Summary
PRCOM20232357
Building Permit - Commercial
Certificate of Occupancy
NLV TOWNHOMES LLC
NEW MULTI-FAMILY
VILLAGE AT NEW LONGVIEW TOWNHOMES PHASE 1 - BUILDING 3-- 5 UNIT TOWNHOMES
05/24/2023
07/27/2023
07/17/2023
11/18/2024
Locations
Contacts
NLV TOWNHOMES LLC, Address:3152 SW GRANDSTAND CIR  
O'REILLY BUILD LLC, Address:5051 S NATIONAL AVE STE 4-110, Phone:(417) 862-9500  
Jacob Johnson - O'Reilly Build, Phone:(318) 413-2151  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
CLAYCO ELECTRIC COMPANY, Address:319 E 11TH AVE, Phone:(816) 221-0593  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
CLOCKWORK, Address:423 DELAWARE STREET #102, Phone:(816) 807-3787  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 01/20/2023 05/08/2023
Joe Frogge
LC - General Contractor
Resolved
05/08/2023

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Provide an email address & phone number for the on-site contact which is where inspection reports will be sent.
LC - MEP Subs
Resolved
05/08/2023

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Fees
Paid Fees Amount Paid Owing Date Paid
7232302-Residential Excise Tax Fee $2,121.60 $2,121.60 Paid 07/18/2023
9110078-Valuation Fee for New Multi-Family $8,919.79 $8,919.79 Paid 07/18/2023
8331401-Water Tap Fee $18,800.00 $18,800.00 Paid 07/18/2023
8350015-Water Meter Fee $3,402.30 $3,402.30 Paid 07/18/2023
8331507-Sanitary Sewer Development Fee $10,795.00 $10,795.00 Paid 07/18/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 10/31/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 10/31/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Commercial Partial 9/18/2023 (8:00) 9/18/2023 09/18/2023
Misc
Corrective Action Required
09/18/2023
Building 3 East and North side ok South side from 20-13 ok
Footing Inspection - Commercial Passed 9/19/2023 09/19/2023
Misc
Informational
09/19/2023
Building 3 OK
Foundation Inspection - Commercial Passed 10/4/2023 (8:00) 10/4/2023 10/04/2023
Misc
Informational
10/04/2023
Building 3
Underslab Electrical Inspection - Commercial Passed 10/17/2023 10/17/2023
Underslab Plumbing Inspection - Commercial Passed 10/17/2023 10/17/2023
Erosion Control Inspection Residential Partial 10/17/2023 10/17/2023
Misc
Corrective Action Required
10/17/2023
- Ok at time of inspection.
Foundation Inspection - Commercial Passed 11/7/2023 11/07/2023
Misc
Informational
11/07/2023
- inspected basement floor at building 3.
Footing Inspection - Commercial Partial 2/23/2024 (11:30) 2/23/2024 02/23/2024
Misc
Corrective Action Required
02/23/2024
Building 3 - STEEL FOR FOOTING AT FRONT STOOP APPROVED Building 4 - NOT COMPLETE
Foundation Inspection - Commercial Passed 3/1/2024 03/01/2024
Misc
Informational
03/01/2024
- inspection of steel for front stoops of all Building 3
Footing Inspection - Commercial Passed 3/13/2024 3/13/2024 03/13/2024
Misc
Resolved
03/13/2024
Building 3 - STEEL FOR FOOTING AT FRONT STOOP APPROVED Building 4 - NOT COMPLETE
Footing Inspection - Commercial Passed 3/18/2024 3/18/2024 03/18/2024
Misc
Corrective Action Required
03/18/2024
- inspected rebar for front stairs of building 3
All Rough Inspection - Commercial Failed 3/21/2024 3/21/2024 03/21/2024
Misc
Corrective Action Required
03/21/2024
440 SW Brummel 20232357 Fb = Fire block 440 - provide truss package and layout - Fb sill penetrations 3 rd floor southwest corner near hold down brackets - Provide stud shoe for over bored stud 3 rd floor west bathroom - Fb tub at 3 floor west bathroom - Open 4” y in attic - Fb gaps at top plate edges and 3” DWV at A/C chase third floor ( BOTH) - 4” duct at laundry to be round - Fb chase master shower top plate edges - Check lateral bracing for trusses - Missing window third floor Second floor - Provide missing door - Fb top of A/C chase from vertical to horizontal - Strap over bored top plates Bering wall, strap to extend 6” past damaged area and have no less than 4 nail per side ( boca plates not equal) - Complete hold down bracket near back door Basement - Address 2 x 4 ‘s through four for kitchen railing - Fb vertically every 10’ of demise wall - Provide Egress window - No gas piping installed - provide plans for garage This is a partial list. Inspection ended. Have all MEP’s completed before next inspection 440 is the only unit inspected
All Rough Inspection - Commercial Failed 4/4/2024 4/4/2024 04/04/2024
Misc
Resolved
04/04/2024
Misc
Corrective Action Required
04/04/2024
440 SW Brummel 20232357 Fb = Fire block Fire blocking of chases to be approved materials 2” nominal lumber, 3/4” particle board, 1/2” gypsum, 1/4” cement-based mill board, mineral wool. Etc - ALL complete sprinkler lines throughout - UNIT 440 Second floor - provide truss package and layout - Fb sill penetrations 2nd floor southwest corner near hold down brackets - Provide stud shoe for over bored stud 2 rd floor west bathroom - Fb gaps at top plate edges and 3” DWV at A/C chase 2 nd floor ( BOTH CHASES) - 4” duct at laundry to be round - Fb chase master shower top plate edges - Check lateral bracing for trusses - Missing window third floor Main floor - Provide missing door - Fb top of A/C chase from vertical to horizontal - Joist hanger missing nails near front entry stairs - Strap over bored top plates Bering wall, strap to extend 6” past damaged area and have no less than 4 nail per side ( boca plates not equal) - Complete hold down bracket near back door - Missing nails at joints hangers dining/bathroom Basement - Address 2 x 4 ‘s through four for kitchen railing - Fb vertically every 10’ of demise wall - Provide Egress window UNIT 442 Main floor - Fb gap floor of demise wall near back door toilet - Provide missing windows - Fb top of A/C chase using approved materials Second floor - Fb floor tub plumbing - Fb floor of demise wall West bedroom - Fb floor penetration at hall small closet - Protect wiring within 6’ of attic access - Repair gaps in sheet rock above top plate of demise wall in master bathroom - missing hold downs near front door - Fb floor penetration near front door Basement - stairs stringers need clearance for sheet rock on demise wall UNIT 444 Main floor - nail triple girders together - Fb duct chase at soft with approved materials - Replace broken windows - Provide front door Second Floor - Fb top of ductwork chase ( both of them) with approved material - Fb top of shower chase with approved material - Fb floor penetration at tub plumbing - Provide stud shoe for over bored stud in bathroom back wall - Provide missing window - Dryer vent to be round Basement - provide space for sheet rock at stairs stringers basement - Missing egress window - Fb demise wall every 10’ vertically UNIT 446 Main floor - hold down no complete back toilet room - Fb floor penetration back toilet room - Fb floor penetrations kitchen wall - Provide window and doors - Fb top of ductwork chase with approved materials - Complete sprinkler line and Fb floor penetrations Second floor - Fb top plate back bedroom - Fb floor at tub plumbing - Fb floor at dryer vent box - Dryer vent to be round not distorted - Fb all ductwork chases top and bottom with approved materials Basement - fb demise wall every 10’ vertically - Address overlap zip board under basement stairs UNIT 448 Main floor - Complete fire sprinkler line - Missing hold down South West corner at floor - Provide missing door - Fb top of ductwork chase with approved materials Second floor - Dryer vent to be round not distorted - Fb top of shower chase with approved materials - Fb floor at tub plumbing - Provide Stud shoes on studs back exterior wall bathroom - Fb ductwork chases with approved materials Basement - Missing egress window Need to check 56”x 45” windows with 4” separation, fire rating needed? This in multiple units
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
04/04/2024
Erosion Control Inspection Residential Partial 4/4/2024 04/04/2024
Misc
Corrective Action Required
04/04/2024
- OK at time of inspection
Electrical Service Inspection Passed 4/17/2024 4/17/2024 04/17/2024
Misc
Informational
04/17/2024
-BUILDING 3
All Rough Inspection - Commercial Failed 4/18/2024 4/18/2024 04/18/2024
Misc
Resolved
04/18/2024
Misc
Corrective Action Required
04/18/2024
4/18/24. DO NOT INSULATE 440 SW Brummel 20232357 Fb = Fire block Fire blocking of chases to be approved materials 2” nominal lumber, 3/4” particle board, 1/2” gypsum, 1/4” cement-based mill board, mineral wool. Etc UNIT 440 Second floor - Provide stud shoe for over bored stud 2 rd floor west bathroom - 4” duct at laundry to be round - Fb chase master shower top plate edges - Check lateral bracing for trusses - Missing window third floor Main floor - Provide missing door - Strap over bored top plates Bering wall, living room , strap to extend 6” past damaged area and have no less than 4 nail per side ( boca plates not equal) Basement - Provide Egress window - cap off the 2 DWV’s in floor of demise wall UNIT 442 Main floor - Fb gap floor of demise wall near back door toilet - Provide missing windows - Fb top of A/C chase ( seal gaps) Second floor - Fb floor of demise wall West bedroom - Protect wiring within 6’ of attic access - Repair gaps in sheet rock above top plate of demise wall in master bathroom Basement UNIT 444 Main floor - Replace broken windows - Provide front door Second Floor - Provide stud shoe for over bored stud in bathroom back wall - Provide missing window - Dryer vent to be round Basement - Missing egress window - Fb demise wall every 10’ vertically UNIT 446 Main floor - Provide window and doors - Fb top of ductwork chase with approved materials ( Seal gaps) Second floor - Fb top plate penetration back bedroom - Dryer vent to be round not distorted - Fb ductwork chase near stairs ( seal gaps) Basement Provide Egress window UNIT 448 Main floor - Provide missing door Second floor - Dryer vent to be round not distorted - Provide Stud shoes on studs back exterior wall bathroom Basement - Missing egress window DO NOT INSULATE
All Rough Inspection - Commercial Failed 4/19/2024 4/19/2024 04/19/2024
Misc
Corrective Action Required
04/18/2024
440 SW Brummel 20232357 UNIT 440 Second floor - Provide stud shoe for over bored stud 2 rd floor west bathroom - 4” duct at laundry to be round - Fb chase master shower top plate edges - Missing window third floor Main floor - Provide missing door - Strap over bored top plates Bering wall, living room , strap to extend 6” past damaged area and have no less than 4 nail per side ( boca plates not equal) Basement - Provide Egress window - cap off the 2 DWV’s in floor of demise wall UNIT 442 Main floor - Provide missing windows UNIT 444 Main floor - Replace broken windows - Provide front door Second Floor - Provide stud shoe for over bored stud in bathroom back wall - Provide missing window - Dryer vent to be round Basement - Missing egress window UNIT 446 Main floor - Provide window and doors Second floor - Fb top plate penetration back bedroom - Dryer vent to be round not distorted Basement Provide Egress window UNIT 448 Main floor - Provide missing door Second floor - Dryer vent to be round not distorted - Provide Stud shoes on studs back exterior wall bathroom Basement - Missing egress window
All Rough Inspection - Commercial Failed 4/23/2024 4/23/2024 04/23/2024
Misc
Corrective Action Required
04/19/2024
440 SW Brummel 20232357 UNIT 440 Second floor - 4” duct at laundry to be round - Missing window third floor Main floor - Provide missing door Basement - Provide Egress window UNIT 442 Main floor - Provide missing windows UNIT 444 Main floor - Replace broken windows - Provide front door Second Floor - Provide missing window - Dryer vent to be round Basement - Missing egress window UNIT 446 Main floor - Provide window and doors Second floor - Dryer vent to be round not distorted Basement Provide Egress window UNIT 448 Main floor - Provide missing door Second floor - Dryer vent to be round not distorted Basement - Missing egress window OK TO INSULATE
Rated Assembly Inspection Not Ready 5/6/2024 5/6/2024 05/06/2024
ELEVATOR 1
Corrective Action Required
04/04/2024
- 440 Basement not complete 442 - not ready 444 - did not inspect
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
04/04/2024
Corrective Action Required
04/04/2024
Corrective Action Required
04/04/2024
Rated Assembly Inspection Partial 5/9/2024 5/9/2024 05/09/2024
ELEVATOR 1
Corrective Action Required
05/06/2024
- 440 Screws Ok 442 Screws Ok -444 - Screws Ok 446 - not ready 448 - not ready
Rated Assembly Inspection Passed 5/16/2024 5/16/2024 05/16/2024
ELEVATOR 1
Resolved
05/16/2024
- 440 Screws Ok 442 Screws Ok -444 - Screws Ok 446 - not ready 448 - not ready
Footing Inspection - Commercial Passed 6/27/2024 06/27/2024
Misc
Informational
06/27/2024
INSPECTION OF FOOTING STEEL FOR GARAGE.
Erosion Control Inspection Residential Failed 6/27/2024 06/27/2024
Misc
Corrective Action Required
06/27/2024
- CLEAN STREETS ON LOT
Foundation Inspection - Commercial Passed 7/9/2024 7/9/2024 07/09/2024
Misc
Informational
07/09/2024
Garage foundation Building 3
All Rough Inspection - Commercial Partial 8/19/2024 08/19/2024
Misc
Informational
08/19/2024
- Shear wall and nail patern on garages for building 4 Approved
Underground Electrical Inspection - Commercial Partial 8/26/2024 08/26/2024
THE FOLLOWING AREAS ARE APPROVED
Informational
08/26/2024
5 Helical light poles bases and conduit open trench for Building 1 North side Building 3 North side Bewteen Building 1-2 Bewteen Building 3-4
All Rough Inspection - Commercial Failed 8/26/2024 08/26/2024
Misc
Informational
08/21/2024
- Shear wall and nail patern on garages for building 4 Approved
Misc
Corrective Action Required
08/26/2024
- Tighten anchor bolts 446 - Provide attic access
Underground Electrical Inspection - Commercial Partial 8/28/2024 8/28/2024 08/28/2024
THE FOLLOWING AREAS ARE APPROVED
Informational
08/26/2024
5 Helical light poles bases and conduit open trench for -Building 1 North side -Building 3 North side =Bewteen Building 1-2 -Bewteen Building 3-4 -ACROSS FRON OF BUILDING 3 -20 IRRIGATION CONTROL FROM NORTH EAST CORNER OF BUILDING 3 TO QUASI BOX
Miscellaneous Inspection Partial 8/29/2024 8/29/2024 08/29/2024
Misc
Corrective Action Required
08/29/2024
440 - Uncover all smoke detectors - Top step at second floor exceeds the 3/8” variance allowed - Basement stairs top step over 7 3/4” and exceeds 3/8” variance - No back flow preventer at water main spigot - Electrical panel not labeled - GFCI s will be tested on next visit
THE FOLLOWING AREAS ARE APPROVED
Informational
08/29/2024
All deck framing for Building 3 440 SW Brummel
Miscellaneous Inspection Partial 9/4/2024 09/04/2024
Misc
Corrective Action Required
08/29/2024
440 - support expansion tank at water heater Ok for staging
THE FOLLOWING AREAS ARE APPROVED
Informational
08/29/2024
All deck framing for Building 3 440 SW Brummel - Building 3 garages all rough approved
Misc
Corrective Action Required
09/04/2024
442 Brummel - provide security screws at exterior doors hinges and strike plates (2) per hinge 3” - support expansion tank at water heater - handrail at bottom of second floor stairs below 34” Ok for staging
Underground Electrical Inspection - Commercial Partial 9/6/2024 09/06/2024
THE FOLLOWING AREAS ARE APPROVED
Informational
08/28/2024
5 Helical light poles bases and conduit open trench for -Building 1 North side -Building 3 North side =Bewteen Building 1-2 -Bewteen Building 3-4 =From building 4 under dive to transformer -ACROSS FRON OF BUILDING 3 -20 IRRIGATION CONTROL FROM NORTH EAST CORNER OF BUILDING 3 TO QUASI BOX
Electrical Service Inspection Passed 9/20/2024 9/20/2024 09/20/2024
Misc
Informational
09/20/2024
service for lighting
All Rough Inspection - Commercial Passed 10/9/2024 10/09/2024
Misc
Resolved
10/09/2024
440 SW Brummel 20232357 UNIT 440 Second floor - 4” duct at laundry to be round - Missing window third floor Main floor - Provide missing door Basement - Provide Egress window UNIT 442 Main floor - Provide missing windows UNIT 444 Main floor - Replace broken windows - Provide front door Second Floor - Provide missing window - Dryer vent to be round Basement - Missing egress window UNIT 446 Main floor - Provide window and doors Second floor - Dryer vent to be round not distorted Basement Provide Egress window UNIT 448 Main floor - Provide missing door Second floor - Dryer vent to be round not distorted Basement - Missing egress window OK TO INSULATE
Underground Electrical Inspection - Commercial Passed 10/9/2024 10/09/2024
THE FOLLOWING AREAS ARE APPROVED
Informational
09/06/2024
5 Helical light poles bases and conduit open trench for -Building 1 North side -Building 3 North side =Bewteen Building 1-2 -Bewteen Building 3-4 =From building 4 under dive to transformer -ACROSS FRON OF BUILDING 3 -20 IRRIGATION CONTROL FROM NORTH EAST CORNER OF BUILDING 3 TO QUASI BOX
Gas Piping Inspection - Commercial Passed 10/9/2024 10/09/2024
Gas Service Inspection - Commercial Passed 10/9/2024 10/09/2024
Erosion Control Inspection Residential Partial 10/9/2024 10/09/2024
Misc
Corrective Action Required
10/09/2024
- IN PLACE AT TIME OF INSPECTION
Miscellaneous Inspection Failed 10/9/2024 10/9/2024 10/09/2024
Misc
Resolved
10/09/2024
440 - support expansion tank at water heater Ok for staging
THE FOLLOWING AREAS ARE APPROVED
Resolved
10/09/2024
All deck framing for Building 3 440 SW Brummel - Building 3 garages all rough approved
Misc
Resolved
10/09/2024
442 Brummel - provide security screws at exterior doors hinges and strike plates (2) per hinge 3” - support expansion tank at water heater - handrail at bottom of second floor stairs below 34” Ok for staging
Misc
Corrective Action Required
10/09/2024
All units - Provide gutters and downspouts - Splash pads - Final grading and sod - Irrigation permit - Water meter at grade with meter 14-18” from lid and gravel in bottom - provide 1 outlet per car bay in garage - Complete back courtyards - provide guard at front porch, over 30” to grade - Complete lighting on front porches - All water mains to have regulator installed 440 - Seal exterior penetrations - Outlet at AC compressor to be GFCI protected - Label non GFCI outlet at water heater - Handy box outlet at electrical panel to be GFCI protected 442 - Label non GFCI outlet at water heater - Handy box outlet at electrical panel to be GFCI protected 444 - Second floor sprinkler head obstructed by attic access trim - Label non GFCI outlet at water heater - Outlet at electrical panel to be GFCI protected - Outlet at AC compressor not GFII protected 446 - GFCI protection required at outlet at AC compressor - Label non- GFCI outlet at water heater - Outlet at electrical panel to be GFCI protected - Label non GFCI outlet at water heater - Outlet at electrical panel to be GFCI protected - Basement Egress window damaged - Cap future vent in basement 448 - Second Floor sprinkler head obstructed by attic access trim - Top step of rise of basement stairs over 7 3/4” and out of 3/8” valence - Label non GFCI at water heater - Outlet at electrical panel not GFCI protected
Misc
Corrective Action Required
10/09/2024
Underground Electrical Inspection - Commercial Partial 10/15/2024 10/15/2024
Misc
Informational
10/15/2024
ELECTRICAL CONDUIT FOR LGHT POLES: -BRUMMEL TO HAVERFORD -LONGHORN TO KESSLER
Occupancy Inspection - Engineering Failed 10/23/2024 10/23/2024
Miscellaneous Correction
Corrective Action Required
10/23/2024
Building 3 punch list: For TCO- Fix issues with water meters For Final- Fix cracks in curbs and replace curb infront of ADA ramp. Extend blind indicator the width of the curb.
Underground Electrical Inspection - Commercial Passed 10/23/2024 10/23/2024
Misc
Informational
10/15/2024
ELECTRICAL CONDUIT FOR LGHT POLES: -BRUMMEL TO HAVERFORD -LONGHORN TO KESSLER
Miscellaneous Inspection Passed 10/23/2024 10/23/2024
Misc
Corrective Action Required
10/09/2024
All units - Provide gutters and downspouts - Splash pads - Final grading and sod - Irrigation permit - Water meter at grade with meter 14-18” from lid and gravel in bottom - provide 1 outlet per car bay in garage - Complete back courtyards - provide guard at front porch, over 30” to grade - Complete lighting on front porches - All water mains to have regulator installed 440 - Seal exterior penetrations - Outlet at AC compressor to be GFCI protected - Label non GFCI outlet at water heater - Handy box outlet at electrical panel to be GFCI protected 442 - Label non GFCI outlet at water heater - Handy box outlet at electrical panel to be GFCI protected 444 - Second floor sprinkler head obstructed by attic access trim - Label non GFCI outlet at water heater - Outlet at electrical panel to be GFCI protected - Outlet at AC compressor not GFII protected 446 - GFCI protection required at outlet at AC compressor - Label non- GFCI outlet at water heater - Outlet at electrical panel to be GFCI protected - Label non GFCI outlet at water heater - Outlet at electrical panel to be GFCI protected - Basement Egress window damaged - Cap future vent in basement 448 - Second Floor sprinkler head obstructed by attic access trim - Top step of rise of basement stairs over 7 3/4” and out of 3/8” valence - Label non GFCI at water heater - Outlet at electrical panel not GFCI protected
Occupancy Inspection - Codes Commercial Failed 10/23/2024 10/23/2024
Misc
Corrective Action Required
10/23/2024
All units - Provide gutters and downspouts - Splash pads - Irrigation permit - Water meter at grade with meter 14-18” from lid and gravel in bottom - All water mains to have regulator installed 446 - Basement Egress window damaged
Occupancy Inspection - Planning Passed 10/23/2024 10/23/2024 10/24/2024
Erosion Control Inspection Residential Passed 10/29/2024 10/29/2024
Misc
Resolved
10/29/2024
- CLEAN STREETS ON LOT
Occupancy Inspection - Codes Commercial Failed 10/29/2024 10/29/2024 10/29/2024
Misc
Corrective Action Required
10/23/2024
All units - Provide Splash pads - All water mains to have regulator installed after fire sprinkler line
Occupancy Inspection - Codes Commercial Failed 10/30/2024 10/30/2024 10/30/2024
Misc
Corrective Action Required
10/29/2024
All units - Provide Splash pads - All water mains to have regulator installed after fire sprinkler line Shawn Hoffman 10/30/2024 1:37 PM incorrect instalation of regulators
Occupancy Inspection - Engineering Temporary C of O 10/30/2024 10/30/2024 10/30/2024
Miscellaneous Correction
Corrective Action Required
10/23/2024
Building 3 punch list: For TCO- Fix issues with water meters For Final- Fix cracks in curbs and replace curb infront of ADA ramp. Extend blind indicator the width of the curb. 10-30-24 DP. Water meter issues have been fixed. TCO Granted Still need to fix site work before receiving C/O
Sewer Service Inspection Passed 10/31/2024 10/31/2024 10/31/2024
Misc
Informational
10/31/2024
10-31-24 DP. All sewer services have been installed with repairs completed.
Water Service Inspection Passed 10/31/2024 10/31/2024 10/31/2024
Misc
Informational
10/31/2024
10-31-24 DP. All water services have been installed with all repairs completed.
Occupancy Inspection - Engineering Passed 10/31/2024 10/31/2024 10/31/2024
Miscellaneous Correction
Corrective Action Required
10/23/2024
Building 3 punch list: For TCO- Fix issues with water meters For Final- Fix cracks in curbs and replace curb infront of ADA ramp. Extend blind indicator the width of the curb. 10-31-24 DP. All punch list items for building 3 have been completed. The repairs to the curb will be transferred to PRSITE20224130
Occupancy Inspection - Codes Commercial Ready for Temp CO 10/31/2024 10/31/2024
Misc
Corrective Action Required
10/30/2024
All units - Provide Splash pads
Occupancy Inspection - Codes Commercial Full C of O 11/18/2024 11/18/2024 11/18/2024
Misc
Resolved
11/18/2024
All units - Provide Splash pads
Documents & Images
Date Uploaded File Type Document Name
07/18/2023 Receipt Receipt for transaction:2023-005574
07/27/2023 Letter DS Building Permit
09/18/2023 Letter INSPECTION SUMMARY
09/19/2023 Letter INSPECTION SUMMARY
10/04/2023 Letter INSPECTION SUMMARY
10/17/2023 Letter INSPECTION SUMMARY
10/17/2023 Letter INSPECTION SUMMARY
10/17/2023 Letter INSPECTION SUMMARY
11/07/2023 Letter INSPECTION SUMMARY
02/23/2024 Letter INSPECTION SUMMARY
03/01/2024 Letter INSPECTION SUMMARY
03/13/2024 Letter INSPECTION SUMMARY
03/18/2024 Letter INSPECTION SUMMARY
03/21/2024 Letter INSPECTION SUMMARY
04/04/2024 Letter INSPECTION SUMMARY
04/04/2024 Letter INSPECTION SUMMARY
04/17/2024 Letter INSPECTION SUMMARY
04/18/2024 Letter INSPECTION SUMMARY
04/19/2024 Letter INSPECTION SUMMARY
04/23/2024 Letter INSPECTION SUMMARY
05/06/2024 Letter INSPECTION SUMMARY
05/09/2024 Letter INSPECTION SUMMARY
05/16/2024 Letter INSPECTION SUMMARY
06/27/2024 Letter INSPECTION SUMMARY
06/27/2024 Letter INSPECTION SUMMARY
07/09/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/26/2024 Letter INSPECTION SUMMARY
08/26/2024 Letter INSPECTION SUMMARY
08/28/2024 Letter INSPECTION SUMMARY
08/29/2024 Letter INSPECTION SUMMARY
09/04/2024 Letter INSPECTION SUMMARY
09/06/2024 Letter INSPECTION SUMMARY
09/20/2024 Letter INSPECTION SUMMARY
10/09/2024 Letter INSPECTION SUMMARY
10/09/2024 Letter INSPECTION SUMMARY
10/09/2024 Letter INSPECTION SUMMARY
10/09/2024 Letter INSPECTION SUMMARY
10/09/2024 Letter INSPECTION SUMMARY
10/09/2024 Letter INSPECTION SUMMARY
10/15/2024 Letter INSPECTION SUMMARY
10/23/2024 Letter INSPECTION SUMMARY
10/23/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
10/30/2024 Letter INSPECTION SUMMARY
10/31/2024 Letter INSPECTION SUMMARY
10/31/2024 Letter INSPECTION SUMMARY
10/31/2024 Letter INSPECTION SUMMARY
10/31/2024 Certificate/License Codes Temporary Certificate of Occupancy
10/31/2024 Receipt Receipt for transaction:2024-008700
11/18/2024 Letter Field Certificate of Occupancy
11/18/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home