Summary
PRCOM20251167
Building Permit - Commercial
Temporary Occupancy
CITY OF LEES SUMMIT MISSOURI
NEW MULTI-FAMILY
THE REUNION AT BLACKWELL - BUILDING 27, TYPE C -PLEX PLAN REVIEW COMPLETED UNDER PRCOM20250089
03/31/2025
06/17/2025
Locations
Contacts
Avital Homes, LLC, Address:7500 W 151st Street, #23100, Phone:(816) 914-7128  
RED DOG ELECTRIC SERVICES, Address:PO BOX 1, Phone:(913) 208-4816  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
COLLINS WEBB ARCHITECTURE LLC, Address:307 SW MARKET ST, Unit A, Phone:(816) 249-2270  
Doug Jenson - Avital Homes, Phone:(816) 266-0685  
CITY OF LEES SUMMIT MISSOURI, Address:220 SE GREEN ST  
Reviews
Review Type Outcome Est. Completion Date Completed
Final Development Plan Review Approved 04/14/2025 03/31/2025
Mike Weisenborn
Building Plan Review Approved with Conditions 04/14/2025 03/31/2025
Mike Weisenborn
Miscellaneous Correction
Resolved
06/17/2025

Foundation and underlsab plumbing only released at this time. Substantial completion on the santiary and water before private connections can be made. Full access and live hydrants required prior to release of vertical construction.
Licensed Contractors Approved 04/14/2025 03/31/2025
Mike Weisenborn
Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $10,595.00 $10,595.00 Paid 04/03/2025
Water Meter Fee $1,066.76 $1,066.76 Paid 04/03/2025
Sanitary Sewer Development Fee $6,101.00 $6,101.00 Paid 04/03/2025
Valuation Fee for New 3 or 4 Family $4,451.71 $4,451.71 Paid 04/03/2025
Residential Excise Tax Fee $2,480.64 $2,480.64 Paid 04/03/2025
Not Ready Inspection Fee $75.00 $75.00 Paid 03/19/2026
Not Ready Inspection Fee $75.00 $75.00 Paid 03/19/2026
Not Ready Inspection Fee $75.00 $75.00 Paid 03/19/2026
Not Ready Inspection Fee $75.00 $75.00 Paid 03/19/2026
Not Ready Inspection Fee $75.00 $75.00 Paid 03/19/2026
Not Ready Inspection Fee $75.00 $75.00 Paid 03/19/2026
Not Ready Inspection Fee $75.00 $75.00 Paid 03/19/2026
Not Ready Inspection Fee $75.00 $75.00 Paid 03/24/2026
Temporary Occupancy Fee $50.00 $50.00 Paid 03/27/2026
Outstanding Fees Amount Paid Owing Date Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid


$75.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Pending
Erosion Control Inspection Pending
Misc
Corrective Action Required
11/10/2025
No further inspections until erosion control in compliance -clean storm drain top and inlet -clean curb and street -repair downed silt fence
Occupancy Inspection - Engineering Pending
Misc
Informational
03/24/2026
3-24-26 Dustin A, Dev has no outstanding items
Occupancy Inspection - Codes Commercial Pending
Misc
Corrective Action Required
03/30/2026
Erosion control to remain in compliance until sod is in place. All units -sod -splash blocks and sump pump discharge -maintain siding from grade, to be 2” from concrete 6” from dirt
Footing Inspection - Commercial Partial 6/10/2025 6/10/2025 06/10/2025
Misc
Informational
06/10/2025
Footing okay
Footing Inspection - Commercial Partial 6/16/2025 6/16/2025 06/16/2025
Misc
Informational
06/10/2025
-Footing okay -stem wall okay
Erosion Control Inspection Failed 7/1/2025 7/1/2025 07/01/2025
Misc
Corrective Action Required
07/01/2025
No further inspections until erosion control in compliance -clean storm drain top and inlet -clean curb and street -repair downed silt fence
Underslab Plumbing Inspection - Commercial Failed 7/1/2025 7/1/2025 07/01/2025
Misc
Corrective Action Required
07/01/2025
Inspection denied pump water out for inspection Address erosion control issues before calling for reinspection
Underslab Plumbing Inspection - Commercial Not Ready 7/2/2025 7/2/2025 07/02/2025
Misc
Corrective Action Required
07/01/2025
Not ready for inspection Uncover Uncover all covered pipe for inspection Address erosion control issues before calling for reinspection
Underslab Plumbing Inspection - Commercial Passed 7/3/2025 7/3/2025 07/03/2025
Misc
Resolved
07/03/2025
Not ready for inspection Uncover Uncover all covered pipe for inspection Address erosion control issues before calling for reinspection
Footing Inspection - Commercial Passed 7/9/2025 7/9/2025 07/09/2025
Misc
Informational
06/16/2025
-Footing okay -stem wall okay -think red slab areas okay
Sewer Service Inspection Passed 7/22/2025 7/22/2025 07/22/2025
Misc
Informational
07/22/2025
07/22/25, Jamie S, Sewer Service has fall, correct bedding, and is connected to tracer wire.
All Rough Inspection - Commercial Partial 8/11/2025 8/11/2025 08/11/2025
Misc
Informational
08/11/2025
Exterior nail pattern inspection only
Water Service Inspection Passed 08/25/2025
Misc
Informational
08/25/2025
8-20-25 Dustin A, Water service is in and pit is installed to city specs
All Rough Inspection - Commercial Not Ready 10/2/2025 10/2/2025 10/02/2025
Misc
Informational
08/11/2025
Exterior nail pattern inspection only
Misc
Corrective Action Required
10/02/2025
No truss package on site
Electrical Service Inspection Failed 10/8/2025 10/8/2025 10/08/2025
Misc
Corrective Action Required
10/08/2025
Grounding not completed.
All Rough Inspection - Commercial Failed 10/8/2025 10/8/2025 10/08/2025
Misc
Informational
10/02/2025
Exterior nail pattern inspection only
Misc
Corrective Action Required
10/02/2025
-No truss plans approved by the city. -Approved city stamped truss plans required and on site for inspection.
All Rough Inspection - Commercial Failed 10/28/2025 10/28/2025 10/28/2025
Misc
Resolved
10/28/2025
Exterior nail pattern inspection only
Misc
Resolved
10/28/2025
-No truss plans approved by the city. -Approved city stamped truss plans required and on site for inspection.
Misc
Corrective Action Required
10/28/2025
Not a complete inspection, 631 walked through fully only Throughout -missing truss bracing on multiple trusses throughout Only -trusses not fastened together to plans throughout -protect all NM within 6’ of attic accesses -all pfh walls missing king studs -gypsum board at separation walls must be able to extend to exterior sheathing 631 -strap top plate where lapped less than 24” front bedroom 629 627 625
All Rough Inspection - Commercial Failed 10/31/2025 10/31/2025 10/31/2025
Misc
Corrective Action Required
10/28/2025
Not a complete inspection, 631 walked through fully only Truss plans in disarray, organize plans for inspection Throughout -missing truss bracing on multiple trusses throughout -trusses not fastened together to plans throughout -protect all NM within 6’ of attic accesses -all pfh walls missing king studs -gypsum board at separation walls must be able to extend to exterior sheathing -fireblock horizontal max 10’ in separation walls -center separation wall seal at wall space to ceiling space -headers do not match plans -complete framing of separation wall all in attic space 631 -strap top plate where lapped less than 24” front bedroom 629 -front bedroom wall missing stud 627 625
All Rough Inspection - Commercial Failed 11/10/2025 11/10/2025 11/10/2025
Misc
Corrective Action Required
10/31/2025
Inspection denied, erosion control not in compliance Not a complete inspection, 631 walked through fully only Truss plans in disarray, organize plans for inspection Throughout -missing truss bracing on multiple trusses throughout -trusses not fastened together to plans throughout -protect all NM within 6’ of attic accesses -all pfh walls missing king studs -gypsum board at separation walls must be able to extend to exterior sheathing -fireblock horizontal max 10’ in separation walls -center separation wall seal at wall space to ceiling space -headers do not match plans -complete framing of separation wall all in attic space 631 -strap top plate where lapped less than 24” front bedroom 629 -front bedroom wall missing stud 627 625
Erosion Control Inspection Failed 11/10/2025 11/10/2025 11/10/2025
Misc
Corrective Action Required
07/01/2025
No further inspections until erosion control in compliance -clean storm drain top and inlet -clean curb and street -repair downed silt fence
All Rough Inspection - Commercial Failed 11/12/2025 11/12/2025 11/12/2025
Misc
Corrective Action Required
11/10/2025
Inspection denied, erosion control not in compliance Not a complete inspection, 631 walked through fully only Truss plans in disarray, organize plans for inspection Throughout -missing truss bracing on multiple trusses throughout -trusses not fastened together to plans throughout -protect all NM within 6’ of attic accesses -all pfh walls missing king studs -gypsum board at separation walls must be able to extend to exterior sheathing -fireblock horizontal max 10’ in separation walls -center separation wall seal at wall space to ceiling space -headers do not match plans -complete framing of separation wall all in attic space 631 -strap top plate where lapped less than 24” front bedroom 629 -front bedroom wall missing stud 627 625
All Rough Inspection - Commercial Failed 11/12/2025 11/12/2025 11/12/2025
Misc
Corrective Action Required
11/12/2025
Throughout -fireblock horizontal max 10’ in separation walls 631 -strap top plate where lapped less than 24” garage entry 629 627 -orient bath fan to no close off vent piping -complete dryer vent 625 -address broken truss above foyer -strap double top plate at rear bedroom -missing truss screw
Underslab Electrical Inspection - Commercial Passed 11/12/2025 11/12/2025 11/12/2025
All Rough Inspection - Commercial Not Ready 11/13/2025 11/13/2025 11/13/2025
Misc
Corrective Action Required
11/12/2025
Throughout -fireblock horizontal max 10’ in separation walls -fire blocking ever 10’ in separation walls will need as such to completely seal floor to ceiling 631 629 627 625 -address broken truss above foyer
Electrical Service Inspection Not Ready 11/13/2025 11/13/2025 11/13/2025
Misc
Corrective Action Required
10/08/2025
Grounding not complete Ground service to plans
All Rough Inspection - Commercial Not Ready 11/17/2025 11/17/2025 11/17/2025
Misc
Corrective Action Required
11/13/2025
Throughout -fire blocking ever 10’ in separation walls will need as such to completely seal floor to ceiling 631 629 627 625 -address broken truss above foyer
All Rough Inspection - Commercial Passed 11/19/2025 11/19/2025 11/19/2025
Misc
Resolved
11/19/2025
Throughout -fire blocking ever 10’ in separation walls will need as such to completely seal floor to ceiling 631 629 627 625 -address broken truss above foyer
Driveway Inspection Failed 11/24/2025 11/24/2025 11/24/2025
Misc
Corrective Action Required
11/24/2025
11-24-25 Dustin A, Dw has standing water and has not been compacted.
Rated Assembly Inspection Partial 12/5/2025 12/5/2025 12/05/2025
Misc
Informational
12/05/2025
1st layer sheet rock- okay
Driveway Inspection Failed 12/8/2025 12/8/2025 12/08/2025
Misc
Corrective Action Required
11/24/2025
11-24-25 Dustin A, Dw has standing water and has not been compacted. 12-8-25 Dustin A, Dw still has standing water in it.
Driveway Inspection Partial 12/8/2025 12/8/2025 12/08/2025
Misc
Corrective Action Required
12/08/2025
11-24-25 Dustin A, Dw has standing water and has not been compacted. 12-8-25 Dustin A, Dw still has standing water in it. 12-8-25 Dustin A, Dw called in again. Still had water 625 but 627 was good so they can pour that side .
Electrical Service Inspection Failed 12/10/2025 12/10/2025 12/10/2025
Misc
Corrective Action Required
11/13/2025
-Open equipment for inspection -clarify grounding on plans
Rated Assembly Inspection Partial 12/11/2025 12/11/2025 12/11/2025
Misc
Informational
12/05/2025
1st layer sheet rock- okay 2nd layer sheet rock screw pattern in attic space only- okay
Driveway Inspection Partial 12/10/2025 12/10/2025 12/12/2025
Misc
Corrective Action Required
12/08/2025
11-24-25 Dustin A, Dw has standing water and has not been compacted. 12-8-25 Dustin A, Dw still has standing water in it. 12-8-25 Dustin A, Dw called in again. Still had water 625 but 627 was good so they can pour that side . 12-10-25 Dustin A, Water is removed approved to pour
Electrical Service Inspection Failed 12/15/2025 12/15/2025 12/15/2025
Misc
Resolved
12/15/2025
-Open equipment -clarify grounding on plans
Misc
Corrective Action Required
12/15/2025
-no more than one conductor per lug in panel -copper main bonding jumper shall be minimum #4
Electrical Service Inspection Passed 12/18/2025 12/18/2025 12/18/2025
Misc
Resolved
12/18/2025
-no more than one conductor per lug in panel -copper main bonding jumper shall be minimum #4
Rated Assembly Inspection Failed 12/18/2025 12/18/2025 12/18/2025
Misc
Informational
12/11/2025
1st layer sheet rock- okay 2nd layer sheet rock screw pattern in attic space only- okay
Misc
Corrective Action Required
12/18/2025
Seal top of wall throughout 631 -gaps around truss into wall back bedroom 629/627 -gaps around truss into wall back room 627/625 -seal around feeder cable
Rated Assembly Inspection Not Ready 12/19/2025 12/19/2025 12/19/2025
Misc
Informational
12/18/2025
1st layer sheet rock- okay 2nd layer sheet rock screw pattern in attic space only- okay
Misc
Corrective Action Required
12/18/2025
Seal top of wall throughout 631 -gaps around truss into wall back bedroom 629/627 -gaps around truss into wall back room 627/625 -seal around feeder cable
Rated Assembly Inspection Not Ready 12/23/2025 12/23/2025 12/23/2025
Misc
Informational
12/19/2025
1st layer sheet rock- okay 2nd layer sheet rock screw pattern in attic space only- okay
Misc
Corrective Action Required
12/19/2025
Seal top of wall throughout 631 -gaps around truss into wall back bedroom 629/627 -gaps around truss into wall back room 627/625 -seal around feeder cable
Rated Assembly Inspection Failed 12/29/2025 12/29/2025 12/29/2025
Misc
Informational
12/23/2025
1st layer sheet rock- okay 2nd layer sheet rock screw pattern in attic space only- okay
Misc
Corrective Action Required
12/23/2025
Seal top of wall throughout 629/631 Rear of wall 629 not sealed roof line 627/625 -rear of separation wall not sealed at roof line
Rated Assembly Inspection Partial 12/30/2025 12/30/2025 12/30/2025
Misc
Informational
12/29/2025
1st layer sheet rock- okay 2nd layer sheet rock attic space only- okay
Misc
Resolved
12/30/2025
Rated Assembly Inspection Partial 1/8/2026 1/8/2026 01/08/2026
Misc
Resolved
01/08/2026
1st layer sheet rock- okay 2nd layer sheet rock attic space only- okay 2nd layer sheet rock
Rated Assembly Inspection Passed 03/20/2026
Occupancy Inspection - Codes Commercial Failed 3/20/2026 3/20/2026 03/20/2026
Misc
Corrective Action Required
03/20/2026
Erosion control to remain in compliance until sod is in place. No further inspections until erosion control is In compliance. All units -address pending driveway inspection -sod -splash blocks and sump pump discharge -maintain siding from grade, to be 2” from concrete 6” from dirt 625 -all outlets in laundry to be gfci protected -missing attic access cover 627 -missing attic access cover -garage door to be self closing and latching 629 -wiring at rear outlet incorrect -completer under sink areas for ada for inspection -provide attic access cover 631 -all outlets in laundry to be gfci protected -provide attic access
Driveway Inspection Passed 03/20/2026
Misc
Corrective Action Required
12/12/2025
11-24-25 Dustin A, Dw has standing water and has not been compacted. 12-8-25 Dustin A, Dw still has standing water in it. 12-8-25 Dustin A, Dw called in again. Still had water 625 but 627 was good so they can pour that side . 12-10-25 Dustin A, Water is removed approved to pour 3-20-26 Dustin A, dw has been poured to city specs
Occupancy Inspection - Engineering Temporary C of O 3/20/2026 3/20/2026 03/20/2026
Occupancy Inspection - Engineering Temporary C of O 3/24/2026 3/24/2026 03/24/2026
Misc
Informational
03/24/2026
3-24-26 Dustin A, Dev has no outstanding items
Occupancy Inspection - Codes Commercial Not Ready 3/24/2026 3/24/2026 03/24/2026
Misc
Corrective Action Required
03/20/2026
Pay all fees Inspection denied Erosion control not in compliance repair downed silt fence Erosion control to remain in compliance until sod is in place. No further inspections until erosion control is In compliance. All units -address pending driveway inspection -sod -splash blocks and sump pump discharge -maintain siding from grade, to be 2” from concrete 6” from dirt 625 -all outlets in laundry to be gfci protected -missing attic access cover 627 -missing attic access cover -garage door to be self closing and latching 629 -wiring at rear outlet incorrect -completer under sink areas for ada for inspection -provide attic access cover 631 -all outlets in laundry to be gfci protected -provide attic access
Occupancy Inspection - Codes Commercial Ready for Temp CO 3/25/2026 3/25/2026 03/25/2026
Misc
Corrective Action Required
03/24/2026
Erosion control to remain in compliance until sod is in place. All units -sod -splash blocks and sump pump discharge -maintain siding from grade, to be 2” from concrete 6” from dirt
Occupancy Inspection - Codes Commercial Not Ready 3/30/2026 3/30/2026 03/30/2026
Misc
Corrective Action Required
03/25/2026
Erosion control to remain in compliance until sod is in place. All units -sod -splash blocks and sump pump discharge -maintain siding from grade, to be 2” from concrete 6” from dirt
Documents & Images
Date Uploaded File Type Document Name
04/03/2025 Receipt Receipt for transaction:2025-002032
04/03/2025 Letter DS Building Permit
03/31/2025 Approved Plans Approved plans V1
06/16/2025 Letter INSPECTION SUMMARY
06/16/2025 Letter INSPECTION SUMMARY
06/17/2025 Letter DS Building Permit
07/01/2025 Letter INSPECTION SUMMARY
07/01/2025 Letter INSPECTION SUMMARY
07/02/2025 Letter INSPECTION SUMMARY
07/09/2025 Letter INSPECTION SUMMARY
07/09/2025 Letter INSPECTION SUMMARY
03/31/2025 Approved Plans Approved plans V1
03/06/2025 Approved Plans Approved plans V2
07/22/2025 Letter INSPECTION SUMMARY
08/11/2025 Letter INSPECTION SUMMARY
08/25/2025 Letter INSPECTION SUMMARY
10/02/2025 Letter INSPECTION SUMMARY
10/08/2025 Letter INSPECTION SUMMARY
10/08/2025 Letter INSPECTION SUMMARY
10/17/2025 Approved Plans Approved Bldg C Trusses
10/17/2025 Approved Plans Building C truss Seals All C buildngs_STAND REVIEWED
10/28/2025 Letter INSPECTION SUMMARY
10/31/2025 Letter INSPECTION SUMMARY
11/05/2025 Approved Plans Approved G111
11/10/2025 Letter INSPECTION SUMMARY
11/10/2025 Letter INSPECTION SUMMARY
11/12/2025 Approved Plans Approved Truss repair
11/12/2025 Letter INSPECTION SUMMARY
11/12/2025 Letter INSPECTION SUMMARY
11/12/2025 Letter INSPECTION SUMMARY
11/13/2025 Letter INSPECTION SUMMARY
11/13/2025 Letter INSPECTION SUMMARY
11/17/2025 Letter INSPECTION SUMMARY
11/17/2025 Approved Plans Truss repair doc
11/19/2025 Letter INSPECTION SUMMARY
11/24/2025 Letter INSPECTION SUMMARY
12/05/2025 Letter INSPECTION SUMMARY
12/08/2025 Approved Plans Approved E200 revision
12/08/2025 Letter INSPECTION SUMMARY
12/08/2025 Letter INSPECTION SUMMARY
12/08/2025 Letter INSPECTION SUMMARY
12/10/2025 Letter INSPECTION SUMMARY
12/10/2025 Letter INSPECTION SUMMARY
12/11/2025 Letter INSPECTION SUMMARY
12/12/2025 Letter INSPECTION SUMMARY
12/15/2025 Letter INSPECTION SUMMARY
12/18/2025 Letter INSPECTION SUMMARY
12/18/2025 Letter INSPECTION SUMMARY
12/19/2025 Letter INSPECTION SUMMARY
12/23/2025 Letter INSPECTION SUMMARY
12/29/2025 Letter INSPECTION SUMMARY
12/30/2025 Letter INSPECTION SUMMARY
01/08/2026 Letter INSPECTION SUMMARY
02/09/2026 Approved Plans REUNION GRADING PLA
03/19/2026 Receipt Receipt for transaction:2026-001659
03/20/2026 Letter INSPECTION SUMMARY
03/20/2026 Letter INSPECTION SUMMARY
03/20/2026 Letter INSPECTION SUMMARY
03/20/2026 Letter INSPECTION SUMMARY
03/24/2026 Letter INSPECTION SUMMARY
03/24/2026 Letter INSPECTION SUMMARY
03/24/2026 Receipt Receipt for transaction:2026-001774
03/25/2026 Letter INSPECTION SUMMARY
03/27/2026 Certificate/License Codes Temporary Certificate of Occupancy
03/27/2026 Receipt Receipt for transaction:2026-001859
03/30/2026 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home