED AT WASHER DRAIN PENETRATION OF STUDS
Misc
Corrective Action Required
04/29/2014
UNITS A & B: CARIFICATION RQUIRED RE CONCRETE CONTACT WITH UN-TREATED LUMBER.
Misc
Corrective Action Required
04/29/2014
UNIT B: FIRE-BLOCKING INCOMPLETE AT TOP PLATES AT FURNACE ROOM
All Rough Inspection - Residential Failed 4/29/2014 at 12:00 AM 05/01/2014
Misc
Corrective Action Required
04/29/2014
UNITS A & B: STUD SHOES REQUIRED AT WASHER DRAIN PENETRATION OF STUDS
Misc
Corrective Action Required
04/29/2014
UNITS A & B: CARIFICATION REQUIRED RE CONCRETE CONTACT WITH UN-TREATED LUMBER.
Misc
Corrective Action Required
04/29/2014
UNIT B: FIRE-BLOCKING INCOMPLETE AT TOP PLATES AT FURNACE ROOM
Electrical Service Inspection Failed 5/9/2014 5/9/2014 at 12:00 AM 05/09/2014
Misc
Corrective Action Required
05/09/2014
NEC 250.92B; IRC E3510.1. BONDING OF SERVICE ENCLOSURES & EQUIPMENT: NIPPLES ENTERING THROUGH REMAINING KNOCKOUTS REQUIRE BONDING BUSHINGS WITH BONDING JUMPERS TERMINATED AT ENCLOSURE HOUSINGS. LOCKNUT NOT SUFFICIENT FOR BONDING. MAY ALSO RUN SEPARATE BONDING CONDUCTOR LUGGED TO ENCLOSURES.
Gas Piping Inspection - Residential Passed 5/9/2014 5/9/2014 at 12:00 AM 05/09/2014
Electrical Service Inspection Passed 5/15/2014 5/15/2014 at 12:00 AM 05/15/2014
Misc
Resolved
05/15/2014
NEC 250.92B; IRC E3510.1. BONDING OF SERVICE ENCLOSURES & EQUIPMENT: NIPPLES ENTERING THROUGH REMAINING KNOCKOUTS REQUIRE BONDING BUSHINGS WITH BONDING JUMPERS TERMINATED AT ENCLOSURE HOUSINGS. LOCKNUT NOT SUFFICIENT FOR BONDING. MAY ALSO RUN SEPARATE BONDING CONDUCTOR LUGGED TO ENCLOSURES.
Occupancy Inspection - Codes Residential Not Ready 6/27/2014 6/27/2014 at 12:00 AM 06/27/2014
Misc
Partial Correction
06/27/2014
OK FOR USE & OCCUPANCY AT: UNIT A;
Occupancy Inspection - Codes Residential Failed 7/15/2014 7/15/2014 at 12:00 AM 07/15/2014
Misc
Partial Correction
06/27/2014
OK FOR USE & OCCUPANCY AT: UNIT A;
Misc
Corrective Action Required
07/15/2014
CRAWL SPACES AT UNITS B & A TO BE INSPECTED.
Misc
Corrective Action Required
07/15/2014
EXTERIOR/LOT SUBJECT TO APPROVAL WHEN COMPLETED. NOTE CODE CODE MINIMUM OF 6" CLEARANCE FROM FINISH GRADE TO SIDING OR OTHER WALL FINISH.
Misc
Corrective Action Required
07/15/2014
LOOSE/SOFT ELECT RECEPTS. EXAMPLE: GARAGE NE, BREAKFAST AREA, SE BR
Misc
Corrective Action Required
07/15/2014
CALL TO ATTENTION OF FIREPLACE INSTALLERS THAT MANUFACTURER'S TAG ATTACHED TO GAS CONNECTORS STATES MINIMUM BEND RADIUS AND THAT WE INTEND FOR IT TO BE FOLLOWED.
All Rough Inspection - Residential Passed 5/9/2014 at 12:00 AM 07/15/2014
Misc
Resolved
07/15/2014
UNITS A & B: STUD SHOES REQUIRED AT WASHER DRAIN PENETRATION OF STUDS
Misc
Resolved
07/15/2014
UNITS A & B: CARIFICATION REQUIRED RE CONCRETE CONTACT WITH UN-TREATED LUMBER.
Misc
Resolved
07/15/2014
UNIT B: FIRE-BLOCKING INCOMPLETE AT TOP PLATES AT FURNACE ROOM
Investigation Inspection Complete 7/16/2014 at 12:00 AM 07/16/2014
Occupancy Inspection - Codes Residential Failed 7/16/2014 at 12:00 AM 07/16/2014
Misc
Partial Correction
07/15/2014
OK FOR USE & OCCUPANCY AT: UNIT A;
Misc
Corrective Action Required
07/15/2014
CRAWL SPACES AT UNITS B & A TO BE INSPECTED.
Misc
Corrective Action Required
07/15/2014
EXTERIOR/LOT SUBJECT TO APPROVAL WHEN COMPLETED. NOTE CODE CODE MINIMUM OF 6" CLEARANCE FROM FINISH GRADE TO SIDING OR OTHER WALL FINISH.
Misc
Corrective Action Required
07/15/2014
LOOSE/SOFT ELECT RECEPTS. EXAMPLE: GARAGE NE, BREAKFAST AREA, SE BR
Misc
Corrective Action Required
07/15/2014
CALL TO ATTENTION OF FIREPLACE INSTALLERS THAT MANUFACTURER'S TAG ATTACHED TO GAS CONNECTORS STATES MINIMUM BEND RADIUS AND THAT WE INTEND FOR IT TO BE FOLLOWED.
Misc
Corrective Action Required
07/16/2014
CRAWL SPACES: 1) POST BASE PLATES NOT SECURED TO FOOTINGS 2) TEMPORARY LIGHT DROP CORD AND LIGHT LEFT IN PLACE AND BURNING. 3) SOME SHIMS NOT CENTERED AT WF BEAM BEARING 4) ONE OR MORE GROUNDING ELECTRODE TERMINATIONS NOT TIGHT 5) INFORMATION REQUIRED ON UNUSED VERTICAL PVC PLUMBING STUBS. TEMPORARY CAPS? 6) IS CRUSHED ROCK TO FINISH AT ELEVATION OF DRAIN. AS IS, ROCK IS WELL BELOW DRAIN AND CONDENSATE DRAINAGE POOLS IN THE DEPRESSIONS. 7) INVESTIGATION REQUIRED WHY UNDERSIDE OF STRUCTURE AND FLOOR INSULATION IS WET. INSULATION SAGGING OR FALLEN. MILDEW OR MOLD (?) ON SURFACE OF INSULATION AND BOTTOM CHORDS OF I-JOISTS.
Occupancy Inspection - Codes Residential Failed 7/16/2014 at 12:00 AM 07/16/2014
Misc
Partial Correction
07/16/2014
OK FOR USE & OCCUPANCY AT: UNIT A;
Misc
Resolved
07/16/2014
CRAWL SPACES AT UNITS B & A TO BE INSPECTED.
Misc
Corrective Action Required
07/16/2014
EXTERIOR/LOT SUBJECT TO APPROVAL WHEN COMPLETED. NOTE CODE CODE MINIMUM OF 6" CLEARANCE FROM FINISH GRADE TO SIDING OR OTHER WALL FINISH.
Misc
Corrective Action Required
07/16/2014
LOOSE/SOFT ELECT RECEPTS. EXAMPLE: GARAGE NE, BREAKFAST AREA, SE BR
Misc
Corrective Action Required
07/16/2014
CALL TO ATTENTION OF FIREPLACE INSTALLERS THAT MANUFACTURER'S TAG ATTACHED TO GAS CONNECTORS STATES MINIMUM BEND RADIUS AND THAT WE INTEND FOR IT TO BE FOLLOWED.
Misc
Corrective Action Required
07/16/2014
CRAWL SPACES: 1) POST BASE PLATES NOT SECURED TO FOOTINGS 2) TEMPORARY LIGHT DROP CORD AND LIGHT LEFT IN PLACE AND BURNING. 3) SOME SHIMS NOT CENTERED AT WF BEAM BEARING 4) ONE OR MORE GROUNDING ELECTRODE TERMINATIONS NOT TIGHT 5) INFORMATION REQUIRED ON UNUSED VERTICAL PVC PLUMBING STUBS. TEMPORARY CAPS? 6) IS CRUSHED ROCK TO FINISH AT ELEVATION OF DRAIN. AS IS, ROCK IS WELL BELOW DRAIN AND CONDENSATE DRAINAGE POOLS IN THE DEPRESSIONS. 7) INVESTIGATION REQUIRED WHY UNDERSIDE OF STRUCTURE AND FLOOR INSULATION IS WET. INSULATION SAGGING OR FALLEN. MILDEW OR MOLD (?) ON SURFACE OF INSULATION AND BOTTOM CHORDS OF I-JOISTS.
Occupancy Inspection - Codes Residential Not Ready 8/1/2014 8/1/2014 at 12:00 AM 08/01/2014
Misc
Partial Correction
07/16/2014
OK FOR USE & OCCUPANCY AT: UNIT A;
Misc
Corrective Action Required
07/16/2014
EXTERIOR/LOT SUBJECT TO APPROVAL WHEN COMPLETED. NOTE CODE CODE MINIMUM OF 6" CLEARANCE FROM FINISH GRADE TO SIDING OR OTHER WALL FINISH.
Misc
Corrective Action Required
07/16/2014
LOOSE/SOFT ELECT RECEPTS. EXAMPLE: GARAGE NE, BREAKFAST AREA, SE BR
Misc
Corrective Action Required
07/16/2014
CALL TO ATTENTION OF FIREPLACE INSTALLERS THAT MANUFACTURER'S TAG ATTACHED TO GAS CONNECTORS STATES MINIMUM BEND RADIUS AND THAT WE INTEND FOR IT TO BE FOLLOWED.
Misc
Corrective Action Required
07/16/2014
CRAWL SPACES: 1) POST BASE PLATES NOT SECURED TO FOOTINGS 2) TEMPORARY LIGHT DROP CORD AND LIGHT LEFT IN PLACE AND BURNING. 3) SOME SHIMS NOT CENTERED AT WF BEAM BEARING 4) ONE OR MORE GROUNDING ELECTRODE TERMINATIONS NOT TIGHT 5) INFORMATION REQUIRED ON UNUSED VERTICAL PVC PLUMBING STUBS. TEMPORARY CAPS? 6) IS CRUSHED ROCK TO FINISH AT ELEVATION OF DRAIN. AS IS, ROCK IS WELL BELOW DRAIN AND CONDENSATE DRAINAGE POOLS IN THE DEPRESSIONS. 7) INVESTIGATION REQUIRED WHY UNDERSIDE OF STRUCTURE AND FLOOR INSULATION IS WET. INSULATION SAGGING OR FALLEN. MILDEW OR MOLD (?) ON SURFACE OF INSULATION AND BOTTOM CHORDS OF I-JOISTS.
Misc
Corrective Action Required
08/01/2014
IBC 109.1, 109.5; IRC R109.3 INSPECTION ACCESS: PROPERTY LOCKED; INTERIOR NOT ACCESSIBLE. CALL FOR INSPECTION ON DAY WHEN INTERIOR IS ACCESSIBLE.
Occupancy Inspection - Codes Residential Temporary C of O 8/1/2014 at 12:00 AM 08/01/2014
Misc
Partial Correction
08/01/2014
OK FOR TEMPORARY USE & OCCUPANCY AT UNITS A & B
Misc
Corrective Action Required
08/01/2014
EXTERIOR/LOT SUBJECT TO APPROVAL WHEN COMPLETED. NOTE CODE MINIMUM OF 6" CLEARANCE FROM FINISH GRADE TO SIDING OR OTHER WALL FINISH.
Misc
Resolved
08/01/2014
LOOSE/SOFT ELECT RECEPTS. EXAMPLE: GARAGE NE, BREAKFAST AREA, SE BR
Misc
Resolved
08/01/2014
CALL TO ATTENTION OF FIREPLACE INSTALLERS THAT MANUFACTURER'S TAG ATTACHED TO GAS CONNECTORS STATES MINIMUM BEND RADIUS AND THAT WE INTEND FOR IT TO BE FOLLOWED.
Misc
Corrective Action Required
08/01/2014
CRAWL SPACES: 1) POST BASE PLATES NOT SECURED TO FOOTINGS 2) TEMPORARY LIGHT DROP CORD AND LIGHT LEFT IN PLACE AND BURNING. 3) SOME SHIMS NOT CENTERED AT WF BEAM BEARING 4) ONE OR MORE GROUNDING ELECTRODE TERMINATIONS NOT TIGHT 5) INFORMATION REQUIRED ON UNUSED VERTICAL PVC PLUMBING STUBS. TEMPORARY CAPS? 6) IS CRUSHED ROCK TO FINISH AT ELEVATION OF DRAIN. AS IS, ROCK IS WELL BELOW DRAIN AND CONDENSATE DRAINAGE POOLS IN THE DEPRESSIONS. 7) INVESTIGATION REQUIRED WHY UNDERSIDE OF STRUCTURE AND FLOOR INSULATION IS WET. INSULATION SAGGING OR FALLEN. MILDEW OR MOLD (?) ON SURFACE OF INSULATION AND BOTTOM CHORDS OF I-JOISTS.
Misc
Resolved
08/01/2014
IBC 109.1, 109.5; IRC R109.3 INSPECTION ACCESS: PROPERTY LOCKED; INTERIOR NOT ACCESSIBLE. CALL FOR INSPECTION ON DAY WHEN INTERIOR IS ACCESSIBLE.
Occupancy Inspection - Codes Residential Full C of O 8/15/2014 8/15/2014 at 12:00 AM 08/15/2014
Misc
Resolved
08/15/2014
OK FOR TEMPORARY USE & OCCUPANCY AT UNITS A & B
Misc
Resolved
08/15/2014
EXTERIOR/LOT SUBJECT TO APPROVAL WHEN COMPLETED. NOTE CODE MINIMUM OF 6" CLEARANCE FROM FINISH GRADE TO SIDING OR OTHER WALL FINISH.
Misc
Resolved
08/15/2014
CRAWL SPACES: 1) POST BASE PLATES NOT SECURED TO FOOTINGS 2) TEMPORARY LIGHT DROP CORD AND LIGHT LEFT IN PLACE AND BURNING. 3) SOME SHIMS NOT CENTERED AT WF BEAM BEARING 4) ONE OR MORE GROUNDING ELECTRODE TERMINATIONS NOT TIGHT 5) INFORMATION REQUIRED ON UNUSED VERTICAL PVC PLUMBING STUBS. TEMPORARY CAPS? 6) IS CRUSHED ROCK TO FINISH AT ELEVATION OF DRAIN. AS IS, ROCK IS WELL BELOW DRAIN AND CONDENSATE DRAINAGE POOLS IN THE DEPRESSIONS. 7) INVESTIGATION REQUIRED WHY UNDERSIDE OF STRUCTURE AND FLOOR INSULATION IS WET. INSULATION SAGGING OR FALLEN. MILDEW OR MOLD (?) ON SURFACE OF INSULATION AND BOTTOM CHORDS OF I-JOISTS.
Plot Plan Inspection Passed 10/15/2014 at 12:00 AM 10/15/2014
Documents & Images
Date Uploaded File Type Document Name
11/15/2013 Letter Codes Building Permit
12/04/2013 Letter Inspection Summary
02/10/2014 Letter Inspection Summary
02/10/2014 Letter Inspection Summary
02/11/2014 Letter Inspection Summary
02/12/2014 Letter Inspection Summary
02/27/2014 Letter Inspection Summary
04/29/2014 Letter Inspection Summary
05/09/2014 Letter Inspection Summary
05/15/2014 Letter Inspection Summary
06/27/2014 Letter Inspection Summary
07/15/2014 Letter Inspection Summary
07/16/2014 Letter Inspection Summary
07/16/2014 Letter Inspection Summary
08/01/2014 Letter Inspection Summary
08/01/2014 Letter Codes Temporary Certificate of Occupancy
08/15/2014 Letter Field Certificate of Occupancy
08/20/2014 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home