Planning Application Status

PL2025054




 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PL2025054
HCA - Lee's Summit Medical Center - ED Expansion
Commercial Final Development Plan
Commercial Final Development Plan
Approved
03/11/2025
MIDWEST DIVISION LSH LLC
2,900 sf addition to Lee's Summit Medical Center
Locations
Contacts
MIDWEST DIVISION LSH LLC, Address:PO BOX 80610  
Wesley Blissard, Address:1524 Williams Drve, Phone:(615) 785-7836  
Reviews
Review Type Outcome Est. Completion Date Completed
Engineering Review Approved with Conditions 04/18/2025 04/16/2025
Susan Nelson, P.E.
DE C&O #01 Eng Plans – FDP/PDP
Corrective Action Required
04/16/2025

All required engineering plans and studies, including water lines, sanitary sewers, storm drainage, streets and erosion and sediment control shall be submitted along with the final development plan. All public infrastructure must be substantially complete, prior to the issuance of any certificates of occupancy.
DE C&O #03 Eng & Insp Fees
Corrective Action Required
04/16/2025

All Engineering Plan Review and Inspection Fees shall be paid prior to approval of the associated engineering plans and prior to the issuance of any site development permits or the start of construction (excluding land disturbance permit).
DE C&O #11 Pavement Thickness
Corrective Action Required
04/16/2025

Private parking lots shall follow Article 8 of the Unified Development Ordinance for pavement thickness and base requirements.
DE Contact Field Eng. Inspector
Corrective Action Required
04/16/2025

Prior to the commencement of any construction activities, the Contractor shall contact Field Engineering Inspections at (816) 969-1200 to coordinate a preconstruction meeting / conference with the assigned Field Engineering Inspector.
DE Future Repair Work
Corrective Action Required
04/16/2025

Please be aware that any future repair work to public infrastructure (e.g., water main repair, sanitary sewer repair, storm sewer repair, etc.) within public easements will not necessarily include the repair of pavement, curbing, landscaping, or other private improvements which are located within the easement.
DE Engineers Estimate
Corrective Action Required
04/16/2025

The Engineer’s Estimate of Probable Construction Costs has been accepted for this project, and the Engineering Plan Review and Inspection Fee (which is calculated as 3% of the total infrastructure cost plus a water test inspection fee(s)), and the water tap and meter setup fee have been included. These must be paid prior to the issuance of an infrastructure permit and/or the final processing of a building permit. $2022.83
Planning Review No Comments 04/18/2025 04/14/2025
Claire Byers
Engineering Review Corrections 03/26/2025 03/26/2025
Susan Nelson, P.E.
Corrective Action Required
03/26/2025

Submit an Engineer's Estimate of Probable Construction Costs.
Corrective Action Required
03/26/2025

Please add a note stating: "All construction shall follow the City of Lee's Summit Design and Construction Manual as adopted by Ordinance 5813. Where discrepancies exist between these plans and the Design and Construction Manual, the Design and Construction Manual shall prevail."
Corrective Action Required
03/26/2025

Add a note stating: “The contractor shall contact the City’s Development Services Engineering Inspection to schedule a pre-construction meeting with a Field Engineering Inspector prior to any land disturbance work at (816) 969-1200.”
Corrective Action Required
03/26/2025

Add a note regarding protecting the existing water line that runs beneath the pavement where removals are proposed.
Corrective Action Required
03/26/2025

The existing storm sewer lines shown in the plans do not appear to agree with City mapping. The storm sewer line that is indicated for abandonment is not identified on City mapping. There is an existing east-west storm sewer line shown on City mapping that is not shown in these plans but could be shown by expanding the plan view slightly to the south. Please verify existing infrastructure and revise the plans accordingly.
Corrective Action Required
03/26/2025

Add stormwater drainage information to the plans including the drainage map, pipe/inlet calculations, and pipe profiles. Please provide unique identification letter/numbers for each structure. Add site/project specific ADS design information.
Corrective Action Required
03/26/2025

For storm structure G5 (eastmost structure), the crown of the incoming pipe must be at or above the crown of the exiting pipe in a structure with a minimum fall of 0.5 feet at a 90-degree connection. Verify that this structure and all other structures are in accordance with APWA Section 5604.5 - Inverts and Pipes.
Corrective Action Required
03/26/2025

Add all City standard details that pertain to this project including, but not limited to, curb/gutter, concrete pavement jointing, sidewalks/ramps, etc.
Corrective Action Required
03/26/2025

Please provide a graphic and notes showing the aggregate base to be extended a minimum of 12 inches beyond the back of curb. The City standard detail does not show this, so provide either a standalone curb detail or add the curb detail to the typical pavement section.
Corrective Action Required
03/26/2025

Provide a complete plan for the ADA-accessible ramps and sidewalks. Ensure the plans include all site-specific width/length dimensions, elevation callouts, running slope callouts, and cross-slope points for the construction of ADA-accessible ramps and sidewalks. Include all ADA facilities for access to the building.
Fire Review Approved with Conditions 03/26/2025 03/25/2025
Jim Eden
Code Statement
Corrective Action Required
03/26/2025

All issues pertaining to life safety and property protection from the hazards of fire, explosion or dangerous conditions in new and existing buildings, structures and premises, and to the safety to fire fighters and emergency responders during emergency operations, shall be in accordance with the 2018 International Fire Code. Meet egress requirements during construction.
Traffic Review No Comments 03/26/2025 03/24/2025
Erin Ralovo
Planning Review Corrections 03/26/2025 03/18/2025
Claire Byers
Corrective Action Required
03/17/2025

C.25. Oil & Gas Wells. The location of all oil and/or gas wells within the subject property. Per UDO, please add. If none, include statement in notes indicating none and reference source.
Corrective Action Required
03/17/2025

Site plan notes 're-installed site signage', sign permits required if signage will be relocated/added.
Corrective Action Required
03/17/2025

Landscape plan references 6 shrubs req. for 'Open Yard minimum', but only 5 provided in text. 6+ shown on plan so just revise language to match.
Corrective Action Required
03/17/2025

"C.31. Mechanical Screening . Location, size, and type of material to be used in all screening of ground mounted mechanical equipment." Is decontamination tank above ground? If so, provide screening plan.
Corrective Action Required
03/17/2025

D.2. Screening Materials . Location, size and materials to be used in all screening of rooftop mechanical equipment. Confirm if any roof-mounted equipment is proposed.
Corrective Action Required
03/18/2025

11 trees will be removed per conservation plan; only 3 trees proposed per landscape plan. Please add 8 more trees to landscape plan. These can be added anywhere on site, potentially add some to landscape island just south of project scope with two dead trees labeled.
Building Codes Review No Comments 03/26/2025 03/14/2025
Joe Frogge
Fees
Paid Fees Amount Paid Owing Date Paid
9110077-Final Development Plan fee $1,200.00 $1,200.00 Paid 04/16/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Hearings
Title Location Date Time
Documents & Images
Date Uploaded File Type Document Name
03/11/2025 Application Form Application_PL2025054
03/11/2025 Activity Document FDP Submittal Checklist_PL2025054
03/11/2025 Plans Plan Set_Rev0_PL2025054
03/11/2025 Activity Document Site Elec Specs_PL2025054
03/11/2025 Activity Document Site Light Fixture Cutsheets_PL2025054
03/11/2025 Engineer Report/Study Stormwater Memo_PL2025054
03/26/2025 Letter Applicant Letter - FDP_PL2025054
04/10/2025 Engineers Estimate Engineers Cost Estimate_PL2025054
04/10/2025 Plans Plan Set_Rev1_PL2025054
04/10/2025 Plans Original LSMC Plans_PL2025054
04/10/2025 Letter Response Letter_PL2025054
04/16/2025 Activity Document Fee Worksheet_PL2025054
04/16/2025 Letter Applicant Letter - FDP_PL2025054
04/16/2025 Receipt Receipt for transaction:2025-002390
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New license, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home